Professional Documents
Culture Documents
This protocol is applicable for all sites where a TAC‐3000 RANGE LIMITING DEVICE is
installed and requires to be BYPASSED for operational or maintenance purposes. It is the
responsibility of the crane supervisor to manage this document as well as the “BY‐PASS”
key and review the scope of work with all involved prior to issuing this authorization.
The TAC-3000 RANGE LIMITING DEVICE “BY-PASS KEY” is provided to allow the
below identified crane to be “BYPASSED” to allow for the following operations:
*Ensure appropriate alternative protection means are in place and all applicable
Rules and Regulations are respected.
Task Description:
In order to turn the System in “BYPASS”, a key must be provided to the operator
by site Management. The key requires to be inserted in the monitor in the cab
and turned ¼ of a turn to the right. A “BYPASS” status will now be indicated on
the top left corner of the screen. Audible and visual warnings will remain active
Page 1 of 2
but the system will not take any action to slow or stop the crane while in the
“BYPASS” mode.
By default, the crane will return to “NORMAL” state within 60 minutes even
though the key may still be physically in the “BYPASS” position. This means that
the operator requires to turn the system back to “NORMAL” by turning the key to
its original position and then turn it ¼ of a turn to the right again to resume
“BYPASS” mode if required.
BYPASS KEY #:
Page 2 of 2