EIMT NCII SET__B____

Name ______________________________ Score___________

1. There are sheet metal troughs with hinged or removable covers for housing and
protecting electrical wires and cables and in which conductors are laid in place.

A. Bus ways

B. Wire ways

C. Cable ducts

D. Cable trays

2. Most of the required electrical parameters apply to an incandescent bulb are

A. Rated power and rated voltage

B. Rated resistance and rated current

C. Rated current and rated voltage

D. Rated power and rated current

3. When tightening a terminal screw connection, the end of the wire should pass around
the screw in the same direction as the screw is turned so that

A. the wire will act as locknut

B. any full on the wire will tighten the screw

C. the wire will not turn off

D. the screw can be removed more easily

4. A part providing an appropriate degree protection of equipment against contains external


influences and defined degree of protection again contacts with live parts any direction.
A. Cabinet

B. Enclosure

C. Panel board

D. Switch gear

5. Locknut , bushing and connectors are called electrical_______________

A. Conduit

B. Fittings

C. Expander

D. Tighteners

6. Why is if necessary to use torque wrench in tightening bottled joints of copper bus bars
inside bus ducts and bus ways?

A. To prevent heating of joints

B. To reduce the resistance in the joint

C. To make sure the joints are well tightened

D. To give the bolt allowance for thermal expansion

7. What is the commonly used conduit in Service Entrance?

A. PVC

B. EMT

C. RSC/RMC
D. Flex Conduit

8. What is the types of fitting commonly used for exposed conduit support?

A. Conduit strap/Clamp

B. Condulet

C. Connector

D. Lock nut and bushing

E.

9. When raceways are exposed to widely different temperatures it should be


_____________.

A. Sealed

B. Bonded

C. Grounded

D. Isolated

10. Before adding to or altering an installation, you must ensure that____________.

A. You are well familiar with the existing installation.

B. Such work will not impair any part of the existing installation

C. Safety precautions are followed

D. All of the above


11. What will you do if the load schedule reflects a 20AT/2.0 sq.mm. Lighting Branch
of which breaker is over rated?

A. Wait for your superior and let him do the corrections.

B. Look for another load schedule and check for differences.

C. Look for the wiring layout and check groupings.

D. Change rating to 15AT to conform with PEC requirement

12. The size of circuit breaker to be used in 40 A motor full load current is

A. Not less than 125% of the full load

B. More than 115% of the full load

C. Less than 50AT

D. Equal to 100AT

13. The selection requirements for circuit breaker are

A. Ampacity, rated power and rated voltage

B. Ampere Frame, Ampacity and Kilo Ampere Interrupting Capacity

C. Kilo Ampere Interrupting Capacity, Ampere Trip and Ampere Frame

D. Ampere Frame, Full load Current and Rated voltage


14. When measuring load current, the ammeter is connected_________

A. Parallel with the source

B. In series with the load

C. Across the terminals of the load

D. From one load terminal to ground

15. The material used in long length bus bar joints to give allowance for thermal expansion
is____________

A. Annealed soft drawn copper

B. Solid copper plates

C. Flexible braided copper plates

D. Flexible copper plates

16. The current is directly proportional to the voltage and inversely proportional to
resistance.

A. Lenz’s Law

B. Power Law

C. Faraday’s Law

D. Ohm’s Law
17. Before adding to or altering an installation, you must ensure that

A. Partially tightened

B. Loosely installed

C. Safety precaution are followed

D. The power is alive

18. What amount of current will be drawn by incandescent bulb connected to a 115-volt
circuit if its resistance is 264.5 ohms?

A. 0.45 amps.

B. 0.43 amps.

C. 0.42 amps.

D. 2.3 amps.

19. When measuring ballast resistance if it is defective o good, it is necessary that the
source.

A. Energized

B. de-energized

C. unloaded

D. loaded

20. A circuit breaker is an electrical protective device which_________


A. Protects electrical equipment from incoming spike voltage

B. Protects electrical equipment from current surges and on

C. Breaks power flow when a very low voltage is encounter

D. Trips off when a very low current is encountered

21. The 24 hours protection from home and commercial building to monitor and access
the video any time anywhere on this device.

A. Fire alarm system

B. Building Remote Controller

C. Telephone monitoring Cabinet

D. CCTV Camera

22. The Auxiliary device of CCTV that monitor the motion daily.

A. Camera

B. Recorder

C. Monitor

D. Adapter

23. Which of the following is the input device


A. Door Lock

B. Exit Button

C. Biometric Reader and Controller

D. All of the above

24. A part Auxiliary device that capture live events and save as video files

A. Power splitter

B. Camera

C. Monitor

D. Recorder

25. The minimum size of conduit commonly used in laying-out of Auxiliary Devices

A. ½” diameter

B. ¾” diameter

C. ½” PVC molding

D. ¾” PVC molding
26. An electricians should always have his tools in good working condition, the most
important reason being is__________

A. You have to exert more effort when using defective tools.

B. Your job cannot be satisfactory done without good tools

C. It is part of your job to keep tools in good working condition

D. Defective tools can cause accidents or damage to equipment

27. What type of hand tools commonly used in boring of ½” diameter hole in panel board

A. Cold Chisel and a hammer

B. Hacksaw and Hammer

C. Knock out Puncher and Adjustable Wrench

D. Hand drill

28. It is the connection between the grounded circuit conductor and the equipment
grounding conductor at the service.

A. Bonding jumper

B. Grounding electrode conductor

C. Bounding jumper, main

D. Bonding jumper, equipment

29. What is the fitting commonly used for tightening between the boxes the RSC conduit?
A. Straight Connector

B. Condulet

C. Conduit strap

D. Lock nut and bushing

30. Part of the Auxiliary System that set the motion-trigger action individually for each
camera.

A. Live Previewing

B. Recording

C. Camera Scheduled

D. Motion detection

Test II SET ______A____

1. A kind of diagram that is used in designing or troubleshooting electrical installation


control equipment so arranged to facilitate the tracing of the circuit.

A. Wiring diagram

B. Schematic diagram

C. Pictorial drawing

D. Electrical lay-out

2. Which of the following electrical parameters apply or labelled to all kind of awitches?
A. Rated power and rated voltage

B. Rated resistance and rated current

C. Rated current and rated voltage

D. Rated power and rated current

3. When tightening a terminal screw connection with the splice wire, the end of the splice
wire should pass around the screw in the same direction as the screw is turned, so
that_________

A. The wire will act as a locknut

B. Any pull on the wire will tighten the screw

C. The wire will not turn off

D. The screw can be removed more easily

4. One most advantage of using rubber insulation tape in splice is __________

A. Does not deteriorate with age

B. Is able to withstand high temperature

C. Does not absorb much moisture

D. All of the above

5. Locknut, bushing and connectors are called electrical________

A. Conduit

B. Fittings
C. Expander

D. Tighteners

6. What is commonly used conduit in Service Entrance?

A. PVC

B. EMT

C. Flex Conduit

D. RSC/IMC

7. What do you call a fitting resembling a pipe with a removable cover access to electric conduit?

A. Conduit strap/Clamp

B. Condulet

C. Connector
D. Lock nut and bushing

8. The box use for convenience outlet is

A. Splice Box

B. Full Box

C. Square Box

D. Utility Box

9. A mechanical connector that is crimped unto a conductor for both splice and termination is
known as

A. Split bolt connector

B. Solderless connector

C. Mechanical lug

D. Bolt connector

10. Commonly used adhesive materials for joining of PVC conduit

A. PVC Cement

B. PVC Solvent

C. PVC Varnish

D. PVC Adhesive
11. The size of circuit breaker to be used in 40 A motor full load current is

A. Not less than 125% of the full load

B. More than 115% of the full load

C. Less than 50 AT

D. Equal to 100AT

12. A live duplex wire can be de-energized quickly and safely by cutting ______.

A. Across with an electrical pliers

B. Across using a mechanical pliers

C. One-by-one with knife

D. One-by - one using diagonal cutter


13. When measuring load current, an ammeter is connected__________.

A. Parallel with the load

B. In series with the load

C. Across the terminals of the load

D. From one load terminal to ground

14. When measuring load resistance, the ohmmeter is connected_______.

A. Parallel with the source

B. In series with the load

C. Across the terminals of the load

D. From one load terminal to geround

15. What is the Ampacity of #8.0 sq.mm. THW wires?

A. 35 amperes

B. 20 amperes

C. 25 amperes

D. 50 amperes
16. What will you do if the load schedule a 20AT/2.0-sq.mm.Lighting Branch Circuit of which
circuit breaker is over rated?

A. Wait of your superior and let him do the corrections.

B. Look for another load schedule and check groupings.

C. Look for the wiring layout and check groupings.

D. Change rating to 15AT to conform with PEC requirement

17. What amount of current will be drawn by incandescent bulb connected to a 115-volt circuit if
its resistance is 264.5 ohms?

A. 0.45 amps.

B. 0.43 amps.

C. 0.42 amps.

D. 2.3 amps.
18. When measuring ballast resistance if it is defective or good, it is necessary that the source

A. Energized

B. De-energized

C. Unloaded

D. Loaded

19. A circuit breaker is an electrical protective device which _____________.

A. Protects electrical equipment from incoming spike voltage

B. Protects electrical equipment from current surges and overloads

C. Breaks power flow when a very low voltage is encountered

D. Trips off when a very low current is encountered

20. It is the connection between the grounded circuit conductor and the equipment grounding
conductor at the service.

A. Bonding jumper

B. Grounding electrode conductor

C. Bonding jumper, main

D. Bonding jumper, equipment


21. Which of the following is an output device

A. Emergency Break Glass

B. Exit Button

C. Biometric Reader and Control

D. Magnetic Lock

22. The technical term for the type THW wires mostly is industrial wirings is

A. PVC Insulated Heat Resistant

B. Moisture and Heat resistant thermoplastic

C. Poly Vinyl Chloride

D. Plastic Covering
23. Which of the following is the input device

A. Door Lock

B. Exit Button

C. Biometric Reader and Controller

D. All of the above

24. When skinning a small wire, the insulation should be “ pencil down” rather that cut squire to

A. Prevent the braid from fraying

B. Saves time in making the splice

C. Allows more insulation in the splice

D. Decrease danger of nicking the wire

25. The minimum size of conduit commonly used in laying-out of Auxiliary Devices

A. ½” diameter

B. ¾” diameter

C. ½” PVC molding

D. ¾” PVC molding
26. An electricians should always have his tools in good working condition, the most important
reason being is ______

A. You have to exert more effort when using defective tools

B. Your job cannot be satisfactory done without good tools

C. It is part of your job to keep tools in good working condition

D. Defective tools can cause accidents or damage to equipment

27. What type of hand tool commonly used in boring of ½” diameter hole in a panel board

A. Cold chisel and a hammer

B. Hacksaw and Hammer

C. Knock out Puncher and Adjustable Wrench

D. Hand drill
28. There are sheet metal troughs with hinged or removable covers for housing and protecting
electrical wires and cables and ion which conductors are laid in place.

A. Bus ways

B. Wire ways

C. Cable ducts

D. Cable trays

29. What are the types of fitting commonly used for tightening between the boxes and the
conduit?

A. Straight Connector

B. Condulet

C. Conduit strap

D. Lock nut and brushing

30. The box use for typical switches

A. Splice box

B. Full Box

C. Square Box

D. Utility Box
Set C

1. C

2. B

3. B

4. B

5. C

6. C

7. B

8. a

9. B

10. B

11. B

12. D

13. C

14. D

15. b

16. c

17. C

18. C

19. B

20. B
21. D

22. A

23. B

24. D

25. B

26. D

27. D

28. A

29. D

30. B