Professional Documents
Culture Documents
KALKULASI
DE-ETANIZER REBOILER
E-1401
0 08/01/14 Issued for Construction KUN AGS
B 25/12/13 Issued for Approval KUN AGS
A 21/11/13 Issued for Comment KUN AGS
BY CHK APPR CHK APPR CHK APPR
REV. DATE DESCRIPTION
HOKASA PMC ESDM
Rev.
B
APPR
ESDM
1. TUJUAN
Kalkulasi ini dibuat untuk menentukan dimensi/ukuran De-etanizer Reboiler E-1401
2. BASIS
Tube Shell
Masuk Keluar Masuk Keluar
Fluida Therminol 55 Hydrocarbon
Laju alir Lb/h 10159.1 10159.1 7715.4 7715.4
Tekanan Psia 89.7 87.7 441.7 439.7
Suhu °F 400 315 198 210
3. METODOLOGI
Kalkulasi ini menggunakan software HTRI versi 5.
4. KESIMPULAN
Tipe Heat Exchanger : Shell and Tube Horisontal type BKT
Ukuran : 11.75" - 23" ID x 10'-0" L B
Jumlah Tube : 75
Beban : 0.4991 MMBtu/h
Luas Area : 144.378 Ft2
5. REFERENSI
Proses Basis Desain
Proses Simulasi
6. LAMPIRAN
Lampiran 1 Laporan Kalkulasi
LAMPIRAN 1
LAPORAN KALKULASI
hell
Keluar
carbon
7715.4
439.7 B
210
Output Summary Page 1
Released to the following HTRI Member Company:
PT. Hokasa Mandiri
HP
Xist E Ver. 5.00 12/25/2013 22:30 US Units
10.000 ft
Exchanger Fluid Volumes
Approximate shellside (ft3) 19.158
Approximate tubeside (ft3) 2.943
Shell Construction Information
TEMA shell type BKT Shell ID (inch) 11.7500
Shells Series 1 Parallel 1 Total area (ft2) 147.262
Passes Shell 1 Tube 2 Eff. area (ft2/shell) 144.378
Shell orientation angle (deg) 0.00 Kettle ID (inch) 23.0000
Impingement present No
Pairs seal strips 0 Passlane seal rods (inch) 0.0000 No. 0
Shell expansion joint No Rear head support plate No
Weight estimation Wet/Dry/Bundle 3502.9 / 2124.2 / 504.41 (lb/shell)
Baffle Information
Type Support Baffle cut (% dia)
Crosspasses/shellpass 1 No. (Pct Area) (inch) to C.L
Central spacing (inch) 39.2167 1
Inlet spacing (inch) 0.0000 2
Outlet spacing (inch) 0.0000 Support plates/baffle space 2
Baffle thickness (inch) 0.2500
Tube Information
Tube type Plain Tubecount per shell 75
Overall length (ft) 10.000 Pct tubes removed (none)
Effective length (ft) 9.804 Outside diameter (inch) 0.7500
Total tubesheet (inch) 2.3500 Wall thickness (inch) 0.0830
Area ratio (out/in) 1.2842 Pitch (inch) 1.0000 Ratio 1.3333
Tube metal tainless steel (17 Cr, 12 Ni) Tube pattern (deg) 30
Job No.
Customer ESDM Reference No.
Address Proposal No.
Plant Location JATA-SUMATRA SELATAN Date 12/25/2013 Rev B
Service of Unit DE-ETHANIZER REBOILER Item No. E-1403
Size 11.75 - 23.00 x 120.00 inch Type BKT Horz. Connected In 1 Parallel 1 Series
Surf/Unit (Gross/Eff) 147.26 / 144.38 ft2 Shell/Unit 1 Surf/Shell (Gross/Eff) 147.26 / 144.38 ft2
PERFORMANCE OF ONE UNIT
Fluid Allocation Shell Side Tube Side
Fluid Name Hydrocarbon Therminol 55
Fluid Quantity, Total lb/hr 7715.40 10159.1
Vapor (In/Out) 5587.75
Liquid 7715.40 2127.65 10159.1 10159.1
Steam
Water
Noncondensables
Temperature (In/Out) F 198.39 209.70 400.00 315.00
Specific Gravity 0.3924 0.3945 0.7866 0.8217
Viscosity cP 0.0604 0.6580 V/L 0.0598 0.6385 1.0145
Molecular Weight, Vapor
Molecular Weight, Noncondensables
Specific Heat Btu/lb-F 1.0965 0.7849 V/L 1.073 0.5940 0.5618
Thermal Conductivity Btu/hr-ft-F 0.0337 0.0173 V/L 0.033 0.0644 0.0684
Latent Heat Btu/lb 74.2003 73.4991
Inlet Pressure psia 441.697 84.696
Velocity ft/sec 0.33 0.84
Pressure Drop, Allow/Calc psi 0.027 10.000 0.133
Fouling Resistance (min) ft2-hr-F/Btu 0.00100 0.00200
Heat Exchanged Btu/hr 499052 MTD (Corrected) 145.5 F
Transfer Rate, Service 23.76 Btu/ft2-hr-F Clean 32.45 Btu/ft2-hr-F Actual 29.09 Btu/ft2-hr-F
CONSTRUCTION OF ONE SHELL Sketch (Bundle/Nozzle Orientation)
Shell Side Tube Side
Design/Test Pressure psig 300.000 / 400.000 /
Design Temperature F 500.00 150.00 11.7500 inch
23.0000 inch