RHINO-LARYNGO VIDEOSCOPE

ENF-VT3
4-Angle Observation and Treatment with High-Quality Imaging

1
41834
ENF-VT3

ENF-VT3 Specifications Four-Direction Angulation


Field of view 90°
Optical 0° (forward
Direction of view
system viewing)
Depth of field 2 – 50 mm
Distal end outer diameter 4.8 mm
Distal end enlarged UP 1
1 Objective lens
Insertion RIGHT LEFT
2 Light guide lens
section 3 2
3 Instrument channel outlet DOWN

88382

88383
Insertion tube outer diameter 4.9 mm
Insertion section working length 365 mm
Channel inner diameter 2.0 mm Featuring the same slim outer diameter as the conventional
Minimum visible distance 3.5 mm model*, the ENF-VT3 is the world’s first rhino-laryngo
Instrument
channel Direction from which videoscope to incorporate four-direction angulation capability.
endotherapy accessories enter The addition of 70° right/left angulation to the previously
and exit the endoscopic image
available* 130° up/down has dramatically improved the
Bending Up/Down 130° approach to a lesion. Angulation in four-directions is
Angulation range
section Right/Left 70°
possible using just one hand, allowing the other hand to
Total length 645 mm
simultaneously manipulate a therapeutic accessory.
NBI
observation Available
mode
High- Higher-Quality Imaging
frequency Compatible
treatment The incorporation of a high-
Laser performance CCD further improves
Compatible
treatment image quality and contributes to
Compatible observations and treatments of small
video OTV-S300/S200/S190, CV-190/170
processor
lesions due to its clear field of view.

Rhino-Laryngo Videoscope ENF-VT3 Close Focus Observation

The close-focus capability enables observation from just 2


mm for situations when more precision and finer detail is
required, such as viewing minute variations and lesions in
the mucosa.

Enhanced Visualization

Narrow Band Imaging (NBI) is a patented optical image


88384

technology that enhances the visibility of vessels and other


tissue on the mucosal surface. NBI works by filtering the
Disposable Biopsy Forceps Grasping Forceps
white light into specific light wavelengths, which are
S00131EN · 06/20 · OEKG

absorbed by hemoglobin and penetrate only the surface of


human tissue. This highlights areas of increased vascularity
FB-211D FB-221D FB-231D FB-241D FG-14P-1 FG-20P-1
which are normally difficult to distinguish.