You are on page 1of 4

Source

Pos. Source Product Original request Source description


manufacturer

!!! Phased-out product !!! The


successor product series is 3SK2 (see
FAQ 109741483) SIRIUS safety relay
with relay enabling circuits (EC)
24...240 V UC, 45 mm overall width
1 Siemens 3TK2826-1CW32 3TK2826-1CW32 screw terminal EC instantaneous: 2
NO EC delayed: 2 SC: 3 Switch with 8
functions Basic device Maximum
achievable PL according to EN
13849-1: Maximum achievable SIL
according to IEC 61508: 3

1
Target product Amount Description

SIRIUS safety relay basic unit 3SK2 series 10 F-DI, 2 F-DQ, 1


DQ, 24 V DC Can be parameterized via SIRIUS Safety ES
22.5 mm overall width screw terminal up to SIL 3 (IEC
3SK2112-1AA10 1
62061) up to performance level e (ISO 13849-1) output
expansions 3SK1, coupling relay 3RQ1 and fail-safe motor
starters 3RM1 via device connector connectable

Device connector for 3SK1 safety relay Width 22.5 mm for


+ 3ZY1212-2BA00 1 electrical connection of SIRIUS devices in industrial
standard mounting rail enclosure

SIRIUS safety relay Output expansion 4RO with relay


+ 3SK1211-1BB40 2 enabling circuits 4 NO contacts plus Relay signaling circuit
1 NC contact Us = 24 V DC screw terminal

Device termination connector for 3SK1 safety relay Width


+ 3ZY1212-2DA00 1 22.5 mm for electrical connection of SIRIUS devices in
industrial standard mounting rail enclosure

Device connector for 3SK2 safety relay Width 22.5 mm for


+ 3ZY1212-2GA00 1 electrical connection of SIRIUS devices in industrial
standard mounting rail enclosure

Output coupler with plug-in Relay, 1 change-over contact


+ 3RQ3118-1AM00 1 screw terminal 24 V DC Enclosure width 6.2 mm Thermal
current 6A
Article no. alternative Quantity
Remark
1 alternative 1

You find further information at Industry Online


Support Portal under entry ID: 109741483;
NOTICE: Only 24V DC power supply at A1/A2 of
the 3SK2 basic unit. The 3TK2826 device with
wide voltage range can be replaced only if a 3SK1121-1CB42 1
24V DC voltage source is used to supply the
3SK2 basic unit. Never connect any other
voltage to the 3SK2 basic unit. This would
cause irreparable damage to the equipment.

+ 3SK1230-1AW20 1
Description alternative 1 Remark alternative 1

old: 3TK2826-1CW32
new: -- [standard series]
or
new: 3SK1121-1CB42 + 3SK1230-1AW20 [advanced series]

properties:
old: Us = 24 ... 240V AC/DC, 2S stop category 0 + 2Ö stop category
SIRIUS safety relay Basic unit 1enabling circuit+ 1S + 2Ö signalling circuit
Advanced series with time delay new:
0.5-30 s Relay enabling circuits or
2 NO instantaneous 2 NO new: Us = 24V DC + Us = 110 ... 240V AC/DC, 2S stop category 0 + 2S
delayed Us = 24 V DC screw stop category 1 enabling circuit + 0 signalling circuit, power supply
terminal 3ZY12 needed, because of the basic device of 24V DC

sizes:
old: (45mm x 106mm x 120mm)
new: --
or
new: (22,5mm x 100mm x 121,7mm) + (22,5mm x 100mm x
121,7mm)

SIRIUS safety relay Power


supply for 3SK1 Advanced series
Us = 110-240 V AC/DC screw
terminal