Professional Documents
Culture Documents
Modular Type
parallel operation
• Modular design decreases MTTR
• High scalability
• Built-in maintenance bypass switch for easy
maintenance without interruptible
• High efficiency double conversion online UPS
• Flexible battery configuration and adjustable
charging current
A+ 42U-300 (PM-50)/A+ 42U-350 (PM-50)/ • High overload capability
A+ 42U-400 (PM-50)/A+ 42U-500 (PM-50) A+ 42U-300(PM-50) S
• Power walk-in function
Product Outlook
10" touch LCD screen
• Dynamic power flow in color screen
• Operation status for each power module 1+1 Cabinet Parallel Operation 1+1 Cabinet Parallel Operation
• Adjustable charging current via LCD panel
Switch Unit
Switch Unit
Multiple
Communication
Multiple
Communication
Security Lock
Power Module
• 50KW single power
module in 3U
• 6 power modules for
300KW output power
42U Cabinet front 42U Cabinet with depth of 1065mm 42U Cabinet with depth of 850mm
O n l i n e U P S
Modular Type
DPA-45 14.8KW 2
DPA-80H 22KW 4
U P S
DPC-110V 44KW 2
DPA-110V 44KW 1
DPA-160V 60KW 1
O N L I N E
Stamping
Machine
DPC-200V 74KW 2 UPS normal operation with
102% industrial load
CTP-45 7.5HP(5.6KW) 2
CT2-110 15HP(11.2KW) 1
CTP-160 20HP(15KW) 2
APlus 300kw
CT2-200 25HP(18.6KW) 3
Digital stamping
HPE-3048 50KVA 9
machine
D130 25KW 1
EM260 43.3KW 1
D350 62KW 1
D400 69KW 7
MPS-XIIC 18KVA 1
UPS normal operation with
Laser cutter
119% industrial load
HLE-1530 40KW 4
U P S
BATTERY TYPE External Battery
ONE POWER MODULE CAPACITY 50KVA/50KW
MAX. POWER MODULE NO. 6 6 7 8 10
INPUT
O N L I N E
Nominal Voltage 3 x 380/400/415 VAC (3Ph+N)
Voltage Range -20% ~ +15%
Nominal Frequency 50/60Hz (Auto Sensing)
Frequency Range 40Hz ~70Hz
Power Factor > 0.99 @ 100% Load , >0.98 @ 50% Load
Harmonic Distortion (THDi) < 4% @ 100% load
OUTPUT
Nominal Voltage 3 x 380/400/415 VAC (3Ph+N)
Voltage Regulation(Steady state) ≦ ± 1% Typical (balanced load) ; ≦ ± 2% Typical (unbalanced load)
Nominal Frequency 50/60Hz
Frequency Range(Synchronized) 46Hz ~ 54Hz or 56Hz ~ 64Hz
Overload Capability 1 hour for ≦ 110%, 10 mins for 111% ~ 125%, 1 min for 126%~150% and 200ms for >150%
Harmonic Distortion ≦ 2% THD (Linear Load) ; ≦ 4% THD (Non-linear Load)
Efficiency 95.5%
BATTERY / CHARGER
Nominal Voltage +/- 192V ~ +/- 240V (Selectable)
Maximum Voltage +/- 240V (12V x 40 Pcs)
Minimum Voltage +/- 192V (12V x 32 Pcs)
Floating Charge Voltage 2.28V / Cell (2.25 ~2.33 Selectable)
Boost Charging Voltage 2.35V/Cell
Temperature Compensation Yes
Maximum Charging Current
12A (Adjustable)
(Per Power Module)
PHYSICAL
Cabinet Dimension (D x W x H) mm 850 x 600 x 2000 1065 x 600 x 2000 1065 x 600 x 2000 1065 x 1000 x 2000 1065 x 1000 x 2000
Net Weight (Kg) 490 545 654 932 1020
ENVIRONMENT
Operating Temperature 0 ~ 40°C
Relative Humidity 0 ~ 95% non-condensing
Altitude* <1000m for Nominal power
IP Protection IP 20
MANAGEMENT
Smart RS-232 / USB Supports Windows® Family, Linux and MAC
Optional SNMP Power management from SNMP manager and web browser
STANDARDS
Safety IEC/EN 62040-1
EMC IEC/EN 62040-2 Category C3
***If the UPS is installed or used in a placewhere the altitude is above than 1000m, the output power must be derated one percent per 100m.
Product specifications are subject to change without further notice.
guarantee
• Supports horizontal expansion by 1+1 cabinet
parallel operation.
• Hot-swappable modular design decreases MTTR
O N L I N E
• High scalability
• Built-in maintenance bypass switch for easy
maintenance without interruptible
• High efficiency double conversion online UPS
• Flexible battery configuration and adjustable
charging current
• High overload capability
480K 8 modules
300K 5 modules • Power walk-in function
600K 10 modules 120K 2 modules
420K 7 modules 180K 3 modules • Built-in dynamic password protection
• Built-in ultra communication slot
Product Outlook
Switch
Unit
Multiple
Communication
Security Lock
Power Module
• Expand capacity by
adding power
modules
• N + 1 parallel
redundancy for power
guarantee
• Vertical expansion up
to 10 modules
(600KW)
U P S
BATTERY TYPE External Battery
ONE POWER MODULE CAPACITY 60KVA / 60KW
MAX. POWER MODULE NO. 2 3 5 7 8 10
INPUT
O N L I N E
Nominal Voltage 3 x 380/400/415 VAC (3Ph+N)
Voltage Range -30% ~ +20%
Nominal Frequency 50/60Hz (Auto Sensing)
Frequency Range 40Hz ~70Hz
Power Factor > 0.99 @ 100% Load , >0.98 @ 50% Load
Harmonic Distortion (THDi) < 3% @ 100% load
OUTPUT
Nominal Voltage 3 x 380/400/415 VAC (3Ph+N)
Voltage Regulation(Steady state) ≦± 1% Typical (balanced load) ; ≦± 2% Typical (unbalanced load)
Nominal Frequency 50/60Hz
Frequency Range(Synchronized) 46Hz ~ 54Hz or 56Hz ~ 64Hz
Overload Capability 1 hour for ≦ 110%, 10 mins for 111% ~ 125%, 1 min for 126%~150% and 200ms for >150%
Harmonic Distortion ≦2% THD (Linear Load) ; ≦4% THD (Non-linear Load)
Efficiency 96%
BATTERY / CHARGER
Nominal Voltage +/- 192V ~ +/- 240V (Selectable)
Maximum Voltage +/- 240V (12V x 40 Pcs)
Minimum Voltage +/- 192V (12V x 32 Pcs)
Floating Charge Voltage 2.28V / Cell (2.25 ~2.33 Selectable)
Boost Charging Voltage 2.35V/Cell
Temperature Compensation Yes
Maximum Charging Current
18A (Adjustable)
(Per Power Module)
PHYSICAL
Cabinet Dimension (D x W x H) mm 1100x600x1475 1100x600x1475 1100x600x2010 1100x600x2010 1065x1000x2000 1065x1000x2000
Net Weight (Kg) 308 352 516 654 932 1020
ENVIRONMENT
Operating Temperature 0 ~ 40°C
Relative Humidity 0 ~ 95% non-condensing
Altitude* <1000m for Nominal power
IP Protection IP 20
MANAGEMENT
Smart RS-232 / USB Supports Windows® Family, Linux and MAC
Optional SNMP Power management from SNMP manager and web browser
STANDARDS
Safety IEC/EN 62040-1
EMC IEC/EN 62040-2 Category C3
***If the UPS is installed or used in a placewhere the altitude is above than 1000m, the output power must be derated one percent per 100m.
Product specifications are subject to change without further notice.