You are on page 1of 2
SUN OIEoR e CN Coe est tenes) CS Smee gue ee Ree od ONE UC EDP) Orca a nats Cena Orn Cece anita unmet) eee) OP ere eras a eR Cc Petrome mcr CR cg aera erat Ream sc Oct cased Sea ead PS eee eed Set ee ee ee 7 Changing the way you think choot valves... CONSTRUCTION AND TECHNICAL INFORMATION ‘Advance Large Sze Balancing Valves, a fst in the worl design by ‘Advance, sa unique Manual Balancing solution forthe present rendof large sine HUAC and dnt coobne plants, optimising space, and "HateoftheartCFDtoosvaldatedon n-noute aw testbed ‘CONSTRUCTION: High Performance (double ecentic) Soft Seated Buterfy valves reglatingmerberwithaunique receiv ergineered Afeertial pressure measurement stem tat Indes two measuring rings designedto read average static ressre tthe ipecrossactions. [GEARBOX: Thealve operation by custom bul 0 baclash gearbox The gearbox s capable of setting vale opening angle within 205° proving 2 flow setting accuracy of 7%. The gearox's provided wi ‘tamper prooflocking arrangement te prvert unauthorised esetngot {justable top. This arrangement prevents unauthorised resetting of thevalve opening the maximum set value butenabingcloingthe vale incucingtoralshutor ‘VALVE SELECTION: Vsive selection shallbe normally made batedon pipe Se afer ensuring the flow ates within the minimum and maximum flowrateofthevalveandpressureropis2round 20010 500mm He, INSTALLATION: Vale maybe installed in horaontal, vertical andsianting| pipelines. Diferental pressure reading tobe coreced fr vertical and $Santinginsallaton, Minimom of Dastancs to be maintained betwen REGULATION: Flow regulation in a wide range of 20° to 70° anele of requlaion pressure taps and one et of preseure test quarter turn cocks, resute drop acrosetne valve can be measured with ADVANCE dial diferntal Pressure Meter having instant couplings wth the pressure test cocks Pressure test cock are opened by 1/4 turn using 6mm square double diferent pressure acros the valve noting the angle of opening of the ‘valve and tien using the pubshed Hy value fr the valve or ADVANCE Flow Computation Software. During purging of ppelie ensure hat the measuring rings ae replaced wth dummy fanges to aeld blocking of ‘OPMONAL: Hand hele gta ferential Pressure Meter, Auto cosng SOFTWARE & SERVICES: ADVANCE Flow Comoutaton Software and Sjstem dalancng Sofware that work with the Hand held digital ‘iter BlorcingSenices to achieve maximum energy saving right om commissioning Ay CCFD Analysis Showing Velocity in Partially Open Dise ‘Size Range: ON 35010 081000 Pressure Rating: PN 16 Standard, PN 20 Optional Temperature: - 40°C to 120°C ‘Fluid Clea Water / Glycol solution Face To face Distance: As per 1SO 5752 Table & ( Globe Valves) Valve Model: Flange as per 1S 6392 PN 16 35 standard Others optional Flow measurement accuracy: 27% ‘Maximum flow : Upto Sms Mi velocky BODY -PN 16: Cast iron FG 260 =PN20: SG ran IS 1865 Gr 450 /10 DISC: SG iran 'S 1865 Gr 450/30 or Eq SEAL: EPOM (Elastomer) SHAFI/STEM 55.431 TRIM and measuring ings: SS 304 or equivalent Body Extension, Flanges: Low catbon steel 2082 or Eq Worm Gear bx: Body and worm wheel inSG Iron and $5 410 Testing: + hydro Testing Shell (Body) PNG | 24 bar @) PN20 | 30 br (a) Seat Tr barl 22a (e) Direction of Flow : Marked onthe Valve Body VALVE DATA TABLE pnt ce pin a ro an

You might also like