You are on page 1of 3

AC310 High Power Parallel Solution

1. Appearance

AC310 Appearance

2. Hardware Topology
R1
P1 EL1
P+
L1
+
R2
C1
R
R
S
S
T
T
进线断 C2
R3

M
路器

- R1
P1 EL1
P+
L1
+
R2
C1
R
S
T
C2
R3

-
Hardware Topology

Address: Shen Zhen base:


Block C, WenTao Science and Technology Park, Shiyan, Yingrenshi Community,
Bao an District, Shenzhen City, China.
Suzhou base:
No.1000 Songjia Road, Wuzhong Economic & Technological Development Zone, Suzhou
Website: www.veichi.org Facebook & Twitter & Wechat: VeichiGlobal
Adopt the parallel plan and adopt two AC300-T3-400 machines to form the system. The two machine group cabinets are
equipped with related configurations to form a 800kw single machine. And the input voltage of the two inverters in the front
section and the two machines must share a common bus.
Stand-alone size: (1400x460X545), see the picture below for two stand-alone parallels:

920
300 460

1400

1363

300

920

Inverter Dimension

Address: Shen Zhen base:


Block C, WenTao Science and Technology Park, Shiyan, Yingrenshi Community,
Bao an District, Shenzhen City, China.
Suzhou base:
No.1000 Songjia Road, Wuzhong Economic & Technological Development Zone, Suzhou
Website: www.veichi.org Facebook & Twitter & Wechat: VeichiGlobal
3. Control Part
External Brake Unit

R External External DC Rector


Brake
Resistor Short Note1
Piece
MCCB Contactor Input Rector Output Rector
AC POWER INPUT

(-) (+) (+) PB (+) P1


U
R R U
V M
S S V ~
W
T T W
Shielded cable or armoured cable
VFD
(the end close to VFD grounding)
Note2 +24V E (The grounding resistance
PLC is less than 10 ohms)
Note:Function description in brackets is COM
factory default AC220V MAX Output Of Contact:

Passive contact
TA 3A/240VAC
(Forward) X1 Coil 5A/30VDC

output
TB
(Reverse) X2
Multi function contact input

TC
(FWD JOG) X3
AC0V
(REV JOG) X4
+24V
Open collector(OC)

(Free STOP) X5 Shielded cable


Coil
PUL Y (the end close
state output

to VFD grounding)
COM
COM
A+ Note:
RS485 Differential 120Ω 1.MAX Output of +24V Port:DC24V/100mA
Communication 2.Max Output of Y Port :DC24V/50mA
B-

Shielded cable (the end close to 10

VFD grounding) _
Frequency control input

+10V mA
20
0

Analog Voltage/Current quantity input


Analog monitoring
signal output

AI1 + -
Analog Voltage/Current quantity input Shielded cable (the
AI2 A0
GND end close to VFD
grounding)
GND
Note: 1.MAX Output of +10V port :50mA
Note:When output type of AO port as
2.Inner resistance of AI1/AI2 Port frequency and Voltage,
Maximum Output:2mA
Legend: 1.Symbol represent main circuit terminals;
2.Symbol represent control circuit terminals.

* See AC310 manual for specific parameters.

Address: Shen Zhen base:


Block C, WenTao Science and Technology Park, Shiyan, Yingrenshi Community,
Bao an District, Shenzhen City, China.
Suzhou base:
No.1000 Songjia Road, Wuzhong Economic & Technological Development Zone, Suzhou
Website: www.veichi.org Facebook & Twitter & Wechat: VeichiGlobal

You might also like