Professional Documents
Culture Documents
Pressure Relief
1 2 3 4 5 Temperature Limits
Ambient
Min. . . . . . . . . . . . . . . . . . . –20_C (–4_F)
1 Special seals Max. . . . . . . . . . . . . . . . . . +70_C (158_F)
See “Hydraulic Fluids” section. Fluid temperature
Petroleum Water-
2 Basic model
oil containing
3 Pressure adjustment range Min. –20_C +10_C
B = 5,2-69 bar (75-1000 psi) (–4_F) (50_F)
C = 35-138 bar (500-2000 psi) Max.* +80_C +54_C
F = 104-210 bar (1500-3000 psi) (+176_F) (129_F)
* To obtain optimum service life from both
4 Design number fluid and hydraulic system 65_C (150_F)
normally is the maximum temperature
Subject to change. except for water-containing fluids.
Basic Characteristics Installation dimensions remain as
Operating pressures . . . Up to 210 bar For synthetic fluids consult manufacturer
shown for designs 10-19 inclusive.
(3000 psi) or Vickers representative where limits
Flow rating . . . . . 12 L/min (3.2 USgpm) are outside those for petroleum use.
Mounting . . . . . . . . . . . . . . . . . . . . . Panel 5 Port tappings
Whatever the actual temperature range,
UB = G (BSPF) pipe threads
ensure that viscosities stay within the
General Description limits specified in the “Hydraulic Fluids”
This single-stage valve is designed for Operating Data section.
applications requiring an adjustable
Maximum Pressure Contamination Control Requirements
pressure relief valve or pressure
According to adjustment range. See Recommendations on contamination
regulating valve of small capacity. It may
“Model Code” above. control methods and the selection of
also be used as a remote control valve
products to control fluid condition are
for pilot operated pressure control Maximum Flow Rate included in Vickers publication 561,
valves (e.g. models ECG-06/10). All models . . . . . . 12 L/min (3.2 USgpm) “Vickers Guide to Systemic
Contamination Control”. The book also
Hydraulic Fluids and Seals
includes information on the Vickers
All valves can be used with antiwear
Functional Symbol hydraulic oils, water-in-oil emulsions and concept of “ProActive Maintenance”.The
following recommendations are based
water glycols.
on ISO cleanliness levels at 2 mm, 5 mm
Add prefix “F3” to model designation and 15 mm. For products in this catalog
when phosphate ester (except the recommended levels are:
alkyl-based) or chlorinated hydrocarbons
Up to 210 bar (3000 psi) . . . . . 19/17/14
are to be used.
3rd angle
Installation Dimensions projection
in mm (inches) 4 holes Ø6,8 (0.27 dia)
countersunk 11,0 (0.43) deep
P.C.D Ø73,2
57,2 (2.25) (2.88 dia)
Handwheel for
pressure adjustment
Locknut
59 (2.32)
1,6 max.
12,7 (0.50) (0.06)
77,8
117,5 (3.06)
Tank return port G1/4 (4.62)
Pipe fitting must not
enter more than 10,5
(0.41)