Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Variant Standard version
Complementary
Discrete Input Number 7
Discrete Input Type STO safe torque off, 24 V DC, impedance: 1.5 kOhm
DI1...DI6 logic inputs, 24 V DC (30 V)
DI5 programmable as pulse input: 0…30 kHz, 24 V DC (30 V)
Analogue Input Type AI1 voltage: 0...10 V DC, impedance: 30 kOhm, resolution 10 bits
AI2 bipolar differential voltage: +/- 10 V DC, impedance: 30 kOhm, resolution 10 bits
AI3 current: 0...20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by
configuration), impedance: 250 Ohm, resolution 10 bits
Price is “List Price” and may be subject to a trade discount – check with your local distributor or retailer for actual price.
Relay Output Type Configurable relay logic R1A 1 NO electrical durability 100000 cycles
Configurable relay logic R1B 1 NC electrical durability 100000 cycles
Configurable relay logic R1C
Configurable relay logic R2A 1 NO electrical durability 100000 cycles
Configurable relay logic R2C
Maximum Switching Current Relay output R1A, R1B, R1C on resistive load, cos phi = 1: 3 A at 250 V AC
Relay output R1A, R1B, R1C on resistive load, cos phi = 1: 3 A at 30 V DC
Relay output R1A, R1B, R1C, R2A, R2C on inductive load, cos phi = 0.4 and L/R = 7
ms: 2 A at 250 V AC
Relay output R1A, R1B, R1C, R2A, R2C on inductive load, cos phi = 0.4 and L/R = 7
ms: 2 A at 30 V DC
Relay output R2A, R2C on resistive load, cos phi = 1: 5 A at 250 V AC
Relay output R2A, R2C on resistive load, cos phi = 1: 5 A at 30 V DC
Minimum Switching Current Relay output R1A, R1B, R1C, R2A, R2C: 5 mA at 24 V DC
Width 72.0 mm
Height 143.0 mm
Depth 138.0 mm
Environment
Operating Position Vertical +/- 10 degree
Product Certifications CE
ATEX
NOM
GOST
EAC
RCM
KC
Marking CE
ATEX
UL
CSA
EAC
RCM
Electromagnetic Compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to
IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Pollution Degree 2
Packing Units
Unit Type Of Package 1 PCE
Transparency RoHS/REACh
Resource performance
Well-being performance
Mercury Free
Weee The product must be disposed on European Union markets following specific waste
collection and never end up in rubbish bins
Dimensions
Right View, Front View and Front View with EMC Plate
Mounting Types
Connection Diagrams
The logic input switch (SW1) is used to adapt the operation of the logic inputs to the technology of the programmable
controller outputs.
Switch SW1 set to “Source” position and use of the output power supply for the DIs.
Switch SW1 set to “Source” position and use of an external power supply for the DIs.
Switch SW1 set to “Sink Int” position and use of the output power supply for the DIs.
Switch SW1 set to “Sink Ext” position and use of an external power supply for the DIs.
Derating Curves
Derating curve for the nominal drive current (In) as a function of temperature and switching frequency (SF).