The document compares pressure drop for random packing and structural packing, noting that structural packing has half the pressure drop of random packing. It then provides specifications for a distillation column using structural packing, including a column diameter of 0.3m, vapor velocity of 3m/s, and heat requirement of 555088 kcal/hr which will be met by a steam flow rate of 1097 kg/hr at 3.5 kg/cm2g pressure.
The document compares pressure drop for random packing and structural packing, noting that structural packing has half the pressure drop of random packing. It then provides specifications for a distillation column using structural packing, including a column diameter of 0.3m, vapor velocity of 3m/s, and heat requirement of 555088 kcal/hr which will be met by a steam flow rate of 1097 kg/hr at 3.5 kg/cm2g pressure.
The document compares pressure drop for random packing and structural packing, noting that structural packing has half the pressure drop of random packing. It then provides specifications for a distillation column using structural packing, including a column diameter of 0.3m, vapor velocity of 3m/s, and heat requirement of 555088 kcal/hr which will be met by a steam flow rate of 1097 kg/hr at 3.5 kg/cm2g pressure.
Pressure drop 50 mmH2O/m of packing height For structural packing Pressure drop 25 mmH2O/m of packing height
Column diameter 0.3 m
Vapor velocity 3 m/s Volumetric flow rate 764 m3/hr Molecular weight of ethanol+water vapor 75 kg/kmol Mass flow rate of vapor 2558 kg/hr Specific heat of mixture 0.62 kcal/kg C Latent heat of mixture 217 kcal/kg Initial temperature 50 °C Final temperature 78 °C Heat required 555088 kcal/hr Steam pressure 3.5 kg/cm2g Latent heat of steam 506 kcal/kg Steam flow rate 1097 kg/hr