DE-BUTANIZER ACCUMULATOR
CALCULATION
V - 1403
2. DESIGN METHOD
The calculation according API 12 J, Specification for Oil and Gas Separator.
Calculated sufficient cross sectional area for gas phase to release or separate liquid.
Calculated sufficient liquid retention time for instrumetation spacing.
3. REFERENCES
API 12 J, Specification for Oil and Gas Separator
GPSA, Engineering Data Book, 11th Edition, 1998
Process Design Basis
Process Simulation
4. EQUATION
Mass rate fluid total mass rate
Volume rate m
Mass density
fluid total vol. rate
l g
Vc K . Vc : maximum allowable velocity, ft/s
g
Stoke's Law :
Intermediate Law :
Newton's Law :
5. CALCULATION
BASIS
Safety Factor 10 %
Gas volume rate 0.0 ft3/hr
Liquid volume rate 124.08 ft3/hr 2.068082
Mixed inlet density 30.03 lb/ft3
Nozzle
Note
Note 1 K value is multiplied by adjustment factor based on GPSA.
(for horizontal separator, take K = 0.45 and for 180 psig, the adjustment factor is 0.89)
Separator Dimensioning and Instrumentation Spacing
Liquid Levels (water section) Liquid area Total Volume Delta Volume Hold Up Time
Reference Level, in ft2 ft3 ft3 Min
Bottom 0 0.00 0.00 0.00 0.00
LLLL 6 0.77 4.65 4.65 2.25
LLL 12 2.06 12.38 7.73 3.74
NLL 18 3.53 21.21 8.83 4.27
HLL 24 5.01 30.04 8.83 4.27
HHLL 30 6.29 37.77 7.73 3.74
Liquid Residence Time 10.25
Liquid hold up 16.56 ft3 from LLLL - NLL > liquid vol rate OK
Vapor area 0.77 ft2 Vapor Area > Amin OK
Vapor segment 6.00 in
ga
s
Gravity Settling
ar Calculations
ea
Pemisahan
Dispersed phase Liquid
Continuous phase Gas
Droplet diameter to settle 100 micron
0.0003 ft
Dispersed phase density (droplet) 30.03 lb/ft3
Continuous phase density 1.89 lb/ft3
Continuous phase viscosity 0.01 cP
Acceleration due to gravity 32.2 ft/s2
Gas Area
6 in
D
HHLL 30 in 36 in
HLL 24 in
NLL 18 in
LLL 12 in
LLLL 6 in
Length 6.0 ft