Professional Documents
Culture Documents
:_____________
10
TLE/EIM 10
Quarter 4 – Module 7
Competency: Perform roughing-in activities, wiring and cabling works for single-
phase distribution, power, lighting and auxiliary systems
1
Lesson Proper
BRIEF INTRODUCTION
An Electrical Metallic Tubing conduit is a thin walled conduit that is constructed to be
bend with hand benders. This type of wiring installation is designed to lessen or eliminate fire
hazard and electrical accident. The following rules and regulations on the use of electrical
metallic tubing should be observed:
The following rules and regulations on the use of electrical metallic tubing should be observed:
A. Application. Electrical metallic tubing may be used for exposed and concealed work at the
same condition with rigid metal conduit. EMT protected with enamel should not be used on the
following conditions:
c. hazardous location
D. Under wet location. Electrical metallic tubing can be used provided the water is prevented in
entering the conduit. The support, straps and other fitting must be approved for the purpose.
E. Number of conductors in tubing. The number of conductors for every single run of EMT
should follow the given table.
2
A. TYPES OF EMT BOXES
3
B.TYPES OF BENDS
The PEC requires a maximum of four adapter bends for every one run of tubing
4
Analyses:
Write the correct procedure on how to make elbow bend. Write the number on the space
provided.
Performance Activity 1
Directions: Using the given wiring plan below, list down all electrical fittings to be
used in accomplishing the task. Write your answer on the space provided.
ONE BULB CONTROLLED INTO TWO LOCATION USING TWO THREE WAY SWITCHES
_______________________________________________________________________________________
_______________________________________________________________________________________
_______________________________________________________________________________________
_______________________________________________________________________________________
_______________________________________________________________________________________
_______________________________________________________________________________________
_______________________________________________________________________________________
5
Performance Activity 2
ACTIVITY 1: Name the following electrical materials (10 pts.)
Assessment:
Directions: Read and analyse the questions carefully. Encircle the letter of your choice.
1. What do you mean by the acronym EMT?
A. ELECTRIC METAL TUBING B. ELECTRICAL METALLIC TUBE
C. ELECTRICAL METALLIC TUBING D. ELECTRICITY METALLIC TUBE
2. Which type of metal conduit is designed to lessen or eliminate fire hazard?
A. EMT B. FMC C. PVC D. RMC
3. It is a tool used to bend a metallic conduit.
A. hacksaw B. hammer C. heat gun D. hickey
4. The allowable number of quarter bends which can be done in a one run of electrical metallic conduit.
A. 2 B. 3 C. 4 D. 6
5. Which type of bend is used to adopt the conduit from the surface to a particular box or fitting?
A. bending B. offset C. quarter bend D. saddle
6. Which tool is used to remove the sharp edge on the pipe after cutting?
A. hammer B. pliers C. reamer D. screw driver
7. Which tool used to cut electrical metallic tubing?
A. chisel B. file C. pipe cutter D. plier
8. A type of fitting which is used to secure EMT to metallic boxes.
A. clamp B. connector C. coupling D. straps
9. A 90 degree angle bend fitting commonly used to make quarter bend.
A. elbow B. fitting C. offset D. saddle
10. What is the size of the conduit which can accommodate a maximum of 10 conductors # 12 AWG?
A. 1/2 B. 3/4 C. 1 D. 1 ½