You are on page 1of 4

M2 – 5-digit digital panel meter in 96x48 mm (BxH)

Frequency 0.01 Hz to 999.99 kHz / 0.01 Hz to 9.9999 kHz / 0-2.5000 kHz


Connection for Namur, 3-wire NPN/PNP, position survey via
incremental encoder (HTL- or TTL-output)

• red display of -19999…99999 digits (optional green, orange, blue or tricolour display)

• compact installation depth: 70 mm without plug-in terminal

• adjustment via factory default or directly on the sensor signal

• min/max-memory with adjustable permanent display

• 30 additional adjustable supporting points

• display flashing at threshold value exceedance/undercut

• Schmitt-Trigger-Input

• digital frequency filter for contact bounce suppression and interference suppression

• frequency filter with different pulse-duty factor

• zero key for actuation of tara-function /hold-function, display change, setpoint setting, alarm actuator

• flexible alarm system with adjustable delay times

• volume measurement (Totaliser) for frequencies up to 1 kHz (pulse precisely)

• mathematical functions like reciprocal value, square root, squaring and rounding
• constant setting / respectively setpoint setting

• sliding averaging

• brightness control via parameters or front keys


• programming interlock via access code

• protection class IP65 at the front

• plug-in screw terminal

• optional: 2 relay outputs

• optional: 1 independently scalable analog output

• optional: galv. isolated digital input for the triggering of Tara, Hold, display change

• accessories: pc-based configuration-kit PM-TOOL with CD & USB adapter

• on demand: devices for working temperatures of -20°C…60°C or -40°C…70°C

Update 07/09/2016 - m2_frequency_96x48.gb.doc


Errors and omissions excepted.
Page 1
96x48
ORDER NUMBER EUR
(without options)
• Frequency (0.01 Hz to 999.99 kHz)
• Frequency (0.01Hz to 9.9999 kHz for transmitter / 0 to 2.5000 kHz for position survey)

Supply 230 VAC M2-1FR5B.0307.570CD 185,00

• Frequency (0.01 Hz to 999.99 kHz)


• Frequency (0.01Hz to 9.9999 kHz for transmitter / 0 to 2.5000 kHz for position survey)

Supply 10-30 VDC M2-1FR5B.0007.670CD 195,00

Advice: Using Namur sensors with a nominal voltage of approx. 8 V, a sensor supply of 12 VDC needs to be provided.

• Product key options

M 2- 1 F R 5 B. 0 3 0 7. 5 7 0 C D
M 2- 1 F R 5 B. 0 0 0 7. 6 7 0 C D EUR
2 2 relay outputs 33,00
1 Without keypad, operation via PC-Software PM-TOOL 10,00
X Analog output 0/4-20 mA, 0-10 VDC 120,00
2 Sensor supply 10 VDC / 20 mA incl. digital input 55,00
3 Sensor supply 24 VDC / 50 mA incl. digital input 55,00
6 Sensor supply 12 VDC / 50 mA incl. digital input 55,00
K Pulse output max. 10 kHz, incl. sensor supply / incl. digital input 65,00
B Blue 44,00
G Green 10,00
Y Orange 4,00
T Tricolour (Red-Green-Orange)* 30,00
* 230 VAC voltage supply is not available with relay outputs.
Please state physical unit on demand, e.g. U/min.

ORDER NUMBER EUR


• Parameterisation software

PC based configuration software PM-Tool for devices without keypad, PM-TOOL-MUSB4 89,00
for a simple adjustment of standard devices, incl. CD & USB-adapter.
Programming happens via an interface on the back.

Update 07/09/2016 - m2_frequency_96x48.gb.doc Page 2


Errors and omissions excepted.
• Technical data
Dimension Housing B96 x H48 x D70 mm (including plug-in terminal D= 89 mm)
Panel cut-out 92.0+0.8 x 45.0+0.6 mm
Fixing screw elements for insulation thickness up to 3 mm
Housing material PC Polycarbonate, black
Sealing material EPDM, 65 Shore, black
Protection class at the front IP65 standard, back side IP00
Weight approx. 250 g
Connection plug-in terminal; line cross-section up to 2.5 mm2

Display Display 5-digit


Digit height 14 mm
Segment colour red (standard), optional available in green, blue, orange or tricolour (red/green/orange)
Display range -19999 to 99999
Setpoints optical display flashing
Overflow horizontal bars at the top
Underflow horizontal bars at the bottom
Display time 0.1 to 10.0 seconds

Measuring input Signal impulse input, TTL, Namur, 3-wire initiator PNP/NPN
Input resistance Ri at 24 V / 4 kΩ
HTL level >15 V / < 4 V
TTL level >4.6 V / <1.9 V
Input frequency 0.01 Hz…999.99 kHz,
0.01 Hz…9.9999 kHz with rev counter,
0…2.5000 kHz with position recording
Measuring fault 0.05% of measuring range, ± 1 digit

Output Relay with change-over contact 250 V / 5 AAC, 30 V / 5 ADC


Switching cycle 10 * 103 at 5 AAC, 5 ADC ohm resistive burden
10 * 106 mechanically
Separation in accordance with DIN EN 50178 / Specifications in accordance with DIN EN 60255

Pulse output max. 10 kHz


Analog output 0-10 VDC/ burden ≥ 10 kΩ, 0/4-20 mA burden ≤ 500 Ω, 16 bit
Sensor supply 24 VDC / 50 mA
10 VDC / 20 mA

Digital input Input galv. isolated <2.4 OFF; >10 V ON; max. 30 VDC, Ri at ~ 5 kΩ

Power pack Supply 230 VAC 50/60 Hz ±10 % (max. 10 VA)


10-30 VDC, galvanic isolated (max. 4 VA)

Memory EEPROM Data life ≥ 100 years at 25°C

Ambient Working temperature 0 to +60°C


conditions Storing temperature -20 to +80°C
Climatic density relative humidity 0-85% on years average without dew

CE-sign Conformity to directive 2014/30/EU

EMV EN 61326, EN 55011

Safety According to low voltage directive 2014/35/EU, EN 61010; EN 60664-1


standard

Housing:

3,0

M2
Se
alin
g
48,0

l
ina
term
,0 ion
89 ect
conn
l.
inc
Gap for physical dimension
pth
n de
atio
nstall
I

Update 07/09/2016 - m2_frequency_96x48.gb.doc Page 3


Errors and omissions excepted.
• Order key

M 2- 1 F R 5 B. 0 3 0 7. 6 7 0 C D

Basic type M-Line Dimension


D physical unit
Installation depth
89 mm (incl. plug-in terminal) 2 Version
C C
Housing size
96x48x70 mm (BxHxD) 1 Switching points
0 no switching point
Display type 2 2 relay outputs
Frequency F
Protection class
Display colours 1 without keypad, operation via PM-TOOL
Blue B 7 IP65 / plug-in terminal
Green G
Red R Supply voltage
Red/Green/Orange T 4 115 VAC
Orange Y 5 230 VAC
6 10-30 VDC galv. isolated
Number of digits
5-digit 5 Measuring input
7 Pulse, Namur, 3-wire PNP/NPN
Digit height
14 mm B Analog output
0 without
Digital input X 0-10 VDC, 0/4-20 mA
without 0
1x digital input I Sensor supply
0 without
2 10 VD / 20 mA, incl. digital input
3 24 VDC / 50 mA, incl. digital input
6 12 VDC / 50 mA, incl. digital input
K 24 VDC / 50 mA, incl. digital input
and pulse output (10 kHz)

Update 07/09/2016 - m2_frequency_96x48.gb.doc Page 4