You are on page 1of 68

Gas Dispersion Modeling for Flare Stacks

Using Flaresim

Prepared by:
Hafif Aulia Nur Rahman
https://www.linkedin.com/in/hafifaulianurrahman/

February, 15th 2024


Gas Dispersion Modeling for Flare Stacks
linkedin.com/in/hafifaulianurrahman
Using Flaresim

Table of Contents
Page
Case Study .......................................................................................................................................3
A. Create Base Case ........................................................................................................................4
B. Jet Dispersion Calculation ........................................................................................................14
C. Gaussian Dispersion (Contour Plot) .........................................................................................19
D. Gaussian Dispersion (Line Plot) ...............................................................................................28
E. Dispersion Analysis Comments ................................................................................................44
Attachment Gas Dispersion Modeling for Flare Stacks Using Flaresim .......................................46

Page 2 of 46
Gas Dispersion Modeling for Flare Stacks
linkedin.com/in/hafifaulianurrahman
Using Flaresim

Gas Dispersion Modeling for Flare Stacks Using Flaresim

Case Study
Illustrate and analyze gas dispersion (Jet Dispersion and Gaussian Dispersion) from an existing
Flare Stack in a refinery under normal conditions and flame out conditions. The following data
have been provided to perform gas dispersion modeling using Flaresim :
A. Flared Fluid
1. Composition (Mole Fraction) = 90% Methane, 8% Ethane, and 2% H2S
2. Temperature = 75oC
3. Reference Pressure = 1.013 bar a
4. Mass Flow Rate = 50,000 kg/hr

B. Mechanical Data
1. Tip Type = Pipe
2. Tip Diameter = 387.4 mm (15.25 in)
3. Tip Length =1m
4. Stack Length = 20 m
5. Stack Orientation = Vertical
6. Stack Location = At Origin, 0, 0, 0 (in this case study, the stack location
assumption is used instead of using overlay feature)

C. Environment Data
1. Temperature = 15oC
2. Wind Speed = 10 m/s from North

Page 3 of 46
Gas Dispersion Modeling for Flare Stacks
linkedin.com/in/hafifaulianurrahman
Using Flaresim

A. Create Base Case

Page 4 of 46
A. Create Base Case
1. Start the Flaresim program through the Windows Start button in usual way.
Click / “Search” feature → Type “Flaresim” → Click “Open”

Page 5 of 46
2. After running the Flaresim software, the Setup Wizard will open automatically. Select the European units set for easy of entering
the remaining data. After that, proceed to the next step by clicking the Next button.

Setup Wizard

1
2

*Note : However, you can use other unit sets (Default SI or Default Field) if you are not familiar with European units set.

Page 6 of 46
3. In the Fluid tab, click “From Composition” option instead of “Specified Properties” because the composition of the gas to be
burned is already known.

After that, enter the previously known process data :


• Temperature = 75oC • Reference Pressure = 1.013 bar a (Default)
• Composition (Mole Fraction) = 90% Methane, 8% Ethane, and 2% H2S

1 2

*Note : After you enter the operating conditions and composition of the gas fluid to be burned, the fluid properties (Molecular
Weight, Lower Heating Value, Cp/Cv, LEL, Saturation, Critical Pressure, and Critical Temperature) will be calculated by Flaresim
automatically.
Page 7 of 46
4. In the Tip tab, select the radio button to set the tip type to a Pipe Tip, according to existing existing mechanical data of Flare Stack
(Z-0101).

After that, in the F Factor Method section, select the Generic Pipe method.

*Note : Generic Pipe F Factor is a proprietary correlation based on refitting other methods (Kent, Tan, Natural Gas, and Cook
methods) across a range of exit velocities and molecular weights and represents a good approach when modelling gas pipe tips.

Page 8 of 46
5. Still in the Tip tab, move to Tip Sizing section and enter the following data :
• Mass Flow Rate = 50,000 kg/hr
• Tip Diameter = 387.4 mm (15.25 in)

*Note : The Mach Number value, marked in red font, will be calculated automatically after you enter the Tip Diameter data.

Page 9 of 46
6. In the Environment tab, enter the following data :
• Wind Speed = 10 m/s • Temperature = 15oC
• Wind Direction = 0o (From North) • Include Solar Radiation = Checked
• Other Parameters = Leave as default unless otherwise stated or data from environmental laboratory tests provided.

*Note :
• If the direction of the wind is different, use the following value as guidance : East = 90o , South = 180 o , West = 270o.
• When considering whether to include solar radiation in gas dispersion modeling for flaring events, factors such as event
frequency and duration, personnel presence, alignment of sun and flare radiation, use of protective clothing, and ease of escape
from exposed areas should be carefully evaluated.

Page 10 of 46
7. In the Stack tab, enter the following data :
• Stack Angle = Vertical
• Length = 20 m

*Note : The value of Angle from Horizontal and from North parameters will be calculated automatically after you defined the flare
stack orientation in the Stack Angle section.

Page 11 of 46
8. In the Receptors tab, leave all parameter as default unless otherwise stated/defined by yourself.

*Note : The Radiation Limit is set at 4.733 kW/m2 where at this value personnel can carry out an emergency for 2 minutes (based
on API STD 521) without protection/shielding but with appropriate clothing.

Page 12 of 46
9. In the Calculations tab, select the Brzustowski method as per recommendation from API STD 521. However, you are free to choose
other calculation methods according to your process needs/requirements and your engineering judgement.

Page 13 of 46
Gas Dispersion Modeling for Flare Stacks
linkedin.com/in/hafifaulianurrahman
Using Flaresim

B. Jet Dispersion Calculation

Page 14 of 46
linkedin.com/in/hafifaulianurrahman Gas Dispersion Modeling for Flare Stacks Using Flaresim

B. Jet Dispersion Calculation


In this section, we will conduct a jet dispersion study to examine the considerations of flammable gas surrounding the flare in case
of flame failure.
1. Before enabling the jet dispersion calculations, we will create a new Receptor Grid to see the results more clearly. Select the
Receptor Grid branch in the Case Navigator and click the Add button. In the new view enter the following :
• Name = Elevation • Elevation Maximum = 300 m
• Grid Plane = Elevation-Northing • Northing Minimum = -300 m
• Grid Offset =0m • Northing Maximum = 100 m
• Elevation Minimum =0m • Leave remaining values at defaults.

3
2 4

Page 15 of 46
linkedin.com/in/hafifaulianurrahman Gas Dispersion Modeling for Flare Stacks Using Flaresim

2. Open the Calculation Options view by selecting it in the Case Navigator and clicking the view button. Select the check box
labelled Jet Dispersion in the Include Options section of the General Tab.

Click the Calculate button. The message window will include a warning from the dispersion calculations which states that the jet
will interact with the ground at a distance of 2,059 m. This is not a problem as indicated by the green background colour.

2 4

Page 16 of 46
linkedin.com/in/hafifaulianurrahman Gas Dispersion Modeling for Flare Stacks Using Flaresim

3. Return to the view for your Elevation receptor grid and select the Concentrations tab. You should see a result that looks
something like that shown below :

2 3

Page 17 of 46
linkedin.com/in/hafifaulianurrahman Gas Dispersion Modeling for Flare Stacks Using Flaresim

*Note : If the plot of jet dispersion modeling results looks too small, you can use the Zoom feature. See the following steps :

Page 18 of 46
Gas Dispersion Modeling for Flare Stacks
linkedin.com/in/hafifaulianurrahman
Using Flaresim

C. Gaussian Dispersion (Contour Plot)

Page 19 of 46
linkedin.com/in/hafifaulianurrahman Gas Dispersion Modeling for Flare Stacks Using Flaresim

C. Gaussian Dispersion (Contour Plot)


In this section, we will analyze the dispersion of H2S emitted from the flare tip in the scenario of a flame outage.
1. Create a Dispersion Object by selecting the Dispersion branch in the Case Navigator and clicking the Add button. In the Dispersion
view enter the following data on the Input Data tab as shown below :
• Name = H2S Contour • Northing Maximum =0m
• Pollutant Source = Unburnt Flared Fluid • Easting Minimum = -500 m
• Calculation Type = Contour Plot • Easting Maximum = 500 m
• Contours Height =0m • Number of Points, Northing and Easting = 51
• Northing Minimum = -1,000 m

3
2 4
5

6
1

Page 20 of 46
linkedin.com/in/hafifaulianurrahman Gas Dispersion Modeling for Flare Stacks Using Flaresim

2. Move to the Pollutant Data tab, select the H2S component only. For a contour plot, only one component can be selected.

Page 21 of 46
linkedin.com/in/hafifaulianurrahman Gas Dispersion Modeling for Flare Stacks Using Flaresim

3. Open the Calculation Options view and select the Gaussian Dispersion check box to enable these calculations.

After that, click the Calculation button.

4
3

Page 22 of 46
linkedin.com/in/hafifaulianurrahman Gas Dispersion Modeling for Flare Stacks Using Flaresim

4. Select the H2S Contour view and then click Results tab. Change the display option to the Plot option. The plot shows the ground
level concentration contours for H2S downwind of the stack as shown belows :

3
2
4
5

Page 23 of 46
linkedin.com/in/hafifaulianurrahman Gas Dispersion Modeling for Flare Stacks Using Flaresim

5. The results shown have been calculated at the default environmental conditions. Atmospheric stability is characterised as Class
D with dispersion coefficients applicable to Rural terrain around the flare. Open the Environment view at the Dispersion Data tab
and test the effect on the dispersion results as you change the Atm. Stability class from A (most turbulent) to F (most stable) and
the effect of changing the terrain from Rural to Urban (if you want to try it). For this case, we will test the effect of changing
the Atm. Stability class from A to F without changing the terrain.

2
3

1
4

The results of dispersion test if the Atm. Stability changes from class A (most turbulent) to F (most stable) are as follows :

Page 24 of 46
linkedin.com/in/hafifaulianurrahman Gas Dispersion Modeling for Flare Stacks Using Flaresim

Atmospheric Stability Class H2S Dispersion Results

Pasquill A
(Most Turbulent)

Pasquill B

Page 25 of 46
linkedin.com/in/hafifaulianurrahman Gas Dispersion Modeling for Flare Stacks Using Flaresim

Atmospheric Stability Class H2S Dispersion Results

Pasquill C

Pasquill D

Page 26 of 46
linkedin.com/in/hafifaulianurrahman Gas Dispersion Modeling for Flare Stacks Using Flaresim

Atmospheric Stability Class H2S Dispersion Results

Pasquill E

Pasquill F
(Most Stable)

*Note : You will see that the H2S concentrations are higher closer to the flare when atmosphere is more turbulent. The
sensitivity of the results to these parameters shows the necessity of selecting the appropriate environment settings for your particular
flare location.

Page 27 of 46
Gas Dispersion Modeling for Flare Stacks
linkedin.com/in/hafifaulianurrahman
Using Flaresim

D. Gaussian Dispersion (Line Plot)

Page 28 of 46
linkedin.com/in/hafifaulianurrahman Gas Dispersion Modeling for Flare Stacks Using Flaresim

D. Gaussian Dispersion (Line Plot)


In this section, we will consider the downwind concentrations of pollutant in the combustion gases of the flare when it is operating.
1. In the Case Navigator select the Dispersion branch and click Add to create a new dispersion object. In the Input Data tab of its
view enter the following data :
• Name = Combustion Emissions • Height for Calculation =0m
• Pollutant Source = Combustion Product • Downwind Distance Minimum = 100 m
• Calculation Type = Downwind Line Plot • Downwind Distance Maximum = 10,000 m
• Reference Location = Origin • Number of Points = 100

3
2
4
5

6
1

Page 29 of 46
linkedin.com/in/hafifaulianurrahman Gas Dispersion Modeling for Flare Stacks Using Flaresim

2. In the Pollutant tab, select the SO2, NO, CO and Methane pollutants for calculation by checking the box alongside these
components. Click Calculate in the Navigation pane.

3
1

Page 30 of 46
linkedin.com/in/hafifaulianurrahman Gas Dispersion Modeling for Flare Stacks Using Flaresim

Some of the components in this list, the CO2, H2O, SO2 are calculated directly from combustion of the components in the flared
gas. The Fluid view, Combustion Results tab shows the stoichiometric fraction of each of these components generated by
combustion of the flared gas.

2
3
1

Page 31 of 46
linkedin.com/in/hafifaulianurrahman Gas Dispersion Modeling for Flare Stacks Using Flaresim

The remaining components, NOx (assumed as NO), CO and unburnt hydrocarbon (assumed as CH4) are calculated as typical
emissions resulting from hydrocarbon combustion. The quantities of each component generated is calculated by default, using the
global basis defined on the Calculation Option view Emissions tab.

3
2

Page 32 of 46
linkedin.com/in/hafifaulianurrahman Gas Dispersion Modeling for Flare Stacks Using Flaresim

Alternatively in Expert Mode, the emissions basis for each Tip can be specified on the Emissions tab of the Tip view.

2
4
1

Page 33 of 46
linkedin.com/in/hafifaulianurrahman Gas Dispersion Modeling for Flare Stacks Using Flaresim

The quantities of each component in the combustion gases for each Tip are displayed on the Combustion Results tab of the Tip
view.

Page 34 of 46
linkedin.com/in/hafifaulianurrahman Gas Dispersion Modeling for Flare Stacks Using Flaresim

3. Since the dispersion of the combustion gases will be dependent on the flame temperature, we will now set this. Open the Tip View
and select the Fluids tab. At the bottom of this view you may input a value for the flame temperature or clear the specified
value to allow it to be calculated from the specified combustion air ratio.

Set the Combustion Air Ratio to 3.0 and clear the specified flame temperature.

Page 35 of 46
linkedin.com/in/hafifaulianurrahman Gas Dispersion Modeling for Flare Stacks Using Flaresim

4. Open the Environment view and set the Atm. Stability Class to PasquillB. After that, click the Calculate button in the Navigation
pane.

3
1 4

Page 36 of 46
linkedin.com/in/hafifaulianurrahman Gas Dispersion Modeling for Flare Stacks Using Flaresim

5. Return to the Combustion Gas Results tab of the Tip view to see the calculated flame temperature of 722.9oC and the combustion
gas compositions.

2 3

Page 37 of 46
linkedin.com/in/hafifaulianurrahman Gas Dispersion Modeling for Flare Stacks Using Flaresim

6. In the Combustion Dispersions view, go to the Results page and select the Plot result to view the results as shown below. The
peak concentration of SO2 is calculated at ±68 µg/m3 at a distance of approximately ±1,400 m downwind of the flare tip.

3
2
4

5
1

Page 38 of 46
linkedin.com/in/hafifaulianurrahman Gas Dispersion Modeling for Flare Stacks Using Flaresim

6. As in the previous section, open the Environment view to the Dispersion Data tab and test the effect of changing the Atm.
Stability Class and Terrain class settings. You will find that for stable atmospheric conditions, stability classes E and F, the
emission concentrations are still rising at the maximum downwind distance we have defined (10,000 m). For this case, we will
test the effect of changing the Atm. Stability class from A to F without changing the terrain.

2
3

1
4

The results of dispersion downwind test if the Atm. Stability changes from class A (most turbulent) to F (most stable) are as follows:

Page 39 of 46
linkedin.com/in/hafifaulianurrahman Gas Dispersion Modeling for Flare Stacks Using Flaresim

Atmospheric Stability Class Results of Downwind Line Analysis for Combustion Emissions

Pasquill A
(Most Turbulent)

Pasquill B

Page 40 of 46
linkedin.com/in/hafifaulianurrahman Gas Dispersion Modeling for Flare Stacks Using Flaresim

Atmospheric Stability Class Results of Downwind Line Analysis for Combustion Emissions

Pasquill C

Pasquill D

Page 41 of 46
linkedin.com/in/hafifaulianurrahman Gas Dispersion Modeling for Flare Stacks Using Flaresim

Atmospheric Stability Class Results of Downwind Line Analysis for Combustion Emissions

Pasquill E

Pasquill F
(Most Stable)

Page 42 of 46
linkedin.com/in/hafifaulianurrahman Gas Dispersion Modeling for Flare Stacks Using Flaresim

7. Save As the case and Print the results. For this gas dispersion modeling, we will use PasquillD as the default Atm. Stability Class.

1 2

Page 43 of 46
Gas Dispersion Modeling for Flare Stacks
linkedin.com/in/hafifaulianurrahman
Using Flaresim

E. Dispersion Analysis Comments

Page 44 of 46
linkedin.com/in/hafifaulianurrahman Gas Dispersion Modeling for Flare Stacks Using Flaresim

E. Dispersion Analysis Comments


There are two general comments on the dispersion analysis capabilities of Flaresim :
1. The Jet Dispersion analysis for flammable gas concentrations is based on the Cleaver & Edwards jet dispersion model. This is
regarded as a reasonable model for concentrations close to the source. However it does assume dispersion in “free air” and does not
consider the effect of structures that might modify dispersion patterns and lead to higher concentrations of flammable gas than
predicted by Flaresim. A more detailed analysis with specialised software would be required in these situations.
2. The Gaussian Dispersion calculation for combustion gases and flared fluid over longer distances, is a simpler theoretical model
that does not include detailed terrain effects. As such it should be considered as suitable for screening calculations to indicate a
possible need for more detailed analysis. Chapter 11 has additional comments on the implementation of the Gaussian dispersion
model in Flaresim.

Page 45 of 46
Gas Dispersion Modeling for Flare Stacks
linkedin.com/in/hafifaulianurrahman
Using Flaresim

Attachment
Gas Dispersion Modeling for Flare Stacks
Using Flaresim

Page 46 of 46
linkedin.com/in/hafifaulianurrahman Thursday, February 15, 2024

2/15/2024 12:36:31 AM Flaresim 2023.2.116 Page 1


Job
Run by
Problem
DataFile D:\Hafif A. N. R\Posting LinkedIn\File Calculations\24. Gas Dispersion Modeling for Flare Stacks Using Flaresim\Gas Dispersion Modeling for Flare Stacks Using Flaresim.fsw
Time 2/15/2024 12:36:31 AM
This Printout Is Not Valid Unless Page 1 Is Attached And Completed

QUALITY ASSURANCE CONTROL SHEET

Check Code

Calculations By

Date

Time

Calculations Approved by

Date

Time

Page 1 of 22
linkedin.com/in/hafifaulianurrahman Thursday, February 15, 2024

2/15/2024 12:36:31 AM Flaresim 2023.2.116 Page 2


Job
Run by
Problem
DataFile D:\Hafif A. N. R\Posting LinkedIn\File Calculations\24. Gas Dispersion Modeling for Flare Stacks Using Flaresim\Gas Dispersion Modeling for Flare Stacks Using Flaresim.fsw
Time 2/15/2024 12:36:31 AM
This Printout Is Not Valid Unless Page 1 Is Attached And Completed

Calculation Options
General
Method Brzustowski Nbr Flame Elem. 1 Calculation mode Sizing
Element Position 50 Active Environment Environment 1 Noise Method Spectrum
Liquid Buoyancy 0.030 m/s Pipe Buoyancy 3.048 m/s Sonic Buoyancy 4.572 m/s

Options
Expert Mode Active Windchill Ignored Noise Attenuation Active
Jet Dispersion Active Gaussian Dispersion Active
Run Dynamics False Run Case Studies True

Heat Transfer Coef. in W/m2/K Temperature Rise Calculations


HTC = 1.25 * WindSpeed^ 1.00 + 4.54 Wind speed below 4.572 m/s Exposure Time 900.0 s
HTC = 3.18 * WindSpeed^ 0.75 + 0.00 For higher wind speeds Nbr of Steps 90

Emission Data
NOX Basis Mass/Heat Release CO Basis Mass/Heat Release HC Basis Mass/Heat Release
NOX Rate 0.02923 kg/GJ CO Rate 0.15900 kg/GJ HC Rate 0.06016 kg/GJ

Fitting Data
Fitting Tip Fitting Point <All Active>
Fitting Result ----- Fitting Error -----

Sizing Information
Stack to be sized None Minimum Length 5.00 m Maximum Length 100.00 m
Sizing Wind Direction ----- Sizing Wind Speed ----- Calculated Size -----

Pressure Profile
Pressure Tolerance 0.000 bar Tip Elements 4 Riser Elements 40

Dispersion Data
Jet Disp. Averaging Short Jet Disp. Stop Conc. 0.00001 mole/mole

Environmental data
Environment: Environment 1 - Active

Atmosphere
Pressure 1.013 bar Temperature 15.0 C Humidity 10.00 %
Wind Speed 10.000 m/s Wind Direction 0.00 °

Background
BackGround Noise 60.0 dB Solar Radiation 0.800 kW/m2
Inc. Background Noise Active Inc. Solar Radiation Active

Transmissivity
Method Calculated Min Value 1.000 Max Value 1.000

Page 2 of 22
linkedin.com/in/hafifaulianurrahman Thursday, February 15, 2024

2/15/2024 12:36:31 AM Flaresim 2023.2.116 Page 3


Job
Run by
Problem
DataFile D:\Hafif A. N. R\Posting LinkedIn\File Calculations\24. Gas Dispersion Modeling for Flare Stacks Using Flaresim\Gas Dispersion Modeling for Flare Stacks Using Flaresim.fsw
Time 2/15/2024 12:36:31 AM
This Printout Is Not Valid Unless Page 1 Is Attached And Completed

Wind Rose Calculations


Wind Speed Array Ignored Wind Speed vs Direction Ignored

Dispersion Data
Stability Class PasquillD Terrain Class Rural Surface Roughness 0.20 m
Wind Reference Height 10.00 m Correct Wind Speed False

Stack Configuration Data


Stack: Stack 1 - Active

Input Data

Base point name Stack 1 (Base) Base refers to Origin


Base - Northing 0.00 m Base - Easting 0.00 m Base - Elevation 0.00 m
Base - Angle from North 0.00 ° Base - Angle to Horizontal 0.00 ° Base - Radius 0.00 m
Stack
Rotation from North 0.00 ° Angle to Horizontal 90.00 ° Stack Length 20.00 m

Sterile Area
Elevation 0.00 m Noise Basis Noise Run SA Calcs False

Fluid Data
Fluid: Fluid 1

Input Data
Thermo Method Flaresim
Use Temp Corr. False Use RK ZFactor True

LHV 48333.02 kJ/kg Tc -69.6 C LEL 4.71 %


Fluid Temperature 75.0 C Pc 47.475 bar Saturation 100.00 %
Molecular Weight 17.526 Cp/Cv 1.303 Ref. Pressure 1.013 bar

Composition in mole fraction


Hydrogen sulphide 0.020000 Methane 0.900000 Ethane 0.080000

Page 3 of 22
linkedin.com/in/hafifaulianurrahman Thursday, February 15, 2024

2/15/2024 12:36:31 AM Flaresim 2023.2.116 Page 4


Job
Run by
Problem
DataFile D:\Hafif A. N. R\Posting LinkedIn\File Calculations\24. Gas Dispersion Modeling for Flare Stacks Using Flaresim\Gas Dispersion Modeling for Flare Stacks Using Flaresim.fsw
Time 2/15/2024 12:36:31 AM
This Printout Is Not Valid Unless Page 1 Is Attached And Completed

Results
Flue to Feed Volume Ratio 3.140 Stoichiometric O2 2.110
Enthalpy @ 25°C 580.99 kJ/kg Enthalpy @ Fluid Temp. 690.65 kJ/kg

Stoichiometric Flue Gas Composition


Carbon Dioxide 0.33758 mole/mole Water 0.65605 mole/mole Oxygen 0.00000 mole/mole
Nitrogen 0.00000 mole/mole Sulphur Dioxide 0.00637 mole/mole

Tip Data
Tip: Tip 1 - Active

Input Data
General
Tip Type Pipe Located on stack Stack 1 Nbr of Burners 1
Angle to Horizontal 90.00 ° Angle to North 0.00 °
Tip Length 1.00 m Tip Diameter 387.40 mm Tip Opening 100.00 %
Seal Type None Diameter Basis Tip

Fluids
Fluid Fluid 1 LP Fluid Assist Fluid
Fluid Mass Flow 50000.000 kg/h LP Mass Flow 0.000 kg/h Assist Mass Flow 0.000 kg/h
Fluid Mole Flow 0.792 kgmole/s LP Mole Flow 0.000 kgmole/s

Pressure Drop
Riser Diameter 387.40 mm Tip Outlet Pressure ----- Contraction Coeff. 1.000
Roughness 0.02500 mm Exit Loss 1.000

Flame and Radiation


F Factor Method Generic Pipe
Combustion Air Ratio 3.000 Flame Temperature 722.9 C
Flame Length Method Brzustowski
Radiation Method Global Flame Element Count 1 Element Position 50.00 %

Noise
Noise Method Acoustic Eff. Comb. Efficiency 0.00010 % Peak Frequency 500 Hz
Jet Noise Method Flaresim

Purge Gas
Purge Gas Fluid Nitrogen Purge Area Basis Stack Purge Fixed Velocity 0.060 m/s
Purge Fixed Volume Flow 0.283 m3/h Purge HUSA O2 6.00 % Purge HUSA Height 7.62 m

Emission Data
NOX Basis Mass/Heat Release CO Basis Mass/Heat Release HC Basis Mass/Heat Release
NOX Rate 0.02923 kg/GJ CO Rate 0.15900 kg/GJ HC Rate 0.06016 kg/GJ

Page 4 of 22
linkedin.com/in/hafifaulianurrahman Thursday, February 15, 2024

2/15/2024 12:36:31 AM Flaresim 2023.2.116 Page 5


Job
Run by
Problem
DataFile D:\Hafif A. N. R\Posting LinkedIn\File Calculations\24. Gas Dispersion Modeling for Flare Stacks Using Flaresim\Gas Dispersion Modeling for Flare Stacks Using Flaresim.fsw
Time 2/15/2024 12:36:31 AM
This Printout Is Not Valid Unless Page 1 Is Attached And Completed

Tip: Tip 1 - Results


General
Flame Length 19.25 m Heat Release 671290.0 kW Tip End - Northing 0.00 m
API Flame Length 54.40 m Frac.Heat Radiated 0.166 Tip End - Easting 0.00 m
Exit Temperature 75.0 C Actual Volume Flow 81402.323 m3/h Tip End - Elevation 21.00 m
Assist Fluid Mass Flow ----- Assist Fluid Flow Ratio ----- Wind Speed At Tip 10.000 m/s

Velocities and Pressure Drop


Exit Velocity 191.835 m/s Tip Outlet pres. 1.013 bar Total Outlet pres. 1.126 bar
Sonic Velocity 463.660 m/s Tip Backpres. 1.017 bar Total Backpres. 1.130 bar
Exit Mach Number 0.414 Seal Backpres. 1.017 bar Total Backpres. 1.130 bar
Contraction Coeff. 1.000 Stack Backpres. 1.090 bar Total Backpres. 1.195 bar
Tip Pressure Drop 0.004 bar Tip Total Pressure Drop 0.003 bar
Seal Pressure Drop 0.000 bar Seal Total Pressure Drop 0.000 bar
Stack Pressure Drop 0.073 bar Stack Total Pressure Drop 0.065 bar

Flame Shape Points


X Y Z
1 0.00 m 0.00 m 21.00 m
2 -10.58 m 0.00 m 34.11 m

3D Flame Shape Chart

Page 5 of 22
linkedin.com/in/hafifaulianurrahman Thursday, February 15, 2024

2/15/2024 12:36:31 AM Flaresim 2023.2.116 Page 6


Job
Run by
Problem
DataFile D:\Hafif A. N. R\Posting LinkedIn\File Calculations\24. Gas Dispersion Modeling for Flare Stacks Using Flaresim\Gas Dispersion Modeling for Flare Stacks Using Flaresim.fsw
Time 2/15/2024 12:36:31 AM
This Printout Is Not Valid Unless Page 1 Is Attached And Completed

2D Flame Shape Chart, Northing-Easting

2D Flame Shape Chart, Northing-Elevation

Page 6 of 22
linkedin.com/in/hafifaulianurrahman Thursday, February 15, 2024

2/15/2024 12:36:31 AM Flaresim 2023.2.116 Page 7


Job
Run by
Problem
DataFile D:\Hafif A. N. R\Posting LinkedIn\File Calculations\24. Gas Dispersion Modeling for Flare Stacks Using Flaresim\Gas Dispersion Modeling for Flare Stacks Using Flaresim.fsw
Time 2/15/2024 12:36:31 AM
This Printout Is Not Valid Unless Page 1 Is Attached And Completed

2D Flame Shape Chart, Easting-Elevation

Noise Results
Peak sound pressure
Distance 30.00 m Sound pressure 107.7 dB

Noise Spectrum Results

Frequency Total PWL Combustion PWL Jet PWL


Hz dB dB dB
31.3 111.2 110.8 100.8
62.5 119.6 119.3 107.7
125.0 127.8 127.8 108.0
250.0 136.3 136.3 105.4
500.0 144.8 144.8 100.9
1000.0 142.0 142.0 95.3
2000.0 139.2 139.2 89.4
4000.0 136.4 136.4 83.4
8000.0 133.6 133.6 77.4
16000.0 130.8 130.8 71.4

Page 7 of 22
linkedin.com/in/hafifaulianurrahman Thursday, February 15, 2024

2/15/2024 12:36:31 AM Flaresim 2023.2.116 Page 8


Job
Run by
Problem
DataFile D:\Hafif A. N. R\Posting LinkedIn\File Calculations\24. Gas Dispersion Modeling for Flare Stacks Using Flaresim\Gas Dispersion Modeling for Flare Stacks Using Flaresim.fsw
Time 2/15/2024 12:36:31 AM
This Printout Is Not Valid Unless Page 1 Is Attached And Completed

Noise Spectrum

Combustion Results General


Adiabatic Flame Temperature 854.2 C Calculated Flame Temperature 722.9 C

Combustion Gas Mass Flow


Carbon dioxide 132087.894 kg/h Water 105547.931 kg/h Oxygen 386020.263 kg/h
Nitrogen 1881382.701 kg/h Sulphur dioxide 3655.333 kg/h Nitrogen monoxide 70.650 kg/h
Carbon monoxide 384.239 kg/h Methane 145.388 kg/h Argon 30919.566 kg/h

Combustion Gas Mole Flow


Carbon dioxide 0.834 kgmole/s Water 1.627 kgmole/s Oxygen 3.351 kgmole/s
Nitrogen 18.656 kgmole/s Sulphur dioxide 0.016 kgmole/s Nitrogen monoxide 0.001 kgmole/s
Carbon monoxide 0.004 kgmole/s Methane 0.003 kgmole/s Argon 0.215 kgmole/s

Purge Gas Results


Fixed velocity rate 30.149 kg/h Fixed volume velocity 0.001 m/s Fixed volume rate 0.335 kg/h
HUSA velocity 0.005 m/s Reduced HUSA velocity 0.005 m/s API velocity -----
HUSA rate 2.509 kg/h Reduced HUSA rate 2.509 kg/h API flow -----

Page 8 of 22
linkedin.com/in/hafifaulianurrahman Thursday, February 15, 2024

2/15/2024 12:36:31 AM Flaresim 2023.2.116 Page 9


Job
Run by
Problem
DataFile D:\Hafif A. N. R\Posting LinkedIn\File Calculations\24. Gas Dispersion Modeling for Flare Stacks Using Flaresim\Gas Dispersion Modeling for Flare Stacks Using Flaresim.fsw
Time 2/15/2024 12:36:31 AM
This Printout Is Not Valid Unless Page 1 Is Attached And Completed

Receptor Points
Receptor Point Summary
Name Status Northing Easting Elevation Radiation Avg. Noise Noise NoiseA Temp.
m m m kW/m2 dB dB dB C
RP_1 Active -10.00 0.00 0.00 9.402 99.8 109.8 108.5 82.2

Receptor Point: RP_1 - Active

Input Data
Location Properties Sizing
Northing -10.00 m Emissivity 0.700 Max. Radiation 4.733 kW/m2
Easting 0.00 m Absorbtivity 0.700 Observed Radiation -----
Elevation 0.00 m Mass per Area 24.0 kg/m2 Max. Noise -----
Location rel. to Origin Area Ratio 2.000 Max. Average Noise -----
Angle From North 180.00 ° Mass Cp 450.000 J/kg/C Max.A Noise -----
Angle To Horizontal 0.00 ° Initial Temp. 15.6 C Max.Temp. -----
Radius 10.00 m Orientation None
Local Environment Global
Threshold TDU 290
Threshold Temperature 373.15

Results

Noise
Radiation 9.402 kW/m2 Temperature 82.2 C Average Noise 99.8 dB
Concentration 0.00000 mole/mole Local Wind Speed 10.000 m/s Noise 109.8 dB
Time to TDU Limit 14.6 s Time to Temp. Limit Limit Not Reached Noise A (*) 108.5 dB

Noise Spectrum Results

Frequency Noise Noise A (*)


31.3 Hz 73.1 dB 33.7 dB
62.5 Hz 81.3 dB 55.1 dB
125.0 Hz 89.5 dB 73.4 dB
250.0 Hz 98.0 dB 89.4 dB
500.0 Hz 106.5 dB 103.3 dB
1000.0 Hz 103.7 dB 103.7 dB
2000.0 Hz 100.9 dB 102.1 dB
4000.0 Hz 97.8 dB 98.8 dB
8000.0 Hz 93.7 dB 92.6 dB
16000.0 Hz 85.8 dB 79.2 dB

(*) Noise A = Noise weighted for human ear sensitivity

Page 9 of 22
linkedin.com/in/hafifaulianurrahman Thursday, February 15, 2024

2/15/2024 12:36:31 AM Flaresim 2023.2.116 Page 10


Job
Run by
Problem
DataFile D:\Hafif A. N. R\Posting LinkedIn\File Calculations\24. Gas Dispersion Modeling for Flare Stacks Using Flaresim\Gas Dispersion Modeling for Flare Stacks Using Flaresim.fsw
Time 2/15/2024 12:36:31 AM
This Printout Is Not Valid Unless Page 1 Is Attached And Completed

Noise Chart

Time Dependent Curves

Time Temp. TDU Time Temp. TDU


s C (kW/m2)4/3.s s C (kW/m2)4/3.s
0.0 15.6 0.0 10.0 21.3 198.4
20.0 26.6 396.9 30.0 31.5 595.3
40.0 35.9 793.8 50.0 40.0 992.2
60.0 43.7 1190.6 70.0 47.1 1389.1
80.0 50.2 1587.5 90.0 53.0 1786.0
100.0 55.6 1984.4 110.0 58.0 2182.8
120.0 60.1 2381.3 130.0 62.1 2579.7
140.0 63.9 2778.2 150.0 65.5 2976.6
160.0 67.0 3175.0 170.0 68.3 3373.5
180.0 69.6 3571.9 190.0 70.7 3770.4
200.0 71.7 3968.8 210.0 72.7 4167.2
220.0 73.5 4365.7 230.0 74.3 4564.1
240.0 75.0 4762.6 250.0 75.7 4961.0
260.0 76.2 5159.4 270.0 76.8 5357.9
280.0 77.3 5556.3 290.0 77.7 5754.8
300.0 78.1 5953.2 310.0 78.5 6151.6
320.0 78.8 6350.1 330.0 79.1 6548.5
340.0 79.4 6747.0 350.0 79.7 6945.4
360.0 79.9 7143.8 370.0 80.1 7342.3
380.0 80.3 7540.7 390.0 80.5 7739.2
400.0 80.6 7937.6 410.0 80.8 8136.0
420.0 80.9 8334.5 430.0 81.0 8532.9
440.0 81.1 8731.4 450.0 81.2 8929.8
460.0 81.3 9128.2 470.0 81.4 9326.7

Page 10 of 22
linkedin.com/in/hafifaulianurrahman Thursday, February 15, 2024

2/15/2024 12:36:31 AM Flaresim 2023.2.116 Page 11


Job
Run by
Problem
DataFile D:\Hafif A. N. R\Posting LinkedIn\File Calculations\24. Gas Dispersion Modeling for Flare Stacks Using Flaresim\Gas Dispersion Modeling for Flare Stacks Using Flaresim.fsw
Time 2/15/2024 12:36:31 AM
This Printout Is Not Valid Unless Page 1 Is Attached And Completed

Time Temp. TDU Time Temp. TDU


s C (kW/m2)4/3.s s C (kW/m2)4/3.s
480.0 81.5 9525.1 490.0 81.6 9723.6
500.0 81.6 9922.0 510.0 81.7 10120.4
520.0 81.7 10318.9 530.0 81.8 10517.3
540.0 81.8 10715.8 550.0 81.8 10914.2
560.0 81.9 11112.6 570.0 81.9 11311.1
580.0 81.9 11509.5 590.0 82.0 11708.0
600.0 82.0 11906.4 610.0 82.0 12104.8
620.0 82.0 12303.3 630.0 82.1 12501.7
640.0 82.1 12700.2 650.0 82.1 12898.6
660.0 82.1 13097.0 670.0 82.1 13295.5
680.0 82.1 13493.9 690.0 82.1 13692.4
700.0 82.1 13890.8 710.0 82.2 14089.2
720.0 82.2 14287.7 730.0 82.2 14486.1
740.0 82.2 14684.6 750.0 82.2 14883.0
760.0 82.2 15081.4 770.0 82.2 15279.9
780.0 82.2 15478.3 790.0 82.2 15676.8
800.0 82.2 15875.2 810.0 82.2 16073.6
820.0 82.2 16272.1 830.0 82.2 16470.5
840.0 82.2 16669.0 850.0 82.2 16867.4
860.0 82.2 17065.8 870.0 82.2 17264.3
880.0 82.2 17462.7 890.0 82.2 17661.2
900.0 82.2 17859.6

Temperature Chart

Page 11 of 22
linkedin.com/in/hafifaulianurrahman Thursday, February 15, 2024

2/15/2024 12:36:31 AM Flaresim 2023.2.116 Page 12


Job
Run by
Problem
DataFile D:\Hafif A. N. R\Posting LinkedIn\File Calculations\24. Gas Dispersion Modeling for Flare Stacks Using Flaresim\Gas Dispersion Modeling for Flare Stacks Using Flaresim.fsw
Time 2/15/2024 12:36:31 AM
This Printout Is Not Valid Unless Page 1 Is Attached And Completed

TDU Chart

Receptor Grids
Receptor Grid: Grid 1 - Active

Input Data
Location Properties Noise
Orientation Northing-Easting Emissivity 0.700 Noise Basis Noise
Offset 0.00 m Point Absorbtivity 0.700
Axis 1 Northing Area Ratio 2.000
Axis 2 Easting Point Orientation None

Axis information
Northing Minimum -150.00 m Maximum 150.00 m Nbr. of Points 41
Easting Minimum -150.00 m Maximum 150.00 m Nbr. of Points 41

Results

Maximum Radiation
Sizing Limit ----- Find Max. Rad. True Initial Grid Points 11
Radiation 9.591 kW/m2 Northing -5.29 m Easting 0.00 m

Page 12 of 22
linkedin.com/in/hafifaulianurrahman Thursday, February 15, 2024

2/15/2024 12:36:31 AM Flaresim 2023.2.116 Page 13


Job
Run by
Problem
DataFile D:\Hafif A. N. R\Posting LinkedIn\File Calculations\24. Gas Dispersion Modeling for Flare Stacks Using Flaresim\Gas Dispersion Modeling for Flare Stacks Using Flaresim.fsw
Time 2/15/2024 12:36:31 AM
This Printout Is Not Valid Unless Page 1 Is Attached And Completed

Radiation chart

Temperature chart

Page 13 of 22
linkedin.com/in/hafifaulianurrahman Thursday, February 15, 2024

Page 14 of 22
linkedin.com/in/hafifaulianurrahman Thursday, February 15, 2024

2/15/2024 12:36:31 AM Flaresim 2023.2.116 Page 14


Job
Run by
Problem
DataFile D:\Hafif A. N. R\Posting LinkedIn\File Calculations\24. Gas Dispersion Modeling for Flare Stacks Using Flaresim\Gas Dispersion Modeling for Flare Stacks Using Flaresim.fsw
Time 2/15/2024 12:36:31 AM
This Printout Is Not Valid Unless Page 1 Is Attached And Completed

Noise chart

Page 15 of 22
linkedin.com/in/hafifaulianurrahman Thursday, February 15, 2024

2/15/2024 12:36:31 AM Flaresim 2023.2.116 Page 15


Job
Run by
Problem
DataFile D:\Hafif A. N. R\Posting LinkedIn\File Calculations\24. Gas Dispersion Modeling for Flare Stacks Using Flaresim\Gas Dispersion Modeling for Flare Stacks Using Flaresim.fsw
Time 2/15/2024 12:36:31 AM
This Printout Is Not Valid Unless Page 1 Is Attached And Completed

Concentration chart

Receptor Grid: Elevation - Active

Input Data
Location Properties Noise
Orientation Elevation-Northing Emissivity 0.700 Noise Basis Noise
Offset 0.00 m Point Absorbtivity 0.700
Axis 1 Elevation Area Ratio 2.000
Axis 2 Northing Point Orientation None

Axis information
Elevation Minimum 0.00 m Maximum 300.00 m Nbr. of Points 41
Northing Minimum -300.00 m Maximum 100.00 m Nbr. of Points 41

Results

Maximum Radiation
Sizing Limit ----- Find Max. Rad. True Initial Grid Points 11
Radiation 911150327.235 kW/m2 Elevation 31.79 m Northing -5.29 m

Page 16 of 22
linkedin.com/in/hafifaulianurrahman Thursday, February 15, 2024

2/15/2024 12:36:31 AM Flaresim 2023.2.116 Page 16


Job
Run by
Problem
DataFile D:\Hafif A. N. R\Posting LinkedIn\File Calculations\24. Gas Dispersion Modeling for Flare Stacks Using Flaresim\Gas Dispersion Modeling for Flare Stacks Using Flaresim.fsw
Time 2/15/2024 12:36:31 AM
This Printout Is Not Valid Unless Page 1 Is Attached And Completed

Radiation chart

Temperature chart

Page 17 of 22
linkedin.com/in/hafifaulianurrahman Thursday, February 15, 2024

Page 18 of 22
linkedin.com/in/hafifaulianurrahman Thursday, February 15, 2024

2/15/2024 12:36:31 AM Flaresim 2023.2.116 Page 17


Job
Run by
Problem
DataFile D:\Hafif A. N. R\Posting LinkedIn\File Calculations\24. Gas Dispersion Modeling for Flare Stacks Using Flaresim\Gas Dispersion Modeling for Flare Stacks Using Flaresim.fsw
Time 2/15/2024 12:36:31 AM
This Printout Is Not Valid Unless Page 1 Is Attached And Completed

Noise chart

Page 19 of 22
linkedin.com/in/hafifaulianurrahman Thursday, February 15, 2024

2/15/2024 12:36:31 AM Flaresim 2023.2.116 Page 18


Job
Run by
Problem
DataFile D:\Hafif A. N. R\Posting LinkedIn\File Calculations\24. Gas Dispersion Modeling for Flare Stacks Using Flaresim\Gas Dispersion Modeling for Flare Stacks Using Flaresim.fsw
Time 2/15/2024 12:36:31 AM
This Printout Is Not Valid Unless Page 1 Is Attached And Completed

Concentration chart

Gaussian Dispersion
Gaussian Dispersion: H2S Contour - Active

Input Data
Source FlaredFluid Type Contour

Plane height 0.00 m


Northing
Minimum -1000.00 m Maximum 0.00 m Nbr. of Points 51
Easting
Minimum -500.00 m Maximum 500.00 m Nbr. of Points 51

Pollutants
Hydrogen sulphide Active Methane Ignored Ethane Ignored

Page 20 of 22
linkedin.com/in/hafifaulianurrahman Thursday, February 15, 2024

2/15/2024 12:36:31 AM Flaresim 2023.2.116 Page 19


Job
Run by
Problem
DataFile D:\Hafif A. N. R\Posting LinkedIn\File Calculations\24. Gas Dispersion Modeling for Flare Stacks Using Flaresim\Gas Dispersion Modeling for Flare Stacks Using Flaresim.fsw
Time 2/15/2024 12:36:31 AM
This Printout Is Not Valid Unless Page 1 Is Attached And Completed

Pollutant concentration chart for

Gaussian Dispersion: Combustion Emissions - Active

Input Data

Source CombustionGas Type DownwindLine

Plane height 0 Line Origin Origin


Downwind
Minimum 100.00 m Maximum 10000.00 m Nbr. of Points 100

Page 21 of 22
linkedin.com/in/hafifaulianurrahman Thursday, February 15, 2024

2/15/2024 12:36:31 AM Flaresim 2023.2.116 Page 20


Job
Run by
Problem
DataFile D:\Hafif A. N. R\Posting LinkedIn\File Calculations\24. Gas Dispersion Modeling for Flare Stacks Using Flaresim\Gas Dispersion Modeling for Flare Stacks Using Flaresim.fsw
Time 2/15/2024 12:36:31 AM
This Printout Is Not Valid Unless Page 1 Is Attached And Completed

Pollutants
Hydrogen sulphide Ignored Methane Ignored Ethane Ignored
Carbon dioxide Ignored Water Ignored Sulphur dioxide Active
Nitrogen monoxide Active Carbon monoxide Active Methane Active

Downwind Line Pollutant Concentration Chart

Messages
Level Message
Info: Calculations started at 2/15/2024 12:33:20 AM
Info: Calculating base case
Info: Tip Tip 1 : Dispersion - The edge of the jet is interacting with the ground at 2059.0 m.
Info: Point RP_1 : Calculated
Info: Grid Grid 1 : Calculated
Info: Grid Elevation : Calculated
Info: Calculations completed at 12:33:23 AM