Professional Documents
Culture Documents
Client: GNPower Kauswagan LTD. CO. Temp.: 548.9°C Hot recording(1): 20.05.2023 - 20.05.2023 Performed by: bin Idros, Idzaid; bin Norazhar, Ahmad Haziq; bin Yusof, Mohd Hafitz; Mbonani, Thokoza
Plant: Kauswagan GNPower Coal Plant Temp.: Ambient°C Cold recording(1): 24.04.2023 - 05.05.2023 Performed by: bin Idros, Idzaid; bin Yusof, Mohd Hafitz; Van Den Berg, Rudolph Johannes; Voth, Peter
Area Unit 30 - LBB
System: 30LBB01BR001
ZN22C-
4 30LBB01BR001-BQ003 C80X150- 80 75 88 -13 88 62 Yes 94 94 56 Yes -6 0 - 150 150 X
b
ZN22C-
5 30LBB01BR001-BQ004 C80X150- 20170176 80 75 86 -11 86 64 Yes 90 90 60 Yes -4 0 - 150 150
b
TD30B13-
6 30LBB01BR001-BQ005
M30
7932005-C1-????? 10 3 18 35 -17 35 5 Yes 21 39 -18 39 1 Yes -3 -4 0 - 40 40 X
Type 49
7 30LBB01BR001-BQ006 G2P by 80 0 0 75
others
TD30B15- 7932005-C1-02005
8 30LBB01BR001-BQ007
M36 -140?
16,081 1 18 34 -16 34 6 Yes 19 42 -23 42 -2 Yes -1 -8 0 - 40 40 X
ZN21C-
9 30LBB01BR001-BQ008 C80X150- 20170170 80 76 74 74 76 Yes 150 150 Yes -76 -76 0 - 150 150 X
b
PHE25-
10 30LBB01BR001-BQ009_E 80/12127S 7932005-C1-02006 12,127 Yes Yes 0 - 100 100 X
-M30
PHE25-
11 30LBB01BR001-BQ009_W 80/12127S 7932005-C1-02006 12,127 Yes Yes 0 - 100 100 X
-M30
PE18-
12 30LBB01BR001-BQ010_E 120/3249S 7932005-CI-02007 3,249 120 120 0 - 150 150 X
-M24
PE18-
13 30LBB01BR001-BQ010_W 120/3249S 7932005-CI-02007 3,249 120 120 0 - 150 150 X
-M24
10.11.2023 62/90
Recording list for pipe supports
Client: GNPower Kauswagan LTD. CO. Temp.: 548.9°C Hot recording(1): 20.05.2023 - 20.05.2023 Performed by: bin Idros, Idzaid; bin Norazhar, Ahmad Haziq; bin Yusof, Mohd Hafitz; Mbonani, Thokoza
Plant: Kauswagan GNPower Coal Plant Temp.: Ambient°C Cold recording(1): 24.04.2023 - 05.05.2023 Performed by: bin Idros, Idzaid; bin Yusof, Mohd Hafitz; Van Den Berg, Rudolph Johannes; Voth, Peter
Area Unit 30 - LBB
System: 30LBB01BR001
ZN22C- Name plate missing: - Status: open No NP;E-Dim: 3788mm; Photo: IMG_1823-IMG_2581
4 30LBB01BR001-BQ003 C80X150-
b
ZN22C- Corroded pipe connecting point; E-Dim: 3783mm; Photo: IMG_1812-IMG_2579
5 30LBB01BR001-BQ004 C80X150- 20170176
b
Sticker red missing: - Status: open; Travel scale: Painted travel scale - Status: open; Clash: Thread rod clash with scaffolding - Status: Technical documentation of the spring hanger not available. No statement can be made
open about the nominal values. A spring rate cannot be determined either. However, in order to be
TD30B13- able to adjust the load capacity, the spring rate is obligatory. If changes are made to the
6 30LBB01BR001-BQ005 7932005-C1-????? piping or the weight distribution, new load capacities cannot be determined and
M30
adjusted.Painted TS; No hot sticker; Thread rod clash with scaffolding; E-Dim: 3866mm;
Photo: IMG_1841-IMG_1851
Type 49 Photo: IMG_1805-IMG_1811
7 30LBB01BR001-BQ006 G2P by
others
Sticker red missing: - Status: open; Corrosion slight: Corroded thread rod - Status: open; Travel scale: Painted travel scale - Status: Technical documentation of the spring hanger not available. No statement can be made
open; Name plate: Painted nameplate - Status: open about the nominal values. A spring rate cannot be determined either. However, in order to be
TD30B15- 7932005-C1-02005 able to adjust the load capacity, the spring rate is obligatory. If changes are made to the
8 30LBB01BR001-BQ007 piping or the weight distribution, new load capacities cannot be determined and
M36 -140?
adjusted.Painted NP; Painted TS; No hot sticker; Corroded thread rod; E-Dim: 1252mm;
Photo: IMG_1793-IMG_1804
ZN21C- Counter nut loose: - Status: open LNLE-Dim: 1373mm; Photo: IMG_1782-IMG_2559
9 30LBB01BR001-BQ008 C80X150- 20170170
b
PHE25- Load scale missing: - Status: open; Travel scale: Painted travel scale - Status: open; Corrosion slight: Thread rod corroded - Status: No LS; Painted NP; Painted TS; Thread rod corroded; Corroded bracket; E-Dim: 2124mm;
10 30LBB01BR001-BQ009_E 80/12127S 7932005-C1-02006 open Photo: IMG_1772-IMG_2561
-M30
PHE25- Travel scale: Painted travel scale - Status: open; Corrosion slight: Corroded threaded rod - Status: open; Lower End Position: - No LS; Painted NP; Painted TS; BO; Corroded pipe support; Corroded thread rod; E-Dim:
11 30LBB01BR001-BQ009_W 80/12127S 7932005-C1-02006 Status: open; Load scale missing: - Status: open; Name plate: Painted nameplate - Status: open 2128mm; Photo: IMG_1763-IMG_2561
-M30
PE18- Travel scale: Painted travel scale - Status: open; Name plate: Painted nameplate - Status: open; Load scale missing: - Status: open; No LS; Painted NP; Painted TS; BO; Corroded thread rod & turnbuckle; E-Dim: 2182mm;
12 30LBB01BR001-BQ010_E 120/3249S 7932005-CI-02007 Lower End Position: - Status: open; Corrosion slight: Corroded thread rod & turnbuckle - Status: open Photo: IMG_1743-IMG_2563
-M24
PE18- Corrosion slight: Corroded thread rod & turnbuckle - Status: open; Travel scale: Painted travel scale - Status: open; Name plate: No LS; Painted NP; Painted TS; BO; Corroded thread rod & turnbuckle; E-Dim: 2167mm;
13 30LBB01BR001-BQ010_W 120/3249S 7932005-CI-02007 Painted nameplate - Status: open; Load scale missing: - Status: open; Lower End Position: - Status: open Photo: IMG_1751-IMG_2563
-M24
10.11.2023 63/90
Recording list for pipe supports
Client: GNPower Kauswagan LTD. CO. Temp.: 548.9°C Hot recording(1): 20.05.2023 - 20.05.2023 Performed by: bin Idros, Idzaid; bin Norazhar, Ahmad Haziq; bin Yusof, Mohd Hafitz; Mbonani, Thokoza
Plant: Kauswagan GNPower Coal Plant Temp.: Ambient°C Cold recording(1): 24.04.2023 - 05.05.2023 Performed by: bin Idros, Idzaid; bin Yusof, Mohd Hafitz; Van Den Berg, Rudolph Johannes; Voth, Peter
Area Unit 30 - LBB
System: 30LBB02BR001
ZN22C-
4 44919 30LBB02BR001-BQ003 C80X150- 20170174 80 0 75 70 5 70 80 Yes 72 72 78 Yes -2 0 - 150 150 X
b
ZN22C-
5 44919 30LBB02BR001-BQ004 C80X150- 20170175 80 0 75 77 -2 77 73 Yes 77 77 73 Yes 0 0 - 150 150 X
b
TD30B14-
6 44919 30LBB02BR001-BQ005
M30
14,873 4 24 28 -4 0 - 40 40 X
Type 49
7 44919 30LBB02BR001-BQ006 G2P by X
others
TD30B16-
8 44919 30LBB02BR001-BQ007
M36
20,214 10 28 38 -10 38 2 No 38 45 -7 45 -5 Yes -10 -7 0 - 40 40 X
PE29-
9 44919 30LBB02BR001-BQ008 E 130/12124 12,124 130 -130 0 - 150 150 X
S-M30
PE29-
10 44919 30LBB02BR001-BQ008 W 130/12124 12,124 130 -130 0 - 150 150 X
S-M30
PE26-
11 30LBB02BR001-BQ009 E 160/7174S 7,174 160 -160 0 - 180 180 X
-M24
PE26-
12 30LBB02BR001-BQ009 W 160/7174S 7,174 160 -160 0 - 180 180 X
-M24
10.11.2023 64/90
Recording list for pipe supports
Client: GNPower Kauswagan LTD. CO. Temp.: 548.9°C Hot recording(1): 20.05.2023 - 20.05.2023 Performed by: bin Idros, Idzaid; bin Norazhar, Ahmad Haziq; bin Yusof, Mohd Hafitz; Mbonani, Thokoza
Plant: Kauswagan GNPower Coal Plant Temp.: Ambient°C Cold recording(1): 24.04.2023 - 05.05.2023 Performed by: bin Idros, Idzaid; bin Yusof, Mohd Hafitz; Van Den Berg, Rudolph Johannes; Voth, Peter
Area Unit 30 - LBB
System: 30LBB02BR001
ZN22C- Oil level: Low snubber oil - Status: open SO; Corroded weld-on clevices; E-Dim: 3752mm; Photo: IMG_1663-IMG_2572
4 44919 30LBB02BR001-BQ003 C80X150- 20170174
b
ZN22C- Oil level: Low snubber oil - Status: open Low snubber oil; E-Dim: 3758mm; Photo: IMG_1698-IMG_2570
5 44919 30LBB02BR001-BQ004 C80X150- 20170175
b
Travel scale: Painted travel scale - Status: open; Corrosion slight: Corrosion on threaded rod - Status: open; Name plate: Painted Technical documentation of the spring hanger not available. No statement can be made
nameplate - Status: open about the nominal values. A spring rate cannot be determined either. However, in order to be
TD30B14- able to adjust the load capacity, the spring rate is obligatory. If changes are made to the
6 44919 30LBB02BR001-BQ005 piping or the weight distribution, new load capacities cannot be determined and
M30
adjusted.Painted NP; Painted TS;Corroded spring; Corroded thread rod; E-Dim: 3829mm;
Photo: IMG_1647-IMG_1654
Type 49 Clash: Clash with grating - Status: open Clash with grating; Photo: IMG_1673-IMG_1680
7 44919 30LBB02BR001-BQ006 G2P by
others
Corrosion slight: Corroded spring & thread rod - Status: open; Travel scale: Painted travel scale - Status: open; Sticker red missing: - Technical documentation of the spring hanger not available. No statement can be made
Status: open; Name plate: Painted nameplate - Status: open about the nominal values. A spring rate cannot be determined either. However, in order to be
TD30B16- able to adjust the load capacity, the spring rate is obligatory. If changes are made to the
8 44919 30LBB02BR001-BQ007 piping or the weight distribution, new load capacities cannot be determined and
M36
adjusted.Painted NP, Painted TS; No hot sticker; Corroded spring & thread rod; E-Dim:
1165mm; Photo: IMG_1681-IMG_1691
Corrosion slight: Corroded thread rod - Status: open; Miscellaneous: Sheared off travel indicator pin - Status: open; Travel scale: Nothing is known about the design and the upper and lower limits of these constant hangers
PE29- Painted travel scale - Status: open; Name plate: Painted nameplate - Status: open; Lower End Position: - Status: open and supports. The adjustment scale is not meaningful because the scale only ranges from 0
9 44919 30LBB02BR001-BQ008 E 130/12124 to 60 and no unit is given. Sheared off travel indicator pin; Painted NP; Painted TS; BO;
S-M30 Corroded thread rod; E-Dim: 2065mm; Photo: IMG_1714-IMG_2568
Travel scale: Painted travel scale - Status: open; Miscellaneous: Sheared off travel indicator pin - Status: open; Corrosion slight: Due to a lack of technical information, nothing is known about the design and the upper and
Corroded thread rod - Status: open; Name plate: Painted nameplate - Status: open lower limits of these constant hangers and supports. The adjustment scale is not meaningful
PE29- because the scale only ranges from 0 to 60 and no unit is given. But this does not allow any
10 44919 30LBB02BR001-BQ008 W 130/12124 conclusion to be drawn about the actual travel positions.Sheared off travel indicator pin;
S-M30 Painted NP; Painted TS Corroded thread rod; BO; E-Dim: 2066mm; Photo: IMG_1707-
IMG_2568
Travel scale: Painted travel scale - Status: open; Name plate: Painted nameplate - Status: open; Corrosion slight: Corroded thread rod Due to a lack of technical information, nothing is known about the design and the upper and
PE26- - Status: open; Counter nut loose: - Status: open lower limits of these constant hangers and supports. The adjustment scale is not meaningful
11 30LBB02BR001-BQ009 E 160/7174S because the scale only ranges from 0 to 60 and no unit is given. But this does not allow any
-M24 conclusion to be drawn about the actual travel positions.Painted NP; Painted TS; Loose LNl;
Corroded thread rod; E-Dim: 2173mm; Photo: IMG_1731-IMG_2565
Corrosion slight: Corroded thread rod - Status: open; Travel scale: Painted travel scale - Status: open; Name plate: Painted nameplate Due to a lack of technical information, nothing is known about the design and the upper and
PE26- - Status: open lower limits of these constant hangers and supports. The adjustment scale is not meaningful
12 30LBB02BR001-BQ009 W 160/7174S because the scale only ranges from 0 to 60 and no unit is given. But this does not allow any
-M24 conclusion to be drawn about the actual travel positions.Painted NP; Painted TS; Corroded
thread rod; E-Dim: 2139mm; Photo: IMG_1722-IMG_2565
10.11.2023 65/90
Recording list for pipe supports
Client: GNPower Kauswagan LTD. CO. Temp.: 548.9°C Hot recording(1): 20.05.2023 - 20.05.2023 Performed by: bin Idros, Idzaid; bin Norazhar, Ahmad Haziq; bin Yusof, Mohd Hafitz; Mbonani, Thokoza
Plant: Kauswagan GNPower Coal Plant Temp.: Ambient°C Cold recording(1): 24.04.2023 - 05.05.2023 Performed by: bin Idros, Idzaid; bin Yusof, Mohd Hafitz; Van Den Berg, Rudolph Johannes; Voth, Peter
Area Unit 30 - LBB
System: 30LBB10BR001
70055105
171206 -
30LBB10BR001-SNB-001 0
2 41900
W (YZNA125
SNUBBER XY 200 52 235 126 109 126 274 Yes 287 143 144 143 257 Yes -52 -17 0 - 400 400 X
Direction
X400 sp)
70055105
171207 -
30LBB10BR001-SNB-001 0
3 41900
S (YZNA125
SNUBBER XY 200 52 235 155 80 155 245 Yes 287 118 169 118 282 Yes -52 37 0 - 400 400 X
Direction
X400 sp)
30LBB10BR001-SPG-002 6C4D1020
4 39300
N 9
J-0903-07 31,285 74 74 0 - 102 102 X
30LBB10BR001-SPG-002 6C4D1020
5 39300
S 9
J-0903-07 31,285 74 74 0 - 102 102 X
6 35100 30LBB10BR001-LMT-003 45.... Z Direction Limit X
30LBB10BR001-SPG-004 51131307
7 32445
E 0
J-0903-09 18,663 44 70 26 44 0 - 90 90 X
30LBB10BR001-SPG-004 51131307
8 32445
W 0
J-0903-09 18,663 44 60 16 44 0 - 90 90 X
30LBB10BR001-SPG-005 6C521780
9 32272
S 7
31804017 22,71 143 143 0 - 178 178 X
30LBB10BR001-SPG-005 6C521780
10 32272
N 7
31804018 22,71 143 143 0 - 178 178 X
30LBB10BR001-SPG-006 6C522790
11 32135
N 6
31804019 14,538 230 230 0 - 279 279 X
30LBB10BR001-SPG-006 6C522790
12 32135
S 6
not readable 14,538 230 230 0 - 279 279 X
70034103
5 (YZNA SNUBBER X
13 30000 30LBB10BR001-SNB-007
80x300- Direction
80 135 218 216 2 216 84 Yes 83 129 -46 129 171 Yes 135 87 0 - 300 300 X
W)
171209 -
70043104
14 27500 30LBB10BR001-SNB-008
0
SNUBBER Y 120 118 91 67 24 67 233 Yes 209 51 158 51 249 No -118 16 0 - 300 300 X
Direction
30LBB10BR001-SPG-009 6R562411
15 26150
N 1
31804021 23,704 194 194 0 - 241 241 X
30LBB10BR001-SPG-009 6R562411
16 26150
S 1
31804022 23,704 194 194 0 - 241 241 X
6E5D2161
17 21978 30LBB10BR001-SPG-010
2
1180xxxx 38,355 176 176 0 - 216 216 X
70034103
171210 -
5 (YZNA
18 19500 30LBB10BR001-SNB-010A
80x300-
SNUBBER X 80 76 188 230 -42 230 70 No 264 233 31 233 67 Yes -76 -3 0 - 300 300 X
Direction
W)
10.11.2023 66/90
Recording list for pipe supports
Client: GNPower Kauswagan LTD. CO. Temp.: 548.9°C Hot recording(1): 20.05.2023 - 20.05.2023 Performed by: bin Idros, Idzaid; bin Norazhar, Ahmad Haziq; bin Yusof, Mohd Hafitz; Mbonani, Thokoza
Plant: Kauswagan GNPower Coal Plant Temp.: Ambient°C Cold recording(1): 24.04.2023 - 05.05.2023 Performed by: bin Idros, Idzaid; bin Yusof, Mohd Hafitz; Van Den Berg, Rudolph Johannes; Voth, Peter
Area Unit 30 - LBB
System: 30LBB10BR001
10.11.2023 67/90
Recording list for pipe supports
Client: GNPower Kauswagan LTD. CO. Temp.: 548.9°C Hot recording(1): 20.05.2023 - 20.05.2023 Performed by: bin Idros, Idzaid; bin Norazhar, Ahmad Haziq; bin Yusof, Mohd Hafitz; Mbonani, Thokoza
Plant: Kauswagan GNPower Coal Plant Temp.: Ambient°C Cold recording(1): 24.04.2023 - 05.05.2023 Performed by: bin Idros, Idzaid; bin Yusof, Mohd Hafitz; Van Den Berg, Rudolph Johannes; Voth, Peter
Area Unit 30 - LBB
System: 30LBB10BR001
30LBB10BR001-SPG-004 51131307 Lower End Position: Bottomed out - Status: open; Travel scale: Damaged travel scale - Status: open; Corrosion slight: Corroded BO; Damaged NP; Damaged TS; Corroded thread rod; E-Dim: 3185mm; Photo No.:
7 32445 J-0903-09 threaded rod - Status: open; Name plate damaged: - Status: open IMG_1949-IMG_1960
E 0
30LBB10BR001-SPG-004 51131307 Travel scale damaged: - Status: open; Name plate damaged: - Status: open; Lower End Position: - Status: open; Corrosion slight: BO; Damaged NP; Damaged TS; Corroded thread rod; E-Dim: 3227mm; Photo No.:
8 32445 J-0903-09 Corrosion at threaded rod - Status: open IMG_1937-IMG_1947
W 0
Travel scale damaged: - Status: open; Load scale missing: - Status: open; Name plate damaged: - Status: open; Travel scale: Technical informations, nominal values of the supports are not available, travel scale is not
30LBB10BR001-SPG-005 6C521780 Unknown travel scale - Status: open meaningful and load scale is not available. No statements can be made regarding position,
9 32272 31804017 travel or setting load. No LS, Damaged NP & TS; Unknown TS; E-Dim: 2554mm; Photo No.:
S 7
DSCN2220-DSCN2238
Travel scale: Unknown travel scale - Status: open; Load scale missing: - Status: open Technical informations, nominal values of the supports are not available, travel scale is not
30LBB10BR001-SPG-005 6C521780 meaningful and load scale is not available. No statements can be made regarding position,
10 32272 31804018 travel or setting load. No LS, Unknown TS; E-Dim: 3107mm; Photo No.: DSCN2177-
N 7
DSCN2193
Load scale missing: - Status: open; Travel scale: Unknown travel scale - Status: open Technical informations, nominal values of the supports are not available, travel scale is not
30LBB10BR001-SPG-006 6C522790 meaningful and load scale is not available. No statements can be made regarding position,
11 32135 31804019 travel or setting load.Unknown TS, No LSE-Dim: 2950mm; Photo No.: DSCN2194-
N 6
DSCN2203
Load scale missing: - Status: open; Counter nut loose: - Status: open Technical informations, nominal values of the supports are not available, travel scale is not
30LBB10BR001-SPG-006 6C522790 meaningful and load scale is not available. No statements can be made regarding position,
12 32135 not readable travel or setting load.Unknown TS; No LS, Loose LN; E-Dim: 3014mm; Photo No.:
S 6
DSCN2204-DSCN2218
70034103 Oil level: No oil sight glass - Status: open; Deflection > 6°: 7.8' - Status: open Corroded safety pin & clevies; No oil sight glass; Snubber angulation: -7.8; E-Dim: 1488mm;
5 (YZNA SNUBBER X Photo No.: DSCN2268-DSCN2282
13 30000 30LBB10BR001-SNB-007
80x300- Direction
W)
171209 - Oil level: No oil sight glass - Status: open; Deflection > 6°: 9.4' - Status: open No oil sight glass, Snubber angulation: -9.4; E-Dim: 1119mm; Photo No.: IMG_1979-
70043104 IMG_2734
14 27500 30LBB10BR001-SNB-008 SNUBBER Y
0
Direction
Load scale missing: - Status: open; Travel scale: Unknown travel scale - Status: open; Counter nut loose: - Status: open; Clash: T - Technical informations, nominal values of the supports are not available, travel scale is not
30LBB10BR001-SPG-009 6R562411 Status: open meaningful and load scale is not available. No statements can be made regarding position,
15 26150 31804021 travel or setting load.Unknown TS, No LS, Loose LN; Turnbuckle clash with cable tray;E-
N 1
Dim: 2680mmm; Photo No.: IMG_1990-IMG_2721
10.11.2023 68/90
Recording list for pipe supports
Client: GNPower Kauswagan LTD. CO. Temp.: 548.9°C Hot recording(1): 20.05.2023 - 20.05.2023 Performed by: bin Idros, Idzaid; bin Norazhar, Ahmad Haziq; bin Yusof, Mohd Hafitz; Mbonani, Thokoza
Plant: Kauswagan GNPower Coal Plant Temp.: Ambient°C Cold recording(1): 24.04.2023 - 05.05.2023 Performed by: bin Idros, Idzaid; bin Yusof, Mohd Hafitz; Van Den Berg, Rudolph Johannes; Voth, Peter
Area Unit 30 - LBB
System: 30LBB10BR001
10.11.2023 69/90
Recording list for pipe supports
Client: GNPower Kauswagan LTD. CO. Temp.: 548.9°C Hot recording(1): 20.05.2023 - 20.05.2023 Performed by: bin Idros, Idzaid; bin Norazhar, Ahmad Haziq; bin Yusof, Mohd Hafitz; Mbonani, Thokoza
Plant: Kauswagan GNPower Coal Plant Temp.: Ambient°C Cold recording(1): 24.04.2023 - 05.05.2023 Performed by: bin Idros, Idzaid; bin Yusof, Mohd Hafitz; Van Den Berg, Rudolph Johannes; Voth, Peter
Area Unit 30 - LBB
System: 30LBB10BR001
10.11.2023 70/90
Recording list for pipe supports
Client: GNPower Kauswagan LTD. CO. Temp.: 548.9°C Hot recording(1): 20.05.2023 - 20.05.2023 Performed by: bin Idros, Idzaid; bin Norazhar, Ahmad Haziq; bin Yusof, Mohd Hafitz; Mbonani, Thokoza
Plant: Kauswagan GNPower Coal Plant Temp.: Ambient°C Cold recording(1): 24.04.2023 - 05.05.2023 Performed by: bin Idros, Idzaid; bin Yusof, Mohd Hafitz; Van Den Berg, Rudolph Johannes; Voth, Peter
Area Unit 30 - LBB
System: 30LBB10BR011
70031103
5 (YZNA 171218 X direction
2 2300 30LBB10BR011-SNB-027
80x150- Snubber
80 8 82 82 68 Yes 73 73 77 Yes -8 9 0 - 150 150 X
W)
CONN. TO
3 8620
MAB10HA001/LBB10/01
10.11.2023 71/90
Recording list for pipe supports
Client: GNPower Kauswagan LTD. CO. Temp.: 548.9°C Hot recording(1): 20.05.2023 - 20.05.2023 Performed by: bin Idros, Idzaid; bin Norazhar, Ahmad Haziq; bin Yusof, Mohd Hafitz; Mbonani, Thokoza
Plant: Kauswagan GNPower Coal Plant Temp.: Ambient°C Cold recording(1): 24.04.2023 - 05.05.2023 Performed by: bin Idros, Idzaid; bin Yusof, Mohd Hafitz; Van Den Berg, Rudolph Johannes; Voth, Peter
Area Unit 30 - LBB
System: 30LBB10BR011
10.11.2023 72/90
Recording list for pipe supports
Client: GNPower Kauswagan LTD. CO. Temp.: 548.9°C Hot recording(1): 20.05.2023 - 20.05.2023 Performed by: bin Idros, Idzaid; bin Norazhar, Ahmad Haziq; bin Yusof, Mohd Hafitz; Mbonani, Thokoza
Plant: Kauswagan GNPower Coal Plant Temp.: Ambient°C Cold recording(1): 24.04.2023 - 05.05.2023 Performed by: bin Idros, Idzaid; bin Yusof, Mohd Hafitz; Van Den Berg, Rudolph Johannes; Voth, Peter
Area Unit 30 - LBB
System: 30LBB10BR012
70031103
5 (YZNA 171219 - (X
2 2300 30LBB10BR012-SNB-028
80x150- direction Snubber)
80 6 78 48 30 48 102 Yes 84 46 38 46 104 Yes -6 2 0 - 150 150 X
W)
CONN. TO
3 8620
10MAB10HA001/LBB10/02
10.11.2023 73/90
Recording list for pipe supports
Client: GNPower Kauswagan LTD. CO. Temp.: 548.9°C Hot recording(1): 20.05.2023 - 20.05.2023 Performed by: bin Idros, Idzaid; bin Norazhar, Ahmad Haziq; bin Yusof, Mohd Hafitz; Mbonani, Thokoza
Plant: Kauswagan GNPower Coal Plant Temp.: Ambient°C Cold recording(1): 24.04.2023 - 05.05.2023 Performed by: bin Idros, Idzaid; bin Yusof, Mohd Hafitz; Van Den Berg, Rudolph Johannes; Voth, Peter
Area Unit 30 - LBB
System: 30LBB10BR012
10.11.2023 74/90
Recording list for pipe supports
Client: GNPower Kauswagan LTD. CO. Temp.: 548.9°C Hot recording(1): 20.05.2023 - 20.05.2023 Performed by: bin Idros, Idzaid; bin Norazhar, Ahmad Haziq; bin Yusof, Mohd Hafitz; Mbonani, Thokoza
Plant: Kauswagan GNPower Coal Plant Temp.: Ambient°C Cold recording(1): 24.04.2023 - 05.05.2023 Performed by: bin Idros, Idzaid; bin Yusof, Mohd Hafitz; Van Den Berg, Rudolph Johannes; Voth, Peter
Area Unit 30 - LBB
System: 30LBB10BR013
56131500
2 30LBB10BR013-SPG-020
0
35,37 48 20 22 -2 22 68 Yes 68 61 7 61 29 Yes -48 -39 0 - 90 90 X
3 30LBB10BR013-LMT-021 45.... Y Direction Limiter
168215 -
4 30LBB10BR013-SPG-023 MADE in 31804010 79,391 47 75 75 1 No 104 104 -28 Yes -47 -29 0 - 76 76 X
China
70051105
30LBB10BR013-SNB-024 0 171215 - Z
7 2800
N (YZNA125 Direction Snubber
200 37 57 32 25 32 118 Yes 94 55 39 55 95 Yes -37 -23 0 - 150 150 X
x150)
70051105
30LBB10BR013-SNB-024 0 171216 - (Z
8 2800
S (YZNA125 Direction Snubber)
200 37 57 43 14 43 107 Yes 94 61 33 61 89 Yes -37 -18 0 - 150 150 X
x150)
70041104
0 171217 - (Y
9 3500 30LBB10BR013-SNB-025
(YZNA100 Direction Snubber)
120 38 94 132 61 71 61 59 Yes -38 0 - 120 120 X
x150 sp)
10.11.2023 75/90
Recording list for pipe supports
Client: GNPower Kauswagan LTD. CO. Temp.: 548.9°C Hot recording(1): 20.05.2023 - 20.05.2023 Performed by: bin Idros, Idzaid; bin Norazhar, Ahmad Haziq; bin Yusof, Mohd Hafitz; Mbonani, Thokoza
Plant: Kauswagan GNPower Coal Plant Temp.: Ambient°C Cold recording(1): 24.04.2023 - 05.05.2023 Performed by: bin Idros, Idzaid; bin Yusof, Mohd Hafitz; Van Den Berg, Rudolph Johannes; Voth, Peter
Area Unit 30 - LBB
System: 30LBB10BR013
168215 - Travel scale: Twisted red sticker - Status: open; Miscellaneous: Support inside insulation - Status: open; Miscellaneous: Travel Support inside insulation, Travel indicator pin clash with clading; Hot/cold sticker unclear
4 30LBB10BR013-SPG-023 MADE in 31804010 indicator pin clash with insulation - Status: open indication; E-dim: 621mm; Photo No.: IMG_2174-IMG_2179
China
70051105 Oil level: No oil sight glass - Status: open No oil sight glassDimension: 1951 mm Photo No.: IMG_2221-IMG_2232
30LBB10BR013-SNB-024 0 171215 - Z
7 2800
N (YZNA125 Direction Snubber
x150)
70051105 Oil level: No oil sight glass - Status: open Pipe clashes with other pipe, no oil sight glassE-dim: 1951mm; Photo No.: IMG_2197-
30LBB10BR013-SNB-024 0 171216 - (Z IMG_2208
8 2800
S (YZNA125 Direction Snubber)
x150)
70041104 Oil level: No oil sight glass - Status: open No oil sight glassE-dim: 764mm; Photo No.: IMG_2210-IMG_2220
0 171217 - (Y
9 3500 30LBB10BR013-SNB-025
(YZNA100 Direction Snubber)
x150 sp)
Photo No.: IMG_2233-IMG_2239
10 5000 30LBB10BR013-LMT-029 Type 49 X Direction Limiter
Miscellaneous: Support inside insulation - Status: open Support inside insulation, SR unknown; E-dim: 1072mm;Photo No.: IMG_2242-IMG_2249
11 7370 30LBB10BR013-SPG-026 561115000 J0903-32
10.11.2023 76/90