Professional Documents
Culture Documents
Loop-AM3440
Access DCS-MUX
AM3440-A
Description
The Loop-AM3440-A/B/C series products are Access
DCS-MUXs which support multiplexing of various digital
access interfaces into E1 or T1 lines for convenient
transport and switching. The Loop-AM3440 Access
DCS-MUX provides access for a variety of TDM, packet,
AM3440-B and voice interfaces detailed on the next page. These
interfaces are compatible with other Loop products. The
AM3440 can act as a mini DACS: one or more of the
WAN ports can be used as a Drop & Insert function with
fractional E1/T1 lines, which can be muxed into a full
E1/T1 line. Furthermore, the AM3440 also supports TDM
AM3440-C circuit emulation protocols. TDM data and voice services
can be encapsulated as Pseudowires and transported
over ETH/IP/MPLS packet switch networks.
The AM3440 controller module provides full non- blocking
Nx64K cross-connect matrix up to 2048 DS0. System
Features redundancy is available in dual controller and power
Full frontal access (ETSI) Shelf modules, making it an excellent fit for critical applications.
DACS (Digital Access Cross-Connect System) with full While 1+1 link protection is available for E1, T1, and
non-blocking nx64K (DS0) cross-connect support Dual TDMoEA modules, path protection for end-to-end Nx64K
controller, dual power with load sharing circuit protection is available for 3E1/T1.
E1/T1/TDMoEA 1+1 protection, switching time <50ms
The AM3440 supports local control and diagnostics by
DS0 Level Nx64K circuit protection using a VT-100 terminal connected to the console port. It
PDH ring protection, QE1/QT1, FOM, Mini QE1/QT1 supports Ethernet, Telnet, and SNMP, so that it can be
Console, Telnet, and Inband management support controlled and diagnosed from remote ends. An in-band
SNMP v.1 and v.3 management channel with GUI is available as well.
Craft interface port for connection to external Intelligent Each of the 3 models of AM3440-A, B, and C has a
Front Panel number of plug-in slots in regular size and mini size. (Card
Compatible to a SNMP based GUI network management size to slot compatibility is detailed on the next page.)
system and supported by Loop iNET and Loop iNMS Most of the plug-in cards have LED indications.
Three chassis types available: AM3440-A, AM3440-B,
AM3440-C The AM3440 consists of a rugged reinforced aluminum
chassis, giving this equipment a durable structure and a
Support SAToP(CCPA T1 SAToP*), CESoPSN, and
long-lasting physical life.
MEF8 for emulation of TDM circuits
* Future Option
1
Loop-AM3440 Access DCS-MUX Multi-Services Cross Connect
3-channel E1 # #
3-channel T1 # #
4-channel E1
4-channel T1
2-channel G.SHDSL (2 pairs) w/o line power
4-channel G.SHDSL (1 pair) w/o line power
8-channel G.703 card at 64 Kbps data rate
8-channel Dry Contact I/O Type
8-channel Dry Contact I/O Type B
8-channel 2W/4W E&M (8E&M) D D D
8-channel 2W/4W E&M (8E&MA)
12-channel FXS D D D
12-channel FXSA
12-channel FXOA
Single-Slot 12-channel Magneto
1-channel low speed optical (C37.94)
4-channel low speed optical (C37.94)
8-channel RS232 with X.50 subrate
6-port RS232 card (6RS232A) with V.110
encoding
8-LAN-port/ 64-WAN-port Router-B
4-channel TDMoEA
8-channel Data Bridge
1FOMA
6-channel UDTEA
8-channel UDTEA
8-channel OCU-DP
6-channel Co-Directional card (6CDA)
VOIPGA interface card
Dual-Slot Transfer Trip card (TTA)
2
Loop-AM3440 Access DCS-MUX Multi-Services Cross Connect
Note: = Supported # = Supported by Chassis CHAJ, CHAK and CHCJ only D =Discontinued
= Not Supported ## = Supported by Chassis CHAK only * = Future Option
Controller
CCB CCPA
Function
LCDNote
DB9 console Note
USB console
3
Loop-AM3440 Access DCS-MUX Multi-Services Cross Connect
Ordering Information
To specify options, choose from the list below:
Notes:
1. RoHS compliant units are identified by the letter G appearing at the end of ordering code.
2. AM3440 chassis types:
AM3440-A: 5U chassis with 128 Mb/s cross-connect capacity backplane.
AM3440-B: 2.5U chassis with 56 Mb/s cross-connect capacity backplane.
AM3440-C: 3U chassis with 72 Mb/s cross-connect capacity backplane.
AM3440-D: 2U chassis with 72 Mb/s cross-connect capacity backplane. Support Mini Plug-in Modules only.
Please refer to separate AM3440-D brochure.
Loop-ACC-CAB-HDB15M-25-DB09F-G is
included for Console/LCD Interface
connection.
Loop-AM3440-CCPA-mgmt- Packet controller module, support Loop-ACC-CAB-HDB15M-100-RJ48M-G is
G cross-connect function and two physical applicable to use with Clock interface
Combo GbE (SFP/RJ45) interface for TDMoE connection. Please order conversion cable
uplink. One USB console port and one RJ45 separately.
SNMP port on board.
Supports SAToP (CCPA T1 SAToP*),
CESoPSN, and MEF-8
Up to 64 Pseudowires
Supports SyncE
Loop-AM3440-CCPA-NPW- Packet controller module with two Combo Loop-ACC-CAB-HDB15M-100-RJ48M-G is
mgmt-G* GbE (SFP/RJ45) interface, one USB console applicable to use with Clock interface
port and one RJ45 SNMP port on board. connection. Please order conversion cable
Supports SyncE separately.
Where mgmt is used to select the following functions. Please replace mgmt with your selection, or leave it blank for
nothing.
4
Loop-AM3440 Access DCS-MUX Multi-Services Cross Connect
Limited Quantity
Loop-AM3440-1X21-G 1-channel X.21 plug-in card
Loop-AM3440-1RS232-G 1-channel RS232 plug-in card
Loop-AM3440-1V35-G 1-channel V.35 plug-in card
Loop-AM3440-1E530-G 1-channel EIA530 plug-in card
Loop-AM3440-QEMA-wr-m-Tn Jumper selectable: 2/4 WIRE; A/B side
For AM3440-CHAK, CHB, CHC and CHCJ
-x-G Quad E&M voice card, complied with only
IEEE1613 standard. For wr, m, n and x option, please refer to the
table below for detail information
Loop-AM3440-QMAGA- G Quad channel magneto plug-in module with For AM3440-CHAK, CHB, CHC and CHCJ
ring across L1&GND and L1&L2. Software only.
programmable.
Please use with 100-240Vac or ±48Vdc
powered main units.
Loop-AM3440-QFXO-x-G Quad FXO voice plug-in card For AM3440-CHAK, CHB, CHC and CHCJ
Loop-AM3440-QFXO-M-x-G Quad FXO with MP 16 KHz voice plug-in only
card
Loop-AM3440-QFXO-M12-x-G Quad FXO with MP 12 KHz voice plug-in GS = Ground Start
card
Loop-AM3440-QFXO-GS-x-G Quad FXO with GS plug-in card MP = Metering Pulse Receive
Loop-AM3440-QFXO-GM-x-G Quad FXO with GS and MP 16 KHz voice 12/16 KHz
plug-in card
For x option, please refer to the
Loop-AM3440-QFXO-GM12-x- Quad FXO with GS and MP 12 KHz voice table below for detail information
G plug-in card used with 4 RJ11
QFXO-GM includes all QFXO card functions
For AM3440-CHAK, CHB, CHC and CHCJ
Loop-AM3440-QFXSA-x-pt-G Quad FXSA voice card only
Loop-AM3440-QFXSA-M-x-pt- Quad FXSA with MP 16KHz voice card Jumper setting options: Loop Start, Ground
Start (GS), Metering Pulse Transmit 12/16
G
5
Loop-AM3440 Access DCS-MUX Multi-Services Cross Connect
6
Loop-AM3440 Access DCS-MUX Multi-Services Cross Connect
Limited Quantity
Loop-AM3440-8RS232-RJ-G 8-port RS232 plug-in card with X.50
subrate multiplexing scheme and X.54
encoding, with 8 RJ48 connectors for 8
RS232 Async ports
Loop-AM3440-8RS232-DB-G 8-port RS232 plug-in card with X.50 Two conversion cables are included (DB44
subrate multiplexing scheme and X.54 connector to two DB25 and one DB9
encoding, with 2 RJ48 connectors and 2 connector; (Loop-ACC-CAB-DB44M-100-
DB44 connectors for Async and Sync ports 2DB25F-1DB09F-DB).
6-port RS232 card with V.110 encoding, This card can be used in AM3440-A/B/C
Loop-AM3440-6RS232A-RJ-G with 6 RJ48 connectors for 6 RS232 Async only.
ports
6-port RS232 card with V.110 encoding, This card can be used in AM3440-A/B/C
Loop-AM3440-6RS232A-DB-G with 2 DB44 connectors for Async and only.
Sync ports
Two conversion cables are included, DB44
connector to two DB25 and one DB9
connectors.
(Loop-ACC-CAB-DB44M-100-2DB25F-
1DB09F-DB)
Loop-AM3440-8DBRA-RJ-G 8-channel data bridge plug-in card, with 8
RJ48 connectors for 8 data bridge Async
ports
Loop-AM3440-8DBRA-DB-G 8-channel data bridge plug-in card, with 2 Two conversion cables are included (DB44
RJ48 connectors and 2DB44 connectors connector to two DB25 and one DB9
for 8 data bridge Async ports connector; (Loop-ACC-CAB-DB44M-100-
2DB25F-1DB09F-DB).
Loop-AM3440-1FOMA-opt-G 1FOMA Fiber Optical Interface with 1x9 For opt option, please refer to the table
optical port below for detail information
For controller hardware version F and
software version V8.15.01 or newer
versions.
Loop-AM3440-RTB-G 8-LAN ports/64 WAN ports router/bridge For controller hardware version F and
plug-in card software version 6.05.02 or newer versions.
Loop-AM3440-8EMA-x-pt- 8-channel 2W/4W E&MA plug-in card pt = power type
typ-G For x, pt and typ options, please refer to the
table below for detail information
Loop-AM3440-12FXSA-sn-pta-t 12-channel FXSA plug-in card with 12FXSA-GMP includes all FXS card
yp-G 600/900 Impedance, Battery Reverse, functions
Loop Start and PLAR. Without Ground
Start and Metering Pulse. Used with 12 For sn option, please refer to the table below
RJ11. for detail information
Loop-AM3440-12FXSA-P-sn-pta 12-channel FXSA plug-in card with
-typ-G 600/900 Impedance, Battery Reverse, pta= power type.
Loop Start, PLAR and [PLAR bit
programmable]. Without Ground Start and For pta option, please refer to the table
Metering Pulse. below for detail information
Used with 12 RJ11.
The IEEE1613 standard applies to
Loop-AM3440-12FXSA-M-sn- 12-channel FXSA plug-in card with AM3440-A/C only
pta-typ-G 600/900 Impedance, Battery Reverse,
Loop Start, PLAR and [Metering Pulse].
Please use with 100-240Vac or ±48Vdc
Used with 12 RJ11.
7
Loop-AM3440 Access DCS-MUX Multi-Services Cross Connect
Loop-AM3440-VoIPGA-pt-G VoIP Gateway card with 1 WAN and 2 LAN For AM3440-A/B/C
10/100Base-T interfaces. Supports up to
60 voice channels. For AM3440-CCB controller only
Support G.711 a/mµ-law, G.726-32K,
G.729 and G.723.1 voice compression For the pt option, please refer to the table
formats below for details
SIP compliant.
8
Loop-AM3440 Access DCS-MUX Multi-Services Cross Connect
Loop-AM3440-6UDTEA-G 6-port universal data interface card that No conversion cable is included. Please
supports three software configurable order conversion cable separately from
modes: below table.
Port 1 to 4: two DB44 connectors Six conversion cable types are available:
Port 5 to 6: two RJ48 connectors - Loop-ACC-CAB-DB44M-100-2DB25F-
VB
Mode 1: - Loop-ACC-CAB-DB44M-100-2DB15F-
Port 1 to 4: RS232/RS422/X.21, VB
Async/Sync 64kbps and subrate with - Loop-ACC-CAB-DB44M-100-1DB15F-
V.110 encoding 1DB25F-VB
- Loop-ACC-CAB-DB44M-100-2M34F-V
Port 5 to 6: RS232 for ASYNC only B
Mode 2: - Loop-ACC-CAB-DB44M-100-2DB37F-
VB
Port 1 to 4: X.21/RS422 SYNC N*64k - Loop-ACC-CAB-DB44M-100-1DB37F-
(N=1~32) 1M34F-VB
Port 5 to 6: Disabled
Mode 3:
Port 1 to 3: X.21/RS422 SYNC N*64k,
(N=1~32).
Port 4: X.21/RS422 SYNC, N*64k,
(N=1~20).
Port 5 to 6: RS232 N*64k (N=1~6)
oversampling for ASYNC data.
Mode 4:
Port 1 to 4:
RS232/RS422/X.21/V.35/V.36/EIA53
0 SYNC 38.4K and subrate
Port 5 to 6: Disabled
Mode 5:
Port 1 to 4:
X.21/RS449/RS422/RS232/V.35/V.3
6/EIA530 SYNC N*64k (N=1~32)
Port 5 to 6: Disabled
Loop-AM3440-6CDA-cdm-G 6-channel G.703 Interface at 64 Kbps For cdm option, please refer to the table
data rate. Per port configurable for below for detail information.
Co-directional or Contra-directional
interfaces.
9
Loop-AM3440 Access DCS-MUX Multi-Services Cross Connect
Accessories
Model Description Note
Power Module
For AM3440-CHA only
Loop-AM3440-SD125-G Single -125 Vdc (-40 to -150 Vdc) Power
Module (100W) for AM3440-A only For shared redundancy, order 2 single DC
10
Loop-AM3440 Access DCS-MUX Multi-Services Cross Connect
*Future option
11
Loop-AM3440 Access DCS-MUX Multi-Services Cross Connect
12
Loop-AM3440 Access DCS-MUX Multi-Services Cross Connect
Where m is used to select QEM card signaling side (must select one):
m= Description Note
B B (carrier side) connects to A side.
A A (exchange side) connects to B side. A side M lead to B side M lead, A side E
lead to B side E lead.
Where n is used to select QEM card signaling type (must select one):
n= Description Note
O For voice transmission only. Circuit Type doesn’t matter.
1 Type I (Original) E&M Signaling Circuit M lead provides discharge for
the A side.
13
Loop-AM3440 Access DCS-MUX Multi-Services Cross Connect
2 Type II Circuit. This design attempts to reduce ground noise by adding two Reduced ground noise.
leads: SB (Signal to Battery) and SG (Signal to Ground) Ground current is eliminated
at the cost of two more wires
per circuit.
Type III Circuit. The SG lead serves as a discharge for the M lead. Reduces Type III is rare because
3 delay caused by combination of (a) low current electronic detectors, and (b) ground currents on the E
long runs of the E and M leads. return would cause noise
Type IV Circuit. Based on the Type 2 circuit. This E&M circuit provides
4
symmetry.
Type V Circuit. For applications where ground noise is not an issue.
5
Based on the Type 2 circuit.
14
Loop-AM3440 Access DCS-MUX Multi-Services Cross Connect
sn = omit FXS Loop Feed = -48 Vdc with 25 mA current limit; alarm tone enable; normal ring
S1 FXS Loop Feed = -48 Vdc with 35 mA current limit
S4 Remove alarm tone
S5 Double ring tone transmit
Note: For sn (special function), please contact your nearest Loop sales representative.
For AM3440-A with ±48Vdc (SDA) power complied with IEEE1613 standard
PWRIE1613
For AM3440-C with ±48Vdc (SDB) power complied with IEEE1613 standard
For 12FXOA/12MAGA
Where typ is used to select the connector type:
For ODP
Where typ is used to select the connector type:
typ= Description Note
RJ 8 x RJ45
TELCO 1 x Telco 64 Connector
15
Loop-AM3440 Access DCS-MUX Multi-Services Cross Connect
For AM3440-A with ±48Vdc (SDA) power complied with IEEE1613 standard
PWRIE1613
For AM3440-C with ±48Vdc (SDB) power complied with IEEE1613 standard
24IE1613 For AM3440-A with ±24Vdc (SDA) power complied with IEEE1613 standard.
1*8
ST Separate
ZHHTT Z Multi-mode H 155 M H 820nm T 2km T
connector transceiver
& receiver
ST
QHATT Q Multi-mode H 155 M A 850nm T 2km T
connector
ST
NFB3T N Single mode F 125 M B 1310nm 3 30km T
connector
1*9
ST
QFBTT Q Multi-mode F 125 M B 1310nm T 2km T
connector
SC
NHC2S N Single mode H 155 M C 1550nm 2 20km S
connector
Single mode, 1310nm, Tx_min -13dBm, Rx_max -30dBm, SC type connector. Must use
T
Works with Toshiba teleprotection device 3*DS0
Single mode,1310nm, Tx_min -14dBm, Rx_max -36dBm, ST type connector Must use
S
Works with SEL teleprotection device 8*DS0
1*8
ST Separate
ZHHTT Z Multi-mode H 155 M H 820nm T 2km T
connector transceiver
& receiver
ST
QHATT Q Multi-mode H 155 M A 850nm T 2km T
connector
ST
NFB3T N Single mode F 125 M B 1310nm 3 30km T
connector
1*9
ST
QFBTT Q Multi-mode F 125 M B 1310nm T 2km T
connector
SC
NHC2S N Single mode H 155 M C 1550nm 2 20km S
connector
16
Loop-AM3440 Access DCS-MUX Multi-Services Cross Connect
For TDMoE/TDMoEA:
SFP Optical/Electrical Module Plug-in option, please go to SFP Optical Module Brochure for detail.
For VOIPGA
Where pt is used to select the power type:
pt= Description Note
For
PWR For AM3440-A with -48Vdc (SDA) power module AM3440-CHAK/CHB/C
For AM3440-B/C with -48Vdc (SDB) power module HC/CHCJ
17
Loop-AM3440 Access DCS-MUX Multi-Services Cross Connect
Ordering Examples
Example 1:
Loop-AM3440-CHAK, Loop-AM3440-CCB, Loop-AM3440-SDA, Loop-AM3440-4E1-RJ, Loop-AM3440-8RS232:
For AM3440-A type chassis with a CPU card (E1 external clock), a single -48 Vdc 150W power module,
4-channel E1 interface with RJ48C connectors, one 8RS232 plug-in module and fan tray.
Example 2:
Loop-AM3440-CHB, Loop-AM3440-CCB, Loop-AM3440-SDB, Loop-AM3440-M4E75, Loop-AM3440-8CD:
For AM3440-B type chassis with a CPU card (E1 external clock), a single -48 Vdc 100W power module, one
Mini Quad E1 interface with 75 ohm and one 8-channel G.703 interface at 64 Kbps data rate.
Example 3:
Loop-AM3440-CHCJ, Loop-AM3440-CCB, Loop-AM3440-SDB, Loop-AM3440-M4E120, Loop-AM3440-2GH:
For AM3440-C type chassis with a CPU card (E1 external clock), a single -48 Vdc 100W power module, one
Mini Quad E1 interface with 120 ohm and one 2-channel G.SHDSL plug-in module (2 pair).
* Future Option
18
Loop-AM3440 Access DCS-MUX Multi-Services Cross Connect
CCB Controller
Clock Source Internal, Line Interface, External (E1/T1/2048 KHz), Adaptive Clock Recovery for Pseudowires
(with TDMoEA module), SyncE
Alarm Relay Max. Current: 1A for 24VDC, 0.625A for 48VDC
Fuse alarm, performance alarm
Management
Console Electrical: RS232; Connector: HB15, female (with HB15-to-DB9 adaptor)
Micro USB
User Interface: Menu driven VT-100
Ethernet 1 Combo GE port, Connector: RJ45 & SFP
SNMPv1/v3, Telnet/SSH
Inband Management Inband 64 Kbps, support HDLC/PPP
System Configuration Parameters Active Configuration, Stored Configuration, and Default Configuration (Stored in
Non-volatile Memory)
Performance Monitor
Performance Registers Last 24 hours performance in 15 minute intervals and last 7 days in 24 hour summaries
Separate Registers Network, user, and remote site
Performance Reports Reports include E1 Bursty Errored Second, Severe Errored Second, Degraded Minutes. Also
available in Statistics (%)
Alarm Queue To record the latest alarm type, location, date and time
Threshold Bursty Seconds, Severely Errored Second, Degraded Minutes
Diagnostics
Loopback E1/T1 interface (Line Loopback, Payload Loopback, Local Loopback), DTE Loopback
(DTE-to-DTE, DTE to Line)
Test Pattern For Controller: 220-1, 215-1, 211-1, 29-1, and 4-byte user define pattern
Front Panel
Controller LED Indicators Power, ACTIVE, ALARM
A, B, C, D slots: Multi-Color LED indication
Physical /Electrical
Model AM3440-A AM3440-B AM3440-C
Dimensions 432.4 x 220 x 223.5 mm (WHD) 438 x 110 x 224 mm (WHD) 438 x 132 x 224 mm (WHD)
Power Single/ Dual -48 Vdc: -36 to -75 Vdc, Single/ Dual -48 Vdc: -36 to -75 Single/ Dual -48 Vdc: -36 to -75
100 Watts max. Vdc, 100 Watts max. Vdc, 100 Watts max.
Single/ Dual -48 Vdc: -36 to -75 Vdc, Single AC: 100 to 240 Vac, 50/60 Single AC: 100 to 240 Vac, 50/60
150 Watts max. Hz Hz
Single/ Dual -24 Vdc: -18 to -36 Vdc,
150 Watts max
Single/ Dual -125 Vdc: -40 to -150
Vdc, 100 Watts max
Temperature Operating Storage Operating Storage Operating Storage
-20 to 65°C -30 to 70°C -20 to 65°C -30 to 70°C -20 to 65°C -30 to 70°C
Weight Net Weight Max. Weight Net Weight Max. Weight Net Weight Max. Weight
6.0 Kg (13.23lbs) 16 Kg (35.28lbs) 4.0 Kg (8.82 8.0 Kg (17.64 5.0Kg (11.02lbs) 10.0 Kg
lbs) lbs) (22.05lbs)
Humidity 0-95%RH (non-condensing) 0-95%RH (non-condensing) 0-95%RH (non-condensing)
Mounting Desk-top stackable, 19” /23” rack Desk-top stackable, 19” /23” rack Desk-top stackable, 19” /23” rack
mountable mountable mountable
Line Power Available only with DC power for N/A N/A
Supply G.SHDSL card only
Power Max 110 Watts Max 45 Watts Max 57 Watts
Consumption
MTBF 421.91 years 852.80 years 213.68 years
19
Loop-AM3440 Access DCS-MUX Multi-Services Cross Connect
Certification
AM3440-A AM3440-B AM3440-C
EN55022 Class A, EN50024, EN300 EN55022 Class A, EN50024, EN300 386, EN55022 Class A, EN50024, EN300
386, FCC Part 15 Class A, FCC Part 68, FCC Part 15 Class A, FCC Part 68, 386, FCC Part 15 Class A, IEC60950-1,
CS-03, IEC60950, UL60950, IEC CS-03, IEC60950-1, EN60950-1 CS-03, EN60950-1, IEC 61850-3, IEEE
61850-3, IEEE 1613 1613
Compliance
ITU G.703, G.704, G.706, G.732, G.736, G.823, G.826, G.711, G.712, G.775, O.151, V.11, V.28, V.54
IETF SNMP v.3 (RFC2571~2575), ITU-T Rec.G.821, ITU-T Rec.G.827
Loop-VV Y-BOX
LINE
Connector BNC or RJ48C
Port Number For Y-BOX with BNC connectors: 4 line ports
For Y-BOX with RJ48C connectors: 16 line ports
Protection For Y-BOX with BNC connectors: support 2 Quad E1 plug-in card, 4 active E1, 4 standby E1
For Y-BOX with RJ48C connectors: support 8 Quad E1 plug-in cards, 16 active E1, 16 standby E1
For Y-BOX with RJ48C connectors: support 8 Quad T1 plug-in cards, 16 active T1, 16 standby T1
Mechanical
Height 44.5 mm/ 1.75 in
Width 432 mm/ 17 in
Depth 100 mm/ 3.9 in
20
Loop-AM3440 Access DCS-MUX Multi-Services Cross Connect
Router-A Interface
Number of ports 2 LAN ports, Max. 64 WAN ports, Each WAN port has data rate n x 64K bps, 1 n 32 ( 4Mbps
for total of all 64 WAN ports
Physical Interface 10/100 BaseT x 2
Connector RJ45
Routing protocol RIP-I, RIP-II, OSPF, Static
Supporting Protocols PPP (IPCP/BCP), MLPPP, HDLC, Frame Relay, and Cisco compatible HDLC, NAT/NAPT, DHCP
Diagnostic Ping, Trace route
QoS Rate limit
Router-B Interface
Number of ports 8 LAN ports, Max. 64 WAN ports. Each WAN port has data rate n x 64K bps, 1 n 32 ( 8Mbps
for total of all 64 WAN ports
Physical Interface 10/100 BaseT x 8
Connector RJ45
Routing protocol RIP-I, RIP-II, OSPF, Static
Supporting Protocols PPP (IPCP/BCP), MLPPP, HDLC, Frame Relay, and Cisco compatible HDLC, NAT/NAPT, DHCP
Diagnostic Ping, Trace route
QoS Rate limit, Policy based Diffserv/DSCP
VLAN Q-in-Q IEEE 802.1ad
21
Loop-AM3440 Access DCS-MUX Multi-Services Cross Connect
22
Loop-AM3440 Access DCS-MUX Multi-Services Cross Connect
23
Loop-AM3440 Access DCS-MUX Multi-Services Cross Connect
24
Loop-AM3440 Access DCS-MUX Multi-Services Cross Connect
Co-directional Interface
Interface ITU G.703 64 Kbps co-directional interface
Connector 120ohm, RJ48
Line Distance Up to 500 meters
Loopack DTE Payload Loopback, Local Loopback
25
Loop-AM3440 Access DCS-MUX Multi-Services Cross Connect
C37.94 Interface
820nm
Source LED Optical Line Rate 2.048Mbps
Wavelength 820nm Line Code NRZ
Connector ST Fiber Type Multi-mode
Optical Power -12dBm
850nm
Source VCSEL Optical Line Rate 2.048Mbps
Wavelength 850nm Line Code NRZ
Connector ST Duplex Plastic Connector Fiver Type Multi-mode
Optical Power -5.5dBm
1310nm
Source LED Optical Line Rate 2.048Mbps
Wavelength 1310nm Line Code NRZ
Connector ST Fiber Type Single & Multiple
Optical Power -14dBm
1550nm
Source LED Optical Line Rate 2.048Mbps
Wavelength 1550nm Line Code NRZ
Connector SC Fiber Type Single & Multiple
Optical Power -14dBm
26
Loop-AM3440 Access DCS-MUX Multi-Services Cross Connect
All in-band signaling tones are carried transparently by the digitizing process.
Customer is responsible for in-band signaling compatibility between a telephone and a switch, or between a PBX and a
switch.
QMAGA (old crank-handle hot-line telephones), MRD (Manual Ring Down) Voice Card
Connector RJ11 x 4
Power 110-220 Vac or ±48 Vdc
Alarm Conditioning CGA busy after 2.5 seconds of LOS, LOF
Encoding A-law or -law, user selectable together for all
Impedance Balanced 600 or 900 ohms (for magneto telephone impedance )
Longitudinal Conversion Loss > 46dB
Gain Adjustment -16 to +7 dB / 0.1dB step transmit gain (D-A)
-16 to +13 dB/0.1dB step receive gain (A-D)
Signal/ Distortion > 25dB with 1004 Hz, 0dBm input
Frequency Response ± 0.5 dB from 300 to 3400 Hz, coincide with ITU-T G.712
Idle Channel Noise Max. –65 dBm0p
Signaling
Minimum Detectable Ringing Voltage 16 Vrms
Crank Detectable Across L1 & L2 Mode (Tip and Ring), L1 & GND Mode(Tip and GND)
Crank Detected time Valid crank: more than 250 ms
Invalid crank: less than 160 ms
Ringing Generation Voltage: 76 Vrms (sine wave)
Frequency: 25Hz
Ring duration Software configurable options:
1. PLAR OFF
Continuous
Ring duration depends on cranking time
One Time
Crank the phone for one time, and the ring duration of the far-end phone
could be 0.7, 1.0, 1.5 or 2.0 sec
2. PLAR ON
when FXS phone off-hooked, the ring duration of the far-end magneto phone
could be 0.7, 1.0, 1.5 or 2.0 sec
Ringing Send Across L1 & L2 Mode (Tip and Ring), L1 & GND Mode(Tip and GND)
Signaling Turn Magneto Phone crank (Ringing across Tip and Ring or Tip and
Ground)
Signaling Bit A,B,C,D Programable
27
Loop-AM3440 Access DCS-MUX Multi-Services Cross Connect
12 MAGA (old crank-handle hot-line telephones), MRD (Manual Ring Down) Voice Card
Connector RJ11 x 12
Power 110-220 Vac or ±48 Vdc
Alarm Conditioning CGA busy after 2.5 seconds of LOS, LOF
Encoding A-law or -law, user selectable per card configurable
Impedance Balanced 600 or 900 ohms (for magneto telephone impedance )
Longitudinal Conversion Loss > 46dB
Gain Adjustment -21 to +7 dB / 0.1dB step transmit gain (D-A)
-21 to +13 dB/0.1dB step receive gain (A-D)
Signal/ Distortion > 25dB with 1004 Hz, 0dBm input
Frequency Response ± 0.5 dB from 300 to 3400 Hz, coincide with ITU-T G.712
Idle Channel Noise Max. –65 dBm0p
Signaling
Minimum Detectable Ringing Voltage 16 Vrms
Crank Detectable Across L1 & L2 Mode (Tip and Ring), L1 & GND Mode(Tip and GND) per port
software programmable
Crank Detected time Valid carnk: more than 250 ms
Invalid crank: less than 160 ms
Ringing Generation Voltage: 76 Vrms (sine wave)
Frequency: 25Hz
Ring duration Software configurable options:
1. PLAR OFF (Continuous Mode)
Ring duration depends on cranking time
3. PLAR ON
When FXS phone off-hooked, the ring duration of the far-end magneto
phone could be 0.7, 1.0, 1.5 or 2.0 sec
Ringing Send Across L1 & L2 Mode (Tip and Ring), L1 & GND Mode(Tip and GND)
Signaling Turn Magneto Phone crank (Ringing across Tip and Ring or Tip and Ground)
Signaling Bit A,B,C,D Programable
Signaling is carried transparently by the digitizing process.
Use Magneto card default setting for communications between magneto telephones
Use Magneto card PLAR mode setting for communications between a magneto telephone and a regular telephone
ABRA Card
Group Up to 8 groups per card, 16 members per group
Analog Bridge Mode Master/Slave Architecture
Downstream : 2 to many
Upstream : many to 2
Voice Conference Mode with Any-to-any conference bridge
CAS Signalling
Up to 16 members in one conference group
Silence detection/suppression
28
Loop-AM3440 Access DCS-MUX Multi-Services Cross Connect
M4TE Cards
The M4TE card supports DB37 to 4RJ48 connector, DB37 to 8BNC connector, and wire-wrap connector. E1/T1 per card
is software configurable.
Network Line Interface - T1
Line Rate 1.544 Mbps 32 ppm Framing D4/ESF
Line Code AMI/B8ZS Connector RJ48F, BNC, T1
Input Signal DSX-1 0dB to –30dB w/ALBO Output Signal DSX-1 w/0, -7.5, -15 dB LBO
Jitter AT&T TR 62411 Pulse Template AT&T TR 62411
Data Rate n * (64) Kbps (n=1 - 24) Surge Protection FCC Part 68 Sub Part D
29
Loop-AM3440 Access DCS-MUX Multi-Services Cross Connect
a switch.
-24Vdc power is for FXS PCB version C and up
30
Loop-AM3440 Access DCS-MUX Multi-Services Cross Connect
TDMoEA
Combo Gigabit Ethernet (GbE) Interface
Number of Ports 2
Speed 10/100/1000M bps
Connector RJ45 for twisted pair GbE, LC for optical GbE, auto detection
Gigabit Ethernet (GbE) Interface
Number of Port 2
Speed 10/100/1000 BaseT
Connector RJ45
Ethernet Function
Basic Features MDI/MDIX for 10/100/1000M BaseT auto-sensing
Ping function contained ARP
Packet Transparency Packet transparency support for all types of packet types including IEEE 802.1q VLAN and
802.1ad (Q-in-Q)
QoS User configurable 802.1p CoS, ToS in out-going IP frame
Traffic Control Ingress packet Rate limiting buckets per port for Ethernet port
Supporting Rate-based and Priority-based rate limiting for LAN port
Granularity:
a. From 64 Kbps to 1 Mbps in increments of 64 Kbps
b. From 1 Mbps to 100 Mbps in increments of 1 Mbps
c. From 100 Mbps to 1000 Mbps in increments of 10Mbps
Pause frame issued when the traffic exceeding the limited rate before packet dropped
following IEEE802.3X
Link Aggregation WAN supports Link Aggregation
Jitter & Wander
PPM: per G.823 Traffic
Standards Compliance
IEEE IETF
802.1d MAC Table Learning and STP RFC2236 IGMP Snooping v2*
802.1p Priority Code Point
802.1q VLAN RFC2495 E1/T1 OAM
802.1s MSTP*
802.1w RSTP
802.1ad Tag Stacking (Q-in-Q) RFC 4553 SAToP
802.3ad Link Aggregation RFC 5086 CESoPSN
ITU
MEF G.823/G.824 Traffic Interface
8 CESoETH
Certifications
EMC EN55022 Class A, EN50024, FCC Part 15 Subpart B Class A
Safety EN60950-1(CE)
* Future option
VOIPGA
Physical Interfaces
• W AN: 1 x 100BaseTx
• LAN: 2 x 100BaseTx
Voice Features
• G.711 a/μ, G.726(32K), G.729, G.723.1
• Silence Suppression and Detection
• Echo Cancellation (G.168)
• Adjustable jitter buffer
• Adjustable packet time (by Codec type)
• Programmable Gain Control Note
• Adjustable call progress tone volume Note
31
Loop-AM3440 Access DCS-MUX Multi-Services Cross Connect
Telephony Specifications
• In-Band DTMF, Out-of-Band DTMF Relay
(RFC2833 or SIP INFO)
• Caller ID Note
• T.30 FAX passthrough, T.38 Real Time FAX Relay Note
32
Loop-AM3440 Access DCS-MUX Multi-Services Cross Connect
Application Illustrations
E1/T1 LAN
33
Loop-AM3440 Access DCS-MUX Multi-Services Cross Connect
E 1/ T 1 E 1/ T 1 E 1/ T 1
NETWORK
SNMP
Mana ger
E1/T1
LAN
34
Loop-AM3440 Access DCS-MUX Multi-Services Cross Connect
E 1/ T 1 E 1/ T 1 E 1/ T 1
NETWORK
SNMP
Mana ger
E1/T1
LAN
12 - channel Magneto
1 - channel C37. 94
4 - channel C37 . 94
8 - channel RS232 with X.50 subrate
6 - channel V.110
Note : Only CHCJ Unit applicable to
8 - LAN- port / 64- WAN - port Router -B DS0 SNCP function
VOIPGA (D) = Discontinued
Conference card (D)
TDMoE (D) / TDMoEA
8- Data Bridge
1FOMA
8UDTEA
6UDTEA
35
Loop-AM3440 Access DCS-MUX Multi-Services Cross Connect
Note: ULSR ring does not suport E1 unframed mode. Users must use E1 framed mode to set up a ULSR ring.
36
Loop-AM3440 Access DCS-MUX Multi-Services Cross Connect
AM3440-C
AM3440-A AM3440-A
AM3440-A
E1/T1
Radios AM3440-B
37