Professional Documents
Culture Documents
Clinical Relevance
Lithium disilicate computer-aided design/computer-aided manufacturing (CAD/CAM)
crowns with or without composite resin buildup exceeded expectations in restoring
endodontically treated molars. The 2-mm buildup provided the highest load to failure and
good fatigue resistance, so it can be indicated in cases of high occlusal loading.
2-mm buildup; and no buildup endocrown associated with higher loads to failure than
preparation) and were restored with Cerec 3 the endocrown and the 4-mm buildup, but all
CAD/CAM lithium disilicate crowns (IPS restoration designs survived far beyond the
e.max CAD). The intaglio surfaces of restora- normal range of masticatory forces.
tions (n=15) were conditioned by hydrofluoric
acid etching and silane, and prepared teeth INTRODUCTION
were treated with airborne-particle abrasion,
Long-term success of endodontic treatment is highly
followed by cementation with RelyX Unicem 2
dependent on the restorative treatment that fol-
Automix. Specimens were then subjected to
lows.1 There is wide general agreement that the
cyclic isometric loading at 10 Hz, beginning
ferrule effect is a critical element in the performance
with a load of 200 N (35000 cycles), followed by
of crowned endodontically treated molars (ETMs).2,3
stages of 400, 600, 800, 1000, 1200, and 1400 N at
In dentistry, the ferrule refers to the cervical tooth
a maximum of 30,000 cycles each. Specimens
structure that provides retention and resistance
were loaded until failure or to a maximum of
form to the restoration and protects it against
185,000 cycles. The chewing cycle was simu-
fracture. However, in cases when the ferrule is
lated by an isometric contraction (load con-
absent, there is no consensus about the optimal
trol) applied through a 10-mm in diameter
composite resin sphere (Filtek Z100). Surviv- buildup design required to rehabilitate these ETMs
ing specimens were axially loaded until fail- with extensive loss of coronal structure. Although
ure or to a maximum load of 4500 N (crosshead insertion of a post does not strengthen or reinforce
speed 0.5 mm/min). The failure mode was an ETM, posts are frequently used to retain coronal
assessed, and fractures were designated as buildup materials, which in turn are used to retain a
catastrophic (tooth/root fracture that would restoration.
require tooth extraction) or reparable (cohe- With advances in the mechanical properties of
sive or cohesive/adhesive fracture of restora- composite resins and bond strength of dentin
tion only). Groups were compared using the adhesive resins, it is logical to question whether
life table survival analysis (log-rank test at these materials can be used to develop an internal
p=0.05). Surviving specimens were loaded to adhesive ferrule effect without a post. Molars
failure and compared with one-way analysis usually have a substantial amount of dentin (includ-
of variance. ing the pulp chamber) available for bonding. In
Results: The survival rates after the fatigue addition to substituting the pulp ceiling, the com-
test were 100%, 93%, and 100% for 4-mm, 2-mm, posite resin core buildup allows clinicians to remove
and no buildup (endocrown), respectively and retention from the endodontic preparation and
were not statistically different (only one spec- control the restoration thickness. A different strat-
imen failed with a 2-mm buildup under a egy to restore ETMs is an endocrown restoration.4,5
crown that cohesively fractured at 1,400 N). This alternative approach utilizes the surface avail-
Postfatigue load to failure averaged 3181 N for able inside the pulp chamber and restores both the
4-mm buildups (15 specimens), 3759 N for 2-mm core and the crown as one component. There is little
buildups (12 specimens), and 3265 N for endo- information about the clinical quality of endocrowns
crowns (14 specimens). The 2-mm buildups generated with the CEREC (ceramic reconstruction)
were associated with higher loads to failure system; however, it appears to be feasible and at an
than endocrowns and 4-mm buildups, but no acceptable level.6,7
differences were found between 4-mm build- The aim of this study was to evaluate the influence
ups and endocrowns (p,0.05.) One endocrown of a 4-mm buildup, a 2-mm buildup or no buildup
and 2 restorations with a 2-mm buildup sur- (endocrown) on the mechanical performance and
vived the load-to-failure test (at 4500 N). Only failure mode of ETMs restored with lithium dis-
catastrophic fractures occurred after the load- ilicate computer-aided design/computer-aided man-
to-failure test. ufacturing (CAD/CAM) complete crowns placed with
Conclusions: The buildup design influenced self-adhesive resin cement. The null hypotheses
the performance of endodontically treated were that there is no significant difference in the
molars restored with lithium disilicate CAD/ fatigue resistance and failure mode of ETMs among
CAM complete crowns placed with self-adhe- the three different buildup designs tested in this in
sive resin cement. The 2-mm buildups were vitro study.
Carvalho & Others: Molars Restored With Lithium Disilicate Crowns 3
etching gel, Ivoclar Vivadent) for 20 seconds, rinsed, tion) or reparable failure (cohesive or cohesive/
cleaned in an ultrasonic bath in distilled water for 1 adhesive failure).
minute, and then silanized (RelyX Ceramic Primer, Load-to-Failure Testing of Surviving Specimens
3M ESPE, Seefeld, Germany) according to the (in the case where a Major Percentage of Specimens
manufacturer’s instructions. The prepared teeth Survived Fatiguing)—After the fatigue test, surviv-
were sandblasted with 27 lm aluminum oxide, ing specimens were axially loaded until failure or to
rinsed, and dried. The cement was applied to the a maximum load of 4500 N with a 10-mm composite
inner surface of the crowns, which were then seated resin sphere. The sphere had the same three-point
on the tooth with an approximate pressure of 70 N. occlusal contacts as in the fatigue test. The cross-
Cement excess was removed after a brief light head speed was 0.5 mm/min. The maximum post-
exposure (approximately 2 seconds) with a light- fatigue load before failure was recorded in Newtons,
emitting diode curing unit (Valo, Ultradent Prod- and mean values were calculated per group. After
ucts). Air-blocking barrier (KY Jelly, Johnson & load tests, the specimens were analyzed for one of
Johnson Inc, Montreal, QC, Canada) was used to the three failure modes as in the fatigue test.
cover all margins and additional polymerization was
carried out for 20 seconds per surface. The margins Statistical Analysis
were finished and polished with diamond ceramic
The fatigue resistance of the three groups was
polisher (CeramiPro Dialite W16DM, Brasseler),
compared using the life table survival analysis. At
polishing brush (soft bristle brush) with diamond
each time interval (defined by each load step), the
paste (Diamord Twist SCL, Premier, EC Represen-
number of specimens starting the interval intact and
tative, MDSS GmbH * Schiffgraben, Hannover,
the number of specimens fracturing during the
Germany), and buffed with a muslin rag wheel.
interval were counted. This allowed survival proba-
bility (%) to be calculated at each interval.
Testing
The postfatigue load-to-failure resistance of the
Fatigue Testing—Each specimen was stored in surviving specimens was compared using one-way
distilled water at ambient temperature for at least analysis of variance (ANOVA) (data tested normal)
24 hours after adhesive restoration placement. Mas- and the Tukey honestly significant difference test for
ticatory forces were then simulated with an artificial post hoc analyses. For all statistical analyses, the
mouth using closed-loop servo hydraulics (Mini level of significance was set at 95%. The data were
Bionix II, MTS Systems, Eden Prairie, MN, USA). analyzed with statistical software (MedCalc, version
Each specimen was placed into the load chamber and 11.0.1, MedCalc Software, Mariakerke, Belgium).
situated with a positioning device (sliding table). The
chewing cycle was simulated by an isometric contrac- RESULTS
tion (load control) applied through a composite resin
sphere (Filtek Z100, 3M ESPE) with a diameter of The survival rates after the fatigue test for ETMs with
10.0 mm. Because of the standardized occlusal 4-mm buildups, 2-mm buildups, and endocrowns were
anatomy, all specimens could be adjusted (through 100% (15 samples), 93% (14 samples), and 100% (15
the positioning device) in the same reproducible samples), respectively, and no statistical differences in
position with the sphere contacting the mesiobuccal, survival were found among them (p=0.98) (Table 1).
distobuccal, and palatal cusps (tripod contact). The There was only one failure during the fatigue test (a
load chamber was filled with distilled water to specimen with 2-mm buildup that fractured cohesive-
submerge the sample during testing. Cyclic load was ly, crown and buildup, at 1400 N). All specimens
applied at a frequency of 10 Hz, starting with a load of demonstrated limited wear of the crown material
200 N for 5000 cycles (preconditioning phase to (mainly glaze) but marked concave wear faceting on
guarantee predictable positioning of the sphere with the resin sphere antagonist (Figure 2).
the specimen), followed by stages of 400, 600, 800, Postfatigue load to failure averaged 3181 N for 4-
1000, 1200 and 1400 N at a maximum of 30,000 cycles mm buildups (15 specimens), 3759 N for 2-mm
each. Samples were loaded until fracture or to a buildups (12 specimens), and 3265 N for endocrowns
maximum of 185,000 cycles. The number of endured (14 specimens). One-way ANOVA revealed the
cycles and failure mode were recorded. After a two- higher load-to-failure resistance of 2-mm buildups
examiner agreement under optical microscopy, a (2-mm high) compared with the 4-mm buildup and
distinction was made between catastrophic failure endocrown designs (p=0.02), but no difference was
(crown/root fracture that would require tooth extrac- found between the 4-mm buildup and endocrown.
Carvalho & Others: Molars Restored With Lithium Disilicate Crowns 5
survived far beyond maximum masticatory human complete crowns placed with self-adhesive cement,
forces; one endocrown restoration and two restora- even though all three buildup designs exceeded all
tions with 2-mm buildup even survived the load-to- expectations. The use of 2-mm buildups was the most
failure test at 4500 N. The use of endocrown robust approach. Not only did it yield higher loads to
restorations presents the advantage of simplicity. failure than endocrown and 4-mm buildup restora-
On the other hand, a 2-mm buildup, besides tions, but it may also be useful to provide enhanced
providing the best fracture resistance, helps remove geometry, remove undercuts from the endodontic
possible retention from the endodontic preparation, preparation, and facilitate provisionalization.
offers some kind of positive geometry (ie, will
facilitate seating of the restoration), and decreases Acknowledgements
restoration thickness, which allows the blue light to This study was supported by CNPq 20092/2011-6, CAPES
pass through the indirect restoration to polymerize 3110/2010, and CAPES 4979/11-7. The authors thank 3M
the underlying resin cement.19 The 4-mm buildup ESPE, St Paul, Minnesota, for providing, Rely X Unicem 2
Automix, Filtek Z100, and Rely X Ceramic Primer.
restoration certainly provides even better provision-
al stabilization; however, this is at the cost of
Human Subjects Statement
polymerization shrinkage due to the large amount
of composite resin. This study was conducted in accordance with all the
provisions of the local human subjects oversight committee
After the fatigue test, it was observed that the guidelines and policies of the University of Southern Cal-
ifornia Health Sciences Campus Institutional Review Board.
buildup design could influence the load-to-failure The approval code for this study is HS-12-00278.
resistance of restored ETMs with lithium disilicate.
The 2-mm buildups performed better than endo- Conflict of Interest
crowns and 4-mm buildups. The explanation may lie
The authors of this manuscript certify that they have no
in the fact that in the 2-mm buildup, the restoration proprietary, financial, or other personal interest of any nature
is still relatively thick, providing additional resis- or kind in any product, service, and/or company that is
tance; also, the buildup itself acts as a bonded presented in this article.
connector (Optibond FL included) with the tooth.
(Accepted 27 March 2015)
Conversely, the combination of those two elements is
missing in the 4-mm buildup (which are a well REFERENCES
bonded but thinner restoration) and the endocrown 1. Ree M, & Schwartz RS (2010) The endo-restorative
(a thick restoration but lacks bonding because of the interface: Current concepts Dental Clinics of North
self-adhesive cement). America 54(2) 345-374.
Loaded restorations and resin sphere antagonists 2. Zicari F, Van Meerbeek B, Scotti R, & Naert I (2013)
showed well-defined wear facets, which supports the Effect of ferrule and post placement on fracture resistance
of endodontically treated teeth after fatigue loading
clinical relevance and validity of this simulation. It is Journal of Dentistry 41(3) 207-215.
always more realistic to simulate tooth contacts
3. Lima AF, Spazzin AO, Galafassi D, Correr-Sobrinho L, &
through wear facets distributing the load without Carlini-Junior B (2010) Influence of ferrule preparation
reaching the compressive limit of the tissues or with or without glass fiber post on fracture resistance of
restorative materials.13 Wear facets were predomi- endodontically treated teeth Journal of Applied Oral
nant on the antagonist (resin) sphere compared with Science 18(4) 360-363.
the lithium disilicate restoration itself. 4. Biacchi GR, & Basting RT (2012) Comparison of fracture
strength of endocrowns and glass fiber post-retained
Considering the results of this in vitro simulated conventional crowns Operative Dentistry 37(2) 130-136.
fatigue study on no-ferrule and no-post complete
5. Pissis P (1995) Fabrication of a metal-free ceramic
crowns, further research could be carried out to restoration utilizing the monobloc technique Practical
confirm that the use of a post is not required. Periodontics and Aesthetic Dentistry 7(5) 83-94.
However, it is difficult to envision how another
6. Lin CL, Chang YH, & Pai CA (2011) Evaluation of failure
restorative strategy could yield better results than risks in ceramic restorations for endodontically treated
those obtained with lithium disilicate ceramics premolar with MOD preparation Dental Materials 27(5)
without ferrules or posts. 431-438.
7. Lin CL, Chang YH, Chang CY, Pai CA, & Huang SF
CONCLUSION (2010) Finite element and Weibull analyses to estimate
failure risks in the ceramic endocrown and classical crown
It can be concluded that the buildup design influenced for endodontically treated maxillary premolar European
the performance of lithium disilicate CAD/CAM Journal of Oral Sciences 118(1) 87-93.
Carvalho & Others: Molars Restored With Lithium Disilicate Crowns 7
8. Magne P, & Knezevic A (2009) Simulated fatigue 14. DeLong R, Sakaguchi RL, Douglas WH, & Pintado MR
resistance of composite resin versus porcelain CAD/ (1985) The wear of dental amalgam in an artificial mouth:
CAM overlay restorations on endodontically treated A clinical correlation Dental Materials 1(6) 238-242.
molars Quintessence International 40(2) 125-133.
15. DeLong R, Douglas WH, Sakaguchi RL, & Pintado MR
9. Magne P, & Knezevic A (2009) Influence of overlay (1986) The wear of dental porcelain in an artificial mouth
restorative materials and load cusps on the fatigue Dental Materials 2(5) 214-219.
resistance of endodontically treated molars Quintessence
International 40(9) 729-737. 16. Magne P (2007) Efficient 3D finite element analysis of
dental restorative procedures using micro-CT data Dental
10. Fasbinder DJ (2002) Restorative material options for Materials 23(5) 539-548.
CAD/CAM restorations Compendium of Continuing Edu-
cation in Dentistry 23(10) 911-916, 918, 920 passim; quiz 17. Kishen A (2006) Mechanisms and risk factors for fracture
924. predilection in endodontically treated teeth Endodontic
Topics 13(1) 57-83.
11. DeLong R, & Douglas WH (1991) An artificial oral
environment for testing dental materials IEEE Transac- 18. Magne P, Carvalho AO, Bruzi G, Anderson RE, Maia HP,
tions on Bio-medical Engineering 38(4) 339-345. & Giannini M (2014) Influence of no-ferrule and no-post
12. Sakaguchi RL, Douglas WH, DeLong R, & Pintado MR buildup design on the fatigue resistance of endodontically
(1986) The wear of a posterior composite in an artificial treated molars restored with resin nanoceramic CAD/
mouth: A clinical correlation Dental Materials 2(6) CAM crowns Operative Dentistry 39(6) 595-602.
235-240. 19. Arrais CA, Giannini M, & Rueggeberg FA (2009) Kinetic
13. Kelly JR (1999) Clinically relevant approach to failure analysis of monomer conversion in auto- and dual-
testing of all-ceramic restorations Journal of Prosthetic polymerizing modes of commercial resin luting cements
Dentistry 81(6) 652-661. Journal of Prosthetic Dentistry 101(2) 128-136.