Di2 SECTIONAL VALVE SECTIONAL VALVE J D12 QUICK REFERENCE GUIDE GENERAL SPECIFICATION D9 DSM DVSIO0 D4 D6 Dis Di2 DVS20 D20 D25 p40 Working sections number peor 2 i re ie GB) ie re re 0 cacurr Peraie . . + © © © Mmye + - Series ._ 7. + e o oo oo. ‘Tandem :-. = - 2 oe . Parallel creut stroke (mm) 6 5 6 6 7 7 98 95 95 12 15 Series circuit stroke (me) 6 5 6 6 5 7 65 65 85 Float spool extra stroke (mm) 5 5 5 55 6 7 7 7 7 95 10 ‘Spoals pitch (mmm) st 383540 GSS RATED FLOW Max recommended flow rate (Vin) 35 55 45 80100150 480-250 250380 700 Max recommended flow rate (GPM) so 15 12 AB? 100 385 RATED PRESSURE Max working pressure (bar) 350 350 350 350350350 BBO) 250 350 350350 Max working pressure (PSI) sooo S000 5000 som Saco 5000 $000 4000 S000 5000 5000, OPTION CHART 9 DSM pvsi0 D4 D6 p16 D12 DVS20 D20 025 p40 Direct acting pressure rele valve “oe ee ‘ Pilot operated pressure reli valve . ec 2 stage pilot operated relief valve : ele > “<< © Externally pllted valve _. . ee a Solenoid dump valve (12 Vee) _. ey Solenoid dump velve (26 Vde) o . » oe ene Main antcavitation check valve : oe ©Mme + © ‘amping valve c= 8 ‘SPOOL ACTUATION Manual control 7 + )* «© + Mme « + without lever o «lw eo +.M™ee «+ e 90° joystick control . Hydraulic control a7 6 6 + + — . « «© © Direct electric control (12-24 Ve) . . ‘SPOOL RETURN ACTION Spring return 2 + . =. 2 Os ss = Detent in Ain 8 =in AB Cn Detent in 4 position . . . © o © Me + + Arrangement for dual contr << a . Hydraulic load limit oo a a Pneumatic control ON - OFF ._ . © © © fm. Proportional pneumatic control . . « + oMme - Electrica load limit as i Eletrohydauiie contol ON-OFF (12-24 Ve) ._. +. © oo. Electrohydraulc control PROP. (12-24 Vdc) ._ . © « of. e lectropneumatic control (12-24 Vdc) ._ oe e oe . AUXILIARY VALVES Antishock valve 7. « « « +My. « « Anticavitation valve oo. « « « +» Mee oo e Combined valve soe oe eee soe Pilot combined valve . ee ee 12 [J SECTIONAL VALVE GENERAL INDEX 4) General specifications Standard working conditions Fluid options 51) Order example ‘Standard thread Thread codes Tie-rod kit classification Painting 7) Dimensions 8 | Typical curves Pressure drop (P - 7) Pressure drop (P -A/8) Pressure drop (A/B - T) Direct relief valve curve ‘Combined vaive curve Antishock valve curve ‘Anticavitation check valve curve 10") Inlet Section Order example Inlet side classification Valve identification Valve arrangement {Inlet position and available thread type 33) Working section Order example Spool identification ‘Spool actuation classification for manual control ‘Spool actuation classification for hydraulic control Spool return action classification - Spring load values Work section identification ‘Auxiliary valves identification 25)/| Intermediate inlet section Order example Intermediate inlet section classification Valve identification on intermediate inlet section Valve arrangement on intermediate inlet section Inlet position and available thread type 28) Intermediate outlet section Order example Intermediate outlet section classification Inlet position and available thread type (for BF intermediate) Inlet position and a (for BG intermediate) 32) Outlet section (version 1 outlet) Order example '32)]| Outlet section (HPCO version outlet) ‘Order example - HPCO version outlet ‘Outlet with single tank classification ‘utet with two tanks classification Carry-over connection (HPCO) 361/112 Spare parts list Gasket kits 39) Installation 41 General conditions and patents ble thread type SECTIONAL VALVE J D12 Ease Description ‘Ambient operating temperature range Kinematic viscosity range ‘Max contamination level Recommended filtration level Internal filter (on electroproportional valves pilot line) ‘Standard working conditions value 40°C / +60°C 10 + 300 cst 9 (NAS 1638) - 20/18/15 (ISO 4406:1999) bio > 75 (IS0 16889:2008) 30 um All information and diagrams in this catalogue refer to @ mineral base cil VG46 at 50°C temperature (B2 cSt kinematic viscosity) ‘Types of fluid (according to 150 6743/4) and Solutions Mineral Oil HL, HM (or HLP acc. to DIN 51524) Cl in water emulsions HFA ‘Water in oll emulsions HFB Polyalycol-based aqueous solution HFC Fluid options Temperature (°C) = ze Compatible gasket 25 +80 NBR 45 455 NBR +5 +55 NBR 10 +60 NBR For special applications and different fluids, please call our Technical Department. oon 12 J] SECTIONAL VALVE Ces EE EET EN TPE: 1D12: product type 74: working section number 1) INLET ARRANGEMENT: pag. 10 IR 009 Inlet side and valve type 150 setting (bar) AGos Inlet position and available thread type 2) WORK SECTION ARRANGEMENT: pag. 13 woo1a spool type H101 spool actuation type FOO1A spool return action type RP GOS type and thread section 01 PA 100 auxiliary valve (port A) 05 PB auxiliary valve (port B) 3) OUTLET ARRANGEMENT: pag. 32 — . _# D outlet type AGos ‘outlet position and available thread type Ordering row 2 must be repeated for every work section Standard thread ‘The connection ports size Is indicated by an ordering code common for all Hydrocontrol products. Following table shows all available connections; for ordering code refer to table on page 40. Ports ‘BSP (150-228) Code _UN-UNF (IS0-725) Code METRIC (IS0-262) Code Inlet Port (P) G34-G1 GO5-Gd6—1'1/16-12UNF OS 3/4" (MA)- 3/4" (UNC) S03-S04 Ports (AB) G34-G1 GOS-Gos "1/16 - 12 UNF UOS3/4"(MA)- 3/4" (UNC) S03-S04 ‘utiet (1) - carry over (HPO) 1 os 516-12 UNF UO6 _3/4"(MA) - 3/4" (UNC) $03-S04 Hydraulic Pilot ous oz 9ns"-18UNF —_vo2. Pneumatic Pilot ous - PTF 1/827 SECTIONAL VALVE J D12 Tie-rod kit classification (appendix A”) Tle rod kit allows the correct assembly of sectional valves. Tie rod’s length depends on the number of sections; each valve is assembled with tle rod kits including a tie rod, two nuts and two washers. 012 requires 4 tle-rod kits. The rod kit Order Code Lenght (mm) Clamping Torque (Nm) biz 300107001 208 Diz 300107002 264 piz/3 300107003 320 pi2/4 300107004 376 pizs 300107005, 432 piz/6 300107006 488 P D127 300107007 544 p28 300107008 600 piz/9 300107009 656 12/10 300107010 m2 piz/it 300107011 768 piz/i2 300107012 826 (On request, all Hydracontrol valves can be delivered painted (RAL 9005 black primer) Order example of D12/1 painted: Di27/ 1R 009 150 A Gos \WOO1A H101 FOOIA RP GOS 01 PA 100 05 PB TA G06 Po06/1 N10 The painting Is indicated with the following value: 006 - /1- NiO U color black fection number Painted Quantity Painting 112 J] SECTIONAL VALVE wee AAR Bw Bw Pw fo oe x (mm) 162218 274 330306442 ADB SSA GIOsG—S 722778 ¥ (mm 183239295 351-407 «463.519.575.643 799 Weights (ka) 1A 28536 41,2 458 554 64 71,6 79,2 857 98,5102 SECTIONAL VALVE J D12 = TYPICAL CURVES Indicated values have been tested with standard sectional valve and WOO1A spool. Pressure drop (P - T) at. 55 Pressure drop (A/B -T) ‘Setting ranges type pressure (bar) A 0-40 8 ai - 180 c 181 - 250 D 251 - 350, D12 [j SECTIONAL VALVE ene Indicated values have been tested with standard sectional valve and WOO1A spocl. Antishock valve curve _#. ae Setting ranges ed pressure (bar) ae fyPe at full ow at min. flow es A 70-350 70-A/ 120-0 oe B 151-230 121-A/ 200-A 0] c 231-280 © -201-A/ 250-A le D 281-350 251A 350-A “ly Combined valve curve a. ae Setting ranges oS = pressure (bar) me FE eH fyPe at full ow miele et A 30-95 -30-A/ 65-A are B 96-350 71-A/ 120-0 08 c 151-260 121-A/ 230-A Aig D 261-350 231-A/ 350-4 .« = wy aa ae el Anticavitation check valve curve IR 009 150 2. AGOS Rif, Code 1 009 010 012 013 019 020 AGos Gos AUOs cu0s As03 css SECTIONAL VALVE J D12 aac Order example Inlet side classification valve arrangement: setting (ber) Inlet position and available thread type Description Page ‘Sectional valve with right inet section i, ‘Sectional valve with left inet section Pilot operated pressure relief valve Pilot operated pressure relief valve and Main anticavitation check valve Pilot operated pressure relief valve and Solenold dump valve 12 Vde Pilot operated pressure relief valve and Solenoid dump valve 24 Vac Without valves Main anticavitation check valve 2 Upper inlet (thread G 3/4) Central side inlet (thread G 3/4) Upper inlet (thread 1°1/16-12 UNF) Central side inlet (thread 1°1/16-12 UNF) Upper inlet (thread SAE 3000 3/4” MA) Central side inlet (thread SAE 3000 3/4” MA) NOTE: when ordering a relief valve itis necessary to specify factory setting (example 150). [oo 112 J] SECTIONAL VALVE Inlet side classifications ‘Sectional valve with right inlet section ‘Sectional vaive with right inlet section “EEL EL Es we ee IR 1 Valve identification type schema tayout_— description type schema ——tayout_———_—eserption # Plot operated exteraly 2) ue pressure piloted. a rete valve valve > oe feletvave ay Plunge 12 Vde = wan solenois 4 anveavitaton 8 ump vaive check vave 3 vse : 2 stage pilot = Plug with te operated relief 11. pressure-gauge T valve connection Valve arrangement Ener 009 Combination valve 2A Pressure relief valve In port A 3B Relief valve plugged in port B ‘The code identifies: with a number, the type of valve; with a letter its position ‘on the inlet section. (A) = spool action side (B) = spool return action side @ NOTE: when ordering 9 main relief valve itis necessary to specify setting eo SECTIONAL VALVE J D12 Valve type on port 8 vawve - comammaton me SH Wp Wey “ey MH INLET SECTION 4 5 6 7 8 i ep, 2 009 010 on 012 013016 Ce 3 018 019 020 028022023 024027 q 4 029 030 031 032 033 «034 «037 6 017 04s 7 054 055 Valve type on port A 8 061 062 Se 11 oss NOTE: Valve combinations 021, and 038 requir. jouble setting (see example). Order example for inlet section: IR 038 200*280 A GOS 038 valve combination 200*380 double range setting (bar) Inlet combination and thread available Acos comades) 8.605 “gem it ao (wesc 8.606 “macnn e508 coveas See no sjemay 8 803 ace aaa core saeson serve) B SOM neem oot Sores 63/3), D.GOS romana “ cos Cenra site niet ITE cM patemegugecmetn ct (thread G 1) ce (ewead Firtes2 une) PUOS some us GS coreorsie uno yemay | 2 S03 remeron see coveao si sno sno) $04 scrum fe 12 J] SECTIONAL VALVE Rees Order example: A 1, woot spool type 2. Mion ‘spool actuation type 3. FOOIA ‘spool return action type 4, RPGOS section and thread type 5, 01 PA100 auxiliaty valve (port A - handle side) 6 05 PB auxiliaty valve (port 8 - cap side) Rit, Code Description Page 3, Woox 3 positions double-acting uw woo2 3 positions double-acting A-B to tank 101 Unprotected lever 2 Hoos hydraulic actuation * 3 Foosa 3 positions spring-centred spool (spring A) an Fo02A 3 positions spring-centred spool detent in A and B (spring A) RP Gos Parallel circuit (G 3/4) 4 RPUOS Parallel circult (1"1/16-12 UNF) 23 RS Gos Series circuit (G 3/4) RS UOS Series circuit (1"1/16-12 UNF) = O1PA100 ‘Antishock valve (port A) 05 PA Prearrangement for auxiliary valve (port A) 24 6 oLPB 100 ‘Antishock valve (port B) os rearrangement for auxiliary valve (port B) (*) Leave out the spool return action code when choosing HOOS. ‘Sections designed to house auxiliary valve option require double choice on work ports A end B. Always indicate setting value when using antishock and combined valve: 01 PA (100) - 03 PA (100) 13 Jom woo1 A 310 biti: : 10 woit wo1s SECTIONAL VALVE J D12 Spool identification order example of spool: W001 A 310 ‘spool schema 3 positions double-acting spool type standard spool restricted service ports restriction on diameter (0,10 mm in A and B) 3 positions double-acting 3 positions double-acting A and B to tank 3 positions double-acting A to tank 8 blocked 3pm citleacny Aedes ork ae 3 positions single - acting on A 3 positions single - acting on B 3 positions double-acting with anticavitation valves 3 positions double-acting switch port closed (A - B blocked) 3 positions double-acting switch port closed (A - 8 to tank) cy 4 positions double-acting with float in the 4" position 3 positions double-acting regenerative i 3 positions double-acting series EIT Ey 3 positions double-acting series A and 8 to tank EEE oon 14 112 J] SECTIONAL VALVE spools with restricted service ports code circuit, restriction on diameter (mm) section (mm) hydraulic schema m0 0 ABINT auto 3s ARM x10 AT ato 345 t ° yao BINT ato 3s { Ape poo! type available STANDARD METERED cove a 8 woos woot woos woo2 woo2a woo2s woo3 woo3a woo3e woos woosa woos woos woosa wooss woos woo6a woos woos woosa woo9e wo10 wo10a wou wostA wo12 wor2a wo13 wor3a wos worsa wos wos nore: = W012, W013, spools need a special machining on the valve body. = W015, W016, spools need RS type body. Float spool (WW012) need special detent kit (F005), + Regenerative spool (W013) need special return spring kits. - Different spools are available on request. Plaese contact our Sales department for more information, 15 Jom code Hi01 H102 ne Hi SECTIONAL VALVE J D12 Spool actuation classification for manual control description configuration Control without lever Unprotected lever Unprotected lever rotated 180° Spool actuation classification for Hydraulic control description dimensions configuration Hydraulic actuation with side ports as pore = 6 14 LUNE ports = 9/16:18 UNE Wydauic actuation | Naveen gD src cause ot a BSP ports = 6.14 LUNE ports = 9/168 UNE Hydraulic pilot control curve “The diagram shows the spool stroke as a function of the pressure operating. side cmt Pe oon a6 12 J] SECTIONAL VALVE ‘Spool return action classification - Springs load values ‘Spool return kits have three different sprong types; following the codes depending on spring loads. Spring type Code standard spring) B (soft spring) (heavy soring) _rcacing |") Preloading 151N 128N 253.N Endof stroke 186.4 N 141.2N 430.6 N ‘Spool return action identification example frases 29 code FOO1A O01 Foo1c & 7 Spool return action classification code description schema dimensions ‘configuration FOo1A 3 positions a FOO3B spring-centred spool Fooic 3 positions FOOZA spring-centred spool detent in A and B 3 positions FOO3A spring-centred spool detent in A 3 positions FOO4A _spring-centred spool detent in B 4 positions spring-centred spool FOOSA detent in 4" position (only for W012 spool) poian! 3 positions spring-centred spool FO43B prearrangement — ose dual command a code Fo21A F136A FA26A F127A description Pneumatic control ON - OFF Pneumatic contral ON - OFF rotated 180° Proportional Pneumatic contro! Proportional Pneumatic control rotated 180° Pneumatic control ON - OFF Pneumatic control ON - OFF rotated 180° Proportional Pneumatic control Proportional Pneumatic control rotated 180° SECTIONAL VALVE J D12 Pneumatic control classification schema dimensions configuration anebA roprina contr wi ort NPT: 8.27 Proportional pneumatic control curve ‘The diagram shows the spool stroke as a function of the pneumatic pressure operating. ‘soe 8) ‘0: Oo el D12 Jf SECTIONAL VALVE Electrohydraulic control specifications Operating temperature range | -20°C/ +80°C Max inlet pressure 350 bar Reduced pressure 16 bar Back pressure on (T) 3 bar Filtering degree 25 y assoluti Racommended pilot pipe size 9 6 mm-G 1/4 Electrohydraulic ON-OFF control Electrohydraulic PROPORTIONAL contr with fixed pressure reducing vaive with fixed pressure reducing valve eer mim oer T F1600=F1610 Fisoo-F1sio=F1s20-F1520 F2600=F2610 F2500-F2510-F2520~F2520 Proportional control kit, mechanically retrooperated, allows the maximum precision of positioning, limiting the hyste- resis. The control is operated with PWM control of the current. PWM frequency suggest: 60-80 Hz regolation currents Nominal voltage (V)__Resistance R,, (Ohm) Current min (A) Current max (A) 12 vde 37 09 17 24 vac 15,5 0,45, 0,85 Electrohydraulic control classification code description dimensions configuration 3 positions electronydraulic control ON - OFF 12 Vde F1600 3 positions electrohydraulic control ON - OFF 24 Vde F1610 3 positions electrohydraulic ‘control PROPORTIONAL 12 Vde 3 positions electrohydraulie 2610) control PROPORTIONAL 24 Vde Electrohydraulic ON-OFF control is stackable with electrohydraulic PROPORTIONAL control (F2600 = F2610) Control kit already includes ortifice to make spool displacement more gradual. 19 Jom SECTIONAL VALVE J D12 Electrohydraulic control with fixed pressure reducing valve classification code description configuration lectrohydraullc control ON - OFF F1500 rced pressure reducing valve) PT inlet side (12 vdc) Electrohydraulic control ON - OFF FA510 (axed pressure reducing valve) P~T Inlet side (24 wée) — Electrohydraulle control PROPORTIONAL (fixed pressure reducing valve) PT inlet side (12 vée) = Electrohydrauile control PROPORTIONAL (fixed pressure reducing valve) PT inlet side (24 vdc) lectrohydraulic control ON - OFF FI520 (nsed pressure reducing valve) P inlet -T outlet (12 wae) —_— Electrohydrauile control ON - OFF (fixed pressure reducing valve) P inlet - T outlet (24 vée) poate Electrohydraulic control PROPORTIONAL (xed pressure reducing valve) P inlet ~T outiet (12 vde) Electrohydrauiic control PROPORTIONAL 1 F2530 (hxed pressure reducing valve) P init -T outlet (24 wae) npr mien Control tie rod assembly The lenght of the control tie rod, will change depending on the section numbers; in this way it will be easy to install In the right way the sections and avold any misassembly. Each kit is composed by 2 tie rods, 2 plugs, 2 connection ports and spacers according to the section number. NOTE: the control tie rod kit has always to be oedered separately. Reducing valve, combined with electrohydraulic control kit has to be calculated as a normal working section. ORDER EXAMPI Complete valves with 3 sections F1600 requires a complete tle-rod kit /3. Complete valves with 2 sections F1600 and 1 section with 1500 (reducing valve) requires a complete tie-roc kit /4.. 12 J] SECTIONAL VALVE Order code fixed pressure reducing valve: 1915000303 = reducing valve for 8SP ports 1915000312 = reducing valve for UNF ports Order code for control tie rod (BSP): Order code for control tie rod (UNF): 320103001 = control tie rod /1 320103026 = control tie rod /1 320107003 = control tie rod /2 320107026 = control tie rod /2 320107002 = control tie rod /3 320107027 = control tie rod /3 320107003 = control tie rod /4 320107028 = control te rod /4 320107004 = control tie rod /5 320107029 = control tie rod /5 ‘320107005 = control te rod /6 320107030 = control tie rod /6 320107006 = control tie rod /7 320107031 320107007 = control tie rod /8 320107032 320107008 = control tie rod /9 320107033 = control tie rod /9 Electropneumatic control classification code description dimensions configuration 3 positions electropneumatic FO620 control ON-OFF intmum (12 vde)7W-0,58A ‘working 3 positions re ‘lectropneumatic 5 ber FO630 control ON-OFF L (24 vde) 7 W = 0,29 A Control tie rod assembly ‘The lenght of the control tie rod, will change depending on the section numbers; in this way it wil be easy to install in the right way the sections and avoid any misassembly. Each kit Is composed by 1 tie rod and 2 plugs NOTE: the control tie rod kit has always to be oedered separately. Order code for control tie rod (BSP): Order code for control tie rod (UNF): 320107014 = control tie rod /1 320107039 = control tie rod /1 320107045 = control tie rod /2 320107040 = control tie rod /2 320107036 = control tie rod /3 320107041 = control tie rod /3 320107017 = control tie rod /4 320107042 = control tie rod /4 320107018 = control tie rod /5 320107043 = control tie rod /5 320107019 = control tie rod /6 320107044 = control tie rod /6 320107020 320107021. control tle rod /7 320107045 control tle rod /8 320107046 control tie rod /7 control te rod /8 at Joe SECTIONAL VALVE J D12 Compatibility table D12 [J SECTIONAL VALVE Work section identification RP.GOS RP GOS RP UOS RP S03 RP Soa working section type Parallel circuit section When the spool is operated it intercepts the by-pass gallery by diverting the flow of oil to service port A or B. If two ‘or more spools are actuated at the same time, the oil will power the service port that has the lower load; by throttling the spools, the flow of oll can be divided between two or more service ports. Series ireuit section \When the spoo! is operated it intercepts the suitch gallery by diverting the flow of oll to service port A or B. The oll that flows. back from the actuator Is carried to the switch gallery thus making It available to the service ports downstream from the series section. The pressure drop downstream is added to the pressure drop of the section itself. 23 Joe 01 PA 02 PA 04 PA description schema Antishock st te (port A) ‘Anticavitation “aie i (port A) Combined valve (port a) Pllotcombines valve ify (port A) ae Prearrangement for auxiliary valve BA (port A) description schema ‘Antishock vane a (port A) ‘Anticavitation valve (port a) Combined i valve j (port a) Pilot combined valve hy (port A) Prearrangement for auxiliary valve AA (port A) type at full flow SF | SP A SFE gy % sonfiguration type atfullflow type A B c > s) 2%333% SECTIONAL VALVE J D12 Auxiliary valve identification setting range (bar) type at min. flow 70/150 151/230 231 / 280 281 / 350 30/95 96 / 150 151/260 261 / 350 50/420 A ooo ooo 70-A / 120-A 121-A/ 200-8 201-A / 250-A 251-A/ 350-A 30-A/ 65-A 66-4 / 120-A 321-0 / 230-0 31-A/ 350-A 50-A / 420-A, setting range (bar) 70/150 151 / 230 231 / 280 281 / 350 30/95 96 / 150 151 / 260 261 / 350 50/420 A vo ooa> at min. flow 70-A J 120-A 121-A/ 200-8 201-A/ 250-A 251-A/ 350-A 30-A/ 65-A 66-A/ 120-0 121-A/ 230-0 231-A / 350-A 50-A/ 420-A Auxiliary valve - Setting range Sections designed to house auxiliary valve option require double choise on work ports A and B. Always indicate setting value when using antishock valve: (01 PA (120) tting at full flow 01 PA (120-A) = setting at min. flow D12 [J SECTIONAL VALVE cnn neo BE 1. 009, 150 2. AGOS Rif, Code BE ave 008 010 019 020 AGos Auos ON. Order example pce | oo | iso | aces | valve arrangement setting (bar); when ordering a main relief valve itis necessary to specify setting — Inlet position and available thread type Description Page Intermediate inlet section Intermediate inlet section with pressure relief valve 26 Pilot operated pressure relief valve Pilot operated pressure relief vaive and Main anticavitation check valve ‘without valves 7 Main anticavitation check valve Upper inlet (thread G 3/4) Upper inlet (thread 1°1/16-12 UNF) NOTE: when ordering a relief valve itis necessary to specify factory setting (example 150). ‘= = omit the code for inlet positioning and thread 25 Joe ‘The intermediate SECTIONAL VALVE J D12 Intermediate inlet section classifications Intermediate inlet type 4 & Inlet section is driven by two Intermediate Inlet section pumps (P + Pt). The downstream elements can be set toa lower pressure than the upstream ones by adjusting the pressure relief valve of the intermediate section in question. BV qa IF e Intermediate inlet section with pressure relief viaive ‘The intermediate inlet section and the elements are driven by @ single pump (P). The downstream elements can be set to @ lower pressure than the upstream ones by adjusting the pressure relief vaive of the intermediate section in question. type ty BE ana 7 Se Valve identification on intermediate inlet section “a i pressure-gauge 12 Jf SECTIONAL VALVE Valve arrangement on intermediate inlet section ‘Com nes) 09 Combination valve 2A Pressure relief valve in port A 3B Relief valve plugged in port B ‘The code identifies: with a number, the type of vaive; with a letter its posi- tion on the inlet section. (A) = spool action side (@) = spool return action side jg NOTE: when ordering a main relief valve itis necessa- ry to specity setting Valve type on port B valve comsmaronn my TH VW Ce ms iw Ge INLET SECTION em, 2 009 010 016 So 3 018 019 020 027 & 4 029 030 type on port A val Inlet position and available thread type Inlet combination and thread available AGOS Upper inlet (P1) AuOs 27 Je SECTIONAL VALVE J D12 Complete configuration samples for D12/2 with intermediate inlet section (BE) 1R 009 150 A Gos... sae Right inlet section unit section Intermediate inet section WOO1A H101 FOOIA RP G0S........ Working section BE 009 120 A G05 wnrsnnsnnnnnEntermediate inlet section WOOIA H101 FOOLA RP GOS....... Working section TIA G06, Outlet section Working section Inet secon ‘Complete configuration sampli for D12/2 with intermediate Inlet section (BV) IR 009 150 A G05... -»» Right inlet section WOOIA H101 FOIA RP G0S........ Working section BV 009 120 {Intermediate inlet section WOOLA H101 FOOZA RP GOS........ Working section TIA Gos, Outlet section 12 J] SECTIONAL VALVE Ps nk ea Order example BF inlet side 1. AGO6 _ inlet position and available thread type Rif, Code Type Description Page DBF Intermediate outlet section with single tank return BG Intermediate outlet section with two tank returns AGoS Upper outlet (thread G 1) Auos Upper outlet (thread 1”5/16-12 UNF) GGO6 for _Front outlet side A (thread G 1) ry GUOs BF _Front outlet side A (thread 1°5/16-12 UNF) 1 HG06 Rear outlet side B (thread G 1) Huos Rear outlet side B (thread 1”5/16-12 UNF) 3G0G for __Upper outlet HPCO - front side A and rear side B toT (thread G 1) 3U06 «BG _Upper outlet HPCO-tront side A and rear side B to T (thread 1"5/16-12 UNF) 29 Je SECTIONAL VALVE J D12 Intermediate outlet section classifications intermediate outlet type Intermediate outlet section with single tank return Intermediate outlet section with two tank returns ‘The section in question allows the flow of oil of the two pumps to be piped in two outlets: HPCO for powering ano- ther directional control valve, T for discharge of the work ports. In order to obtain this, the two T need to be linked. Outlet combination and thread available ae AGO6 carer OF outlet (T) ‘AU06 6 G06 salar ut a side A(T) GU06 (H GOG arate paar oe ee side B (T) nv06 31G06 Ju06 12 |] SECTIONAL VALVE Complete configuration samples for D12/2 with intermediate outlet section (BF) Intermediate out section IR 009 150 A Gos. Right inlet section Inet secson ‘WOOLA H101 FOOIA RP Gos. Working section ‘Intermediate outlet section ‘WOOLA Hi01 FOOIA RP GOS........ Working section 11.009 150A GOs... Left inlet section ering section et section ‘Complete configuration samples for D12/2 with intermediate oulet section (BG) IR 009 150 A GOS... Right inlet section ‘WOOLA H101 FOOIA RP GOS........ Working section BG 3606... ‘Intermediate outlet section 'WOOLA Hi01 FOOLA RP GOS........ Working section 11.009 150A GOS... Left inlet section a1 Joe SECTIONAL VALVE J D12 SCENT) order example rs 1, 72 outlet section type 2, AGO6 outlet position and available thread type Rif, Code Description Page > Outlet section with single return (T) right-side inlet (P) ™* (Outlet section with single return (T) left-side inlet (P) AGos Upper outlet (thread G 1 Auos Upper outlet (thread 1°5/16-12 UNF) Aso3 Upper outlet (thread SAE 3000 - 3/4°MA) a 2 Aso4 Upper outlet (thread SAE 3000 - 3/4”UNC) cos Central outlet (thread G 1 cuos Central outlet (thread 1°5/16-12 UNF) css Central outlet (thread SAE 3000 - 3/4°MA) cso4 Central outlet (thread SAE 3000 - 3/4"UNC) Ca CC a) Order example - HPCO version Outlet Eo Outlet (HPCO) 1, TM outlet section type Outlet (1) A iy g 2. MGO6 outlet postion and avaliable thread type. ey, Conic pia Rif, Code Description Page .o™ ‘Outlet section with two return (T-HPCO) right-side inlet (P) ™ Outlet section with two return (T-HPCO) left-side inlet (P) M G06 HPCO upper outlet T (tank) rear outlet side 8 (thread G 1) Mu06 HPCO upper outlet T (tank) rear outlet side B (thread 175/16-12 UNF) Ms03 HPCO upper outlet T (tank) rear outlet side B (thread SAE 3000 - 3/4°MA) 36 Mso4 HPCO upper outlet T (tank) rear outlet side B (thread SAE 3000 - 3/4°UNC) Nos HPCO upper outlet T (tank) front outlet side A (thread G 1) Nuos HPCO upper outlet T (tank) front outlet side A (thread 1°5/16-12 UNF) Nos HPCO upper outlet T (tank) front outiet side A (thread SAE 3000 - 3/4°MA) Nsoa HPCO upper outlet T (tank) front outlet side A (thread SAE 3000 - 3/4°UNC) Ie 12 J] SECTIONAL VALVE Outlet with single tank classification AGS Aus Aso3 Aso4 G06 cuo6s cso3 cso4 F G06 Fu06 cos Gus $03 Gso4 G06 Hus H S03 Hso4 outlet identification Outlet section with single return (T) right-side inlet (P) ™ Outlet section with single raturn (T) left-side inlet (P) i i | fa Upper outlet head G 1) Upper outlet (thread 1°5/36-12 UNF) Upper outlet (thread SAE 3000 = 3/4" HA) Upper outlet (thread SAE 3000 - 3/4" UNC) Central outlet (thread G1) Centra outlet (thread 1°5/36-12 UNF) Central outiet (€rread SAE 3000 - 3/4" HA) Central outiet (thread SAE 3000 - 3/4" UNC) Lateral outlet (thread G1) Lateral outlet (thread 1°5/16-12 UNF) Front outlet side A (thread 6 1) Front outlet side A (thread 1°5/16-12 UNF) ™ Front outlet side A (thread SAE 3000 - 3/4” MA) Front outlet side A (thread SAE 3000 - 3/4” UNC) Rear outlet side B (thread G 1) Rear outlet side 8 ‘only for (thread 1°5/16-12 UNF) aa Rear outlet side 8, (thread SAE 3000 - 3/4” MA) Rear outlet side 8 (thread SAE 3000 - 3/4" UNC) SECTIONAL VALVE J D12 Outlet with two tanks classification outlet identification ym Outlet section with two return (T-HPCO) | gy Outlet section with two return (T-HPCO) left right-side init (P) side init (P) owen coe outlet combination and thread available C0 Upper out T co cena! atetT N06 Texoutetsces — Q606 ‘rrceulaese ‘erase ‘eread1) C0 Upper outeT co cena atetT reroute sues QUOB frentoulit se coy orcad 316-127) Ds only coread vie the) ‘or ‘ ‘or TM ecoUprowitT TN HcoCene owe resrouitses S03“ oe ence ek (evendSAE3060 9 HA) on my (rend SAESE00 91M) C0 Upper user co cena! ausetT soa Teouiesaes QSO4 reo cea ere Se tb NC) (owed S003) $90 Upper ut T G06 frerequerse A (ores) coupe eater R06 “een ote, wee enim 8c Upper out ress) N frereosiet sek 2s only (ora i612) ay le TN +200 pera sos reroute A oy iy (vend SAE3000 51 MA) coupe cate v0 "een ote eco Upper outer (orene 9/12 UF) so Fortec seh (ove S300 380NC) co cet auttT Pos res outet se 8 ‘Gree eco ure cuter $606 “Ter ote, co canal euterT (eres) P06: reroute ommnf nly ovead516120N0) ae TM PCO Centra cutetT PSO ane : rev ut se8 (evend S200 31M) eco Ure cute $006 Tine oe reo cena cate T (cred F562 Ue) ps0 reroute se (evexe SAE 300 4 0NC) 12 J] SECTIONAL VALVE Carry-over connection (HPCO) ‘This option, available on all D12, allows the sectional valve to feed a second valve, by extending the free flow channel. In this configuration, the valve need a separated port for connection to tank. Its possible to transform sectional valve from standard to HPCO version just by ordering the appropriate conic plug: Outlet (HPCO) Outlet (7) Conic plug’ code (HPCO Plug Identification) description aty 413010207 conic plug G 3/8 x 15 1 35 Joe SECTIONAL VALVE J D12 Drewes Description Ordercode Qty Code ote 6364 ‘Seting 100 bar Plt operated pressure rei valve (*) 2608 1 ‘Seti: 200 bar aaa Seng: 320 bar Reet valve pugped spoio7o0n Nal Actin check vee 915050701 - stra plat valve sisoso701 Soerlé dup valve (12 we) (8) 5080702 Solel dup ave (28 we) (*) 15080703 hug wth pressur-gauge connection 40107003, 21207015 woo. for proected ever ‘acakhne talinastonzeee azo701—*woo1a fer erate actuation 421207007 ‘woo2a for protected ever ' pasion double acting A and Bo tak peo! fe ¢ et ne 3 postions snge-actng on & 4712070281 WOO for protected ever 3 potions sngl-atng on 8 azi207025 woo for protected ever ‘pasos doube-acting wih foto the # ps 4720701 WOI2A for protected ever 2320207002, a anoao7oos | OOH ‘nly for WOH spot 320307001 Protected vet sofey lever Reoovec; + 10L= 102 aremaTaae Hyéracacuation wt sie ports 3205070012 (HOO D12 |] SECTIONAL VALVE Ref, Description 3 postion spring centred soot Detenin Mand eterna Detetin 8 Detentin 4 aston Prearangement dal cmmend Pneumatic ntl ON-OFF Proportional emt cota Ectrpneuratc contre ON OFF (12 de) ctropneurtic control O-OFF (24 ee) ag Etetohy rac ON-OFF (2 vee) Ectohydauic ON-OFF (28 ve) cto drauicProprtona (12 we) etry trauic Proportional (24 we) ctr frauie ON-OFF (12 we) with reducing ave ectrohydauc ON-OFF (24 wd) with reducing vale ctohydauic Proportional (12 ve) with reducing valve ecohydrauicPoprconal (26 we) wth ecuing valve ctr drauie ON-OFF (12 We) wit ecg aire Ectrohydraulc ON-OFF (24 wd) wth reducing vale etohydauic Proportional (12 ve) with reduig valve ectrohydrauic Proprconal (26 vl) wth recucing valve 5 Check valve on he wark secon Anthac vive on pre & Arlaviation vale on port A Prearangernt er aul vale on par A Antibac vive on pre Alain vale on port 8 Prewrangerent or usr vale on por 8 Pug kt (6 34) B ugk (Gs) Pug ("4/1246 UF) order code ‘320707001, ‘320807003, 320707007, 321107004 321207007, 321607001 321607002 aaiso702t 321407022 ‘322007001, 1322007002 ‘321407023, ‘321407024 322007003 1322007006 1321407031 ‘321407022 1322007005, ‘322007006 ‘320207001, 4208 2a 2048 ‘15080603, ‘0406003, 2948, ‘sos06os ‘0406001, ‘90000020 ‘30000025, ‘300007002 (*)_ = forcifferent settings please contact our Sales Dpt, (4) = electric dump valve coll can be ordered separately as spare part: (see drawing "A") Ordering code Coil 12 vd: 413171235 Ordering code Coil 24 vac: 413172432 « with special spool assembly Detent in A and B Kick-out is available only ty FOIA Fo20n=FO21A raz2A=Fo23A 0620 0630 1600 F610 2600 F610 Fisoo=F1520 F1si0=F1520 Faso0=F2520 Fasi0=F2530 F1s00=F1520 1s10=F1520 F2500=F2520 Fasi0=F2520 o1PA 02a 05 PP Note nly for WO12 spot 850 ports 25° ports 50 ports 250 ports 880 ports BSP ports Une ports Ue ports Une ports Une ports only for RP and RT secon etn: 100 bar seeing: 200 bar setting: 300 bar seting: 100 bar setting: 200 bar seting: 300 bar a7 Joe SECTIONAL VALVE J D12 eae ‘Outlet and work section Rit. Order code Description Qty 1 423401016 Ring 3 2 423401015, Ring 2 3 412020601 OLR, 90SH 28,25 x 2,62 (2-122) 3 4 412020602 OLR, 90SH 32,99 x 2,62 (2-125) 1 Complete Gasket kit: order code - 350907001 12 J} SECTIONAL VALVE cS Ch Guidelines = Mount the control valve securely to a flat surface (recommended 3 point fixing); at the time do not use a hammer to positioning by hitting. = When handling the control vaive, be careful not hold the pilot cover or return spring cap of the spool or accessory valves such as main relief valves and anti-shock relief valves. = Clean piping materials sufficiently before use. = Make sure to prevent the port openings from being entered with dust or foreign matters. = Tighten the port connectors surely with the recommended fastening torques. = Do not direct the jet of a pressure washing unit directly to the valve Fittings tightening torque (Nm) thread type port P Port A= 8 PortT BSP (150 - 228) 63/4 63/4 G3/4 with rubber sealing (DIN 3869) 120 120 120 with copper or steel and rubber washer 120 120 120 BSP (150 - 228) e1 et e1 with rubber sealing (DIN 3869) 150 150 150 With copper or steel and rubber washer 150 150 150 UN-UNF (180 - 725) 71/1612 UNF 11/1612 UNF 11/16 12 UNF with OR. 120 120 120 General clamping torque ‘The following table provides the main tightening torques of the distributor D12: eaten P38 se Tnaeaerars-arne {SD Ps 30 Nm | oe Plug - 30 Nm > lantishock Valve - 80 Nm [Screw = Hex6 Py SECTIONAL VALVE J D12 ensions - Thread codes The connection ports size is indicated by an ordering code common for all Hydrocontro! products. Following table shows all available connections. [ncn keceoe) Type MIOKS MIS METZ Code Mot Moz Mo3. Eoin tee) Type aya 3/8" yar 3a" © ya yz 2 Code Go2 G03 Goa Gos Gos G07 Gos Goo CAT) 9/16" 8 UNF 4" LGUNF 7/8" 14UNF | JTY/612UNF YS/A6I2 UNF 1°5/8 12 UNF SAES SAES —SAEIO. «SAEZ. —«SAEIG.——SAE20, Code voz v03 04 vos wos u07 Type Dimensions - SAE Flange codes Bees) wana arate ats a2 a2 ka (ma) (UNC) (A) (UNC) (MA) (UNC) (MA) (UNC) (MA) (UNC) (MA) (UNC) Code S03 S04 S05 S06 S07 SOB SOD S10 Si1 Si2 SI5 S16 9 1 2 2% 32 3 3 3 St St 7% 76 478 476 524 52,4 58,7 58,7 69,9 69,9 78 7,8 10641064 22,3 223° 26,2 26,2 30,2 30,2 35,7 35,7 42,9 42,9 6191, M10 3/816 MIO 3/8-16 MIO 716-14 M12 1/213 M12 1/243 M16 5/811 Type coe> Sees) ya" aah a ar atiya aaa a2 A4/2. (MA) (UNC) (A) (UNC) (MA) (UNC) (MA) (UNC) Code S33 S34 S35 S36 S37 S38 S39 S40 i 19S BB 508 50,8 57.2 57,2 66,6 66,6 73,3 79,3 238 238 278 278 38 3148 355 36,5 Mio 3/816 M12 7bl4 M14 «1/213 MIS 5/811 Type ooa> sow If 40 www.hydroma.cz www.hydroma.eu www.hidromasistems. pl

You might also like