EN EN
02. PACKAGE 03. OPERATOR
INSIDE PACKAGE FUNCTIONALITY
In the package you will find the following components: The operator LINCE, is a product developed exclusively for the automatic opening of
swing gates.
01• 02 Swing operators LINCE
02• 01 Control Board Besides being pratical, safe and powerful, this product has a new function incorporated
03• 02 transmitters so that you can transform a motor to apply on right leaves to left leaves.
04• 02 Front supports This allows greater flexibility in the use of each operator.
05• 02 Rear supports
06• 02 Capacitors 8μF
07• 01 Photocells
08• 01 User’s manual
09• 02 Release keys
03• 07•
02• 02
210mm
05 06
280mm 810mm
03 01 • Loosen the screws that secure the 02 • Remove Lower Part
Lower Part to Middle Part
EN EN
03. OPERATOR 03. OPERATOR
FUNCTIONALITY UNLOCK OPERATOR
07 08 12 13
03 • Loosen the screws of the Middle Part 04 • Remove Middle Part 01 • Remove the plastic cap from the rear Information engraved on the unlock shaft
end D=Unlock || B=Lock
09 10 14 15
05 • Rotate Upper Part 180° 06 • Assemble operator by tightening all 02 • Insert Release key on the unlock shaft. 03 • Rotate key 180 ° in the direction indi-
components with the screws cated in the figure to unlock
04 • Operator unlocked.
EN EN
03. OPERATOR 04. INSTALLATION
TECHNICAL SPECIFICATIONS VERTICAL INSTALLATION DIMENSIONS
LINCE specifications are as follow: The operator LINCE must be installed with a small inclination , to prevent water
infiltration through the extension arm.
For this, the front support must be fixed to the gate with a height lower than the height
LINCE300 LINCE400 LINCE600
of the rear support. See example below:
• Power Supply AC 230V 50/60Hz AC 230V 50/60Hz AC 230V 50/60Hz
• Power 180W 180W 180W
• Current 1,3A 1,3A 1,3A
• RPM 1400 RPM 1400 RPM 1400 RPM
• Noise level <50dB <50dB <50dB
A
• Force 2300N 2300N 2300N
• Operating temperatures -25°C to 75°C -25°C to 75°C -25°C to 75°C
• Thermal protection 120°C 120°C 120°C
• Protection class IP54 IP54 IP54
• Working frequence 25% 25% 25%
• Course 300mm 400mm 600mm
B
• Max leaf lenght 2500mm 3000mm 4000mm A B
• Capacitor 8µF 8µF 8µF
18
LINCE 300 || 400 || 600 dimensions are the following:
Dimension A • Vertical distance from the floor to the top of the rear support .
Dimension B • Vertical distance from the floor to the top of the front support.
962mm || 1162mm || 1562mm A ? mm • Set dimension A (this can be any size of your choice).
B A-10mm • After you set dimension A, subtract 10mm to find dimensionB.
175mm
Example:
• If the height of the rear bracket (dimension A)is set at 600 mm, then the height of the
159mm front bracket (dimension B) will be 590 mm (600mm-10mm).
It is very important that these dimensions are respected! Only this way can be as-
sured the correct functioning and durability of the operators!
647mm || 747mm || 947mm 104mm 17 It is also very important to have a levelled ground/terrain!
EN EN
04. INSTALLATION 04. INSTALLATION
VERTICAL INSTALLATION DIMENSIONS HORIZONTAL INSTALLATION DIMENSIONS
On the Illustrated diagrams below and on the next page, are the horizontal dimensions
for the installation of the automated system.
(EXTERIOR)
Y
W Axis of rotation of the gate
(center of the door hinge)
Distance between the
centers of the holes on the
X supports from operator
Axis of rotation of the Y
motor, on the rear support Closing mechanical
Opening
W stopper
direction
(INTERIOR) Axis of rotation of the motor,
X
(INTERIOR) on the front support
Opening mechanical stopper Axis of rotation of the Distance between the centers of the
19 motor, on the rear support holes on the supports from operator 20
Opening angle
X Y W Opening angle
X Y W
• LINCE300 95º 120 a 180 120 a 180 895 a 900
• LINCE300 95º 120 a 180 120 a 180 595 a 600
95º 120 a 180 120 a 180 1095 a 1100 • LINCE400 95º 160 a 200 120 a 180 695 a 700
• LINCE400
120º 160 a 180 120 a 140 1095 a 1100 • LINCE600 95º 160 a 300 120 a 280 900 a 905
95º 120 a 350 120 a 200 1495 a 1500
• LINCE600
120º 200 a 280 120 a 200 1495 a 1500
Legend:
Dimension X - Horizontal distance between hinge axis of the door and the rear axle of the motor.
Dimension Y - Vertical distance between hinge axis of the door and the rear axle of the motor.
It is very important that these dimensions are respected! Only this way can be assured
the correct functioning and durability of the operators! Dimension W - Distance between axis of the motor brackets.
EN EN
04. INSTALLATION 04. INSTALLATION
INSTALLATION STEPS INSTALLATION STEPS
EN EN
04. INSTALLATION
INSTALLATION MAP
• JUNCTION
BOX
LEGEND:
• Connection cables
27
It is important to use mechanical stoppers in the opening and closing position of the It is important to use junction boxes for connections between motors, components
gate.If not respected, components of the automation may suffer efforts for which they and control unit. All cables must enter and exit on the bottom of the junction and
were not prepared, and as a result will be damaged. control board box.
EN
05. TROUBLESHOOTING
FINAL CONSUMERS INSTRUCTIONS INSTRUCTIONS FOR SPECIALIZED INSTALLERS
• Motor •Make sure you • Still not working • Consult a qualified 1 • Open control box and check if 3 • Disconnect motors from 4 • If the motors work, the 5 • If the motors doesn’t work,
doesn't work have 230V power MOTORLINE technician. it has 230V power supply; control board and test them by problem is on the control board. remove them from installation
at all supply connected to 2 • Check input fuses; connecting directly to power Pull it out and send it to our site and send to our MOTORLINE
operator and if it is supply in order to find out if they MOTORLINE technical services technical services for diagnosis.
working properly. have problems (see page 09A). for diagnosis;
• Motor • Unlock motor and • Encountered • Consult an experienced 1 • Check all motion axis and associated motion systems related with gate and operators (pins, hinges, etc.) to find out what is the problem.
doesn’t move move gate by hand to problems? gate expert
but makes check for mechanical
noise problems on the gate. •Gate moves easily? • Consult a qualified
1 • Check capacitors, testing 2 • If capacitors are not the 3 • If the motors work, the 4 • If the motors doesn’t work,
MOTORLINE technician. operator with new capacitors; problem, disconnect motors problem is from control board. remove them from installation
from control board and test them Pull it out and send it to our site and send to our MOTORLINE
by connecting directly to power MOTORLINE technical services technical services for diagnosis.
supply in order to find out if they for diagnosis;
have problems (see page 09A).
• Motor opens • Unlock motor and • Gate opened but 1 • Check if there is any All MOTORLINE control boards have LEDs that A) SECURITY SYSTEMS: B) START SYSTEMS:
but doesn’t move gate by hand to didn’t close again. obstacle in front of the easily allow to conclude which devices are
close closed position. photocells; with anomalies. 1 • Close with a shunt all safety systems 1 • Disconnect all wires from START terminal
Lock motor(s) again 2 • Check if any of the control All safety devices LEDs (DS) in normal on the control board (check manual of the input.
and turn off power devices (key selector, push situations remain On. control board in question). 2 • If the LED turned Off, try reconnecting one
supply for 5 seconds. button, video intercom, etc.) All "START" circuits LEDs in normal situations If the automated system starts working device at a time until you find the defective
Reconnect it and send of the gate are jammed and remain Off. normally check for the problematic device. device.
order to open sending permanent signal to 2 • Remove one shunt at a time until you find
gate using control unit; If LEDs devices are not all On, there is some the malfunction device .
transmitter. 3 • Consult a qualified security systems malfunction (photocells, 3 • Replace it for a functional device and NOTE:
MOTORLINE technician. safety edges), etc. check if the operator works correctly with n case procedures described in sections A)
If "START" circuits LEDs are turn On, there is all the other devices. If you find another one and B) don’t result, remove control board and
a control device sending permanent signal. defective, follow the same steps until you find send to our technical services for diagnosis.
all the problems.
• Motor • Unlock motor and • Encountered • Consult an experienced 1 • Check all motion axis and associated motion systems related with gate and operators (pins, hinges, etc.) to find out what is the problem.
doesn’t make move gate by hand to problems? gate expert
complete check for mechanical
route problems on the gate. • Gate moves easily? • Consult a qualified 1 • Check capacitors, testing 4 • If motors work well and move 5 • If this doesn’t work, remove NOTE: Setting force of the
MOTORLINE technician. with new capacitors; gate at full force during the control unit and send it to controller should be sufficient to
2 • If capacitors are not the entire course, the problem is MOTORLINE technical services make the gate open and close
problem, disconnect motors from controller. Set force using services. without stopping, but should
from control board and test them trimmer on the board. Make a stop with a little effort from a
by connecting directly to power new working time programming , person.
supply in order to find out if they giving suffient time for opening In case of safety systems failure,
are faulty; and closing with appropriate the gate shall never cause
3 • If the motors doesn’t work, force (see manual of the physical damaged to obstacles
remove them from installation controller in question). (vehicles, people, etc.).
site and send to our MOTORLINE
technical services for diagnosis.
EN
06. COMPONENTS TEST 07. MAINTENANCE
CAPACITORS CONNECTION SCHEME MAINTENANCE
To detect which components have problems on an automated system, sometimes it is • Clean stainless steel arm
necessary to conduct tests using a direct connection to a 230V AC power supply. For
this it is necessary to merge a 8μF capacitor to make the operator to work. • With a cloth soaked in lubricant spray,
In the diagram below is shown how this link should be made and how to merge the wipe any residue that accumulates on
different wires of the components. the operator’s stainless steel arm.
• Apply a small amount of spray lubricant
NOTES: on the arm and using a dry cloth remove
• To perform these tests you don’t need to remove operator from where it is installed, the excess, leaving a homogeneous
because this way you can know if connected directly to power supply it will work layer of lubricant over the arm.
correctly.
• The order of wiring capacitor to motor wires is not important, as long you connect one 29
wire to Brown wire of motor and the other one to Black wire of motor;
• Common wire should always be connected to power supply.
• To reverse motor direction, just replace Black wire with Brown wire of the operator on • Lubricate pins
the power supply. • Remove front and rear caps
• Place a small amount of lubricant on
the holes that contains support pins.
• Install caps on the respective holders.
230V
Common (Blue) POWER SUPPLY
30
CAPACITOR
Earth wire
8µF
28 31
All tests must be performed by qualified personnel due to serious danger associated
These maintenance measures must be applied every year in order to insure proper
with the misuse of electrical systems!
functioning of the automated system.
EN EN
T.RIT.ANT
T. PAUSA
T.MOT.PED
T.MOTOR
INB.CMD.AP
CODE PED
CODE
AUT/P-P
CONNECTIONS SCHEME
FUSE 5X20
- Force +
08. CONTROL BOARD MC2
1 2 3 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 11 12
PL L N
Lock
Blue
Blue
Black
Black
Brown
Brown
Earth wire
Earth wire
Light Bulb
Antenna
8
µ
8
µ
Complete Pedestrian
Opening Opening
(2 leaves) (1 leaf)
Interior Photocells