Professional Documents
Culture Documents
1. Parameters debug:
① Connect HHT to the CTC board CN10 connector
in the right side.
② Initialize program:
In HHT select
[2]PROGRAM/4.FACTORY/34.INIT EEPROM,set the OFF to ON, then press
ENTER on HHT, after initialize press RESER button on the CTC board.
NOTE:
you should input password to enter menu ”FACTORY” following steps below:
Select FACTORY
Press UP or DN to
input 2
Press UP or DN to
input 3
⑤ Setting door opening type:depend on the suitable door type of elevator. In the HHT
menu select:[2]PROGRAM/4. FACTORY/29. OPENING LENGTH select“CENTER
OPEN”or“SIDE OPEN”。
⑦ Check the 01 MONITOR / 01 BASIC / SPEED FBK value (+) during the door
opening.
(if feedback value is (-), set 02 PROGRAM / 04 FACTORY / 21ENC DIRECTION data i
right part CTC board door close limit switch LED on or not.)
asured distance or not. If two value have huge difference,check parameter and i
nitialize again.
⑪ After the length measurement, press the RESET button on CTC board, all
commissioning job for door controller is finished.
2. Operation check
1) Manual operation
During manual operation mode please set the car top junction box “inspection/auto”
switch in inspection mode.
a) Car top open and close door operation
Car top inspection switch during inspection mode, the car top door switch enable t
o use. If the door zone signal doesn‟t exist, so the door opening signal disable to
use.
b) HHT door open close operation
①enable HHT door open and close function: 4.FACTORY→18.DRV WITH HHT→ON
d; NO COMMAND:Stop running.
③Door motor running adjust:observation during the door running, dose the door vi
bration or not,if it exist vibration you can change the 4.FACTORY→05. SYSTEM J
umber may cause the door driving belt broken when door jam or belt loosed