Illaposoii kpan
(Hanmenosanne oGopynopants)
Tun TMBV
SaponcKoii Ne 563301
Tlosuuusa Ne 1
Ball Valve
(Name of equipment)
Type TMBV
Manufacturer serial Ne 563301
Item Ne 1
TIACIIOPT
PASSPORT
LIpu mepenave oGopynonanna ApyroMy RTarenBIy BMEcTe ¢ OGopy7oRaHHeM Meperaetes HacTosITHit
macopt
This passport should follow the equipment if the owner of equipment changes
YEAR 2017Cogepaanue / Table of content
1. OBUIHE YKA3AHHA / GENERAL INSTRUCTIONS ..
2, OCHOBHBIE CBE)(EHHA OB H3/(EJIMH / GENERAL DATA ON EQUIPMENT.
OCHOBHBIE TEXHMYECKHE JAHHBIE / BASIC TECHNICAL DATA,
4, KOMIIEKTHOCTh / COMPLETE SET
5. PECYPCbI, CPOKH CJIYKBbI H XPAHEHHS, TAPAHTHM H3POTOBHTEIA
(MOCTABIIIHKA) / RESOURCES, OPERATING TIME, SERVICE LIFETIME, STORAGE
PERIOD, MANUFACTURER'S (VENDOR’S) WARRANTY .. 8
6, KOHCEPBAIIHA / PRESERVATION. esesenenres ne)
7. CBUETEJIbCTBO OB YMAKOBBIBAHHH / PACKING CERTIFICATE... 10
8. CBH)JETEJIbCTBO O IIPHEMKE / ACCEPTANCE CERTIFICATE.. Tt
9. JBWKEHHE W30ENMA PH 9KCILIYATAUMM / DATA OF THE EQUIPMENT
DISLOCATION DURING OPERATING PERIOD 12
10. PE3YJIbTATbI TEXHMYECKOPO OCBHJETEJIbCTBOBAHHA / RESULT OF
TECHNICAL EXAMINATION ON SITE (DURING WORKING PERIOD) wsessneutsnsneneunnes 15
11, CBE)EHHS1 OB YTHJIM3ALHH / DATA ON DISPOSAL. 16
12, OCOBBIE OTMETKH / SPECIAL REMARKS ..ssssssnatenenes assests LT
13, TEPEYEHb MPHIOXKEHHII / LIST OF ANNEXES, 201. OBU[ME YKA3AHHA / GENERAL INSTRUCTIONS,
1.1. Tepent axcruryaranneli neo6xommMo BHMMaTe:tbHO OSHaKOMHTTECa Co BCel HMeromtelics TEXHHECKOHL
JOKYMenTanelt H HICTPYKIMINH To 9KeTETyaTaruTH OGopysORAHHS. /
All technical dat
and operation manual must be studied before use of equipment.
1.2. Tacnopr jouer noctosimo HaxoquTbes ¢ HaylenHeM. /
Passport must be always kept near the equipment.
1.3. Boe 3anucu 8 nacnopte mpou3B0/MMTb TONBKO MacTaMM WIM YepHHIaMH, OTYeTAMBO H AKKypaTHo. /
All remarks in the passport should be done in a clear manner by pen, not by pencils.
1.4. Henpasuabnas sanMcb jouKHa GEITS aKKypaTHO 3a4epKHYTA H PA/OM 3alIHcaHa HOBas, KOTOpyIO
saRepaeT OTRETCTREHHOE THILO, /
Incorrect records should be carefully crossed out and replaced by a new record which is to be
authenticated by an authorized person.
1.5, Tlocue noanMeH npocragiaior aMWMi0 H MHMLHATM OTBeTeTBeHHOTO THA (EMeCTO HOAMHEH
yonyckaercs npocrapuaTs JH4HBI ITaMM HcHOAHMTeNA). /
The signature is to be completed with a name and position of an authorized person (itis allowable to put a
personal stamp instead of a signature).
1.6. IIpu nepenave wsjlema Ha jipyroe mpesupHarHe HTOrOBEIE cyMMMpyIOMIHe 3%
1MCH 110 HapaGorKe
sanepaior HearbIo MpeANpHXTHA, Hepenaioulero usEAIKe,
The equipment owner should certify all summarizing records by its stamp if the equipment is handed over
to another owner.2. OCHOBHBIE CBEXEHHA OB H3JEJIHH / GENERAL D.
EQUIPMENT
IMlaponoit xpan /Ball Valve
Tosumast Ne 1
Tun TMBV
FLOWSERVE Valbart
Via delle Industrie 9/5
20883 Mezzago (MB) Italy/Hrrama
FLOWSERVE Srl
Via Prealpi 30/32
20032 Cormano (MI) Italy/Hira:ms
563301
12/2017
On-Off
BKOCHO-BEIKTIONCHO
‘Cepruuxar coorsercraus TexHusecKoMy
peraamenry Tamoxenuoro corsa 010/201
Certificate of conformity with technical regulations
of the Customs Union 010/201
TP TC: Ne TC RU C-US.PA02.B.00158
16.11.2015 to 05.03.2020
Eurasian Customs Union
‘Tamoaennstii cows EAC
TP TC 010/2011
«0 GevonachocTH MamuH Ht oGopyxoRaHHs
CU TR 010/201
"On the safety of machines and equipment”3. OCHOBHbIE TEXHMYECKHE JIAHHBIE / BASIC TECHNICAL DATA
Okenayaranuonnste napamerpsr / Operational parameters
Haumenonanue napamerpa / Parameter name
3uasenue / Value
Auaserp wosuiuasansii, DN / Nominal diameter, DN
150mm (6 in)
Tlanacnue HommHambHoe, PN / Nominal pressure, PN
1s00#
PaGouas cpena / Operating fluid
Synthesis gas / Cures
rasa
Pacuernas remmepatypa, °C / Design temperature,
-36 / 80
Tesmmeparypa oxpyxxatomeit cpests, °C / Ambient temperature, °C
uuye / minus 36
Tlonoxkexme mpa orkase (oTkpsit/saKpsit) / Fail position (FO/FC)
nocneguni / Last
Tun upcoeamienus x rpyGouposony / Type of connection to
pipeline
aanen / Flange
Kaace repmerauocri & sarnopa / Class of gate leak tightness
ANSI/FCI 70-2 Cl. IV
Macea, xr / Weight, kg
Hasnasiennetti cpox cnyax6n1, ner / Assigned lifetime, years
203nasenne / Value
Hanmeronanne napamerpa / Parameter name
TIpasox / Drive
Tieamariecknit
‘Tan! Type
Tun / Typ\ Pneumatic!
Vororosuress / Manufacturer FLOWSERVE Limitorque
Italy/Hranns
nocnesini / Last
Hosoxenue pu orkase / Failure position
au / Materials of the main
“Marepnainss, ws KoTopeix wsroTOB.TeHbr ocHOBHIDIE AT
components
A350-LF2
F51+Tung, Carb.
F51+Tung, Carb.
Kopuye pata / Valve body
Barayuuka, map wm waponoii cerment / Plug, ball or ball segment
Cento / Seat4, KOMIIJIEKTHOCTh / COMPLETE SET
Tlaposoit xpan /
TMBV Dall Valve 1 563301 -
Pneumatic
LFPS Actuator / 1 _ -
LPS-15A-385S-D1 Tesmarn-
seckuil upuw0y
‘Dwensryaraunonnas zoxymemranus / Operational documentation
PyxosoneTso no
MOSF pea. 3 sxemuiyaraut /
TMBV MOSF Rev.3 ' - Operating
manual
4.1 Crmcox sanacuprx sacreii: / List of spare parts:
310 TMBV5. PECYPCBbI, CPOKH CJTYXKBbI AH XPAHEHHA, PAPAHTHH
M3POTOBUMTEIA (MMOCTABLIIMKA) / RESOURCES, OPERATING TIME,
SERVICE LIFETIME, STORAGE PERIOD, MANUFACTURER’S.
(VENDOR’S) WARRANTY
Pecype usaems x0 nepsoro
Service time of equipment before first kamuTanssioro/overhaul
(cpeauero, kanmranbxoro / intermediate, overhaul)
pemoura
maintenance =
(uapanerp, xapaxtepusytouit napaSorxy / parameter characterising operating time)
B Teyenne cpoxa cuyx6s1 20 ser, B TOM HuCHe CpoK xpanenua 1 ser (ropa).
during service lifetime 20 years, including 1 years (year) of storage.
(8 Konceppalan (ynaKOBKe) HSFOTOBHTENA B CKIAICKHX TOMEMIEHHAX, Ha OTKPBITHIX MIOULAIKAX Ht
‘ra. / in the manufacturer’s packaging in warehouses or outdoors, and so on).
Mexpemonruntii pecype
Operating time between two maintenances
(uapanerp, xapakrepusyromuii napa6orxy / param:
characterising operating time)
mpi. pemoutre (ax) n TeNenme cpoKa enyaGe1 — ster (roa).
with, = maintenance made during — years (year).
(cpequero, kanuTanbxoro / intermediate, overhaul)
Yeasannbie pecypest, cpoKH cnyXGbI H XpaHCHHa JeHiCTEHTETDHBI NpH coGMoReHAH MoTpeGuTeTeM
rpeGonaHHii elicrayromeli 9KcIyaTaHOHHOH oKyMeHTanHH. /
Specified operating time, service lifetime and storage period are valid only if the final user follows all
requirements of equipment operating documents.
Tapani wsrorosuretx (nocrasmuxa) / Manufacturer’s (vendor’s) warranty
12 months from the commissioning date
18 months from the manufacturing date6. KOHCEPBAI[HA / PRESERVATION
Tara7 | Hanmenonanue paGorss/ Job Cpok aeitersus, Tosrmnocrs,
Date description roget/ Time limit, | @amusma 1 noamuce
years Name of
responsible7. CBAJIETEIbCTBO OB YITAKOBbIBAHHH / PACKING CERTIFICATE
Perysmpyrommii mraponoii kpan / Ball Valve
Haumenonanue usenus / Name of equipment
TMBV. 563301
‘OGosnasenne / Designation BanozeKoH Homep / Manufacturer's serial Ne
‘Ynaxoran (a) / Packed by FLOWSERVE Valbart
Haumenonaxue 1am Koy wsrorosurens / Manufacturer's name or code
corsaeno TpeSonanHaM, nperyemoTpentni B AetieTBYIOMel TexHHTecKoi JOKYMenTanHH. /
in compliance with requirements of current technical documentation.
Tlomanocrs / Position Jhnsas rommacs / Pacummbponxa roammen / Name
Signature in letters
Toa, mecau, sco /
Year, month, date
108. CBAJIETEJIbCTBO O ITPHEMKE / ACCEPTANCE CERTIFICATE
Peryaupytoumii maposoii kpan/ Ball Valve
Hanenonanme n3jemna / Name of equipment
TMBV, 563301
‘OSosnaseaue / Designation Banoackoli omep / Manufacturer's serial Ne
usrotonsen(a) u npunar(a) 8 cooTreteTann c oGmaTensHBIMN TpeSoRaHHaMM rocynapcTReHHDIX
crangapros, selicraytouell rexnMueckoH oKyMeHTaLMeH M mpusian(a) rosuBIM(olt) 114
okcnyaramuu, / has been manufactured and accepted according to the mandatory requirements of the
State Standards and technical documentation in force, and found suitable for operation.
Hasasenk OTK / Head of the quality control department
MIL. (seal) Jiusuiax noxnues / Signature Pacuumposxa nomen / Name
in letters
Tost, Mees, sHcs10/
Year, month, date
Tuapasiuieckoe | nota ~murndurop | Yaoners0-
nemmranmeropmce/ | gs | foppowmn water | pneu!
tase corrosion inhibitor | Satisfactory
Perysmpyronuit maponoit | | #APaRAHYecKOe
ryaupytoutat map, nernrrane noma + nurnGirop | YsoBreTRO~
xpau / Control Ball Valve i“
i yrmorwena / 281 xopposun / water | purest /
aponickoli Homep / Hydraulic test of corrosion inhibitor | Satisfa
Manufacturer's serial Ne | 230" jatisfactory
ue sealing
Thhessaraveoxoe
embrranmne Yaoriters0-
yruiotientia! 035 Bouayx/ Air | purrembuii /
Pneumatic test of Satisfactory
sealing
Tporoxos nermsrrattnii Ne / Test report Ne -
Apyrue wemurranua / Other tests
Functional test -
u9. J[BYOKEHHE H3/JEJIMA TPH IKCILIYATALMH / DATA OF THE
EQUIPMENT DISLOCATION DURING OPERATING PERIOD
9.1, Jewxenne uses npH okertyatanun / Data of the equipment dislocation during
operating period
Tara Tae Tara Hapatoria/ Tipawana | Hoamuce una,
yeranos | yeranossteno/| cusrus/| Operating time custux/ | uposoxmsmero
xut/ Place of | Date of Reason of | yeraopKy
Installat | installation | dismantl | S™"""7" | TOSI’ | dismantling | (cumtue)/
ion date ing | KCNA | Mocsrean Signature of a
anun/ | ero
since the | pemonta performe ra
beginning Fisrieel installation
operation |_repair (dismantling)9.2 Hpuée 1 nepexasa uses / Acceptance and delivery of equipment
Alara
/ Date
Cocrosmme
wsqemas /
Equipment
status
‘Ocnonainite
(saumenosanne,
oMep m sxaTa
moxymentra) / A
reason (name,
number and date
of the document)
‘Company, position, signature 7
TIpeanpustue,
osraHOCT HW HOmIHCE
caapmero / of
delivered
mpunsemero /
of accepted
Tipumesamne/
Remark
139.3 Creaenns 0 saxpevrenmnt u5,ectust ups okciutyatamunn / Data on fixation of equipment
during the exploitation
Haumenosanne | lovxnocts, ‘Ocnonanue (iaumenosanue, Tipumesanne/
seams. amma x | uostep u aara aoxymenra) / A Remark
(cocrasuoi | wnmuama/ | reason (name, number and date of
act) Position, name the document)
oGosnayenue/ | and initials
pemeoy saxpenenue/ | orkpentenue /
equipment fixation deallocation
(part) and
designation
410. PE3YIBTATLI TEXHHYECKOLO OCBHAETEJIbCTBOBAHHA /
RESULT OF TECHNICAL EXAMINATION ON SITE (DURING
WORKING PERIOD)
Vaenrapaxannornesit Ne / Tag number: 1-FV-11002
Banonckoii uosep / Manufacturer serial number: 56027911, CBEJEHHA OB YTHJIM3AIMH / DATA ON DISPOSAL
Decontaminate and clean all the valve parts / Ounerure or sarpasHexnii u mpomstrs nce
sae Kpasia
- Lemuomeranmmeckue jetam (kopryc KpaHa, map, WOK, GomToRBIe KperLieHua) 1
HeMbHOIACTOMEpHBIe TeTATM (YILOTHATENBHBIE KOTbIA) paspenleno nepepaGarsipars
nertocpetcrrenHo / Full metal parts (valve body, sphere, stem, bolting) and full
elastomeric parts (O-rings) can be recycled directly
- Henersnomeranmmieckne eran (cena co RCTABKAMH, BTYNKH, MaHKeTHBIE
yitioTHeHHa) paspeuieHo nepepabarbibath Hocie oTeTeHUA HoaMMepHOH YacrH / Non
full metal parts (seats with seat insert, bushes, lip seals) can be recycled after separating
the polymeric part
1612. OCOBLIE OTMETKH / SPECIAL REMARKS.181913, MEPEYEHS IIPHOXKEHMH / LIST OF ANNEXES
TIPHJIOKEHHE 1 / ANNEX 1: Yeprexn (OGmero sBuza, c6opounnie,
yeranonounsie, jetaamponounere w mpoune) / Drawings (General arrangement
drawings, assembly, installation, detailed and other)
TIPHJIOX%KEHHE 2 / ANNEX 2: Huerpyxuua no mowraxy a oKenayatauun /
Installation and operation manualTIPHJIO7KEHHE 1 / ANNEX 1: Ueprexu (OOmero Bua,
cCOOpOuHbIe, yCTaAHOBOUHEIE, eTAIHPOBOUHIe 4 Npone) /
Drawings (General arrangement drawings, assembly,
installation, detailed and other)TIPHJIOXKEHHE 2 / ANNEX 2: MactpyKuusa 10 MoHTaxy
H 9KcnayaTanun / Installation and operation manual