DIGITAL MULTIMETER
• 750V AC
B-535 • AUTO-RANGE
•
•
Display Mode: LCD
Display Counts: 6000
• TRUE-RMS • Digits : 3 5/6
• Auto Ranging .
• Sampling rate: 3 Times
per second
ACV & • Max / Min record
ACCURATE
DCV function
• True RMS
• AC/DC Voltage
HIGH QUALITY ACA &
• AC/DC Current
DCA
• A / D Conversion
RELIABLE measurement
T-RMS • Resistance
• Capacitance
DURABLE • Frequency
• Diode Test
3 5/6
DIGITS • Continuity Test
EASY TO READ • NCV
• Data Hold
6000 • Auto Power Off
COUNTS
STURDY • Low Voltage Indication
• Relative measurement
• Overload protection
SAFETY NCV
ACCESSORIES
CE COMPLIANT AUTO (Included)
RANGE • Instruction Manual
• Pair of Test Leads
• AAA 1.5 VOLT Battery
DC VOLTAGE CAPACITANCE
Range Accuracy Resolution
Range Accuracy Resolution
60 nF 10 pF
6V 0.001 V
600 nF 100 pF
± (0.5% + 3)
60 V 0.01 V 6 uF 1 nF
± (3.5%+20)
600 V 0.1 V 60 uF 10 nF
600 uF 100 nF
1000 V ± (0.8% + 10) 1V 6 mF 11 uF
30 mF ± (5% + 3) 10 uF
DC CURRENT
RESISTANCE
Range Accuracy Resolution Range Accuracy Resolution
600 µA 0.1uA 600 Ω ± (0.8%+5) 0.1 Ω
6 KΩ 1Ω
6000 µA 1 uA
± (1.2%+10) 60 kΩ 10 Ω
60 mA 10 µA ± (0.8%+3)
600 kΩ 100 Ω
600 mA 100 µA 6 MΩ 1 kΩ
40 M Ω ± (2.5% + 3) 10 kΩ
6A 0.001 A
± (2.0%+30)
10 A 0.01 A DIODE ON AND OFF TEST
Range Display Value Test Conditions
Positive DC current of
AC CURRENT (T-RMS) Diode forward voltage about 1mA, open
drop circuit voltage of about
Range Accuracy Resolution 3V,
→|−0))) The buzzer buzzes for
Open circuit voltage is
600 µA 0.1uA a long time, and the
about 3V Press
“SELECT” to switch
test resistance is less
6000 µA 1 uA than (50±20) Ω
between two
functions
± (1.2%+10)
60 mA 10 µA
600 mA 100 µA ENVIRONMENTAL SPECIFICATION