Professional Documents
Culture Documents
From : The air quality in ventilation installation - practical guidelines CETIAT 2004
Airopac (panel)
Class: M5-M6, F7-F9
Filter media: Glass fibre
Frame: Box type or 25mm header / metal, MDF
Standard dim: WxH= 287 (305), 490, 592 (610), 892,...
D= 135, 150, 292
Absolute/Close pleat
Class: E11, H13, H14
Frame: MDF, Galvanized steel
Standard dim: WxH= 305, 457, 535, 575, 610, 762, 915, 1220, 1525, 1830,..
D= 78, 150, 292
Megalam
Class: E11, H13-H14, U15-U17
Frame: Aluminium
Standard dim: WxH= 305, 457, 535, 575, 610, 762, 915, 1220, 1525, 1830,..
D= 66, 90, 110
Different versions:
- Special dimensions
- Gel filters
- Special housings
• 350°C 1FRK/Termikfil
Sterilization & Depyrogenation
Class: H13
tunnels
Frame: Stainless steel/composite ceramic
Gasket/sealant: Glass fiber, ceramic
Standard dim: WxH= 305, 457, 610, 762, 915, ...
D= 84,150, 292
• 120°C Sofilair/Absolute
Granulation dryers Class: H13
Frame: Galvanized steel
Gasket/sealant: PU, EPDM
Standard dim: WxH= 305, 457, 610, 762, 915, ...
< 70°C - 80°C D= 150, 292
HVAC
Filter housings:
- Safe change
- Terminal
- Exhaust
- Duct
Prefilters (G4-F9):
- Panel
- Bag
- V-bank
EPA/HEPA/ULPA filters:
3
1
Clean air solutions
Containment products-filter housings
Pharmaseal/Camsafe wall
- Exhaust filter housing
- Wall mounted
- Hygienic filter change
through a bag
What is it ?
✓ Dirty air in
CamGrid system
• Dry or gel mounting system for HEPA filters
• Modular aluminium element
• Simple and fast istallation
Configuration
• Modern ART Design – optimisied for interiors
• Extrem Silent CamCleaner through Fusion Material + Design
• Easyweight construction
• Filterclass H13 + Molecular
• Controlpanel with LED incl. fanspeed and Filterchange
• Airvolume max. 300m³/h (spprox 80 m2 normal space)
Tested, certified to
Microbial inert ISO 846
(Micro-organisms actions on polymers’s evaluation)
Tested, certified to
VDI 6022 (Hygiene conditions for ventilation and air-
Hygienic
conditionning – Materials can’t be used as nutrient for
micro-organisms) „..The principle underlying this Regulation is that any material
or article intended to come into contact directly or
Tested, certified to indirectly with food must be sufficiently inert to preclude substances
Food contact from being transferred to food in quantities
EC 1935:2004 large enough to endanger human health or to bring about
an unacceptable change in the composition of the food or
a deterioration in its organoleptic properties...“
•This means that the terminal filtration will be ”displaced” from the air terminal devices in
the room to filter housings in the technical space. The filter housing must be a tight
solution with the scanable option as required by GMPs (Last HEPA stage).
•Customers are not comfortable with current techniques to scan ducted HEPA : intrusive,
uneasy, hard to repeat.
•End users are requesting an easy solution of Hepa Filtration Housings with scanning
section.
•The CamCube AS is Camfil’s newest ducted filter housing designed acc. to the
requirements from the Life Science industry.
Inspection Eyes
Specific clamping
Based on the requirements GMP System
Easy repeatable Measurements
No need to open the duct for measuring
Clean air solutions
Clean air solutions
Absolute D-Pyro
8 4
No outgassing