Specific Examination Questions

NDT Method:Ultrasonic Testing


Name:Debjyoti Sengupta
Date:12.01.2023
Duration:30 mins
Type of Questions: Specific
Level: III
Organisation: ArcVac ForgeCast(P) LTD

1 As per ISO 16827:2014, the gap between probe and surface should be
a Less than 0.5 micron
b More than 0.5 mm
c ≥0.0005 m
d ≤0.0005 m

2 As per ISO 16827:2014,an indication is observed having a major axis dimension of 15mm and minor axis dimension of 2mm. Considering the
dimensions given, what will be the alignment of the indication
a Direction of maximum echo height
b Circumferencial direction
c Axial direction
d None

3 As per ISO 16827:2014, discontinuity can be classified as


a Elongated
b Point
c only a and b
d non-planar

4
As per ISO 16827:2014, maximum echo height technique is only applicable if
a The shape and orientation of discontinuity are not favourable for reflection
b The basic shape and orientation of reference target are similar to actual discontinuity to be evaluated
c Both a and b
d None

5 As per ISO 16810:2012, frequency and dimension of the transducer must be such that
a the near field length shall be smaller than the thickness of the object
b the near field length shall be larger than the thickness of the object
c the near field length shall equal the thickness of the object
d None of the above

6 As per ISO 16827:2014, for sizes of indications less than 6dB beam width, technique for sizing to be implemented will be
a 6dB drop method
b Maximum echo height technique
c 2dB drop method
d None of the above

7
As per ISO 10228-3:2016, test procedure shall have the following details as a mandatory requirement

a reference documents
b couplant
c discontinuity charecterization
d all of the above

8 As per ISO 10228-3:2016,allowable surface finish for quality class 4 is


a ≤12.5µm
b .=6.3µm
c ≤25µm
d ≥12.5µm

9 As per ISO 10228-3:2016, methods that can be used to establish sensitivity for scanning are:
a Tandem
b DGS
c DAC

1 of 2
d Both b and c

10 As per ISO 10228-3:2016,for type 3b and 3c hollow cylindrical shapes are to be inspected for 100% coverage by:
a 100% around 360 degree on OD and one lateral face
b 100% around 360 degree on ID and one lateral face
c Both ID, OD and lateral faces
d Only lateral faces

11 As per ISO 10228-3:2016, scanning was performed using a normal beam probe. An isolated indication was observed to have an ERS value of
2.0. Indication as per Quality class 4 is to be:
a Recorded
b Recorded and Accepted
c Accepted
d Recorded and Rejected

12 As per ISO 10228-3:2016, scanning was performed using a normal beam probe. An extended indication was observed to have an ERS value of
3.02. Indication as per quality class 3 is to be:
a Recorded
b Recorded and Accepted
c Accepted
d Recorded and Rejected

13 Examination as per TL901 Version 5.00 is to be carried out on parts


a With maximum contouring
b With minimum contouring
c With no contouring
d None of the above

14 Calibration block as per TL 901 Version 5.00 must meet the temperature criterion on which of the following points.
a Calibration block must equal test piece temperature
b Calibration block must be less than test piece temperature
c Calibration block must be within a tolerance of ± 14 degrees.
d None of the above

15 SNR as per TL 901 Version 5.00 must be


a 2˸1
b 3˸1
c 1˸1
d 5.4dB

16 Following couplants are permitted as per TL 901 Version 5.00


a Pure water
b Oil
c pastes
d Both b and c

17 An indication is observed at a depth of 15mm in a job having dimensions(594 x 343 x 351). Indication is observed to have ERS of 1.6mm. The
indication as per TL-901 Rev 5 is to be
a Accepted
b Recorded
c Rejected
d None of the above

18 An indication is observed at a depth of 115mm in a job having dimensions(594 x 343 x 351). Indication is observed to have ERS of 2.0mm and
having a BWR of 8dB. The indication as per TL-901 Rev 5 is to be
a Accepted
b Recorded
c Rejected
d None of the above

19
As per EN ISO 22232-3:2021-09, frequency of beam angle test is:
a Daily
b Weekly
c Monthly
d As per scanning requirement

20 An indication was observed at a depth of 200mm from OD in a job of dimension ø670mm X ø263mm X 275mm. The indication showed an ERS
value of 1.0mm FBH. Considering the BWR and Sensitivity to be within acceptable range, what action is to be taken with the indication as per TL
211 Rev.5
a Accept
b Record
c Reject
d Register
Prepared By: Sreemoy Saha Signature: