You are on page 1of 4

CTC door controller manual

1. Parameters debug:
① Connect HHT to the CTC board CN10 connector
in the right side.

② Initialize program:
In HHT select
[2]PROGRAM/4.FACTORY/34.INIT EEPROM,set the OFF to ON, then press
ENTER on HHT, after initialize press RESER button on the CTC board.

Before initializing After initializing

NOTE:

you should input password to enter menu ”FACTORY” following steps below:

Select FACTORY

Press UP or DN to

input 2

Press UP or DN to

input 3

Enter menu you can see

the first parameter


③ MOTOR select:In the HHT menu select [2]PROGRAM/3.MOTOR/1. DOOR TYPE
SELECT,chose the suitable car door motor type in the field.

Motor select interface

Door type meaning:

M1 :400W —— Side–open door

M2 :200W —— Center-open door


④ RATIO CHECK setting:In the HHT menu select [2]PROGRAM/4. FACTORY/28.
RATIO CHECK ,change the “OFF” setting into“ON”。

⑤ Setting door opening type:depend on the suitable door type of elevator. In the HHT
menu select:[2]PROGRAM/4. FACTORY/29. OPENING LENGTH select“CENTER
OPEN”or“SIDE OPEN”。

CENTER OPEN SIDE OPEN


⑥ Door width setting:depend on the actual measured door width,In the HHT menu
select:[2]PROGRAM/4. FACTORY /30. DOOR WIDTH input the measured door
width parameter.

⑦ Check the 01 MONITOR / 01 BASIC / SPEED FBK value (+) during the door
opening.
(if feedback value is (-), set 02 PROGRAM / 04 FACTORY / 21ENC DIRECTION data i

nto „BA ORDER‟.)


Speed feedback interface Change encoder direction interface

⑧ Check the door closed or not.


(Checking method :check door close limit switch LED on or not,also check upper

right part CTC board door close limit switch LED on or not.)

Door close limit LED

⑨ In the HHT menu select 02 PROGRAM / 04 FACTORY / 23 MEASURE START.


(Door opening length measure mode: low speed open and close door)

⑩ After finish the length measurement,check the following parameter.


- Check 01 MONITOR / 01 BASIC / LENGTH MEASURE data „Done‟ or not. If data is

„Needed', it means the measurement haven‟t done,repeat the progress again.

- Check 01 MONITOR / 04 TRIP DATA / OPENING LENGTH data close to sensor me

asured distance or not. If two value have huge difference,check parameter and i

nitialize again.
⑪ After the length measurement, press the RESET button on CTC board, all
commissioning job for door controller is finished.

2. Operation check
1) Manual operation
During manual operation mode please set the car top junction box “inspection/auto”
switch in inspection mode.
a) Car top open and close door operation
Car top inspection switch during inspection mode, the car top door switch enable t

o use. If the door zone signal doesn‟t exist, so the door opening signal disable to

use.
b) HHT door open close operation
①enable HHT door open and close function: 4.FACTORY→18.DRV WITH HHT→ON

②The order setting in the following:4.FACTORY→19 DRIVING TEST→

OPEN COMMAND:open door command; CLOSE COMMAND:close door comman

d; NO COMMAND:Stop running.

③Door motor running adjust:observation during the door running, dose the door vi

bration or not,if it exist vibration you can change the 4.FACTORY→05. SYSTEM J

M value to decrease vibration。

④Check 4.FACTORY→2 CLOSE TQ LIMIT to make sure it is 50%,too high of this n

umber may cause the door driving belt broken when door jam or belt loosed

You might also like