You are on page 1of 4

4

Project Unit Doc Code Serial Rev. Page

S646 140 PDS V-023 25 0 2/4


1/3
TECHNIP KT INDIA

OWNER : NAGARJUNA OIL CORPORATION LTD .


PMC : CB&I, LUMMUS
FEED CONTRACTOR : TECHNIP KT INDIA LTD.
The present document or drawing is property of TECHNIP KT INDIA LTD. and shall not, under any circumstances, be totally or partially, directly or indirectly, transferred, reproduced, copied, disclosed or

PROJECT : FEED FOR DIESEL HYDRODESULFURIZATION UNIT


UNIT : DIESEL HYDRODESULFURIZATION UNIT
PMC DOCUMENT NO : CK-140-PR-30-0053
used, without its prior written consent, for any purpose and in any way other than that for which it is specifically fu rnished or outside the extent of the agreed upon right of use.

PROCESS DATA SHEET


FOR
FLARE K.O. DRUM
(TAG NO: 140-V-023)

0 04- 06- 2009 APPROVED FOR DESIGN RCD NHB TT SLSK


REV. DATE STATUS PREPARED BY REVIEWED BY APPROVED BY PM
DOCUMENT REVISIONS
Sections changed in last revision are identified by a line in the right margin
PROCESS DATA SHEET
Project N° - Unit Doc. type Equipment N° Serial N° Rev. index

S646 - 140 PDS V-023 25 0


TECHNIP KT INDIA LTD. PMC Doc No,

CK-140-PR-30-0053
CLIENT NOCL Rev. Date Made by Checked by Page
PMC CB&I LUMMUS 0 4-Jun-09 RCD NHB
Revision

LOCATION CUDDALORE, TAMILNADU


INDIA
HORIZONTAL DRUM 3/4
2/3
UNIT Diesel Hydrodesulfurization
Unit
1 ITEM 140-V-023
2 SERVICE Flare K.O. Drum SKETCH:
3 OPERATING PROCESS DESIGN
4 Pressure barg barg

LT1

LT1
Vortex breaker
5 0.25 3.5/FV
6 (Note-5)

Min.

Min.
7 Temperature °C °C
TL
8 40-57 250/120

B
9

OL
10 MDMT 18

LG
11 SHELL/ENDS STEAM COIL

LG
D
12 Materials HIC Resistant KCS (PWHT, Note-6) KCS

13 Corrosion allow. 3 mm 3 mm

150
R
14 Head type Elliptical 2:1

T
15 Fluid : HYDROCARBONS 150

16 Density at T : 854.2 to 990.0 kg/m³


17 Insulation NO
Lining NO

NHLL 2100

LAH 2000

NLLL 150
18

LAL 250
9000
19 Lower TL elevation above ground = (4000 MIN)
20 Notes :
21 See Page 3/3
22
PI

LT2
23

LT2
24

(4000 min)
25

26
A

27 NOZZLE DATA
MH
28 REF. No Ø Rating SERVICE TL
29 A 1 20" 150# Gas Inlet
Min.

30 B 1 20" 150# Gas Outlet


31 OL 1 4" 150# Pump Nozzles
UC

32 PI 1 2" 150# Pressure Gauge


S1
S2

33 LT1 2 2" 150# Level instrument 3000 I.D.


34 LT2 2 2" 150# Level instrument
35 T 1 2" 150# Temperature Instr
36 MH 1 24" 150# Manhole
37 UC 1 2" 150# Utility Connection Special service = Yes
38 V 1 2" 150# Vent
39 LG 2 2" 150# Level Gauge Hydrogen service = No
40 Sour service = Yes
41 Amine service = Yes
42 Caustic service = No
43 S1 1 2" 150# Steam Coil Inlet

44 All dimensions are in mm


45 S2 1 2" 150# Steam Coil Outlet

46 D 1 2" 150# Drain

47 R 1 2" 150# Min. Flow Recirculation

48
\\Kt001sf0005\s646\Process\5.0 Coded Document\PDS\2.0 Vessel\140-V-023_Flare KOD\Rev 0\[Copy of S646-140-PDS-V023-25-REV 0.xls]PD017A12 PD017A12
Property of Technip KT India Ltd. To be returned upon request and used only in reference to contract or proposals of this company. Reproduction of
this print or unauthorised use of patented or patentable features disclosed hereon is prohibited.
PROCESS DATA SHEET
Project N° - Unit Doc. type Equipment N° Serial N° Rev. index

S646 - 140 PDS V-023 25 0


TECHNIP KT INDIA LTD. PMC Doc No,

CK-140-PR-30-0053
CLIENT NOCL Rev. Date Made by Checked by Page
PMC CB&I LUMMUS 0 4-Jun-09 RCD NHB
Revision

LOCATION CUDDALORE, TAMILNADU


HORIZONTAL DRUM 3/3
INDIA 4/4
UNIT Diesel Hydrodesulfurization
Unit
1

2 Notes :
3 1) Flare KOD is designed as per API-521.
4 2) Vessel is designed to remove 600 micron particle size.
5 Governing Vapor relief case : Emergency Depressurisation
6 3) Vessel is designed for 20 min liquid hold up for Largest Liquid Relief Case.
7 4) Elevation of Level Instrument Nozzle to be decided by DEC Instrumentation.
8 5) Vessel shall be designed for Steam Out Condition : 0 barg ,120 C.
9 6) Wet H2S Service.
10 7) Deleted.

11 8) Steam coil length is 110 m.

12 9) Refer P&ID No. CE-140-PR-15-0038.

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

43

44

45

46

47

48
\\Kt001sf0005\s646\Process\5.0 Coded Document\PDS\2.0 Vessel\140-V-023_Flare KOD\Rev 0\[Copy of S646-140-PDS-V023-25-REV 0.xls]PD017A12 (2) PD017A12
Property of Technip KT India Ltd. To be returned upon request and used only in reference to contract or proposals of this company.
Reproduction of this print or unauthorised use of patented or patentable features disclosed hereon is prohibited.