You are on page 1of 15
APLICACION LA PRESENTE NORMA SE APLICA EN EL DISENO DE REDES AEREAS Y SUBTERRANEAS DEL SUBSISTEMA DE DISTRIGUCION PRIMARIA OE MEDIA TENSION Y BAJA TENSION EN EL AREA DE CONCESION DE LUZ DEL SUR SAA JIPOS DE CABLES Y CONDUCTORES LOS TIPOS DE CABLES Y CONDUCTORES CONSIDERADOS EN LA PRESENTE NORMA SON LOS SIGUIENTES: = Nr CABLE DE ENERGIA TIPO NYY DE BAJA TENSION (CORRE) = Nay CABLE DE ENERGIA TIPO NAYY DE BAJA TENSION. (ALUMINIO) — NKY CABLE DE ENERGIA TRIPOLAR TIPO NKY DE BAIA TENSION ~ cans CABLE AUTOPORTANTE DE COBRE DE 8.7. CON MENSAJERO DE ACERO. = caus CABLE AUTOPORTANTE DE ALUMINIO DE 8.7. CON MENSAJERO DE ACERO. | = oP CONDUCTOR CABLEADO PROTEGIDO A LA INTEMPERIE DE BAJA TENSION. aL CONDUCTOR DE ALEACION DE ALUMINIO DESNUDO DE BAIA TENSION = NKy CABLE DE ENERGIA TRIOLAR TIPO NKY DE MEDIA TENSION. - wsy ‘CABLE DE ENERGIA TIPO NYSY UNIPOLAR DE MEDIA TENSION. ~ Naxsy CABLE DE ENERGIA TIPO N2XSY UNIPOLAR DE COBRE MEDIA TENSION. ~ NAQxsy CABLE DE ENERGIA TIPO NA2XSY UNIPOLAR DE ALUMINIO MEDIA TENSION — N2xS2Y-S : CABLE AUTOPORTANTE DE COBRE OE MEDIA TENSION — NAKS2Y-S : CABLE AUTOPORTANTE DE ALUMINIO DE MEDIA TENSION. IK -m CONDUCTOR CABLEADO DESNUDO DE ALEACION OE ALUMINIO DE MT. — cu CONDUCTOR CABLEADO DESNUDO DE COBRE DE MT. = sax CONDUCTOR CABLEADO DE ALEACION DE ALUMINIO PROTEGIDO DE Mz. PARAMETROS DE CABLES Y CONDUCTORES LOS PARAMETROS CONSIDERADOS EN LA PRESENTE NORMA SON LOS SIGUIENTES: I} PARAMETROS ELECTRICOS = RESISTENCIA ELECTRICA A 20 ( Re ). — RESISTENCIA ELECTRICA A LA TEMPERATURA DE TRABAJO DEL CONDUCTOR ( R ). REACTANCIA INDUCTIVA ( X ). — REACTANCIA CAPACITIVA ( Xe ). 9) CAPACIDAD_DE_CORRIENTE S| I — CAPACIDAD DE CORRIENTE A LA TEMPERATURA MAXIMA DE OPERACION ei = CAPACIDAD DE CORRIENTE A LA TEMPERATURA DE EMERGENCIA. 2) a) PARAMETROS MECANICOS ~ PESO. = CARGA OE ROTURA | — GOEFICIENTE DE DILATACION LINEAL A 20°C. AI = MODULO DE ELASTICIAD LINEAL. PARAMETROS DE CABLES Y CONDUCTORES DE BT Y MT @ uz vex sur sr, NORMA DE DISTRIBUCION RD-3-010 9, 1) BAJA TENSION — 0.22 CABLES SUBTERRANEOS CONDICIONES DE INSTALAGION: — TEMPERATURA AMBIENTE (SUELO) — TEMPERATURA OE EMERGENCA = PROFUNDIDAD DE INSTALACION = TIPO DE INSTALACION kv. — TEMPERATURA MAXIMA, OE OPERACION — RESISTIIDAD TERWICA DEL TERRENO PARAMETROS ELECTRICOS Y CAPACIDAD DE CORRIENTE 25°C, + 80 °C, NYY ¥ NKY. 70 °C, NAVY 90 °C, NYY. NAYY = CANTIDAD DE CABLES EN UNA MISHA ZANJA ‘3 UNIPOLARES EN PARALELO, NYY. NAYY 1 TRIPOLAR, NAY. OIRECTAMENTE ENTERRADOS. = Rs RESISTENCIA ELECTRICA A B0'C. = X 5 REACTANCIA INDUCTIVA TRIFASICA I] SEPARACION ENTRE CABLES JUNTOS EN PARALELO, NYY. NAYY TABLAN'1 PARAMETROS ELECTRICOS DE CABLES SUBTERRANEOS DE BT. PO ‘SECCION num. Rao R x (mmm) Fases | (onm/am) | (Orm/Km) | (Ohm/Kmn) 6 3 3.0800 | 38060 | 0.1640 10 3 vasoo | 22620 | 0.1820 16 3 1.1500 yazio | 0.1430 38 3 oszao | o6aao | 0.1520 nvr 70 3 2680 | 0.3310 | 0.1240 185 3 0.0991 0.1220 | 0.1180 500 3 025s | 0.0320 | 0.1130 10 3 1.8300 2.2620 | 0.0960 25 3 07270 | 0.8984 | 0.0896 x 3 3 osza0 | 04a | 0.0870 I |r I | 50 3 03670 | 04783 | 0.0853 Ha Ney 70 3 o2eao | ossio | 0.0880 i 95, 3 03930 | 0.2305 | 0.0821 150 3 onz40 | 0.1532 | 0.0800 || 240 3 oo7ss | 0.0932 | 0.0795 eI nova PARAMETROS DE CABLES Y CONDUCTORES DE BT Y MT iuz oe sun sal NORMA DE DISTRIBUCION RD-3-010, 2 0 15| TABLA NI PARAMETROS ELECTRICOS DE CABLES SUSTERRANEOS DE 8.1. ( NAYY ) P| Goma) | fasts | conmruen | conmramy | (onm/Ken) 70 3 | 308 se2_| oz 16 3] 191 2.37 | 0,145 25 3 12 1.49 | _on42 aw 70 3 | osa3 | 0.551 | 0.28 95 3 | os2 | 0.308 | 0.126 Ky 720 30253 | 0515 | 0.125 785 3s [one | 0.206 | 0,121 300 3 | 070 | 0125 | 0.120 500 3 | 00608 | 00771 | 0.116 no Rt RESISTENCIA ELECTRICA A 70°C. X + REACTANCIA INDUCTIVA TRIFASICA, 2008 T I ENERO, PARAMETROS DE CABLES Y CONDUCTORES DE BT Y MT @iuz oer sun sal NORMA DE DISTRIBUCION RO-3-010,,. ,, T ENERO 2008. JONID=Z00T TABLA. N2 CAPACIOAD DE CORRIENTE DE CABLES SUBTERRANEOS DE Teo | secciow [eAPACI0AD OF conRENTE (4) Goma) [now ©) | EWERGENCA 36 134 18 wer 70 183 210 120 263 287 185 a3 364 300 “1 83 300 377 e2e 16 76 83 70 768) 185 avy 35 203 222 785 294 32 300 385 #20 25 108 128 35 133 156 30 158 15 ne 70 194 227 2% 229 208 j 120 200 304 ! 150 201 340 H 1285 328 se (*) CAPACIDAD DE GORRIENTE NOMINAL A LA TEMPERATURA MAXIMA DE OPERACION. — LOS VALORES CORRESPOND: ‘A TIPOS DE CARGA CON FACTOR DE CARGA << 0.75, Poor Fech PARAMETROS DE CABLES Y CONDUCTORES DE BT Y MT cuz oe. sun sr] NORMA DE DISTRIBUCION RD-3-010 “4 0E 15 ENERO 2008. ONIO=2O0T CONDUCTORES Y CABLES AEREOS CONDICIONES DF INSTALAGION: = TEMPERATURA AMBIENTE 30 'c. TEMPERATURA MAXIMA DE OPERACION 60 °C, cri Y AL 90 "°C, CAI-S ¥ CAALS, TEMPERATURA DE EMERGENCIA 75°C, CPI Y AL 130 °C, CAMS ¥ CAMS, 2 km/h = VELOCIDAD EL VIENTO TABLA.NS PARAMETROS ELECTRICOS DE CABLES Y CONDUCTORES AEREOS DE aT. me) | __ £483 | Conm/km) | COnm/em) | (Onm/Krm) caai-s 35 3 oaseo | 09720 | 0.1058 3 3 2300_| 25707 _| 04269 10 3 ve700 | _21850_| _oies 8 3 vao0o | 1.6139 | 0.4086 16 3 va700_| 1.3490 | 04008 21 3 os20 | 10168 | 0.3908 25 3 oreo | ows | _0.3es0 on 3 3 oss | oeiso | ovis 20 3 03050 | 04s | 0.3537 7 3 02730 | osra7 | 0.8309 Nota — R : RESISTENCIA ELECTRICA A 50°C, CAS ¥ CANS. RESISTENCIA ELECTRICA A 60'C, CPI Y AL. =X: REACTANGIA INOUCTVA TRIFASICA, CALCULADO PARA UN SISTEMA BALANCEADO OE PARAMETROS DE CABLES Y CONDUCTORES DE BT Y MT @uuz vex sur 5A NORMA DE DISTRIBUCION RD-3-010 | TABLAS CAPACIDAD DE CORRIENTE DE CABLES Y CONDUCTORES AEREOS DE 7, “SECCION [.CAPAGIOAD DE CORRIENTE (A) (rmm2) [Nowa (*) | EMERGENCIA 35 233 50 283 70 365 16 106 25 138 3 16 2 2 3 (*) CAPACIDAD DE CORRIENTE NOMINAL A LA TEMPERATURA MAXIMA OE OPERACION. ENERO 2008. JUNID=2007 PARAMETROS DE CABLES Y CONDUCTORES DE BT Y MT @iuz oe. sun sn] NORMA DE DISTRIBUCION RO-3-010 2) MEDIA TENSION — 10 KV. CABLES SUBTERRANEOS “CONDICIONES DE INSTALAGION: = TEWPERATURA AMBIENTE (SUELO) 125. = TEWPERATURA MAXIMA DE OPERACION 70 “6, Ney. 90 °C, NYSY, NOXSY y NADXSY = TENPERATURA DE EMERGENCIA 90 °C, Nex. 130 °C, NYSY, NaXSY y NADXSY = RESISHVOAD TERMICA DEL TERRENO 150 “C-em/W = PROFUNOIDAD DE INSTALACION 1.00 m = CATIOAD OF CABLES EN UNA NISMA ZANJA : 3 UNIPOLARES EN PARALELO, NYSY, NOXSY y NAZKSY = TRO DE INSTALACION OIRECTAMENTE. ENTERRADOS. = SEPARAGION ENTRE CABLES 70. mm. EN PARALELO, NYSY, NOXSY y NAQKSY | ABA 108 PARAMETROS ELECTRICOS OE CABLES SUBTERRANEOS DE MI. ~ 10 KV. eo] seccon | um ro ® x xe (omm2)_ | Fuses | Conm/km) | Comm) | Commi) | COnm/km) 240 3 o.075¢ | aaeso | 0.0030 | aas7aevos 16 3 1500 | ise | 0.2030 | r20reev0e wry 35 3 05200 | owes | o08e | 147256004 70 3 0.2680 | 03417 | ore9 | s.28seevos 16 3 7.1500 | 14864 | 0.2438 | 1.2018rv04 S| Ss i Y Nova a = Rs RESISTENCIA ELECTRICA A 70°, Nix. RESISTENGIA ELECTRICA A 90°C, NYSY, NZXSY y NA2XSY PARAMETROS DE CABLES Y CONDUCTORES DE BT Y MT iy | cuz er sur sm| NORMA DE DISTRIBUCION RD-3-010,. ENERO “2008. JONIU=200T TARLANS PARAMETROS ELECTRICOS DE CABLES SUBTERRANEOS DE MT. — 10 KV, neo seocion | num, Rw R x xe (roma) Fases | (onm/km) | (Orm/Km) | (ohm/Km) | (Ohm/Ken) 50 0,641 | 0,822 [0,199 | ra7ascroe 95 0.320 | 0,410 [0,182 | s.2esezvo4 Naaxsy 120 3 0,253 | 0,324 [0,176 | tosseeroe 185) 0,164 | 0,210 |o,165 | 7ee01e+03 ‘400 0,078 [ 0,100 [0,151 __| 78a01E+03 JAANE CAPACIDAD DE CORRIENTE DE CABLES SUBTERRANEOS DE MT. - 10 Kv. TO. SECCION | CAPACIDAD DE CORRIENTE (A) (eom2) | Nominal (=) [_ EMERGENGIA NK 70 189 227 95 223 268 120 252 302 240 ‘375 450 16 7 108 nrsr 35 140 168 70 200 240 16 10 13 2 142 169 3 168 202 50 146 174 95 22. 252 Naas 120 242 208 185 308. 364 400) 459 546 (*) CAPACIOAD DE CORRIENTE NOMINAL A LA TEMPERATURA MAXIMA DE OPERACION. NoTA — LOS VALORES CORRESPONDEN A TIPOS OE CARGA CON FACTOR DE CARGA < 0.75. PARAMETROS DE CABLES Y CONDUCTORES DE BT Y MT oar Fechar @euz oer sur sr NORMA DE DISTRIBUCION RD-3-010 @ DE 15 CONDUCTORES Y CABLES AEREOS CONDICIONES DE INSTALAGION: — TEMPERATURA AMBIENTE = TEMPERATURA DE EMERGENCIA = SEPARACION ENTRE CONDUCTORES 30°. 90 °C, N2xS2Y-S Y NAZKSAZY-S. 80 °C, SAX, 75°C, aAY CU, 130 "0, N2XSZY—S Y NAZKSARY-S. 2 km/h SEGUN TIPO DE ESTRUCTURA, AA Y CU. CONDUCTORES TRENZADOS, N2XS2Y-S Y 9 DE 15 naaxsAar-s. aaa sc? PARAMETROS ELECTRIGOS OE CABLES ¥ CONDUCTORES AEROS OF MIT. — 10 Kv oom) |_Fa8es | conmreem | conmenen | Gorman | (onmrem 70 3 osi00 | osese | owner | 2seseevos 120 3 02820 | o.saze | 0.3035 | aanedevos 125 3 e207 | 0.soe2 | 0.3011 | 2sse0eros an tes 3 ones | 02210 | 0.3767 | 2206sev0s 70 3 e120 | 0.1024 | 0.3667 | 2.2308e+08 2 3 21900 | 25248 | 04939 | s.0r00ev05 3 3 1a750 | 1ses1 | oa7e2 | 2owosevos . 1 3 1.1700 | see | oeo7 | 2e01€+08 21 3 oeeas | 00000 | 0.4800 | 2ez0se+0s 28 3 oro | oasaz | 0.4820 | 2ezsse+os IS | is i 70 3 o27s0 | sta? | oatse | 2eseee+os Fy 120 3 onse0| 017068 | 03828 | 20s26E+0s 8 2 2.1000 | 28248 | 0.4765 | 30z20ev0s 16 2 1.1700 | 3488 | 0623 | 20350808 PARAMETROS DE CABLES Y CONDUCTORES DE BT Y MT 39)"|@euz oer sun sA| NORMA DE DISTRIBUCION RD-3-010 aga 107 PARAMETROS ELECTRICOS DE CABLES Y CONDUCTORES AEREOS OE MT. — 10 KV. Ql Po] SECcION | Now Ra ® x ve rma) | FASES | Conm/um) | Cohm/uem) | (Onm/Km) | (Ohm /Krm) Nazxsa2y—s 120) 3 02530 | 027036 | oaee | 1.14696+08 sx 120) 3 oee0 | 0502 | oa00s | e.sea7eros = R-: RESISTENCIA ELECTRICA A 50'C, N2XS2Y-5 Y NA2XSA2Y-5, RESISTENCIA ELECTRICA A 60°C, AA Y CU. = UA REACTANCIA INDUCTIVA TRIFASICA SE HA CALCULADO PARA UN SISTEMA TRFASICO DE TRES HILOS, PARA EL SISTEMA DE CUATRO HILOS CONSIDERAR DE 5% A 10% MAS. = Us REACTANCIA INDUCTIVA TRIFASICA PARA CONDUCTORES DE AA Y CU, HA SIDO OBTENIDA PARA LUNA DISPOSICION VERTICAL DE CONDUCTORES, SEPARADOS 800 mm. le TABLA.1¢8 CAPACIOAD DE CORRIENTE OE CABLES Y CONDUCTORES AEREOS DE M.T. ~ 10 KV. po] Seccion | CAPAGIDAD DE CORRENTE (A) (eom2) | NOMINAL () | EMERGENGIA 3 730) 156 EJ 739 166 | m 79 201 250 125 235 366 es 05, 288, 3 7a 35 16 a 138 | 25 134 Tae ou 35 82 225, 2 200 240 a) 7 266 37 3 EI 7 275 3a A 120) a6 285; 2) 3 725 220 zi iE naxsav-s [0 225 268 a 70. 280 333 70. 226 a NARXSABY-S | Tag 320 3a LJ as a0 228 | a5 ai 387 1 Nota () CAPACIOAD DE CORRIENTE NOMINAL A LA TEMPERATURA MAKIMNA DE OPERACION. PARAMETROS DE CABLES Y CONDUCTORES DE BT Y MT @Quuz DEL SURS.A| NORMA DE DISTRIBUCION RD-3-010 |, ENERO 2008 JONIO=200 3) MEDIA TENSION — 22.9 kv. CABLES SUBTERRANEOS CONDICIONES DE INSTALACION: — TEMPERATURA AMBIENTE (SUELO) — TEMPERATURA MAXIMA DE. OPERACION = RESISTIVIOAD TERMICA DEL TERRENO = PROFUNDIDAD DE INSTALACION = CATIDAD DE CABLES EN UNA MISMA ZANJA = TIPO DE INSTALACION = SEPARACION ENTRE CABLES 25°. 90 °C, NaxsY. 150 ‘-em/w. 1.20 m. 3 UNIPOLARES EN PARALELO, NOXSY. DIRECTAMENTE ENTERRADOS. 70 mm. EN PARALELO, NOXSY. TABLA 9 PARAMETROS ELECTRICOS DE CABLES SUBTERRANEOS DE MT. — 22.9 kv. Teo ‘SECCION NUM. Ra R x xe (mma) Fases | (onm/xm) | (Ohm/km) | (Onm/xm) | (Ohm/Ken) wows 70 3 0.270 osei7_| 0.2637 | 1.840304 120 3 0.54 oni951 | 0.2440 | 18150404 240 3 o.o7e2 | 0.0961 | 02212 | 1.1684e-+04 50 3 0.64% 0822 0.261 | 21243e+08 95 3 0,320 0.810 0.259 _ | 179036408 Naaxsy 120 3 0.285 0.324 0.282 | 1,6403¢+06 185 3 on164 02210 0.237 | 116846404 400 3 0078 0,100) aia | 151506404 NOTA: — R : RESISTENCIA ELECTRICA A 90re. TABLA w10 CAPACIOAD DE CORRIENTE DE CABLES SUSTERRANEOS OE MT. 22.9 KV. PO. SECCION | CAPACIOAD DE CORRIENTE (A) comma) | nommat (*) | EMERGENCIA 50 186 222 Naxsy 7 228 272 120 309 ES 240 483 27 50 152 180 95 220 262 120 296 383 naaxsy | 185, 316 376 NoTA ©) CAPACIDAD DE CORRIENTE NOMINAL A — LOS VALORES CORRESPONDEN A TIPOS DE CARGA CON FACTOR DE CARGA LA TENPERATURA MAXIMA DE OPERACION < 075. PARAMETROS DE CABLES Y CONDUCTORES DE BT Y MT Pech @iuz 061 sun sa NORMA DE DISTRIBUCION RD-3-010 be 15 ENERO 008. SNID=200T CONDUCTORES AEREOS CONDICIONES DE INSTALACION: TEMPERATURA AMBIENTE 30°C. TEMPERATURA MAXIMA DE OPERACION 60°C, AA Y cu. = TEMPERATURA DE EMERGENCIA 75°C, AA Y CU, = VELOCIDAD DEL VIENTO 2 kem/n, — SEPARACION ENTRE CONDUCTORES SEGUN TIPO DE ESTRUCTURA, AA Y CU, JABLA WA PARAMETROS ELECTRICOS DE CONDUCTORES AEREOS DE M.T. - 22.9 KV. mp0 SSECCION Now. Re R x xe (ram2) Fases | (onm/xm) | (ohm/ke) | (onm/am) | (Ohm/Ken) ” 120 3 e220 | osezs | o4z41 | 2560ser05 240 3 01420 | oreza | 03072 | 2a01sc+05 16 s 1.1700 vseee | soos | soszievos 70 3 02730 | oie7 | oasae | 208a0c+05 Nora = Rt RESISTENCIA ELECTRICA A 60°C. = LA REACTANG/A INDUCTIVA TRIFASICA SE HA CALCULADO PARA UN SISTEMA TRIFASICO DE TRES ~ (A REACTANCIA INDUCTIVA TRIFASICA PARA CONDUCTORES DE AA Y CU, HA SIDO OBTENIDA PARA UNA DISPOSICION VERTICAL DE CONDUCTORES, SEPARADOS 1200 mm. TABLA 12 CAPACIOAD DE CORRIENTE DE CONDUCTORES AEREOS DE MT. — 22.9 KV, TPO ‘SECCION [_CAPACIDAD DE CORRIENTE (A) (mm2) | Noma (*) | EMERGENCIA 70 201 250 1 a 120 2a 355. i 240 472, 566 cu 35 182 225 70 278. 2 (©) CAPACIDAD OE CORRIENTE NOMINAL A LA TEMPERATURA MAXIMNA DE OPERACION, PARAMETROS DE CABLES Y CONDUCTORES DE 8T Y MT Moar F ech V@iuzce1 sun cA) NORMA DE DISTRIBUCION RO-3—019 PARAMETROS MECANICOS 1) BAJA TENSION — 0.22 KV. CONDUCTORES Y CABLES AEREOS LOS CUADROS SIGUIENTES PRESENTAN LOS PARAMETROS MECANICOS DE LOS TIPOS DE CONDUC- TORES Y CABLES EN REDES AEREAS DE BAIA TENSION OE LUZ OEL SUR, | TABLA 113 PARAMETROS MECANICOS DE CABLES AEREOS DE BAJA TENSION conouETOR PORTANTE nwo | seccion | Peso AOrURa reso | Real Alavi | EiasnetonD (m2) (kg/km) ka) (xa /ken) are) (kg/mm) 16 vaio oe 450 1186-05, 18900 | 4 25 223.0 624 45.0 1.15€-05, 18980 30 1500 3020 2050 | _1156~08 19900 70 2070 3020 2050 | _1A86=08 18980 16 235) eae 450 1186-08 18980 ems [35 o24 o24 450 1156-05, 19900 KH 30 1250 eae 450 1156-08 18980 Taga wit PARAMETROS MECANICOS DE CONDUCTORES AEREOS OF BAJA TENSION Ae nwo | secon | tort reso | neal avzo'e | Easncioad coma) eo) g/m) Gey | “ea/mmnay 16 oz 1610 | _1.708-05 12650 2s o92 2000 705-05 12650 a 30 1808 si00 | _1.708-08 12650 eI cr g 70 2529 e050 | _1.708~05 12650 Io} cy 3432 925.0 1.70E-05 12650 | a 120 2335 race | 1706-08 12850 fa ves 6005 vei9.0 | 1.708-05 12650 3s oe 25) 230-05 e000 Be 20 e008 o70 2306-08 | 5700 PARAMETROS DE CABLES Y CONDUCTORES DE BT Y MT [39] cuz cer. sums, NORMA DE DISTRIBUCION RD-3-010 2) MEDIA TENSION — 10 KV. MI CONDUCTORES Y CABLES AEREOS TORES Y CABLES EN REDES AEREAS DE MEDIA TENSION 10 KV. DE LUZ EL SUR TABLA N15 PARAMETROS MECANICOS DE CABLES AEREOS DE MT. ~ 10 KV. wo | seccon | reso | fordma | eso [neat A400 | EORton Goma) | tea/tem) oo) (es/kem) Gro | “tes/mm2) 70 4200 2673 549 1156-05 “e960 RH nazxsa2y-s = 720) 3300 2673 549 1186-05 78980 TABLA Ni PARAMETROS MECANICOS DE CONDUCTORES AEREOS DE MT. ~ 10 KV. TRO ‘SECCION "ROTURA PESO LUNEAL A 20% | ELASTICIOAD Ik} HY (roma) (a) (xa/arm) (fo) | _Gea/mmay 3 924 3 2.30605 5700 a 70 1918 164 2.30605 5700 kd) 135 5255 510 2.30605 5700 3 250 12 1. 706-05 12650 a zi B16 192 1708-05 12650 S| 25 1081 220 1. 706=05 12650 lo} ou = a 35 1366 310 5708-05 12650 | 2 1655) 353 1. 70E~05 12650 7 2602 586 5708-05 12650 70 2782 608) 1. 706-05 12650 f 70 202 770 2.308-05 or z sx 120 3502 80 2306-08 e122 PARAMETROS DE CABLES Y CONDUCTORES DE BT Y MT fly) @euz oer sur sa, NORMA DE DISTRIBUCION RD-3—010 ORNIU-200T 3) MEDIA TENSION — 22.9 kv. CONDUCTORES AEREOS EL CUADRO SIGUIENTE PRESENTA LOS PARAMETROS MECANICOS DE LOS TIPOS EN REDES AEREAS DE MEDIA TENSION 10 KV. DE LUZ DEL SUR. CONDUCTORES TABLA wi. PARAMETROS MECANICOS DE CONDUCTORES AEREOS DE MT. ~ 22.9 KV. To mcaon | RAE peso | GEE PEAT, | WODULO DE (roma) (9) (4s/aen) are) (ka/enen2) 35 980 96 2,306-05 5700 70 118 164 2.306-05 5700 240 6720 662 2,306-05 5700 16 48 1a .708-05 12650 PARAMETROS DE CABLES Y CONDUCTORES DE BT Y MT Beuz ver sur sal NORMA DE DISTRIBUCION

You might also like