RF Cables for Telecom Systems
RF Cables for Telecom Systems
I L
DJ
r-
0
�
r-
"'
0
"'
n
DJ
c-
L
"'
(D
8
la dA
Your Telecom Partner
Accessories
lowlo.Caai�
,-·•nd
S,r,t;1 (JfOVISU &l<dlfK.lll:IMI
a,n,lltf CIIOAI
RF Cable (Corrugated Copper tube)
ambdA
�
LLA 50-(1/2")
Your Telecom Partner
Mechanical Properties
Diameter Over Dielectric(mm) 12.3
Electrical Properties
Capacitance (PF/m) 76
800~1000 1.07
VSWR(±3%)
1700~2300 1.07
lambdA
LLT-50(7/8")
Your Telecom Partner
Mechanical Properties
Diameter Over Dielectric(mm) 22.2
Electrical Properties
Charateristic impedance (0) 50±1
Capacitance (PF/m) 76
800-1000 1.06
VSWR(±3%)
1700-2300 1.06
lambdA
Your Telecom Partner
LLH-50(1-1/4”)
Mechanical Properties
Diameter Over Dielectric(mm) 32.7
Electrical Properties
Charateristic impedance (Ω) 50±1
Mechanical Properties
Diameter Over Dielectric(mm) 42.3
Electrical Properties
Charateristic impedance (0) 50±1
LSRY-50(1 /4")
lambdA
Your Telecom Partner
Mechanical Properties
Diameter Over Dielectric(mm) 9
Diameter Over Jacket(mm) 13.3
Inner Conductor OD(mm) 3.6
Outer Conductor OD(mm) 12.1
Weight (kg/m) 0.2
Min bending radius single bending (mm) 17
Min bending radius repeated bending (mm) 55
Tensile strength(N) 800
Operating temperature (deg Celcius) -4o·c ~+ 7o•c
Electrical Properties
Charateristic impedance (0) 50±1
Relative propagation velocity (%) 82
Capacitance (PF/m) 81
Minimum insulation resistance(DC 500V 1 minute) 3000MO•km
Peak power rating (kW) 20
800~1000 1.15
VSWR(±3%)
1700~2300 1.15
LSRC-50( 1 /2"S)
lambdA
Your Telecom Partner
Mechanical Properties
Diameter Over Dielectric(mm) 9
Diameter Over Jacket(mm) 13.3
Inner Conductor OD(mm) 3.6
Outer Conductor OD(mm) 12.1
Weight (kg/m) 0.2
Min bending radius single bending (mm) 17
Min bending radius repeated bending (mm) 55
Tensile strength(N) 800
Operating temperature (deg Celcius) -4o·c ~+ 7o•c
Electrical Properties
Charateristic impedance (0) 50±1
Relative propagation velocity (%) 82
Capacitance (PF/m) 81
Minimum insulation resistance(DC 500V 1 minute) 3000MO•km
Peak power rating (kW) 20
800~1000 1.15
VSWR(±3%)
1700~2300 1.15
LSHT-50(7/8"5) �
Mechanical Properties
lambdA
Your Telecom Partner
Electrical Properties
Charateristic impedance (0) 50±1
lambdA
Cable clamps
Your Telecom Partner
■ Feeder clamps are made of stainless steel and Anti-UV rubber, adopting special
technic of coating, widely used in the fix of RF cables. Applied in different operation
temperature.
1/2" 3*1/2" 16
1/2" 1*1/2" 16
1/2" 2*1/2" 16
Other Accessories
Item Description
Item Description
Item Description
Leaky coaxial cable is mainly used in the long, narrow and enclosed areas that conventional
antenna signals can not be effectively covered, for example, track traffic, tunnels, mines, build
ings and large edifices, and so on.
Leaky coaxial cable integrates the function of antenna and feeder cable. It has three functions,
(a) transmit electromagnetic wave, (b) launch electromagnetic wave, (c) receive outside spe
cific electromagnetic wave.
There are two kinds of leaky coaxial cable, radiating mode and coupling mode.
Cable Sheat--
Dielectric
1.
�-
I Outer Conductor
Inner with Slo
Conductor
..,..,_,too
.,...,,., -1---:::� 'I,:;,-,.....
■ LLCTSHY-50(7 /8")
■ LLCTCMY-50(1-1 /4")
■ LLCTSHY-50(1-1/4")
■ LLHTSMY-50-(1-5/8")
�\�--,/)
■ LLHTCHY-50(1-5/8") �
■ LLTAY-50Rl (7/8") . ''
-<="
■ LLTAY-50R2 (7/8")
■ LLTAY-50Rl (1-1/4")
■ LLTAY-50R2 (1-1/4")
LLCTSHY-50(7 /8") lambdA Your Telecom Partner
Advantages
• The product characterized long electromagnetic radiation distance and is suitable for the
coverage of enclosed areas, such as rail tunnels, high speed railway tunnels, underground
parking and so on . It has strong radiation perf ormance and uniform fluctuation in narrow
band .
• Best working frequency range: 800-1000 & 1700-2400MHz
Performances
• Structure
Cable type Radiating
Size 7/8"
Inner conductor material/ OD Copper tube/ 9.0mm
Insulating material Physical foamed polyethylene dielectric
Outer conductor material/ OD Overlapping copper foil/ 23.0mm
Jacket material LSOH polyolefin
Diameter over Jacket/ color 25.8mm/ black
Weight 490kg/km
• Mechanical characteristics
Tensile force >2000 N
Minimum bending radius, single bend 350mm
Indication of slot alignment Guides opposite to slots
Minimum distance to wall 100mm
Recommended clamp spacing 0.9m
Installation temperature -25-+ 6o'c
Operation temperature -40-+85'c
°
Storage temperature -70-+85c
• Electrical characteristics
Cut-off frequency 1.3-1.4GHz & Its multiples
Polarization Vertical
VSWR 1.3
Impedance 50±20
Encircle DC resistance 4.5O/km
Insulation dielectric strength 15000V (DC, lmin)
Minimum insulation resistance 5000 MO-km
Jacket spark test voltage 8000V (AC)
Peak power 91kW
Velocity 89 %
LLCTCMY-50(1-1 /4")
Advantages
• The product characterized long electromagnetic radiation distanc e and is suitable
for the coverage of enclosed areas, such as rail tunnels, high speed railway tunnels,
underground parking and so on. It has strong radiation performance and uniform
fluctuation in narrow band.
• Best working frequency range: 300~600 & 670~950MHz
Performances
• Structure
Cable type Radiating
Size 1-1/ 4"
Inner conductor material/ OD Copper tube/ 1 3.1 mm
Insulating material Physical foamed polyethylene dielectric
Outer conductor material/ OD Overlapping corrugated copper foil/ 33.6mm
Jacket material LSOH polyolefin
Diameter over Jacket I color 38.0mm/ black
Weight 800kg/km
• Mechanical characteristics
Tensile force >2 300 N
Minimum bending radius, single bend 500mm
Indication of slot alignment Guides opposite to slots
Minimum distance to wall 1 00mm
Recommended clamp spacing 1~1.2 m
Installation temperature -2 5~+6o·c
°
Operation temperature -40~+85 C
Storage temperature -70~+85'c
• Electrical characteristics
Cut-off frequency 51 0~550MHz
Polarization Vertical
VSWR 1.3
Impedance 50±2 0
Encircle DC resistanee 30/km
Insulation dielectric strength 15000V (DC, lmin)
Minimum insulation resistance 5000MO-km
Jacket spark test voltage 8000V (AC)
Peak power 2 00kW
Velocity 88%
Advantages
• T he product characterized long electromagnetic radiation distance and is suitable
for the coverage of enclosed areas, such as rail tunnels, high speed railway tunnels,
underground parking and so on. It has strong radiation performance and uniform
fluctuation in narrow band.
• Best working frequency range: 800-1 000 &1 7 00-2400MHz
Performances
• Structure
Cable type Radiating
Size 1-1/4"
Inner conductor material/OD Copper tube/ 1 3.1 mm
Insulating material Physical foamed polyethylene dielectric
Outer conductor material/OD Overlapping copper foil/ 33.1 mm
Jacket material LSOH polyolefin
Diameter over Jacket/ color 38.0mm/black
Weight 800kg/km
• Mechanical characteristics
Tensile force >2300 N
Minimum bending radius. single bend 500mm
Indication of slot alignment Guides opposite to slots
Minimum distance to wall 1 00mm
Recommended clamp spacing 1 -1 .2m
°
Installation temperature -25-+60 C
Operation temperature -40-+85"c
Storage temperature -7 0-+85"c
• Electrical characteristics
Cut-off frequency 1 .1-1.5 GHz
Polarization Vertical
VSWR 1.3
Impedance 50±20
Encircle DC resistance 3O/km
Insulation dielectric strength 1 5000V (DC, lmin)
Minimum insulation resistance 5000 MO-km
Jacket spark test voltage 8000V (AC)
Peak power 200kW
Velocity 88 %
LLHTSMY-50(1-5/8")
Advantages
• The product characterized long electromagnetic radiation distance and is suitable for
the coverage of enclosed areas, such as rail tunnels, high speed railway tunnels,
underground parking and so on. It has strong radiation performance and uniform
fluctuation in narrow band.
• Best working frequency range: 300-9 00 MHz
Performances
• Structure
Cable type Radiating
Size 1-5/ 8"
Inner conductor material/ OD Helical copper tube/ 17.3mm
Insulating material Physical foamed polyethylene dielectric
Outer conductor material/ OD Overlapping copper foil/ 43.5mm
Jacket material LSOH polyolefin
Diameter over Jacket/ color 48.0mm/ black
Weight 1000kg/km
• Mechanical characteristics
Tensile force >3000 N
Minimum bending radius, single bend 700mm
Indication of slot alignment Guides opposite to slots
Minimum distance to wall 100mm
Recommended clamp spacing 1~1.5m
Installation temperature -25-+60'c
Operation temperature -40-+85'c
Storage temperature -7o~+85'c
• Electrical characteristics
Cut-off frequency 510~530MHz & Its multiples
Polarization Vertical
VSWR 1.3
Impedance 50±20
Encircle DC resistance 30/km
Insulation dielectric strength 15000V (DC, lmin)
Minimum insulation resistance 5000 MO-km
Jacket spark test voltage 8000V (AC)
Peak power 310kW
Velocity 89%
Notes:
Coupling Loss & Atte1111atio11 is tested by thef,-ee-space method according to !EC 6ll96-4 Standa,ds.
lambdA Your Telecom Partner
LLHTCHY-50(1-5/8")
Advantages
•The product characterized long electromagnetic radiation distance and is suitable
for the coverage of enclosed areas, such as rail tunnels, high speed railway tunnels,
underground parking and so on . It has strong radiation performance and uniform
fluctuation in narrow band .
• Best working frequency range:800-1000 & 1700-2700MHz
Performances
• Structure
Cable type Radiating
Size 1-5/8"
Inner conductor material/ OD Helical copper tube/ 17.3mm
Insulating material Physical foamed polyethylene dielectric
Outer conductor material/ OD Overlapping corrugated copper foil/ 43.5mm
Jacket material LSOH polyolefin
Diameter over Jacket/ color 48.0 mm/ black
Weight 1000kg/ km
• Mechanical characteristics
Tensile force >3000 N
Minimum bending radius, single bend 700mm
Indication of slot alignment Guides opposite to slots
Minimum distance to wall 100mm
Recommended clamp spacing 1-1.5m
°
Installation temperature -25~+6 0 C
°
Operation temperature -40~+85 C
Storage temperature -70~+85"c
• Electrical characteristics
Cut -off frequency 1100~1500MHz
Polarization Vertical
VSWR 1.3
Impedance 50±20
Encircle DC resistance 30/km
lnsulation dielectric strength 15000V (DC, lmin)
Minimum insulation resistance 5000MO-km
Jacket spark test voltage 8000V (AC)
Peak power 310kW
Velocity 89 %
LLTAY-50Rl(7/8")
Advantages
• The product is applicable for the coverage of density in long, narrow and enclosed areas,
such as mines, buildings and elevators etc. It has little fluctuation of electromagnetic
density and uniform coverage in broadband.
• B est working frequency range: 50-3000 MHz
Perforrnances
• Structure
Cable type Coupling
Size 7/8"
Inner conductor material/OD Copper tube/ 9 .0mm
Insulating material Physical foamed polyethylene dielectric
Outer conductor material/OD Annular corrugated copper tube milled/single slots
Jacket material LSOH polyolefin
Diameter over Jacket I color 27.5mm I black
Weight 510kg/km
• Mechanical characteristics
Tensile force >1500 N
Minimum bending radius, single bend 300mm
Indication of slot alignment Guides opposite to slots
Minimum distance to wall 100mm
Recommended clamp spacing 0.9 m
Installation temperature -2s-+6o·c
°
Operation temperature -40-+8 5 C
Storage temperature -70~+8 s·c
• Electrical characteristics
Operating frequency 50~3000 MHz
Polarization Vertical
VSWR 1.3
Impedance 50±20
Encircle DC resistance 30/km
Insulation dielectric strength 6000V (DC, lmin)
Minimum insulation resistance 5000MO-km
Jacket spark test voltage 8000V (AC)
Peak power 9 lkW
Velocity 88 %
Coupling loss & A11e1111arion is tesred by thefree-space method according r o JEC 61196-4 Standards.
lambdA Your Telecom Partner
LLTAY-50R2(7/8")
Advantages
• The product is applicable for the coverage of density in long, narrow and enclosed areas,
such as mines, buildings and elevators etc. It has little fluctuation of electromagnetic
density and uniform coverage in broadband.
• B est working frequency range: 50-3000 MHz
Perforrnances
• Structure
Cable type Coupling
Size 7/8"
Inner conductor material/OD Copper tube/ 9 .0mm
Insulating material Physical foamed polyethylene dielectric
Outer conductor material/OD Annular corrugated copper tube milled/single slots
Jacket material LSOH polyolefin
Diameter over Jacket I color 27.5mm I black
Weight 510kg/km
• Mechanical characteristics
Tensile force >1500 N
Minimum bending radius, single bend 300mm
Indication of slot alignment Guides opposite to slots
Minimum distance to wall 100mm
Recommended clamp spacing 0.9 m
Installation temperature -2s-+6o·c
°
Operation temperature -40-+8 5 C
Storage temperature -70~+8 s·c
• Electrical characteristics
Operating frequency 50~3000 MHz
Polarization Vertical
VSWR 1.3
Impedance 50±20
Encircle DC resistance 30/km
Insulation dielectric strength 6000V (DC, lmin)
Minimum insulation resistance 5000MO-km
Jacket spark test voltage 8000V (AC)
Peak power 9 lkW
Velocity 88 %
Coupling loss & A11e1111arion is tesred by thefree-space method according r o JEC 61196-4 Standards.
lambdA
Your Telecom Partner
Performances
• Structure
Cable type Coupling
Size 1-1 /4"
Inner conductor material/ OD Copper tube/ 13.1mm
Insulating material Physical foamed polyethylene dielectric
Outer conductor material/ OD Annular corrugated copper tube milled/ single slots
Jacket material LSOH polyolefin
Diameter over Jacket/ color 38.4 mm / black
Weight 850kg/ km
• Mechanical characteristics
Tensile force >26 00N
Minimum bending radius, single bend 500mm
Indication of slot alignment Guides opposite to slots
Minimum distance to wall 100mm
Recommended clamp spacing 1~1.2m
Installation temperature -25~+6 o·c
°
Operation temperature -40~+85 C
°
Storage temperature -7 0~+85 c
• Electrical characteristics
Operating frequency 50~3000MHz
Polarization Vertical
VSWR 1.3
Impedance 50±20
Encircle DC resistance 30/km
Insulation dielectric strength 10000V (DC, lmin)
Minimum insulation resistance 5000MO-km
Jacket spark test voltage 8000V (AC)
Peak power 200kW
Velocity 88%
Coupling Loss & A11en11alion is tested by the free-space method according to JEC 61196-4 Standards.
lambdA Your Telecom Partner
LLCTAY-50R1(1-1 /4")
Advantages
• The product is applicable for the coverage of density in long, narrow and enclosed areas,
such as mines, buildings and elevators etc. It has little fluctuation of electromagnetic
density and uniform coverage in broadband .
• Best working frequency range: 50-3000MHz
Performances
• Structure
Cable type Coupling
Size 1-1/4"
Inner conductor material I OD Copper tube / 13.1 mm
Insulating material Physical foamed polyethylene dielectric
Outer conductor material/ OD Annular corrugated copper tube milled/single slots
Jacket material LSOH polyolefin
Diameter over Jacket / color 38.4mm / black
Weight 8S0 kg/km
• Mechanical characteristics
Tensile force >2600 N
Minimum bending radius, single bend 500mm
Indication of slot alignment Guides opposite to slots
Minimum distance to wall 100mm
Recommended clamp spacing 1-1.2m
Installation temperature -25-+6o·c
°
Operation temperature -40-+85 C
°
Storage temperature -70-+85 c
• Electrical characteristics
Operating frequency 50-3000MHz
Polarization Vertical
VSWR 1.3
Impedance 50±20
Encircle DC resistance 30/km
Insulation dielectric strength 10000V (DC. lmin)
Minimum insulation resistance 5000MO-km
Jacket spark test voltage 8000V (AC)
Peak power 200 kW
Velocity 88 %
Coupling loss & Attenuation is tested by the free-space method according to !EC 6II96-4 Standards.
lambdA
Your Telecom Partner
LLCTAY-50R3(1-1 /4")
Advantages
• The product is applicable for the coverage of density in long, narrow and enclosed areas,
such as mines, buildings and elevators etc . It has little fluctuation of electromagnetic
density and uniform coverage in broadband .
• B est working frequency range: 50-3000MHz
Performances
• Structure
Cable type Coupling
Size 1-1 /4"
Inner conductor material/ OD Copper tube/ 13.1mm
Insulating material Physical foamed polyethylene dielectric
Outer conductor material/ OD Annular corrugated copper tube milled/ single slots
Jacket material LSOH polyolefin
Diameter over Jacket/ color 38.4 mm / black
Weight 850kg/ km
• Mechanical characteristics
Tensile force >26 00N
Minimum bending radius, single bend 500mm
Indication of slot alignment Guides opposite to slots
Minimum distance to wall 100mm
Recommended clamp spacing 1~1.2m
Installation temperature -25~+6 o·c
°
Operation temperature -40~+85 C
°
Storage temperature -7 0~+85 c
• Electrical characteristics
Operating frequency 50~3000MHz
Polarization Vertical
VSWR 1.3
Impedance 50±20
Encircle DC resistance 30/km
Insulation dielectric strength 10000V (DC, lmin)
Minimum insulation resistance 5000MO-km
Jacket spark test voltage 8000V (AC)
Peak power 200kW
Velocity 88%
Coupling Loss & A11en11alion is tested by the free-space method according to JEC 61196-4 Standards.
lambdA
Your Telecom Partner
RG-213 U -
CONSTRUCTION
Item Material Diameter (mm)
Inner Conductor Stranded Bare Copper 7/0.75
Dielectric Solid PE 7.25
Shield 85% Bare Copper Braid
8.15
16x9x0.14mm (Pitch 23mm)
Jacket PVC (Black, Flame Retardant) 10.30
Thickness 1.20
ELECTRICAL CHARACTERISTICS
Capacitance (pF/m) 101.0
Impedance (0) so± 3
Velocity of Propagation (%) 66.0
Conductor OCR (Ohm/km) < 5.6
Outer Shield DCR (Ohm/km) < 3.9
Max Operating Frequency (MHz) 11000.0
Max Operating Voltage (RMS) 3700.0
Operating Temp Range (0C) -40 to 85
ATTENUATION ( 20 °C)
Frequency(MHz) Max Attenuation (dB/lOOm)
10 1.8
so 4.3
100 6.2
200 9.5
400 13.8
600 18.2
860 22.3
1000 24.5
1500 31.5
2000 36.4
3000 46.6
CONSTRUCTION
Item Material Diameter (mm)
Inner Conductor Tinned Copper 19/0.18
Dielectric Solid PE 2.95 ± 0.1
Shield 95% Tinned Copper Braid
3.55
16x7x0.12mm {Pitch 15.8mm)
Jacket PVC-RoHS & Flame resistant 5.0 ± 0.1
Thickness 0.73
ELECTRICAL CHARACTERISTICS
Capacitance (pF/m) 101.0
Impedance (O) 50.0
Velocity of Propagation (%) 66.0
Conductor OCR (Ohm/km) < 35
Outer Shield OCR (Ohm/km) 13.5
Max Operating Frequency (MHz) 1000.0
Max Operating Voltage (RMS) 1900.0
Operating Temp Range ( 0 C) -40 to 85
ATTENUATION ( 20 °C)
Frequency(MHz) Max Attenuation (dB/lOOm)
10 4.3
so 10.9
100 15.1
200 21.0
400 31.2
600 39.6
860 50.6
1000 52.0
ELECTRICAL CHARACTERISTICS
Capacitance(pF/m) 101.0
Impedance(0) 50.0 ± 2
Velocity of Propagation(%) 66.0
ConductorDCR(Ohm/km) 318.2
Outer Shield OCR(Ohm/km) 35.1
Max Operating Frequency (MHz) 1000.0
Max Operating Voltage(RMS) 1500.0
Corona Extinction voltage(VRMS) 1500.0
Voltage Withstand(VRMS) 2000.0
Spark Test(VRMS) 2000.0
Operating Temp Range(0C) -40 to 85
ATTENUATION ( 20 °C)
Frequency(MHz) Max Attenuation(dB/lOOm)
10 10.8
so 20.0
100 21.0
200 42.5
400 55.6
600 68.8
860 86.1
1000 96.2
LW- LMR400
Reference:
rl'
-.
•.,_ - ,
II
tt �� �
Description:
LOW LOSS RADIFREQUENCY COAXIAL CABLE
CHARACTERISTICS
Construction Specifications Diametro 2,74 ± 0,02 mm
Description Material In. (mm) Diametro 7,25 ± 0,01 mm
Inner Conductor Solid BCCAI 0.108 (2.74)
Dielectr:ic Foam PE 0.285 (7.24) Diametro 8,00 ± 0, 15 mm
Outer Conductor Aluminum Tape 0.291 (7.39)
Overall Braid Tinned Copper 0.320 (8.13) 90%
Diametro 10,16 ± 0,20 mm
Jacket (see table above) 0 .405 (10.29)
Mechanical Specifications
Specification Description
Minimum Bend Radius 1 inches (25.4 mm)
Bending Movement 0.5 ft lbs (0.68 N-m)
Weight 0.068 lb/ft (0.10 kg/m)
Tensile Strength 160 lbs (72.6 kg)
Flat Plate Crush 40 lb/inch (0.71 kg/mm)
Environmental Specifications
Spec1f1cabon Description
Installation Temp Range -40 ° I +185 ° F (-40 ° / +85 ° C)
Storage Temp Range -94 ° I +185 ° F (-70 ° / +85 ° C)
Operating Temp Range -40 ° I +185 ° F (-40 ° / +85 ° C)
Electrical Specifications
Spec1f1cabon Description
Voltage Withstand 2500 VDC
Peak Power 16 kW
Jacket Spark 8000 VRMS
Attenuation chart
Frequency (MHz) 30 50 150 220 450 900 1500 1800 2000 2500 5800 Reaction to Fire:
AttenuationdB/100 ft 0. 7 0.9 1. 5 1.9 2.7 39 5. 1 5.7 6.0 6 6 1 0. 8
AttenuatlondB/100m 22 29 50 6.1 89 128 168 18.6 19.6 22.2 355 Clase: Eca
Avg. Po-r kW 3.33 2.57 1.4 7 1. 2 0 0.63 0.58 0.44 0.40 0 .3 7 0.33 0.21
En 50575:2014 A1:2016
Coaxial cable assemblies lambdA
Your Telecom Partner
n
CONECTORS
ADAPTERS
< PRODUCT DETAILS > SURGE PROTECTOR SP-1
SPLITTER INMS 8-2
0
TUBE SPLITTERS
OJ
><
-··
OJ
"'
1111111
R
CONNECTORS lambdA
Your Telecom Partner
BNC (male) RG58 BNC (male) RG58 BNC (male) RG58 BNC (female)
crimp plastic crimp
• i ons
Impedance 500 500 500 500
Max. frequency 4.0 GHz 4.0 GHz 4.0 GHz 4.0 GHz
Dielectric PTFE PTFE PTFE PTFE
Mount (cable/panel) RG 58/U RG 58/U RG 58/U RG 58/U
Contact/Body plating Silver/Nickel Silver/Nickel Silver/Nickel Silver/Nickel
>.\
ons
Impedance 750 500 500 500
Max. frequency 0.2 GHz 0.2 GHz 0.5 GHz 0.5 GHz
Dielectric PTFE PTFE PTFE PTFE
Mount (cable/panel) PK 75-2-14 T 0201 RG 58/U RG 58/U
Contact/Body plating Silver/Nickel Gold/Gold Silver/Nickel Silver/Nickel
CONNECTORS lambdA
Your Telecom Partner
ons
Impedance 500 500 500 500
Max. frequency 12.0 GHz 12.0 GHz 12.0 GHz 12.0 GHz
Dielectric PTFE PTFE PTFE PTFE
Mount (cable/panel) RG 58/U RG 58/U RG 58/U RG 58/U
Contact/Body plating Silver/Nickel Silver/Nickel Silver/Nickel Silver/Nickel
"l ons
Impedance 50 o 500 500 500
Max. frequency 12.0 GHz 12.0 GHz 12.0 GHz 12.0 GHz
Dielectric PTFE PTFE PTFE PTFE
Mount (cable/panel) RG 213/U RG 213/U RG 213/U RG 213/U
Contact/Body plating Silver/Nickel Silver/Nickel Silver/Nickel Silver/Nickel
ons
Impedance 50 o 500 500 500
Max. frequency 12.0 GHz 12.0 GHz 12.0 GHz 12.0 GHz
Dielectric PTFE PTFE PTFE PTFE
Mount (cable/panel) panel panel panel RG 213
Contact/Body plating Silver/Nickel Silver/Nickel Silver/Nickel Silver/Nickel
CONNECTORS lambdA
Your Telecom Partner
.,.. - ons
Impedance 500 500 50 o 500
Max. frequency 27.0GHz 27.0GHz 27.0GHz 27.0GHz
Dielectric PTFE PTFE PTFE PTFE
Mount (cable/panel) RG 58/U, RG 174 RG 58/U, RG 174 RG 58/U, RG 174 RG 58/U, RG 174
Contact/Body plating Silver/Nickel Silver/Nickel Silver/Nickel Silver/Nickel
•.tt: - ons
Impedance 500 500 50 o 500
Max. frequency 27.0GHz 27.0GHz 27.0GHz 27.0GHz
Dielectric PTFE PTFE PTFE PTFE
Mount (cable/panel) RG 58/U, RG 174 RG 58/U, RG 174 RG 58/U, RG 174 RG 58/U, RG 174
Contact/Body plating Silver/Nickel Silver/Nickel Silver/Nickel Silver/Nickel
CONNECTORS iambdA
Your Telecom Partner
SMA (female) angle TNC (female) TNC (male) TNC (male) RG58
PCB bulkhead crimp
ons
Impedance 50 o 500 500 500
Max. frequency 27.0 GHz 12.0 GHz 12.0 GHz 12.0 GHz
Dielectric PTFE PTFE PTFE PTFE
Mount (cable/panel) PCB panel RG 58/U, RG 174 RG 58/U
Contact/Body plating Gold/Gold Silver/Nickel Silver/Nickel Silver/Nickel
a ons
Impedance 500 500 500 500
Max. frequency 12.0 GHz 12.0 GHz 12.0 GHz 12.0 GHz
Dielectric PTFE PTFE PTFE PTFE
Mount (cable/panel) RG 213/U RG 58/U RG 58/U RG 213/U
Contact/Body plating Silver/Nickel Silver/Nickel Silver/Nickel Silver/Nickel
UHF (female) flange UHF (female) UHF (female) RG58 UHF (female) RG58
panel bulkhead crimp
•
..
✓
ons
Impedance 50 o 500 500 500
Max. frequency 0.2 GHz 0.2 GHz 0.2 GHz 0.2 GHz
Dielectric PTFE PTFE PTFE PTFE
Mount (cable/panel) panel panel RG 58/U RG 58/U
Contact/Body plating Silver/Nickel Silver/Nickel Silver/Nickel Silver/Nickel
CONNECTORS lambdA
Your Telecom Partner
UHF (female) RG213 UHF (male) RG58 UHF (male) RG58 UHF (male) RG213
crimp
ons
Impedance 500 500 500 500
Max. frequency 0.2 GHz 0.2 GHz 0.2 GHz 0.2 GHz
Dielectric PTFE PTFE PTFE PTFE
Mount (cable/panel) RG 213/U RG 58/U RG 58/U RG 213/U
Contact/Body plating Silver/Nickel Silver/Nickel Silver/Nickel Silver/Nickel
UHF (male) RG213 UHF (male) right UHF (male) LDF4- 7/16 (female) RG213
crimp angle 50A
-- - - c!!'""'·ons
Impedance 500 500 500 500
Max. frequency 0.2 GHz 0.2 GHz 0.2 GHz 4.0 GHz
Dielectric PTFE PTFE PTFE PTFE
Mount (cable/panel) RG 213/U RG 213/U LDF4-50A RG 213/U
Contact/Body plating Silver/Nickel Silver/Nickel Silver/Nickel Silver/Nickel
Impedance 500
Max. frequency 4.0 GHz
Dielectric PTFE
Mount (cable/panel) RG 213/U RG 58/U RG 213/U
Contact/Body plating Silver/Nickel Silver/Nickel Silver/Nickel
ADAPTERS lambdA
Your Telecom Partner
A Surge Protector is a device that shields your installations and hardware devices
from surges in electrical power, or transient voltage. If a spike or surge in the voltage
occurs, causing the voltage to surpass the norm, damage can occur to the installed
equipment. Electrical surges can occur from a number of sources - lightning,
thunderbolt, electrical surpass, etc. The Surge Protection device should be installed
between the antenna and the hardware appliance.
ORDERING DESIGNATIONS
Type Input connector Output connector
SP-1 N N (female) N (female)
SP-1 N female-male N (female) N (male)
SP-1 N long N (female) N (female) long thread
SP-1 N male N (male) N (male)
SP-1 BNC BNC (female) BNC (female)
SP-1 UHF UHF (female) UHF (female)
SPLITTER INMS.8-2 lambdA
Your Telecom Partner
Power Splitters