You are on page 1of 3

Code / Clave: JOHN DEERE CONDOR-5.

0 ESTRUCTURA
Date/Fecha: Rev. Date/Fecha de rev:
30-sep-22 30-sep-22
Rev: Page/Página:
0 1

SUBMITTAL 5.3 ESTRUCTURA

Project: JOHN DEERE CONDOR (Ramos Arizpe)


Issued by: Metalic / Jose Maria Flores Approval deadline: 30/09/2022

DESCRIPTION

NAVE PRINCIPAL
SISTEMA DE CUBIERTA

DECK PERFIL RECTANGULAR 7.2 PANEL


ESPECIFICACIONES DE PRODUCTO 7.2 PANEL
Product Specifications
• Applications: Roof and Wall
• Coverage Widths: 36”
• Rib Spacing: 7.2” on center
• Rib Height: 1-½”
• Fastening System
• Gauges: 22
• Color Polar White• Signautre 200• Finished Smooth
• Roof Performance - Florida Approval FM 4471

DELIVERED TIME 8 -10 WEEKS

ENCLOSED:
Catalog specifications R
Drawings or sketches R
Ing.Margarita Mendoza Other 

FOR APPROVAL SIGNATURE PLEASE CHECK

Approved 
Accepted as noted 
Ing. Francisco Anaya Rejected 

COMMENTS

Davisa Desarrollos Inmobiliarios * José Sarmiento 1384 Col. Rancho de Peña


Saltillo, Coahuila * Tel. 52 844 134 2600
EXPOSED
FASTENING
SYSTEM

7.2 PANEL

When your design calls for a commercial or industrial exposed fastener panel, the 7.2 Panel is an ideal choice.
This panel offers versatility and functionality for roofs and walls. The symmetrical rib 7.2 Panel offers excellent
spanning and cantilever capabilities, making it an excellent choice for carports and walkway canopies. When
used on walls, the 7.2 Panel is typically ordered as “reverse rolled” and can be installed either vertically or
horizontally.

Features and Benefits:


• U
 L 580 rating is available, as well as UL 790, Class A for external fire,
roof assembly for UL 263 for internal fire and the UL 2218 Class 4
impact rating.

• 7 .2 Panel carries Florida approval.

Product Specifications • Gauges: 24 (standard); 29, 26, 22


• Applications: Roof and Wall (optional)
36" • Coverage Widths: 36” • Finishes: Smooth (standard);
7.200" 45° • Rib Spacing: 7.2” on center Embossed (optional)
2.146" (TYP)
" • Rib Height: 1-½” • Coatings: Galvalume Plus®,
.63
• Minimum Slope: ½:12 Signature® 200, Signature® 300,
1 ¹⁄₂" 2.146"
• Panel Attachment: Exposed Signature® 300 Metallic
Fastening System

844-327-1748 | mbci.com | shop.mbci.com


7.2 PANEL
EXPOSED FASTENING SYSTEM
CATEGORY CHARACTERISTIC TEST METHOD PURPOSE RESULT
Determines the air leakage rates of exterior windows,
0.0000 cfm/ft 2 at 6.24 psf static pressure
Air leakage ASTM E283 curtain walls, and doors under specified air pressure
0.239 cfm/ft 2 at 15.00 psf static pressure
differences across the specimen

Determines the resistance of exterior windows,


No uncontrolled water penetration through
curtain walls, skylights, and doors to water
ENVIRONMENTAL Water Penetration ASTM E331
penetration when water is applied under uniform
the panel joints at a static pressure of 13.24
psf
static air pressure difference

Determines Impact Resistance of prepared Roof


Impact Resistance UL 2218 Class 4 Rating
Covering Materials

Standard for Standard Test Methods for Fire Tests of


Room Fire Performance UL 790 See Class A Fire Rating Data Sheet
Roof Coverings

FIRE RESISTANCE For use in Design Nos. P225, P227, P230,


Standard for Fire Tests of Building Construction and P237, P265, P268, P508, P510, P512, P701,
Room Fire Performance UL 263
Materials P711, P720, P722, P726, P731, P734, P801,
P815, P819.

Provides a standard procedure to evaluate or


See Section Properties and Allowable Load
Uplift Resistance AISI S100 confirm structural performance under uniform static
Table Section
air pressure difference
STRUCTURAL
North American Specification for the Design of Cold- See Section Properties and Allowable Load
Gravity Loads AISI S100
Formed Steel Structural Members Table Section

Roof Performance Determines the uplift resistance of roof assemblies Class 90 Rating - Construction
UL 580
-Underwriters Laboratories consisting of the roof and roof coverings materials Number 244

ROOF LISTINGS Florida product approval is the approval of products


UL 580
Roof Performance - Florida and systems, which comprise the building envelope
FM 4471 See FL# 15159
Approval and structural frame, for compliance with the
UL 790
structural requirements of the Florida Building Code.

Descriptions and specifications contained herein were in effect at the time this publication was approved for printing. In a continuing effort to refine and improve products, MBCI reserves the right to discontinue
products at any time or change specifications and/or designs without incurring obligation. To ensure you have the latest information available, please inquire or visit our website at www.mbci.com. Application details