PEUGEOT 307 1.6 HDi 16V DV6TED4 (9HY)


2004 - 2010

Battery: procedures for disconnection/reconnection


Before disconnecting the battery
Close all the doors
Close the windows
Convertible models:
Close the convertible roof
Turn the engine off
Wait for 2 minutes
After disconnecting the battery
When working on pyrotechnic components (e.g. airbags, seat belt pretensioners):
Wait for 5 minutes
After reconnecting the battery
Turn the ignition on
Wait for 1 minute
The engine can be started
Initialising the power windows
Close the driver's window
Press and hold the power window close switch
Until the window is fully closed
Wait for 1 second
Release the switch
Open the driver's window
Press and hold the power window switch
Open the window fully
Release the switch
Press the switch again
Wait for 1 second
Release the switch
Repeat the procedure for the passenger's window
Initialising the remote control
Turn the ignition off and on
Press and hold any button on the remote control to be programmed
Wait for 4 seconds
Turn the ignition off
Remove the key from the ignition switch