Professional Documents
Culture Documents
PLEASE SEND THE SOFTCOPY OF ITEM CODE REQUEST TO CDMC THROUGH E-MAIL. ITEM CODE REQUEST RECEIVED DIRECTLY FROM REQUISITIONER SHALL NOT
AUTHORIZED BY HOD HENCE PLS. SEND THROUGH THE MAIL OF HOD ONLY.
* LEAD TIME MEANS EXPECTED TIME FROM DATE OF PR TO DATE OF RECEIPT.
## PLEASE SPECIFY THE DETAILS SEPARATELY IN THE E-MAIL IF "OTHER..." IS SELECTED FOR REASON FOR CODE REQUIREMENT.
From
SIEMENS 3RT2023-1A..0
65 T103 ELECTRICAL
66 T103
JSPL Mozambique Minerais Lda,MATERIAL CODIFICATION TEMPLATE
CENTRAL DATA MANAGEMENT CELL
CEIVED DIRECTLY FROM REQUISITIONER SHALL NOT BE ACCEPTED AS THE ITEM CODE REQUEST NEEDS TO BE
ODE REQUIREMENT.
REQUISITIONER'S CONFIRMATION:
SAP ITEM MASTER DATA CHECKED THOROUGHLY. NO ITEM CODE FOR ANY OF THE FOLLOWING ITEMS EXISTS IN THE SAP SY
Requisitioner's Name: SAURABH (300988)
Dept./ Plant Code: PP/1309
DESCRIPTION: UoM Material
group
TRIP CIRCUIT SUPERVISION RELAY Aux. Supply: 230V AC, 3NO+1NC Contacts, FOR EACH ELESET
CONTROL TRANSFORMER, BURDEN: 2KVA, 415/240VAC, RESIN CAST TYPE. SET
SET
1600A ACB630A
,AIR ACB ,4P EDO
CIRCUIT WITH 1600A
BREAKER, LSIG RELEASE,
3P MDO55kA,
WITH433V
LSIG RELEASE,
55kA, 433V SET
AIR CIRCUIT BREAKER, 1250A 3P MDO WITH LSIG RELEASE, 55kA, 433V SET
MCCB, 800A, 55kA, 3POLE, with O/L & S/C releases SET
SPREDER LINKS SET
RHOM SET
AUXILARY SWITCH SET
TRIP ALARM SWITCH SET
CURRENT TRANSFORMER 800/5A, CORE-1, Cl: 1.0, 10VA SET
Burden, DIA: SUITABLE FOR 2RX50X10
CURRENT TRANSFORMER 1250/5A, CORE-1, Cl: 1.0, 15VA Burden, SET
DIA: SUITABLE FOR 3RX60X10
CURRENT TRANSFORMER 1600/5A, CORE-1, Cl: 1.0, 15VA Burden, SET
DIA: SUITABLE FOR 4RX50X10
MCCB, 630A, 55kA, 3POLE, with O/L & S/C releases SET
MULTI FUNCTION METER ,415V, CL: 1.0, 96Sqmm, SET
AUX SUPPLY: 230V AC, WITH RS485
SHUNT TRIP FOR MCCB SET
SET
MCCB, 400A, 55kA, 4POLE, with O/L & S/C releases
MCCB, 250A, 55kA, 3POLE, with O/L & S/C releases SET
MCCB, 125A, 55kA, 4POLE, with O/L & S/C releases SET
MCCB, 160A, 55kA, 4POLE, with O/L & S/C releases SET
MCCB, 63A, 55kA, 3POLE, with O/L & S/C releases SET
CURRENT TRANSFORMER 63/5A, CORE-1, Cl: 1.0, 10VA Burden, SET
DIA: SUITABLE FOR 1RX20X10
BREAKER CONTROL SWITCH, TNC, 75 Sq mm, 25A SET
AUX CONTACTOR: 230V AC WITH 2NO+2NC SET
SELECTOR SWITCH, 32AMPS, 2POLE, 2-POSITION WITH OFF. SET
LOCAL/REMOTE SELECTOR SWITCH 75SQ mm, 2 POSITION WITHOUT OFF SET
MPCB, 4.5-6.3A, 50kA, with O/L & S/C releases SET
POWER CONTACTOR 12AMPS, 3POLE, AUX SUPPLY 230V AC WITH 1NO+1NC SET
ADD ON BLOCK, 4NO SET
AUX CONTACTOR, AUX SUPPLY:230V AC 2NO+2NC SET
MPCB, 18-25A, 50kA, with O/L & S/C releases SET
POWER CONTACTOR 32AMPS, 3POLE, AUX SUPPLY 230V AC, WITH 1NO+1NC SET
MPCB, 13-20A, 50kA, with O/L & S/C releases, with 1NO+1NC Aux. Contacts. SET
MPCB, 35-45A, 50kA, with O/L & S/C releases SET
POWER CONTACTOR 50AMPS, 3POLE, AUX SUPPLY 230V AC SET
MPCB, 5.5-8A, 50kA, with O/L & S/C releases SET
MPCB, 1.8-2.5A, 50kA, with O/L & S/C releases SET
POWER CONTACTOR 9AMPS, 3POLE, AUX SUPPLY 230V AC WITH 1NO+1NC SET
MCCB, 80A, 50kA, 4POLE, with O/L & S/C releases SET
AIR CIRCUIT BREAKER, 1250A 3P MDO WITH LSIG RELEASE, 55kA, 433V SET
MPCB, 9-12.5A, 50kA, with O/L & S/C releases, with 1NO+1NC
Aux. Contacts. SET
POWER CONTACTOR 32AMPS, 3POLE, AUX SUPPLY 230V AC SET
MCCB, 200A, 3P, 415V AC, 50HZ, 50KA, WITH O/L & S/C
RELEASES SET
MAIN CONTACTOR 150AMPS, 3POLE, AUX SUPPLY 230V AC
WITH 2NO+2NC SET
STAR-DELTA TIMER SET
CT OPERATED OLR RANGE: 63-100A, WITH 1NO+1NC TRIP
CONTACT SET
MCCB, 320A, 55kA, 3POLE, with O/L & S/C releases SET
ADD ON BLOCK, 2NO METER
ADD ON BLOCK, 2NO METER
ADD ON BLOCK, 1NO+1NC NO
DELTA CONTACTOR 265AMPS, 3POLE, AUX SUPPLY 230V AC
WITH 2NO+2NC NO
STAR CONTACTOR 115AMPS, 3POLE, AUX SUPPLY 230V AC
WITH 1NO+1NC NO
SINGLE PHASE PREVENTOR, 3PH, 4WIRE, 145-500VAC, 2C/O NO
CURRENT TRANSDUCER SUITABLE FOR 5A INPUT, OUTPUT 4-
20mA, Cl: 1.0., AUX Supply: 100-230 V AC NO
CURRENT TRANSFORMER 250/5A, CORE-1, Cl: 1.0, 10VA
Burden, DIA: SUITABLE FOR 1RX30X12 NO
OLR RANGE: 100-160A, WITH 1NO+1NC TRIP CONTACT NO
MPCB, 7-10A, 50kA, with O/L & S/C releases
NO
MPCB, 0.14-0.20A, 50kA, with O/L & S/C releases
NO
MPCB, 0.9-1.25A, 50kA, with O/L & S/C releases
NO
POWER CONTACTOR 9AMPS, 3POLE, AUX SUPPLY 230V AC WITH
1NO+1NC NO
CATION TEMPLATE
LL
Select Criticality and Category from following list:
Operational Criticality Application Category
Critical(C) CRITICAL Spare(S) Refractory (R)
Non Critical(NC) Consumable(C) Equipment(E)
Insurance(I) Packing Matl.(P) Stru. Steel(ST)
Raw Mat.(RM) General(GR)
MAXIMUM 10 ITEM PER SHEET
Fuel(F) Prod. Cons.(PC)
e-MAIL OF CDMC IS "cdmc@jspl.com"
Required For (Equip. Reason for Criticality Category Rate Import/ Ind.
Code) Code Requirement ## C/NC/I S/C/P/R/E/F (Rs.)
Lead
Time*days
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
KALPA/
ELECTRICA SRESTAA
KALPA/ ADD ON BLOCK,
ELECTRICA SRESTAA C2 4NO
KALPA/ 3RH2911-1FA40 ADD ON BLOCK,
ELECTRICA SRESTAA 4NO
KALPA/ 3RT2027-1A..0 POWER
SRESTAA CONTACTOR
32AMPS,
3POLE, AUX
SUPPLY 230V
AC
ELECTRICA
KALPA/ CURRENT
SRESTAA TRANSFORMER
100/5A, CORE-
1, Cl: 1.0, 10VA
Burden, DIA:
SUITABLE FOR
1RX15X10MM
ELECTRICA