Are You Ready for EN55035? The New Standard for EU RED
Directive

The new EU standard EN55035, which may replace the existing multi-media
equipment applicable standards EN55020 and EN55024 and their
amendments, has been included in the RED official journal on December 15,
2017.

The new EU standard EN55035 has been included in the RED official journal on December 15, 2017 for radio
broadcast receiver, i.e. AM/FM/DAB radio.
What is the difference of the standard comparing with EN55020 and EN55024? Let Intertek Hong Kong quickly and
accurately show you to understand EN55035.

EN55035 Applicable Product Range:


Multimedia equipment standards include the former EN55020 (AV) products and EN55024 (ITE) products, also
include professional use multimedia products.
EN55035 Detail Test Requirements:
The EN55035 test requirements are not a simple overlay of the EN55020 and EN55024 test requirements. Here,
let’s clearly understand EN55035 by comparing the requirement differences of the key test items:

1. Test item with the same test requirements of EN55020 and EN55024:

Test Requirements Comparison


Test
Item
EN 55035 EN 55020 EN 55024

+/-4KV for Contact discharge +/-4KV for Contact discharge +/-4KV for Contact discharge
ESD +/-8KV for Air discharge 10 of +/-8KV for Air discharge 10 of +/-8KV for Air discharge 25 of
each polarity each polarity each polarity

2. Test items with different test requirements of EN55020 and EN55024:

Test Requirements Comparison


Test Item
EN 55035 EN 55020 EN 55024

80MHz-1000MHz
R/S 900MHz,
1800MHz, 2600MHz, 3500MHz, 80MHz-1000MHz
790-862MHz
5000MHz

+/-1KV for ac mains port Only +/-1KV +/-1KV for ac mains port
EFT +/-0.5KV for analogue/ digital data for ac mains +/-0.5KV for analogue/ digital
ports and DC network power port port data ports and DC power port

Surge  unshielded symmetrical port N/A signal ports and


1KV for without primary telecommunication ports:
protection in place
 4KV for the primary
protectors fitted  1KV for without
 0.5KV for coaxial or shielded primary protection in
signal port place
 DC network power port:  4KV for the primary
0.5KV protectors fitted
 AC Mains power port: 1KV  DC power port: 0.5KV
for line to line; 2KV for Line  AC Mains power port:
1KV for line to line;
to earth 2KV for Line to earth

0.15MHz-10MHz: 3V
CS 10MHz-30MHz: 3V to 1V N/A 0.15MHz-80MHz: 3V
30MHz-80MHz: 1V

Power frequency
1A/m N/A 1A/m
magnetic field

Residual voltage: < 5% Residual voltage: < 5%


Number of cycles 0.5 Number of cycles 0.5
Voltage dips & Short
interruptions - Voltage Residual voltage: 70% N/A Residual voltage: 70%
dips
Number of cycles: 25 for 50 Hz; 30 for Number of cycles: 25 for 50 Hz;
60 Hz 30 for 60 Hz

Voltage dips & Short Residual voltage: < 5 Number of


Residual voltage: < 5 Number of
interruptions - Voltage N/A cycles: 250 for 50 Hz, 300 for 60
cycles: 250 for 50 Hz, 300 for 60 Hz
interruptions Hz

3. EN55035 New test items:

Test Requirements Comparison


Test Item
EN 55035 EN 55020 EN 55024

0.15MHz to 0.5MHz
107dBuV;
Broadband impulse noise disturbances, repetitive
0.5 MHz to 10MHz;
- Impulse Frequency N/A N/A
107dBuV to 36dBuV;
Test level 10 to 30MHz
36dBuV to 30dBuV

Intertek Hong Kong has upgraded our testing equipment to establish for EN55035 test, providing you the
professional and fast EN55035 testing and certification services for your audio, video and IT & communications
products.