You are on page 1of 16

GALVAMET

PRODUCT CATALOGUE

01.

02.

03.

04.

05.
GALVAMET AMERICA CORPORATION

Galvamet America Corporation offers a complete line of insulated metal


panels for commercial, industrial and cold-storage applications and has
an estimated production capacity of 10 million square feet per year.
Galvamet is a true single source supplier of quality insulated wall and
roof panels.

Based in Shelbyville, Indiana, the Galvamet facility is equipped with a


state-of-the-art, fully automated, foamed-in-place technology. Galvamet
produces FM and UL approved panels that feature an isocyanurate rigid
foam core with galvanized steel face sheets. With a continuos production
line for panels and a line for slitting metals, Galvamet controls the entire
production process to ensure consistent quality, reliability and on-time
delivery.

GALVAMET PLANT
THIS 80,000 sq.ft. PANEL MANUFACTURING FACILITY IS LOCATED IN SHELBYVILLE, IN.
THE GALVAMET CAMPUS IS ON TWO ACRES OF LAND AND INCLUDES THE MANUFACTURING
PLANT, WAREHOUSE AND TRUCK LOADING AREA.
GALVAMET FEATURES

MATERIALS AND FINISHES


Galvamet panels are pre-painted ASTM A653 grade 37, G70 or G90
galvanized steel sheet, 26 gauge. Standard texture: wall panel exterior –
face embossed and roof panel exterior – smooth, liner embossed.

CORE INSULATION
Galvamet CFC free foam-in-place isocyanurate with a nominal density
of 2.4 lbs/cu ft is offered in different thickness with excellent insulation
values. CFC free foam has significantly reduced ozone depleting properties.

COATING AND SURFACING


To ensure the lasting quality of our panels, the exterior face sheet is
siliconized polyester or 70% Kynar 500 / Hylar5000, 0.8 mils film
thickness and 0.2 mils primer thickness. The interior is USDA compliant
imperial white siliconized polyester, 0.8mils film and 0.2mils primer.

USES AND APPLICATIONS


Galvamet insulated metal panels are designed for commercial, industrial
and cold-storage roof or wall applications and can be used in both new
and retro fit constructions. Galvamet panels may also be used for cold
storage buildings, food processing plants and other applications where
temperature control and insulation values are critical. Other applications
include: manufacturing facilities, distribution warehouses, aircraft
hangers, equipment maintenance buildings and schools.
OUR PRODUCTS

Hi Rib Panel
Hi Rib panel is a versatile panel that can be used as a wall or roof
panel. The ribs of the panel produce an extremely strong section
that can span long distances between wall girts and roof joists/purlins.
It is available up to 6” thick, making it ideal for applications needing
strong, well insulated metal walls and roofs. This system can be com-
pleted with the innovative GT-1 connection which mates the roof and
wall in a continuous curve eliminating eave trim and gutters.

01.

FEATURES AND BENEFITS


• Hi Rib panel is available in thicknesses up to 6”.

• The panel’s structural fasteners give it the strength to meet FM and UL


uplift requirements; batten caps are an available option.

• Hi Rib panel is also available in thickness as little as 1.5” making it a


rugged and economical insulated roof panel for industrial and warehous-
ing projects when the budget is critical.

w w w w
Thickness INSULATION FACTORS PANEL
(in) WEIGHT
R U (PSF)
SPAN (Ft)
ft2.h.ºF BTU
BTU ft2.h.ºF 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 15.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 15.0
1.5 13 0.077 2.13 41 31 24 44 34 28 23
2 17 0.058 2.23 56 43 34 27 22 59 46 38 31 26 22
2.5 22 0.046 2.33 71 55 44 35 29 23 74 59 48 40 33 28 24
3 26 0.039 2.44 86 67 54 44 36 30 25 21 89 71 58 49 41 35 30 26 23
4 34 0.029 2.65 116 92 75 62 51 43 36 31 26 22 119 96 79 67 57 49 43 37 33 29 25
6 52 0.019 3.07 175 144 118 99 83 71 61 53 46 40 35 175 144 122 104 90 79 68 60 54 48 43
NOTES: 1. BASED ON HI-RIB 39.37 IN. WIDE ROOF PANEL WITH 26 GA. EXTERIOR AND INTERIOR STEEL FACERS. (MIN. FY= 37 KSI AS PER ASTM A653). 2. STEEL FACERS ARE
PREPAINTED GALVANIZED STEEL AS PER ASTM A653 GRADE 37 (FY= 37 KSI MIN). ELASTICITY MODULUS IS 29, 000 KSI. 3. LOAD TABLES WERE DERIVED FROM ASTM E72
STRUCTURAL TESTING. ALLOWABLE LOADS WERE OBTAINED WITH 2.5 BENDING SAFETY FACTOR 3.0 SHEAR SAFETY FACTOR, AND DEFLECTION LIMIT OF L/240. 4. THERMAL LOAD
EFFECT DUE TO TEMPERATURE DIFFERENTIAL BETWEEN EXTERIOR AND INTERIOR FACERS MUST BE CONSIDERED WHEN APPLIES. 5. ALLOWABLE LOAD IS GOVERNED BY THE
LOWEST VALUE OF PANEL STIFFNESS, DEFLECTION LIMIT AND CONNECTION STRENGTH. CONNECTION PATTERN WAS # 14 SELF TAPPING FASTENER AT EACH RIB PER SUPPORT.
6. FOAM INSULATION FACTORS ARE BASED ON NOMINAL INITIAL K FACTOR OF 0.116 BTU.IN/HR.FT2°F TESTED AS PER ASTM C518-04 AT A MEAN TEMPERATURE OF 40°F (4°C)
PRODUCT PARAMETERS

Panel Thicknesses: 1.5” 2” 2.5” 3” 4” 6”


Insulating Values: (1) R=13 R=17 R=22 R=26 R=34 R=52
Panel Width: 39 3/8
Panel Length: From 8’ min to 50’ max length
Insulation Material: CFC free foamed in place isocyanurate with a nominal density
of 2.4 Ibs./cu ft.
Joint Configuration: Hi Rib overlapping joint
Metal Facings: Exterior: 26 ga, pre-painted galvanized and pre painted steel. 24 ga
and 22 ga available upon request. Please consult your sales
representative.
Interior: 26 ga, pre-painted galvanized steel. 24 ga and 22 ga
available upon request. Please consult your sales representative
Accessories: Fasteners, brake formed flashings to match panel, sealants
Coatings: Exterior: Siliconized polyester or PVDF polymer 70% kynar 500/ Hylar
5000 as a standard finish.
Interior: Siliconized polyester as a standard finish.

NOTES: (1) “R” VALUES ARE BASED ON K FACTOR OF 0.123 btu-in/h-sq ft-ºF.

1000 [39.37"] Coverage

333.33 [13.12"]
8 [0.31"]
42 [1.65"]

62.75 [2.47"] Typ

GT-1 System
The GT-1 system is an innovative crimped profiled sheet that can
be used to join the Hi Rib roof and wall panels at the eave detail or
can be used as a separate architectural element.

FEATURES AND BENEFITS


• GT-1
is available in pre-painted finish.

• The net coverage is 39.37”. Lengths are cut to order. The minimum
internal radius is 20”.

• The profile is available in 22, 24 & 26 gauge.

• Profile depth:1-5/8”.
Galvatherm Mesa
The Galvatherm Mesa panel is ideal for exterior industrial or com-
mercial walls. The 42” wide panel installs quickly and economical-
ly. Fasteners are concealed within the panel side joint and the
attractive “Mesa” profile breaks up the flat expanse of metal on
large-scale projects such as automobile plants.

02.

FEATURES AND BENEFITS


• The panel’s double tongue and groove joint is self aligning and weather
tight and allows for sealant application at either the interior or exterior
side of the panel joinery depending on the direction of vapor drive.

• The standard metal surface is 26 gauge galvanized steel with 20 year


warranted siliconized polyester or PVDF coatings.

• The panel arrives on site in one piece and requires a simple one step
installation helping to reduce construction time and costs.

w w w w
Thickness INSULATION FACTORS PANEL
(in) WEIGHT
R U (PSF)
SPAN (Ft)
ft2.h.ºF BTU
BTU ft2.h.ºF 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 15.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 15.0
2 17 0.058 2.13 69.8 57.1 48.2 41.7 34.8 27.1 68.9 56.8 48.3 42.1 37.2 30.2
2.5 22 0.046 2.23 64.8 54.6 47.2 41.6 35.4 28.2 64.2 54.5 47.4 41.9 37.6 31.3
3 26 0.039 2.35 71.8 60.6 52.3 46.0 41.0 35.1 28.5 70.9 60.2 52.3 46.2 41.4 37.6 31.7
4 34 0.029 2.51 84.5 71.2 61.4 54.0 48.1 43.4 39.5 36.2 27.6 82.9 70.3 61.0 53.9 48.3 43.7 39.9 36.4 31.0
5 43 0.023 2.72 95.9 80.8 69.6 61.1 54.4 49.0 44.6 40.9 37.8 35.1 93.7 79.4 68.8 60.7 54.3 49.2 44.9 41.3 38.3 34.0
6 52 0.019 2.93 106.2 89.5 77.1 67.7 60.2 54.2 49.3 45.2 41.7 38.4 103.6 87.7 75.9 67.0 59.9 54.2 49.4 45.5 42.1 39.2
NOTES: 1. BASED ON GALVATHERM 42 IN. WIDE WALL PANEL WITH 26 GA. EXTERIOR AND INTERIOR STEEL FACERS (MIN. FY= 37 KSI AS PER ASTM A653). 2. STEEL FACERS ARE
PREPAINTED GALVANIZED STEEL AS PER ASTM A653 GRADE 37 (FY= 37 KSI MIN). ELASTICITY MODULUS IS 29, 000 KSI. 3. LOAD TABLES WERE DERIVED FROM ASTM E72
STRUCTURAL TESTING. ALLOWABLE LOADS WERE OBTAINED WITH 2.5 BENDING SAFETY FACTOR 3.0 SHEAR SAFETY FACTOR, AND DEFLECTION LIMIT OF L/180. 4. THERMAL LOAD
EFFECT DUE TO TEMPERATURE DIFFERENTIAL BETWEEN EXTERIOR AND INTERIOR FACERS MUST BE CONSIDERED WHEN APPLIES. 5. ALLOWABLE LOAD IS GOVERNED BY THE
LOWEST VALUE OF BENDING STRENGTH, SHEAR STRENGTH AND DEFLECTION LIMIT. FOR ALLOWABLE LOAD GOVERNED BY CONNECTION, PLEASE CONTACT TO THE TECHNICAL
DEPARTMENT. 6. FOAM INSULATION FACTORS ARE BASED ON NOMINAL INITIAL K FACTOR OF 0.116 BTU/FT².H.°F TESTED AS PER ASTM C518-04 AT A MEAN TEMPERATURE OF
40°F (4°C).
1066.8 [42.00"] Coverage
59.27 [2.33"]

62.75 [2.47"] Typ

PRODUCT PARAMETERS

Panel Thicknesses: 2” 2.5” 3” 4” 5” 6”


Insulating Values: (1) R=17 R=22 R=26 R=34 R=43 R= 52
Panel Width: 42”
Panel Length: From 8’ min to 50’ max length.
Insulation Material: CFC free foamed in place isocyanurate with a nominal density of 2.4 Ibs/cu ft.
Joint Configuration: Concealed fastening off set tongue and groove.
Metal Facings: Exterior: 26 ga pre-painted galvanized steel. 22 and 24 ga available
Interior: 26 ga pre-painted galvanized steel and 26 ga- 304 type embossed stainless steel available upon
request. Please consult your sales representative. Note: 22 and 24 gauges available for interior and
exterior faces upon request. Please consult your sales representative
Accessories: Fasteners, concealed fastener clip, brake formed flashing to match panels, sealants.
Coatings: Exterior: PVDF polymer 70% Kynar 500/Hylar 5000 or Siliconized Polyester are standard finishes.
Interior: Siliconized polyester is the standard finish. PVC plastisol available upon request. Please consult
your sales representative.

NOTES: (1) “R” VALUES ARE BASED ON K FACTOR OF 0.123 btu-in/h-sq ft-ºF.
Galvatherm Shadowline
Galvatherm Shadowline profile panel is ideal for interior partition
walls or exterior building walls and soffits where a light vertical
accent line is preferred. This panel is a mirror image with both the
interior and exterior sides of the panel profiled with the same verti-
cal shadowline.

03.

FEATURES AND BENEFITS


• Foam insulation is applied to this panel as a self rising liquid thus creat-
ing a solid monolithic panel with no room for interstitial condensation.

• The composite engagement of the foam/metal bond generates an


extremely strong and well insulated panel that can meet long span
requirements as an exterior wall or as an interior partition.

• PVC coating (Plastisol) and 304 grade stainless steel in the liner is avail-
able for tough food processing wash down applications.

w w w w
Thickness INSULATION FACTORS PANEL
(in) WEIGHT
R U (PSF)
SPAN (Ft)
ft2.h.ºF BTU
BTU ft2.h.ºF 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 15.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 15.0
2 17 0.058 2.13 69.8 56.8 48.3 41.7 32.6 25.3 68.9 56.8 48.3 39.1 30.2 21.5
2.5 22 0.046 2.23 64.8 54.6 47.2 36.4 28.1 22.4 64.2 54.5 47.4 38.7 30.6 24.9
3 26 0.039 2.35 71.8 60.6 52.3 46.0 35.2 27.8 22.6 70.9 60.2 52.3 47.6 37.5 30.4 25.1
4 34 0.029 2.51 84.5 71.2 61.4 54.0 48.1 39.8 32.0 26.4 22.1 82.9 70.3 61.0 53.9 48.3 41.9 34.5 28.9 24.6
5 43 0.023 2.72 95.9 80.8 69.6 61.1 54.4 49.0 44.6 34.7 28.9 24.5 93.7 79.4 68.8 60.7 54.3 49.2 44.9 37.0 31.4 27.0
6 52 0.019 2.93 106.2 89.5 77.1 67.7 60.2 54.2 49.3 45.2 36.2 30.5 103.6 87.7 75.9 67.0 59.9 54.2 49.4 45.5 38.5 33.0
NOTES: 1. BASED ON GALVATHERM 42 IN. WIDE WALL PANEL WITH 26 GA. EXTERIOR AND INTERIOR STEEL FACERS (MIN. FY= 37 KSI AS PER ASTM A653) 2. STEEL FACERS ARE
PREPAINTED GALVANIZED STEEL AS PER ASTM A653 GRADE 37 (FY= 37 KSI MIN). ELASTICITY MODULUS IS 29, 000 KSI. 3. LOAD TABLES WERE DERIVED FROM ASTM E72
STRUCTURAL TESTING. ALLOWABLE LOADS WERE OBTAINED WITH 2.5 BENDING SAFETY FACTOR 3.0 SHEAR SAFETY FACTOR, AND DEFLECTION LIMIT OF L/180. 4. THERMAL LOAD
EFFECT DUE TO TEMPERATURE DIFFERENTIAL BETWEEN EXTERIOR AND INTERIOR FACERS MUST BE CONSIDERED WHEN APPLIES. 5. ALLOWABLE LOAD IS GOVERNED BY THE
LOWEST VALUE OF BENDING STRENGTH, SHEAR STRENGTH AND DEFLECTION LIMIT. FOR ALLOWABLE LOAD GOVERNED BY CONNECTION, PLEASE CONTACT TO THE TECHNICAL
DEPARTMENT. 6. FOAM INSULATION FACTORS ARE BASED ON NOMINAL INITIAL K FACTOR OF 0.116 BTU/FT².H.°F TESTED AS PER ASTM C518-04 AT A MEAN TEMPERATURE OF
40°F (4°C)
1066.8 [42.00"] Coverage

62.75 [2.47"] Typ

62.75 [2.47"] Typ

PRODUCT PARAMETERS

Panel Thicknesses: 2 2.5” 3” 4” 5” 6”


Insulating Values: (1) R=17 R=22 R=26 R=34 R=43 R=52
Panel Width: 42”
Panel Length: From 8’ min to 50’ max length.
Insulation Material: CFC free foamed in place isocyanurate with a nominal density of 2.4 lbs/cu ft.
Joint Configuration: Concealed fastening off set tongue and groove.
Metal Facings: Exterior: 26 ga pre-painted galvanized steel.
Interior: 26 ga pre-painted galvanized steel and 26 ga- 304 type embossed stainless steel available upon
request. Please consult your sales representative. Note: 22 and 24 gauges available for interior and exterior
faces upon request. Please consult your sales representative
Accessories: Fasteners, concealed fastener clip, brake formed flashing to match panels, sealants.
Coatings: Exterior: PVDF polymer 70% Kynar 500/Hylar 5000 or Siliconized Polyester are standard finishes.
Interior: Siliconized polyester is the standard finish. PVC plastisol available upon request. Please consult
your sales representative.

NOTES: (1) “R” VALUES ARE BASED ON K FACTOR OF 123 btu-in/h-sq ft-ºF.
Galvatherm Micro Rib
Galvatherm Micro Rib profile panel provides a high tech commer-
cial look with the savings and performance of a foam core panel.
The light striations in this panel connect and blend continuously
across the surface of the panel creating a subtle and pleasing visu-
al effect. Micro Rib is best suited for exterior building walls where
an upscale refined look is desired.

04.

FEATURES AND BENEFITS


• This panel is available in 24ga metal exterior faces only.

• Galvatherm panel can be installed vertically or horizontally to fit your


building design.

• With its concealed fastener design and high tech striated profile the
Galvatherm Micro Rib panel adds a high class touch to your building
while still keeping within your budget.

w w w w
Thickness INSULATION FACTORS PANEL
(in) WEIGHT
R U (PSF)
SPAN (Ft)
ft2.h. BTU
BTU ft2. 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 15.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 15.0
2 17 0.058 2.49 70.1 57.3 48.3 41.8 35.8 27.7 70.1 57.3 48.3 41.8 35.8 27.7
NOTES: 1. BASED ON GALVATHERM 42 IN. WIDE WALL PANEL WITH 26 GA. EXTERIOR AND INTERIOR STEEL FACERS (MIN. FY= 37 KSI AS PER ASTM A653). 2. STEEL FACERS ARE
PREPAINTED GALVANIZED STEEL AS PER ASTM A653 GRADE 37 (FY= 37 KSI MIN). ELASTICITY MODULUS IS 29, 000 KSI. 3. LOAD TABLES WERE DERIVED FROM ASTM E72
STRUCTURAL TESTING. ALLOWABLE LOADS WERE OBTAINED WITH 2.5 BENDING SAFETY FACTOR 3.0 SHEAR SAFETY FACTOR, AND DEFLECTION LIMIT OF L/180. 4. THERMAL LOAD
EFFECT DUE TO TEMPERATURE DIFFERENTIAL BETWEEN EXTERIOR AND INTERIOR FACERS MUST BE CONSIDERED WHEN APPLIES. 5. ALLOWABLE LOAD IS GOVERNED BY THE
LOWEST VALUE OF BENDING STRENGTH, SHEAR STRENGTH AND DEFLECTION LIMIT. FOR ALLOWABLE LOAD GOVERNED BY CONNECTION, PLEASE CONTACT TO THE TECHNICAL
DEPARTMENT. 6. FOAM INSULATION FACTORS ARE BASED ON NOMINAL INITIAL K FACTOR OF 0.116 BTU/FT².H.°F TESTED AS PER ASTM C518-04 AT A MEAN TEMPERATURE OF
40°F (4°C)
1066.8 [42.00"] Coverage

20.128 [0.79"]

62.75 [2.47"] Typ

PRODUCT PARAMETERS

Panel Thicknesses: 2”
Insulating Values: (1) R= 17
Panel Width: 42”
Panel Length: From 8’ min to 40’ max length.
Insulation Material: CFC free foamed in place isocyanurate with a nominal density of 2.4 lbs/cu ft.
Joint Configuration: Concealed fastening off set tongue and groove.
Metal Facings: Exterior: 24 ga pre-painted galvanized embossed steel.
Interior: 26 ga pre-painted galvanized steel
Accessories: Fasteners, concealed fastener clip, brake formed flashing to match panels, sealants.
Coatings: Exterior: PVDF polymer 70% Kynar 500/Hylar 5000 or Siliconized Polyester are standard finishes.
Interior: Siliconized polyester is the standard finish. PVC plastisol available upon request. Please consult
your sales representative.

NOTES: (1) “R” VALUES ARE BASED ON K FACTOR OF 123 btu-in/h-sq ft-ºF.
Galvatherm Heavy Stucco Wall
Galvatherm Heavy Stucco Wall panel is an exterior wall panel with
a unique embossing pattern that simulates the look of concrete
masonry stucco. It is ideal for projects where the performance and
economy of metal panel is needed but where aesthetics of the old
style stucco finishes are desired.

05.

FEATURES AND BENEFITS


• This panel is flush with no ribs or striations.

• The Heavy Stucco Wall panel can be applied vertically or horizontally.

• With its concealed fastener design and standard colors like sandstone
and surrey beige, the Galvatherm Heavy Stucco Wall has the look of
masonry stucco walls.

w w w w
Thickness INSULATION FACTORS PANEL
(in) WEIGHT
R U (PSF)
SPAN (Ft)
ft2.h. BTU
BTU ft2. 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 15.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 15.0
2 17 0.058 2.13 69.8 56.8 48.3 41.7 32.6 25.3 68.9 56.8 48.3 39.1 30.2 21.5
2.5 22 0.046 2.23 64.8 54.6 47.2 36.4 28.1 22.4 64.2 54.5 47.4 38.7 30.6 24.9
3 26 0.039 2.35 71.8 60.6 52.3 46.0 35.2 27.8 22.6 70.9 60.2 52.3 47.6 37.5 30.4 25.1
4 34 0.029 2.51 84.5 71.2 61.4 54.0 48.1 39.8 32.0 26.4 22.1 82.9 70.3 61.0 53.9 48.3 41.9 34.5 28.9 24.6
5 43 0.023 2.72 95.9 80.8 69.6 61.1 54.4 49.0 44.6 34.7 28.9 24.5 93.7 79.4 68.8 60.7 54.3 49.2 44.9 37.0 31.4 27.0
6 52 0.019 2.93 106.2 89.5 77.1 67.7 60.2 54.2 49.3 45.2 36.2 30.5 103.6 87.7 75.9 67.0 59.9 54.2 49.4 45.5 38.5 33.0
NOTES: 1. BASED ON GALVATHERM 42 IN. WIDE WALL PANEL WITH 26 GA. EXTERIOR AND INTERIOR STEEL FACERS (MIN. FY= 37 KSI AS PER ASTM A653). 2. STEEL FACERS ARE
PREPAINTED GALVANIZED STEEL AS PER ASTM A653 GRADE 37 (FY= 37 KSI MIN). ELASTICITY MODULUS IS 29, 000 KSI. 3. LOAD TABLES WERE DERIVED FROM ASTM E72
STRUCTURAL TESTING. ALLOWABLE LOADS WERE OBTAINED WITH 2.5 BENDING SAFETY FACTOR 3.0 SHEAR SAFETY FACTOR, AND DEFLECTION LIMIT OF L/180. 4. THERMAL LOAD
EFFECT DUE TO TEMPERATURE DIFFERENTIAL BETWEEN EXTERIOR AND INTERIOR FACERS MUST BE CONSIDERED WHEN APPLIES. 5. ALLOWABLE LOAD IS GOVERNED BY THE
LOWEST VALUE OF BENDING STRENGTH, SHEAR STRENGTH AND DEFLECTION LIMIT. FOR ALLOWABLE LOAD GOVERNED BY CONNECTION, PLEASE CONTACT TO THE TECHNICAL
DEPARTMENT. 6. FOAM INSULATION FACTORS ARE BASED ON NOMINAL INITIAL K FACTOR OF 0.116 BTU/FT².H.°F TESTED AS PER ASTM C518-04 AT A MEAN TEMPERATURE OF
40°F (4°C).
1066.8 [42.00"] Coverage

62.75 [2.47"] Typ

PRODUCT PARAMETERS

Panel Thicknesses: 2” 2.5” 3” 4” 5” 6”


Insulating Values: (1) R=17 R=22 R=26 R=34 R=43 R=52
Panel Width: 42”
Panel Length: From 8’ min to 40’ max length.
Insulation Material: CFC free foamed in place isocyanurate with a nominal density of 2.4 lbs/cu ft.
Joint Configuration: Off set tongue and groove.
Metal Facings: Exterior: 26 ga pre-painted galvanized steel.
Interior: 26 ga pre-painted galvanized steel and 26 ga- 304 type embossed stainless steel available upon
request. Please consult your sales representative.
Accessories: Fasteners, concealed fastener clip, brake formed flashing to match panels, sealants.
Coatings: Exterior: PVDF polymer 70% Kynar 500/Hylar 5000 or Siliconized Polyester are standard finishes.
Interior: Siliconized polyester is the standard finish. PVC plastisol available upon request. Please consult
your sales representative.

NOTES: (1) “R” VALUES ARE BASED ON K FACTOR OF 123 btu-in/h-sq ft-ºF.
CERTIFICATIONS AND APPROVALS
In addition to our detailed in-house testing programs, Galvamet’s
products have been tested by accredited independent laboratories
and have obtained third party certification for listing and classification
in the following agencies and laboratories:

• FM approval
• UnderwritersLaboratories Inc.
• UnderwritersLaboratories of Canada
• Southwest Research Institute

MEMBERSHIPS

We take pride in participating as good citizens in the industries we


serve and are members in good standing of the following organiza-
tions:

• National Roofing Contractors Association


• International Association for Cold Storage Construction.
• International Association of Refrigerated Warehouses
www.galvamet.com

Contact Information
1717 McCall Drive
Shelbyville, IN 46176
1-866-425-8638

You might also like