You are on page 1of 5

Onl ine UPS

Modular Type

APlus Modular UPS (50kW Power Module)


• 50KW for single power module in 3U
• Single 42U cabinet up to 500KW
U P S

• Two cabinet size for 300KW: 1065mm and 850mm


• N+1 or N+X parallel redundancy for power
guarantee
• Supports horizontal expansion by 1+1 cabinet
O N L I N E

parallel operation
• Modular design decreases MTTR
• High scalability
• Built-in maintenance bypass switch for easy
maintenance without interruptible
• High efficiency double conversion online UPS
• Flexible battery configuration and adjustable
charging current
A+ 42U-300 (PM-50)/A+ 42U-350 (PM-50)/ • High overload capability
A+ 42U-400 (PM-50)/A+ 42U-500 (PM-50) A+ 42U-300(PM-50) S
• Power walk-in function

Product Outlook
10" touch LCD screen
• Dynamic power flow in color screen
• Operation status for each power module 1+1 Cabinet Parallel Operation 1+1 Cabinet Parallel Operation
• Adjustable charging current via LCD panel

Switch Unit

Switch Unit

Multiple
Communication

Multiple
Communication

Security Lock

Power Module
• 50KW single power
module in 3U
• 6 power modules for
300KW output power

42U Cabinet front 42U Cabinet with depth of 1065mm 42U Cabinet with depth of 850mm
O n l i n e U P S
Modular Type

Industrial load testing


UPS Industrial Load Model Nominal power /per unit Quantity Result

DPA-45 14.8KW 2

DPA-80H 22KW 4

U P S
DPC-110V 44KW 2

DPA-110V 44KW 1

DPA-160V 60KW 1

O N L I N E
Stamping
Machine
DPC-200V 74KW 2 UPS normal operation with
102% industrial load
CTP-45 7.5HP(5.6KW) 2

CT2-110 15HP(11.2KW) 1

CTP-160 20HP(15KW) 2
APlus 300kw
CT2-200 25HP(18.6KW) 3

Digital stamping
HPE-3048 50KVA 9
machine

D130 25KW 1

EM260 43.3KW 1

UPS normal operation with


Injection machine EM400 56.6KW 1
102% industrial load

D350 62KW 1

D400 69KW 7

MPS-XIIC 18KVA 1
UPS normal operation with
Laser cutter
119% industrial load
HLE-1530 40KW 4

Industrial load testing


Stamping machine
with APlus UPS
DPC-110V DPC-200V CT2-110

Digital stamping machine Injection machine Laser cutter


HPE-3048 EM260 D350 MPS-XIIC
O n l i n e UP S
Modular Type

APlus Modular UPS Selection Guide


A+ 42U-300 A+ 42U-300 A+ 42U-350 A+ 42U-400 A+ 42U-500
MODEL
(PM-50) S (PM-50) (PM-50) (PM-50) (PM-50)
PHASE 3-phase in / 3-phase out
CABINET CAPACITY* 300KW 300KW 350KW 400KW 500KW

U P S
BATTERY TYPE External Battery
ONE POWER MODULE CAPACITY 50KVA/50KW
MAX. POWER MODULE NO. 6 6 7 8 10
INPUT

O N L I N E
Nominal Voltage 3 x 380/400/415 VAC (3Ph+N)
Voltage Range -20% ~ +15%
Nominal Frequency 50/60Hz (Auto Sensing)
Frequency Range 40Hz ~70Hz
Power Factor > 0.99 @ 100% Load , >0.98 @ 50% Load
Harmonic Distortion (THDi) < 4% @ 100% load
OUTPUT
Nominal Voltage 3 x 380/400/415 VAC (3Ph+N)
Voltage Regulation(Steady state) ≦ ± 1% Typical (balanced load) ; ≦ ± 2% Typical (unbalanced load)
Nominal Frequency 50/60Hz
Frequency Range(Synchronized) 46Hz ~ 54Hz or 56Hz ~ 64Hz
Overload Capability 1 hour for ≦ 110%, 10 mins for 111% ~ 125%, 1 min for 126%~150% and 200ms for >150%
Harmonic Distortion ≦ 2% THD (Linear Load) ; ≦ 4% THD (Non-linear Load)
Efficiency 95.5%
BATTERY / CHARGER
Nominal Voltage +/- 192V ~ +/- 240V (Selectable)
Maximum Voltage +/- 240V (12V x 40 Pcs)
Minimum Voltage +/- 192V (12V x 32 Pcs)
Floating Charge Voltage 2.28V / Cell (2.25 ~2.33 Selectable)
Boost Charging Voltage 2.35V/Cell
Temperature Compensation Yes
Maximum Charging Current
12A (Adjustable)
(Per Power Module)
PHYSICAL
Cabinet Dimension (D x W x H) mm 850 x 600 x 2000 1065 x 600 x 2000 1065 x 600 x 2000 1065 x 1000 x 2000 1065 x 1000 x 2000
Net Weight (Kg) 490 545 654 932 1020
ENVIRONMENT
Operating Temperature 0 ~ 40°C
Relative Humidity 0 ~ 95% non-condensing
Altitude* <1000m for Nominal power
IP Protection IP 20
MANAGEMENT
Smart RS-232 / USB Supports Windows® Family, Linux and MAC
Optional SNMP Power management from SNMP manager and web browser
STANDARDS
Safety IEC/EN 62040-1
EMC IEC/EN 62040-2 Category C3
***If the UPS is installed or used in a placewhere the altitude is above than 1000m, the output power must be derated one percent per 100m.
Product specifications are subject to change without further notice.

Model Description Weight (kg)

PM-50 3P/3P 50KVA/50KW power module 44

PM-50 (S) 3P/3P 50KVA/50KW power module in depth of 650 mm 36


On l i ne U P S
Modular Type

APlus Modular UPS (60kw Power Module)


• 60KW single power module in 3U
• N+1 or N+X parallel redundancy for power
U P S

guarantee
• Supports horizontal expansion by 1+1 cabinet
parallel operation.
• Hot-swappable modular design decreases MTTR
O N L I N E

• High scalability
• Built-in maintenance bypass switch for easy
maintenance without interruptible
• High efficiency double conversion online UPS
• Flexible battery configuration and adjustable
charging current
• High overload capability
480K 8 modules
300K 5 modules • Power walk-in function
600K 10 modules 120K 2 modules
420K 7 modules 180K 3 modules • Built-in dynamic password protection
• Built-in ultra communication slot

Product Outlook

10" touch LCD screen


• Dynamic power flow in color screen
• Operation status for each power module
• Adjustable charging current via LCD panel
1+1 Cabinet Parallel Operation

Switch
Unit

Multiple
Communication

Security Lock
Power Module
• Expand capacity by
adding power
modules
• N + 1 parallel
redundancy for power
guarantee
• Vertical expansion up
to 10 modules
(600KW)

42U Cabinet 42U 600KW Cabinet


O n l i n e UP S
Modular Type

APlus Modular UPS Selection Guide


MODEL A+ 30U-120 A+ 30U-180 A+ 42U-300 A+ 42U-420 A+ 42U-480 A+ 42U-600
PHASE 3-phase in / 3-phase out
CABINET CAPACITY* 120 KW 180 KW 300 KW 420KW 480KW 600KW

U P S
BATTERY TYPE External Battery
ONE POWER MODULE CAPACITY 60KVA / 60KW
MAX. POWER MODULE NO. 2 3 5 7 8 10
INPUT

O N L I N E
Nominal Voltage 3 x 380/400/415 VAC (3Ph+N)
Voltage Range -30% ~ +20%
Nominal Frequency 50/60Hz (Auto Sensing)
Frequency Range 40Hz ~70Hz
Power Factor > 0.99 @ 100% Load , >0.98 @ 50% Load
Harmonic Distortion (THDi) < 3% @ 100% load
OUTPUT
Nominal Voltage 3 x 380/400/415 VAC (3Ph+N)
Voltage Regulation(Steady state) ≦± 1% Typical (balanced load) ; ≦± 2% Typical (unbalanced load)
Nominal Frequency 50/60Hz
Frequency Range(Synchronized) 46Hz ~ 54Hz or 56Hz ~ 64Hz
Overload Capability 1 hour for ≦ 110%, 10 mins for 111% ~ 125%, 1 min for 126%~150% and 200ms for >150%
Harmonic Distortion ≦2% THD (Linear Load) ; ≦4% THD (Non-linear Load)
Efficiency 96%
BATTERY / CHARGER
Nominal Voltage +/- 192V ~ +/- 240V (Selectable)
Maximum Voltage +/- 240V (12V x 40 Pcs)
Minimum Voltage +/- 192V (12V x 32 Pcs)
Floating Charge Voltage 2.28V / Cell (2.25 ~2.33 Selectable)
Boost Charging Voltage 2.35V/Cell
Temperature Compensation Yes
Maximum Charging Current
18A (Adjustable)
(Per Power Module)
PHYSICAL
Cabinet Dimension (D x W x H) mm 1100x600x1475 1100x600x1475 1100x600x2010 1100x600x2010 1065x1000x2000 1065x1000x2000
Net Weight (Kg) 308 352 516 654 932 1020
ENVIRONMENT
Operating Temperature 0 ~ 40°C
Relative Humidity 0 ~ 95% non-condensing
Altitude* <1000m for Nominal power
IP Protection IP 20
MANAGEMENT
Smart RS-232 / USB Supports Windows® Family, Linux and MAC
Optional SNMP Power management from SNMP manager and web browser
STANDARDS
Safety IEC/EN 62040-1
EMC IEC/EN 62040-2 Category C3
***If the UPS is installed or used in a placewhere the altitude is above than 1000m, the output power must be derated one percent per 100m.
Product specifications are subject to change without further notice.

Model Description Dimension DxWxH(mm) Weight (kg)

PM-60 3P/3P 60KVA/60KW power module 750 x 438 x 130 (3U) 44

You might also like