You are on page 1of 1

INSULATION THICKNESS CALCULATION AROUND DEBUTANIZER REBOILER

OD pipe* Cal. Ins. Thick. Actual Ins. Thick. Ins. Thick. (as
No. Line No. K (cm) K (mm) OD (mm)
(mm) (mm) (mm) per PID) (mm)
Debutanizer Reboiler-Vapor Outlet
1 8"-PG-82098-A01B-H 103.0 1030.0 327.9 219.08 54.4 55 75
2 6"-PG-82098-A01B-H 87.5 875.0 278.5 168.28 55.1 55 75
Debutanizer Reboiler-Liquid Inlet
3 8"-PL-82101-A01B-H 103.0 1030.0 327.9 219.08 54.4 55 65
4 4"-PL-82101-A01B-H 70.5 705.0 224.4 114.30 55.1 55 65
Debutanizer Reboiler-Liquid Outlet
5 2"-PL-82102-A01B-H 53.0 530.0 168.7 60.33 54.2 55 50
Note : *) Data was taken form Pipe Data Pro. 7 Simulator