You are on page 1of 13

0.

51

1.82
0.41 7.09 2.53

3 END-WALL DETAIL
S-4 SCALE 1:40 mm

1.27
0.05 1.27
1.11 0.10
@ 0.05
1.11 0.10
with 7

0.10
SPACED @ with 4
@
with SPACED
SPACED

0.10
@

0.91
with
SPACED

0.51
TOP LINE OF
ROOF BEAM

0.40

0.40
RB-1 GB-1 RB-1 GB-1
RCB-1 RCB-1
DETAIL A DETAIL B
5 DETAIL OF R.C. GUTTER
S-4 SCALE 1:20 mm

PROJECT NAME AND LOCATION: SHEET CONTENTS: DESIGNED BY: REVIEWED: SUBMITTED: RECOMMENDED: APPROVED: SET NO. SHEET NO.
DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS
REGION - X CONSTRUCTION OF MULTI-PURPOSE
MISAMIS ORIENTAL FIRST DISTRICT ENGINEERING OFFICE BUILDING S 20
ODILON D. OCLARET JOSHUA B. DELA PEÑA HAROLD C. CAERMARE MARCELINOO.CABEGUIN,JR.,A.E.R. MARIVEL FRANCES L. ONG, A.E.R.
END WALL DETAIL
ENGINEER II ENGINEER II CHIEF, PLANNING AND DESIGN SECTION OIC-ASSISTANTDISTRICTENGINEER DISTRICT ENGINEER
OFFICE OF THE DISTRICT ENGINEER BRGY. MURALLON, GINGOOG CITY,
DETAIL OF R.C. GUTTER
DATE: DATE: DATE: DATE: DATE: 5 9 28
Brgy. 26, Gingoog City MISAMIS ORIENTAL
7.09 2.53
1

5 ±0.3 S-6
±0.3 5
0.51
±0.5
± 1 4
1 ±0.5
±0.5 1 S-6
1 ±0.5
±0.5 A A 1
1 ±0.5
±0.5 1
1 ±0.5
±0.5 1
A
1 A ±0.5
±0.5 1
1 ±0.5 1
±0.5 1
1.82

1 A ±0.5 S-7
±0.5 A C C 1
D D D ±0.3
5
±0.3 C 5

D D
A A
C C
D
C D
C
D
D

B B B B B B B
3 2
2
0.40

S-6 S-7
S-6

±1.20 ±1.20 ±1887 ±1.20 ±1.14 ±1.14 ±1.27 ±1.27

1 2 3 4 5
18.22
9.11 9.11 2 DETAIL ELEVATION OF TRUSS
4.55 4.55 4.55 4.55
S-5 SCALE 1:20 mm
SCHEDULE OF MEMBERS AND WELDS
1.21

RB-1 RB-1 RB-1 RB-1 SIZE OF WELDS


CB

CB

CB

CB
TRUSS MEMBERS
A RB-1 RB-1 RB-1 RB-1
MARK
SIZES THICKNESS
LENGTH, mm REMARKS
C1 C1 C1 C1 C1
L1 L2 L3
2∠s - 90 x 90 x 6 6mm FULL WELD
3.54

B 2∠s - 90 x 90 x 6 6mm 125 100 50


LRB-1 ( ABOVE ) RB-2

RB-2

RB-2

RB-2

RB-2
7.09

B L1
6mm GUSSET ⅊, Typical C 2∠s - 50 x 50 x 6 6mm 125 100 50

LRB-1 ( ABOVE )
RB-1 RB-1 RB-1 RB-1 STITCH WELD
TRUSS - 1

TRUSS - 1

TRUSS - 1

D 2∠s - 50 x 50 x 6 6mm 100 75 50

L3
3.54

TRUSS MEMBER
L2

C C1 RB-1 RB-1 C1 RB-1 C1 RB-1 C1


C1
NOTES ON ROOF CONSTRUCTION :
2.53

3 REFERENCE WELD DETAIL 1. IN ACTUAL FABRICATION OF STEEL TRUSSES, MEMBERS MEETING AT POINT SHALL HAVE
SCALE 1:10 m THEIR GRAVITY AXIS INTERSECT AS NEARLY AS PRACTICABLE AT A COMMON POINT.
D S-5 2. THE CONTRACTOR SHALL PROVIDE TEMPORARY ERECTION BRACINGS AND SHORING, AND
RB-1 RB-1 RB-1 RB-1
1.21

C1 C1 C1 C1 C1 MAKE ACTUAL MEASUREMENTS IN THE FIELD PRIOR TO FABRICATION/INSTALLATION OF


CB

CB

CB

CB

CB

ALL TRUSSES.
RB-1 RB-1 RB-1 RB-1 3. THE FABRICATOR/CONTRACTOR SHALL SUBMIT SHOP DETAILED DRAWINGS PRIOR TO
FABRICATION OF TRUSSES FOR APPROVAL OF THE DIRECTOR, BUREAUS OF DESIGN.

1 ROOF FRAMING PLAN


S-5 SCALE 1:100 mm

PROJECT NAME AND LOCATION: SHEET CONTENTS: DESIGNED BY: REVIEWED: SUBMITTED: RECOMMENDED: APPROVED: SET NO. SHEET NO.
DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS
REGION - X CONSTRUCTION OF MULTI-PURPOSE
MISAMIS ORIENTAL FIRST DISTRICT ENGINEERING OFFICE DETAIL ELEVATION OF TRUSS
BUILDING DETAILS OF MEMBER S AND WELDS S
ODILON D. OCLARET JOSHUA B. DELA PEÑA HAROLD C. CAERMARE MARCELINOO.CABEGUIN,JR.,A.E.R. MARIVEL FRANCES L. ONG, A.E.R. 21
ROOF FRAMING PLAN
ENGINEER II ENGINEER II CHIEF, PLANNING AND DESIGN SECTION OIC-ASSISTANTDISTRICTENGINEER DISTRICT ENGINEER
OFFICE OF THE DISTRICT ENGINEER BRGY. MURALLON, GINGOOG CITY,
REFERENCE WELD DETAIL
DATE: DATE: DATE: DATE: DATE: 6 9 28
Brgy. 26, Gingoog City MISAMIS ORIENTAL


W.M.
℄ BIGGER SIZE
℄ OF WASHER
W.M.
W.M. PURLINS
NUT

0.30
0.25

NEOPRENE
0.15 GASKET

⅊, 0.35
J-SHAPED BOLT
TYPICAL

0.25
⅊,
TYPICAL

0.25
W.M. W.M.

W.M. 0.20 0.20 W.M.


W.M.
0.30
5 ROOFING FIXER
1 DETAIL 1 2 DETAIL 2 3 DETAIL 3 4 DETAIL 4 S-6 NOT TO SCALE
SCALE 1:10 m SCALE 1:10 m SCALE 1:10 m SCALE 1:10 m
S-6 S-6 S-6 S-6

FULL 6mm 0.05 0.10


FULL 6mm 0.05 0.10 FULL 6mm 0.05 0.10 WELD T.C.
WELD WELD

6mm
6mm 6mm TYP.
TYP. TYP.

0.050.05
0.05 0.10 0.05

0.05 0.10 0.05


℄ ℄
FULL
FULL FULL
WELD 6mm
⅊,
WELD 6mm WELD 6mm
16mm Ø STEEL CROSS-BRACINGS,
W/ STANDARD TURN-BUCKLE

ALONG GRID LINE A & C


T.C. T.C.
16mm Ø STEEL CROSS-BRACINGS, 16mm Ø STEEL CROSS-BRACINGS, ROOFING
W/ STANDARD TURN-BUCKLE ⅊, W/ STANDARD TURN-BUCKLE ⅊,

AT END WALL AT APEX OF TRUSS


6 DETAIL CONN. OF CROSS-BRACING
SCALE 1:10 m
S-6
0.13
0.13
0.03 0.03
0.15
0.03 0.03 0.01
⅊ JOINT CONNECTOR, FULL 6mmØ J-BOLT SPACED AS SHOWN AT ALL PURLINS
WELD TO TOP CHORD ⅊ JOINT CONNECTOR, FULL
WELD TO TOP CHORD
0.03

0.03

ROO
FIN
0.15
0.050.05

0.15
0.050.05

0.15
G

T.C. T.C.

T.C. 9 ISOMETRIC VIEW OF CONNECTION OF ROOFING TO PURLINS


S-6 NOT TO SCALE

7 DETAIL CONN. OF PURLIN TO TOP CHORD


SCALE 1:10 m
8 DETAIL OF PURLIN SPLICE
S-6 SCALE 1 :10 m
S-6
PROJECT NAME AND LOCATION: SHEET CONTENTS: DESIGNED BY: REVIEWED: SUBMITTED: RECOMMENDED: APPROVED: SET NO. SHEET NO.
DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS
REGION - X DETAIL 1,2,3 & 4
CONSTRUCTION OF MULTI-PURPOSE DETAIL CONN. CROSS -BRACING
MISAMIS ORIENTAL FIRST DISTRICT ENGINEERING OFFICE BUILDING ROOFING FIXER S 22
DETAIL CONN. OF PURLIN TO TOP CHORD ODILON D. OCLARET JOSHUA B. DELA PEÑA HAROLD C. CAERMARE MARCELINOO.CABEGUIN,JR.,A.E.R. MARIVEL FRANCES L. ONG, A.E.R.
ENGINEER II ENGINEER II CHIEF, PLANNING AND DESIGN SECTION OIC-ASSISTANTDISTRICTENGINEER DISTRICT ENGINEER
OFFICE OF THE DISTRICT ENGINEER BRGY. MURALLON, GINGOOG CITY,
DETAIL OF PURLIN SPLICE
ISOMETRIC VIEW OF CONNECTION OF ROOFING DATE: DATE: DATE: DATE: DATE: 7 9 28
Brgy. 26, Gingoog City MISAMIS ORIENTAL
J BOLTS @ 0.25
EVERY 3RD CORR. 0.15

.LC PURLIN

LC PURLIN
320±
ROOF PANEL SIDE LAP DETAIL
SCALE 1:10M

JOINT CONNECTOR,
FULL WELD TO ANGULAR BASE PLATE

230±

0.25

LRB-1

6mm THK. GUSSET ⅊



RB-1 RB-1
⅊, W/ 250 x 300 x 16mm THK. STEEL BASE ⅊, W/
2 - 20mm Ø x 300mm LONG ANCHOR 2 - 20mm Ø x 300mm LONG ANCHOR BOLTS;
BOLTS EACH SIDE
DETAIL CONN. OF PURLINS TO END-WALL
0.49 mm (BMT) LONGSPAN SCALE 1:10 m
.PRE-PAINTED CORR. ROOFING
(0.50 mm TCT)
ELEVATION 2-1/2

19mm CORR. (MIN)


ELEVATION SIDE LAP

R. C. G U T T E R
RB-1 PANEL 1 PANEL 2
RB-1

12mm
. Ø SAGRODS W/ STANDARD NUT &
WASHER
0.25
0.13 J-BOLT SPACING
0.060.06 0.08 0.09 0.08
SCALE 1:10M

0.05
℄ .
0.30

0.30

2∠s - 50 x 50 x 5mm W.M. 0.05 .


⅊,
W/ 2 - 20mm Ø x 300mm LONG .
ANCHOR BOLTS 250 x 300 x 16mm THK. STEEL BASE ⅊, W/
2 - 20mm Ø x 300mm LONG ANCHOR BOLTS;
EACH SIDE

P L A N
P L A N
1 DETAIL OF TRUSS ANCHORAGE @ GRID LN. A & D
SCALE 1:10 m 2 DETAIL OF TRUSS ANCHORAGE @ GRID LN. C
SCALE 1:10m

DETAIL OF PURLIN TO SAG ROD CONNECTION


SCALE 1:10M

PROJECT NAME AND LOCATION: SHEET CONTENTS: DESIGNED BY: REVIEWED: SUBMITTED: RECOMMENDED: APPROVED: SET NO. SHEET NO.
DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS
DETAIL OF TRUSS ANCHORAGE @ GRID LN. A & D
REGION - X CONSTRUCTION OF MULTI-PURPOSE DETAIL OF TRUSS ANCHORAGE @ GRID LN. C
MISAMIS ORIENTAL FIRST DISTRICT ENGINEERING OFFICE BUILDING DETAIL CONNECTION OF PURLINSTO END-WALL
S 23
J-BOLT SPACING ODILON D. OCLARET JOSHUA B. DELA PEÑA HAROLD C. CAERMARE MARCELINOO.CABEGUIN,JR.,A.E.R. MARIVEL FRANCES L. ONG, A.E.R.
ROOF PANEL SIDE LAP DETAIL ENGINEER II ENGINEER II CHIEF, PLANNING AND DESIGN SECTION OIC-ASSISTANTDISTRICTENGINEER DISTRICT ENGINEER
OFFICE OF THE DISTRICT ENGINEER BRGY. MURALLON, GINGOOG CITY, DETAIL OF PURLIN TO SAGROD CONNECTION DATE: DATE: DATE: DATE: DATE: 8 9 28
Brgy. 26, Gingoog City MISAMIS ORIENTAL
B

0.35 0.00 0.35


1.42

A 0.10 1.21 0.10

0.20
0.10 0.30
150mm THICK CONCRETE WALL

0.56
150mm THICK CONCRETE WALL

CONC. PLATFORM
FINISH FLOOR LINE

FINISH GRADE LINE

WF-2 WF-2
WF-1 WF-1 WF-1 WF-1
A B

5 DETAILS OF HAND WASH


5 DETAILS OF LAVATORY @ TOILET
S-8 SCALE 1:20 mm
S-8 SCALE 1:20 mm 0.15

0.61
0.18 0.18
0.10 380 0.10
typical

0.100.100.10
2 - 10mm Ø
100mm THK. WELL-COMPACTED
300

GRAVEL FILL

10mm Ø @ 300mm O.C.,


0.10
0.10 0.51 0.10 0.30 0.10 0.15 1.57 0.10
530

0.40
0.10 0.25

0.10
WF-2
DETAIL SECTION B-B

1.62

0.20
0.10 0.30
0.76
0.100.100.10

0.15
0.35

CORRIDOR
FINISH FLOOR LN.

CORRIDOR
0.86

0.40
300

FINISH FLOOR LN.

300 VARIES
FINISH GRADE LN.

CONC. PLATFORM NATURALGRADE LN.


FINISH FLOOR LINE
WF-2
FINISH GRADE LINE

DETAIL SECTION A-A

2 DETAIL - 4 (CONC. SEATING DETAIL) 3 DETAIL OF TOILET PARTITION


1 DETAILS OF LAVATORY (HANDWASH)
S-8
S-8 SCALE 1:20 mm S-8

PROJECT NAME AND LOCATION: SHEET CONTENTS: DESIGNED BY: REVIEWED: SUBMITTED: RECOMMENDED: APPROVED: SET NO. SHEET NO.
DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS
REGION - X CONSTRUCTION OF MULTI-PURPOSE DETAILS OF LAVATORY
MISAMIS ORIENTAL FIRST DISTRICT ENGINEERING OFFICE BUILDING
DETAIL OF CONNECTION SEATING DETAIL
WALL FOOTING -2 S 24
ODILON D. OCLARET JOSHUA B. DELA PEÑA HAROLD C. CAERMARE MARCELINOO.CABEGUIN,JR.,A.E.R. MARIVEL FRANCES L. ONG, A.E.R.
DETAIL OF TOILET PARTITION
ENGINEER II ENGINEER II CHIEF, PLANNING AND DESIGN SECTION OIC-ASSISTANTDISTRICTENGINEER DISTRICT ENGINEER
OFFICE OF THE DISTRICT ENGINEER BRGY. MURALLON, GINGOOG CITY,
DETAIL OF HANDWASH
DETAILS OF LAVATORY AT TOILET
DATE: DATE: DATE: DATE: DATE: 9 9 28
Brgy. 26, Gingoog City MISAMIS ORIENTAL
P. PLUMBING

CONSTRUCTION OF MULTI-PURPOSE BUILDING


BRGY. MURALLON, GINGOOG CITY, MISAMIS ORIENTAL
1 2 2' 3 3' 4 5

SEPTIC VAULT
(SEE DETAIL)

100 mm Ø PVCSP
50 mm Ø PVCVP
100 mm Ø PVCDS 50 mm Ø PVCVS
(TYPICAL)

100 mm Ø PVCDP 100 mm Ø PVCDP 100 mm Ø PVCDP


CO
50 mm Ø PVCVS

DP
CO
CO

VC
ØP
0

ROOF LINE
FD LAV

mm
LAV FD
ROOF LINE ABOVE WC WC GRAVEL BED (RIVER STONE)
0
10

A CO

SD

50 mm Ø PVCVP
50 mm Ø PVCWP
SD
CONCRETE FLATFORM
100 mm Ø PVCDP

SD
HANDWASHING

SD
1 2 2' 3 3' 4 5
B CO

50 mm Ø PVCVTR
150 mm Ø PVCDP

(PROVIDE STAINLESS STEEL PROTECTION SCREEN)


C O R R I D O R
LINE OF CORRIDOR & ROOF

C 100 mm Ø PVCDS
RAMP UP
(TYPICAL)
UP UP

150 mm Ø PVCDP 100 mm Ø PVCDP 100 mm Ø PVCDP 100 mm Ø PVCDP LINE OF PARAPET
DD DD
DD DD

A
1 FLOOR PLAN (SEWER LINE & DRAINAGE LAYOUT)
P-1 SCALE: 1:100 M 50 mm Ø PVCVTR
(PROVIDE STAINLESS STEEL
PROTECTION SCREEN)

C
DD DD DD DD

2 ROOF PLAN (SEWER LINE & DRAINAGE LAYOUT)


P-1 SCALE: 1:100 M

PROJECT NAME AND LOCATION: SHEET CONTENTS: DESIGNED BY: REVIEWED: SUBMITTED: RECOMMENDED: APPROVED: SET NO. SHEET NO.
DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS
REGION - X CONSTRUCTION OF MULTI-PURPOSE
MISAMIS ORIENTAL FIRST DISTRICT ENGINEERING OFFICE FLOOR PLAN
BUILDING (SEWER AND DRAINAGE LAYOUT) P 25
JEAN R. TIOZON JOSHUA B. DELA PEÑA HAROLD C. CAERMARE MARCELINOO.CABEGUIN,JR.,A.E.R. MARIVEL FRANCES L. ONG, A.E.R.
ROOF PLAN ENGINEER II ENGINEER II CHIEF, PLANNING AND DESIGN SECTION OIC-ASSISTANTDISTRICTENGINEER DISTRICT ENGINEER
OFFICE OF THE DISTRICT ENGINEER BRGY. MURALLON, GINGOOG CITY, (SEWER AND DRAINAGE LAYOUT) DATE: DATE: DATE: DATE: DATE: 1 19 28
Brgy. 26, Gingoog City MISAMIS ORIENTAL
1 2 2' 3 3' 4 5

20 mm Ø PPRC CWL 20 mm Ø PPRC CWL

GV GV
25 mm Ø PPRC CWL CV GV

WM
0

ROOF LINE
ROOF LINE ABOVE LAV LAV ROOF LINE ABOVE
WC WC

A GV

HB

HB
20 mm Ø PPRC CWL
HB

CONCRETE FLATFORM
HB

HB

HB

HB

HANDWASHING
HB

HB

B
HB

PLUMBING NOTES:
1. GRADES OF HORIZONTAL PIPING
RUN ALL HORIZONTAL PIPINGS IN PERFECT ALIGNMENT AND AT A FORM
C O R R I D O R
GRADE OF NOT LESS THAN TWO PERCENT (2%).
LINE OF CORRIDOR & ROOF

C 2. CHANGE IN DIRECTION
ALL CHANGE IN DIRECTION SHALL BE MADE BY APPROPRIATE USE OF
RAMP UP UP UP
FORTY FIVE DEGREES (45°) WYES, LONGSWEEP QUARTER BEND, SIX-EIGHT
OR SIXTEENTH BENDS. WHEN THE CHANGE OF FLOW IS FROM HORIZONTAL
TO VERTICAL, 1/8 BEND COMBINATION MAYBE USED ON VERTICAL STACKS
AND SHORT QUARTER BENDS MAYBE USED ON WASTE LINE. TEE AND
CROSSES MAYBE USED IN VENT PIPES.

1 FLOOR PLAN (WATERLINE LAYOUT) 3. PROHIBITED FITTINGS


SCALE: 1:100 M NO DOUBLE HUB OR TEE BRANCH SHALL BE USED ON HORIZONTAL WASTE
P-2 LINES. THE DRILLINGS AND TAPPINGS OF HOUSE DRAIN, WASTE OR VENT
PIPES AND USE OF SADDLE HUB AND BEND ARE PROHIBITED.

4. SLEEVES
PROVIDE PIPE SLEEVES AT WALLS, COLUMNS OR SLABS ONE SIZE BIGGER
THAN THE ACTUAL SIZE PASSING THROUGH THE WALLS, COLUMNS OR UNDER
SLAB TO PROTECT PIPE FROM BREAKAGE.

PLUMBING LEGEND 5. PIPE CLEAN-OUTS


PIPE CLEAN-OUTS ARE REQUIRED UNDER THE FOLLOWING CONDITIONS:
a. EVERY CHANGE IN HORIZONTAL DIRECTIONS EXCEEDING TWENTY-TWO
CO CLEAN OUT PVCDP POLYVINYL CHLORIDE DRAIN PIPE (SERIES 1000) AND ONE-HALF DEGREES (22 1/2°).
(ASTM D2729 / ASTM D3311, ISO 4435 / ASTM D2564) b. ONE AND ONE-HALF METERS (1.50 m) INSIDE THE PROPERTY LINE BEFORE
CV CHECK VALVE THE HOUSE DRAINAGE CONNECTION.
PVCDS POLYVINYL CHLORIDE DOWNSPOUT (SERIES 1000) c. EVERY FIFTEEN METERS (15.00 m) IN HORIZONTAL RUN OF PIPES.
DD DECK DRAIN (ASTM D2729 / ASTM D3311, ISO 4435 / ASTM D2564) d. AT THE END OF ANY HORIZONTAL PIPE LINES.

FD FLOOR DRAIN PVCSP POLYVINYL CHLORIDE SOIL PIPE (SERIES 1000) 6. THE DIGESTION CHAMBER OF SEPTIC VAULT MUST BE WATERPROOFED.
(ASTM D2729 / ASTM D3311, ISO 4435 / ASTM D2564)
HB HOSE BIBB 7. NOT LESS THAN 300 mm OF AIR SPACE MUST BE LEFT BETWEEN THE TOP OF
PVCVP POLYVINYL CHLORIDE VENT PIPE (SERIES 600) THE SEWAGE AND THE UNDER PART OF THE VAULT ROOF SLAB.
GV GATE VALVE (ASTM D2729 / ASTM D3311, ISO 4435 / ASTM D2564)
8. NO SEPTIC VAULT MUST BE CONSTRUCTED UNDER THE BUILDING.
LAV LAVATORY PVCVS POLYVINYL CHLORIDE VENT STACK (SERIES 600)
(ASTM D2729 / ASTM D3311, ISO 4435 / ASTM D2564) 9. ALL PLUMBING WORKS SHALL BE DONE BY A LICENSED MASTER PLUMBER
MH MANHOLE AND A LICENSED PLUMBING CONTRACTOR.
PVCVTR POLYVINYL CHLORIDE VENT THROUGH ROOF (SERIES 600)
SD SINK DRAIN (ASTM D2729 / ASTM D3311, ISO 4435 / ASTM D2564)

WC WATER CLOSET PVCWP POLYVINYL CHLORIDE WASTE PIPE (SERIES 1000)


(ASTM D2729 / ASTM D3311, ISO 4435 / ASTM D2564)
WM WATER METER

PPRC CWL POLYPROPYLENE RANDOM COPOLYMER COLD WATER LINE, TYPE 3, PN 16


(ISO 15874 / JOINING BY SOCKET FUSION)

PROJECT NAME AND LOCATION: SHEET CONTENTS: DESIGNED BY: REVIEWED: SUBMITTED: RECOMMENDED: APPROVED: SET NO. SHEET NO.
DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS
REGION - X CONSTRUCTION OF MULTI-PURPOSE FLOOR PLAN (WATER LINE LAYOUT)
MISAMIS ORIENTAL FIRST DISTRICT ENGINEERING OFFICE BUILDING PLUMBING LEGENDS P 26
JEAN R. TIOZON JOSHUA B. DELA PEÑA HAROLD C. CAERMARE MARCELINOO.CABEGUIN,JR.,A.E.R. MARIVEL FRANCES L. ONG, A.E.R.
PLUMBING NOTES CHIEF, PLANNING AND DESIGN SECTION OIC-ASSISTANTDISTRICTENGINEER
ENGINEER II ENGINEER II DISTRICT ENGINEER
OFFICE OF THE DISTRICT ENGINEER BRGY. MURALLON, GINGOOG CITY, DATE: DATE: DATE: DATE: DATE: 2 19 28
Brgy. 26, Gingoog City MISAMIS ORIENTAL
150 mm Ø PVCSP
TO NEAREST SEWER LINE
(VERIFY SITE CONDITION)

DD

100 mm Ø PVCDS SEPTIC VAULT


(SEE DETAIL)

5 5 GV
DD CV
WM
CO
4 100 mm Ø PVCDS
PV
CS
P
4 WL
mØ CC
3' DD
CB
10 0m DD
3' m mØ
P PR

25
3 100 mm Ø PVCDS
3 BO
VE
EA

2'
CO
50 mm Ø PVCVTR DP LIN
VC SP
2'
DD OF
RO
(PROVIDE STAINLESS STEEL ØP C
PROTECTION SCREEN) 0 mm Ø PV 20 mm Ø PPRC CWL GV
1 0 m
2 DD
32 mm Ø PVCVAC
50 mm Ø PVCVS
10 0 m
2 20 mm Ø PPRC CWL GV WC
CB LAV
DD
50 mm Ø PVCVP P LAV
CD
Ø PV WC
mm
1 100 mm Ø PVCDS
100 FD LAV 1 NE) O VE
CB WC S TO E AB
CO ER
LAV
DD
(RIV OF
LIN UP
FD ED RO
LB
WC AVE
50 mm Ø PVCVTR P GR
CD R
(PROVIDE STAINLESS STEEL PV R
PROTECTION SCREEN) mØ O O F
10 0m AB
OV
E
D UP C DP CB E HB D &R
OO
UP
FL
INE I Ø PV LIN
OF HB
HB
I R IDO
R
50 mm Ø PVCVS O RO OR
RO
mm R C
DP

CB R HB OF
100 GV E
HB R LIN
PVC

R 100 mm Ø PVCDS HB
O HB O
OF CB
DP

RO HB C
C R& UP C CO
E
OF
LIN
RIDO
Ø PV NC
RE
HB
UP
100 m

SD OR HB MP
TE
mm
RO
CO
SD LIN
E OF
C
100 A F LA
T FO HANDW
RM ASHIN
RA

CB
20 mm Ø PPRC CWL G

CB P
100
CO
NC
SD
P V CD
ØP
RE U
MP
mm TE FL
A 50 mm Ø PVCWP
Ø P A TFO
VC R
HA
ND
WA
SD RA

100
mm 100 mm Ø PVCDS
DP M SH
ING

50 mm Ø PVCVP
CO
CB
B
P
CD
CB
150
mm mm
ØP
V
C 2 ISOMETRIC DIAGRAM (WATER LINE LAYOUT)
Ø 150
B PV
CD
P
P-3 SCALE: NTS

0.48
C CB
2-16 mm Ø HANDLE BARS
INLET

10 mm Ø BARS, E.W.
150 mm Ø PVCDP
TO NEAREST DRAINAGE OUTLET

0.10
(VERIFY SITE CONDITION)

100 mm Ø PVC DOWNSPOUT


0.04 0.40 0.04
100 mm Ø PVCDP
1 ISOMETRIC DIAGRAM (SEWER AND DRAINAGE LAYOUT) REMOVABLE CB COVER (2 % SLOPE)
0.48
150 mm Ø PVCDP
(2 % SLOPE)
SCALE: NTS 0.06 0.06
P-3 100 mm Ø PVC DOWNSPOUT

0.06
0.10
0.06 0.06
0.04 0.04 FIN. GRADE LINE
INLET OUTLET
OPENING (VERIFY)

0.60
0.40
VARIES0.10
100 mm THK. CHB WALL W/ 10 mm Ø
HORIZONTAL BARS @ 600 mm O.C

0.10
(TYPICAL)

0.06
1100 (VERIFY)

0.15
100 mm Ø PVCDP REMOVABLE R.C.
(2 % SLOPE) 150 mm Ø PVCDP 0.10 0.40 0.10 COVER WITH 2-16 mm Ø
(2 % SLOPE) HANDLE BAR

0.60
OUTLET
INLET DETAIL PLAN
0.20

0.10
0.10

0.10 0.40 0.10 DETAIL OF CATCH BASIN


4-12 mm Ø BARS, E.W.
0.60 SCALE 1:20 MTS

DETAIL SECTION

PROJECT NAME AND LOCATION: SHEET CONTENTS: DESIGNED BY: REVIEWED: SUBMITTED: RECOMMENDED: APPROVED: SET NO. SHEET NO.
DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS
REGION - X CONSTRUCTION OF MULTI-PURPOSE ISOMETRIC DIAGRAM
MISAMIS ORIENTAL FIRST DISTRICT ENGINEERING OFFICE BUILDING (SEWER & DRAINAGE LAYOUT) P 27
JEAN R. TIOZON JOSHUA B. DELA PEÑA HAROLD C. CAERMARE MARCELINOO.CABEGUIN,JR.,A.E.R. MARIVEL FRANCES L. ONG, A.E.R.
ISOMETRIC DIAGRAM ENGINEER II ENGINEER II CHIEF, PLANNING AND DESIGN SECTION OIC-ASSISTANTDISTRICTENGINEER DISTRICT ENGINEER
OFFICE OF THE DISTRICT ENGINEER BRGY. MURALLON, GINGOOG CITY, (WATER LINE LAYOUT) DATE: DATE: DATE: DATE: DATE: 3 19 28
Brgy. 26, Gingoog City MISAMIS ORIENTAL
100 mm Ø PVCSP 100 mm Ø PVCSP 100 mm Ø PVCSP 100 mm Ø PVCSP
0.61 0.61 0.61
0.61 0.61 0.61 HEAVY DUTY
HEAVY DUTY BRASS CO COVER
BRASS CO
MH MH MH (TYPICAL)
MH MH MH COVER (TYPICAL)
CO CO FIN. GRADE LINE CO CO CO
FIN. GRADE LINE CO

0.46 0.15
0.46 0.15

0.35

0.40

0.46
0.35

0.40

0.46
AIR SPACE (350 mm)
Level of scum
OUTLET OUTLET
TO NEAREST

1.87
TO NEAREST

1.87
SEWER LINE
LEACHING
SEWER LINE DIGESTION CHAMBER LEACHING LEACHING
DIGESTION CHAMBER LEACHING (VERIFY)
(VERIFY)
CHAMBER CHAMBER CHAMBER
PROVIDE HOT APPLIED ASPHALT WATERPROOPING CHAMBER

0.76
962 0.80 0.80
℄ 2% SLOPE
GRAVEL BED GRAVEL BED ℄ 2% SLOPE

0.15
0.15
16 mm Ø EXTRA BARS AT 150 mm THK. R. C. WALL WITH
150 mm THK. +/- 600 mm O.C. 16 mm Ø HOR. BARS AT 250 mm
R. C. WALL (TYPICAL) 0.15 3.00 0.15 1.01 0.15 1.01 0.15 O.C. AND 16 mm Ø VERT. BARS
0.15 3.00 0.15 1.01 0.15 1.01 0.15
5.63 AT +/-300 mm O.C. (TYPICAL)
5.63 16 mm Ø BARS AT 259 mm O.C.
CUT-OFF ALTERNATE @ 462 mm 150 mm THK. BOTTOM SLAB
150 mm THK. BOTTOM SLAB FROM FACE OF SUPPORT
(TYPICAL) (TYPICAL)
DETAIL SECTION A 100 mm THK. COMPACTED GRAVEL FILL
DETAIL SECTION A 100 mm THK. COMPACTED
16 mm Ø LONGITUDINAL BARS GRAVEL FILL
AT 269 mm O.C. 7600
0.15 3.00 0.15 1.01 0.15 1.01 0.15

5.63 1-16 mm Ø EXTRA DIAGONAL BAR


0.15 3.00 0.15 1.01 0.15 1.01 0.15 TYPICAL AT EVERY MH CORNERS

0.15

0.15
TOP SLAB R. C. BEAM LEACHING CHAMBER
(TYPICAL) (TYPICAL)
CO CO
0.15

S-2
CO CO
S-1
A MH MH

0.61
2.83

2.53

2.53
DIGESTION CHAMBER

MH MH MH A 150 mm Ø PVCSP

0.61
2.83
2.53

OUTLET
CO
S-2 TO NEAREST
SEWER LINE
(VERIFY)

0.15

0.15
CO
OUTLET 0.61
TO NEAREST
0.15

SEWER LINE LEACHING CHAMBER


0.61
(VERIFY)
100 mm Ø PVCSP
B
100 mm Ø PVCSP
C (TYPICAL)
INLET INLET
150 mm Ø PVCSP

100 mm Ø PVCSP
B C
INLET 100 mm Ø PVCSP INLET DETAIL PLAN (TOP SLAB)
DETAIL PLAN (TOP SLAB) 2 DETAIL OF SEPTIC VAULT (with REINFORCING BARS)
SCALE 1:40 MTS.
P-4
3 DETAIL OF SEPTIC VAULT
0.61 SCALE 1:40 MTS.
1-16 mm Ø BAR (TYP.)
P-4 16 mm Ø HOR. BARS @ 250 mm O.C. 0.61 1-16 mm Ø BAR (TYP.)
MH 16 mm Ø VERT. BARS @ +/- 300 mm O.C. MH
(TYP.)
CO FIN. GRADE LINE CO
FIN. GRADE LINE
0.300.15
0.46

16 mm Ø HOR. BARS @ INLET SCHEDULE OF TOP SLAB REINFORCEMENT


250 mm O.C.16 mm Ø VERT.
LEACHING BARS @ +/- 300 mm O.C. (TYP.) TOP SLAB
2.18
1.87

OUTLET MARK
TO NEAREST CHAMBER DIGESTION CHAMBER
SEWER LINE
SHORT DIRECTION LONG DIRECTION
(VERIFY) 462 462
0.76

0.76
16 mm Ø BARS @ 195 mm O. C. BENT-UP 2 OUT 16 mm Ø BARS @ 190 mm O. C.
S-1
OF 3 @ L/4 FROM FACE OF SUPPORT TEMPERATURE BARS
16 mm Ø BARS AT 259 mm O.C. 16 mm Ø EXTRA BARS 16 mm Ø BARS AT 259 mm O.C.
CUT-OFF ALTERNATE @ 462 mm 1575 16 mm Ø EXTRA BARS
AT +/- 600 mm O.C. CUT-OFF ALTERNATE @ 462 mm 1575 AT +/- 600 mm O.C.
FROM FACE OF SUPPORT FROM FACE OF SUPPORT
0.15 2.53 0.15 16 mm Ø LONGITUDINAL 0.15 2.53 0.15 16 mm Ø LONGITUDINAL
2.83 BARS AT 269 mm O.C. 2.83 BARS AT 269 mm O.C. S-2 16 mm Ø BARS @ 225 mm ON CENTER 16 mm Ø BARS @ 190 mm ON CENTER

DETAIL SECTION C DETAIL SECTION B

PROJECT NAME AND LOCATION: SHEET CONTENTS: DESIGNED BY: REVIEWED: SUBMITTED: RECOMMENDED: APPROVED: SET NO. SHEET NO.
DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS
REGION - X CONSTRUCTION OF MULTI-PURPOSE SCHEDULE OF SLAB REINFORCEMENT
MISAMIS ORIENTAL FIRST DISTRICT ENGINEERING OFFICE BUILDING DETAIL OF CATCH BASIN P 28
JEAN R. TIOZON JOSHUA B. DELA PEÑA HAROLD C. CAERMARE MARCELINOO.CABEGUIN,JR.,A.E.R. MARIVEL FRANCES L. ONG, A.E.R.
DETAIL OF SEPTIC VAULT
ENGINEER II ENGINEER II CHIEF, PLANNING AND DESIGN SECTION OIC-ASSISTANTDISTRICTENGINEER DISTRICT ENGINEER
OFFICE OF THE DISTRICT ENGINEER BRGY. MURALLON, GINGOOG CITY, DATE: DATE: DATE: DATE: DATE: 4 19 28
Brgy. 26, Gingoog City MISAMIS ORIENTAL
LIGHTING LAY-OUT SCHEDULE OF LOADS & COMPUTATIONS
Scale 1:100 MTS. SPECIFICATIONS OF 2 – 18 WATTS
PANEBOARD LPA MAIN: 60AF, 40AT, 2-Pole, 240 Volts, 10KAIC, Bolt-on TQC Breaker
T8 LED FLUORESCENT TUBE
1600mm 1600mm

WITHOUT BALLAST & STARTER


CKT. PROTECTION

1.70m
1 1 CKT. LOAD Circuit Breaker, Bolt-on or Miniature CB
P DESCRIPTION OF LOADS (V) (A) SIZE OF CKT. HOMERUN CONDUCTOR
1 1 No. (V-A)
AF P AT KAIC

1 LIGHTING OUTLETS 17 0 0 1,700 230 7.39 60 2 15 10 2-#3.5mm2, THHN/THWN Stranded Wire in 15mm dia. PVC Pipe

CONVENIENCE 2-#3.5mm2, THHN/THWN Stranded Wire and 1-#2.0mm 2,


a b c a b c 2 0 4 0 1,440 230 6.26 60 2 15 10
OUTLETS THHN/THWN Stranded wire(GROUND) in 15mm dia. PVC Pipe
LPA a,b,& c
CEILING FAN 2-#3.5mm2, THHN/THWN Stranded Wire and 1-#2.0mm 2,
3 0 0 8 800 230 3.48 60 2 15 10
e
OUTLETS THHN/THWN Stranded wire(GROUND) in 15mm dia. PVC Pipe
a nc
a b c a b c 1 ntr
eE 4 SPARE 0 0 1 1,000 230 4.35 60 2 20 10
LPA rvic
Se
LPA M Total Power in Volt-Ampere & Load
4,940 230 21.48 60 2 40 10 2-#8.0mm2, THW Stranded Wire and 1-#5.5mm2, THHN/THWN
2ab 1c Current Stranded wire(GROUND) in 3/4" dia. EMT Pipe Double(2)-T8 LED Fluorecent Tubes, 18Watts
2ab 1c
2de
each (Replacement of 36Watts Tube), Daylight,
1f
f d e SERVICE ENTRANCE: 2-#8.0 mm2, THW, Stranded Wire in 3/4" diameter EMT Pipe 220/240Volts, 50/60Hz, 1800 to 2000 Lumens
(IL)Total Load
IT 21.48 AMPERES per tube, Average Life per tube: 20,000 hrs,
Current
MAIN PROTECTION: 60AF, 40AT, 2-Pole, 240 Volts, 10KAIC, Bolt-on Circuit Breaker using Industrial Type double-tube luminaire,
(Size:1180x125x65mm) with-out ballast &
starter
CL-100, Industrial Type Kilowatt-
Hour Meter Base with Metal
Enclosure
GENERAL NOTES & SPECIFICATIONS LEGEND:
SYMBOLS DESCRIPTION
1. All works and materials to be used shall be in accordance with the
PANEL BOARD LPA:
latest edition of Philippine Electrical Code, R.A. 7920 , LGU local 1-PHASE, 240-VOLTS, 2-WIRES+GROUND (2W+G),
ordinances and MORESCO II. LPA NEMA-1 METAL ENCLOSURE,HINGED TYPE, WITH
LOCKED & FLUSH TYPE WALL MOUNTED
Refer to Riser Diagram for the details)
2. The wiring conductors and materials to be used shall be new and of
approved type for both location and purpose. Bolt-on or Mini Type Circuit Breaker, Individual trip ratings
shall be referred to Power Riser Diagram & Schedule of
Loads & Computations
POWER LAY-OUT 3. The wiring installation shall be concealed using a minimum size of
Scale 1:100 MTS.
PVC pipe of 15mm diameter and an electrical conductor of 2.0 mm2 1 3Watts,E-27, Daylight LED Bulb, 200 to 250 lumens,
THW and THHN/THWN Stranded Wire. 220/240V, 50/60hz, Average Life: 20,000 hrs(Toilet)
1600mm 1600mm

4. There shall be one(1) service drop to the building. Service shall 9Watts,E-27, Daylight LED Bulb, 700 to 800 lumens,
1.70m

be 230-Volts, single phase and 60 hertz of frequency.


220/240V, 50/60hz, Average Life: 20,000
hrs(Hallway)
2CD 2CD

5. Grounding system shall be provided to all power circuit as per


Circuit Homerun Conductor
C D C C Sizes of homerun conductor shall be referred to Schedule of
Philippine Electrical Code requirement.
D
F F F F loads & Computations

240v 240v

240v 240v
6. Mounting height of wiring devices shall be as follows: 2- Gang Conv. Outlet, 3-prongs(For grounding),
240v Flush Type,16A, 250V, Universal Type, WIDE
F F F F SERIES
a. Light switch - 1.30 m above finish floor
A
2
B A B
LPA
3
1- Gang Switch, 10A, 250V Flush Type
2AB 2AB
LPA LPA Service Entrance
b. Convenience Outlet - 0.30 m above finish floor 1

c. Panel board - 1.50 m above finish floor


2- Gang Switch,10A, 250V, Flush Type
2
d. Ceiling Fan Rotary Switch - 1.30 m above finish floor
Ceiling Fan,16" inches/40.64 cm, Plastic Fan Blade, Motor with
(Note: All ceiling fan control rotary switch were
individually controlled by a 1-single switch installed
7. All electrical works shall be done under the direct supervision of a built-in thermal fuse, 4-speed settings, Power input=60watts, gray
in color and 3D aeromatic brand or its equivalent WITH CONTROL
in two-gang flush type switch) duly licensed Registered Electrical Engineer and or Registered Master F
SWITCH (Note: All ceiling fan control rotary switch were
Electrician. individually controlled by a 1-single switch installed in
two-gang flush type switch)

SHEET Designed & Sealed by a Professional


Name of Project : Prepared by: Submitted by: Recommending Approval : APPROVED: SET NO.:
SHEET
Electrical Engineer (PEE) NO.:
Republic of the Philippines CONTENTS:
DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS Lighting & Power Lay-out
Construction of One (1) Storey, Two(2) Classrooms
E
Legend of electrical
Misamis Oriental First District Engineering Office 32
symbols used School Bldg. with TOILETS MARIVEL FRANCES L. ONG, A.E.R.
OFFICE OF THE DISTRICT ENGINEER General Notes & ERIEL F. SISON HAROLD C. CAERMARE MARCELINO O. CABEGUIN,JR.,A.E.R. 1 of 3 36
Purok 5, Brgy. 26, Gingoog City Specifications PTR #.: PRC Reg. #: Electrical Engineer II Chief of Planning & Design Section OIC Assistant District Engineer District Engineer
Schedule of Loads & Date Issued: Valid Until:
Computation LOCATION: Brgy. Murallon, Gingoog City, Misamis Oriental DATE : DATE : DATE : DATE :
Place Issued: TIN:
POWER RISER DIAGRAM
LIGHTING & CEILING FANS PIPE LAY-OUT
Scale 1:100 MTS.
½” diameter X 3m PVC Pipe installed and lay-outed Overhead Service Entrance connected to 240V,
inside the ceiling with proper support & AC, Single Phase, 2-wires, 60 Hz Power Source
Provide 4 x 4 METAL Box 1600mm 1600mm fittings….Note: Circuit homerun conductor for (#6/2 Aluminum Service Drop Wire to the
installed in ceiling for the lighting outlets should be 2-#3.5 mm2, THHN/ building anchored to single spool secondary

1.70m
lighting outlet 1 1 THWN Stranded Wire & 1-3.5mm2, TW Stranded rack )
1 1 Wire for grounding
2 2 Ceiling

3
LPA 2- # 8.0 mm2,THHN/THWN,
C D C Service Entrance Conductor, 2- # 8.0 mm2,
D Stranded Wire in 3/4”dia. EMT Pipe
a F b F c a F b F c ( #6/2 Aluminum Service Drop Wire THW, Stranded Wire in 3/4” dia. EMT Pipe
shall be anchored to single spool
secondary rack )
Building Wall

a b c a b c 1
F F F F
A B A B LPA

DPA Service Entrance CL-100, Industrial Type Kilowatt-Hour


2ab 2 c 2ab 2 c
M
Meter Base with Metal Enclosure LPA 3500mm
c 2ab
½” diameter X 3m PVC Pipe installed and lay-outed
c b a
inside the ceiling with proper support & 1-5.5mm2, THW Copper wire
1 1 1
fittings….Note: Circuit homerun conductor for in 15mm dia. PVC pipe,
Ground Wire, Color Green
wall fans should be 2-#3.5 mm2, THHN/THWN
Stranded Wire & 1-3.5mm2, TW Stranded Wire for 1800mm
Ceiling Fan,16" inches/40.64 cm, Plastic Fan Blade, Motor grounding
Flush Type Swiches mounted in 2 x 4 with built-in thermal fuse, 4-speed settings, Power Ground floor Line
metal box, deep type (galvanized) & input=60watts, gray in color and 3D aeromatic brand or its
to be installed 1.5 meters above equivalent WITH CONTROL SWITCH (Note: All ceiling Finished Grade Line ELECTRICAL
finished floor line fan control rotary switch were individually controlled
by a 1-single switch installed in two-gang flush type
switch) 16mm dia. x 2400mm length
Grounding Rod Copperweld

POWER PIPE LAY-OUT


Scale 1:100 MTS. ½” diameter X 3m PVC Pipe embedded in Details of Pipe & Boxes : Single Line Diagram
concrete slab flooring of the ground
floor…..Note: Circuit homerun conductor for
convenience outlets should be 2-#3.5 mm2, 2 -8.0 mm2 THW Copper Wire in 3/4-
THHN/THWN Stranded Wire & 1-3.5mm2, TW 2 x 4 Metal Box deep type, Gauge #16
inch diameter EMT Pipe
PANEL BOARD LPA:
(Galvanized)(Embedded in all 1-PHASE, 240-VOLTS, 2-WIRES+GROUND
Stranded Wire for grounding
concrete hollow blocks walling) (2W+G), NEMA-1 METAL
ENCLOSURE,HINGED TYPE, WITH LOCKED
& FLUSH TYPE WALL MOUNTED
½ “inch diameter x 3 meters PVC Pipe
(Orange in color) lay-out inside the ceiling & 1-60 Ampere Frame,32/40 Ampere
concrete slab flooring (Note: Do not use Trip, 2Pole, 10Kaic @ 240Volts MCB
2 flexible PVC pipe) 40Ampere Trip, 2-Pole, 10KAIC OR BOLT-ON or MCB TYPE OF
240v 240v
LPA BOLT-ON or MCB TYPE CIRCUIT BREAKER
240v 240v CIRCUIT BREAKER
4-10/15Ampere Trip, 2Pole, 10 to 20
2.90m

3/4 “ inch diameter x 3 meters EMT Pipe


kaic @ 240 Volts MCB OR BOLT-ON
for Service Entrance
TYPE CB
LIGHTING 1 3 CEILING FAN
DPA Service Entrance OUTLETS 15AT,2P 15AT,2P OUTLETS

CONV. 2 4 S PA R E
4 x 4 METAL Junction Box with cover , Gauge # 16 OUTLETS 15AT,2P 15AT,2P
( For used in wooden ceiling/metal parring ceiling
and concrete slab flooring)

Flush Type Duplex Conv. Outlet, Grounding 1 – #5.5 mm2, TW, Stranded Copper,
type, 16 Amperes, 250 Volt with plate cover
Color Green in ½” diameter PVC Pipe
(3-prongs) mounted to 2x4 Metal Box, Deep
Type (Galvanized), & to be installed 0.30 m clamped to 16mm dia. x 2400mm length
aboved finished floor line Copper weld Grounding Rod

SHEET Designed & Sealed by a Professional


Name of Project : Prepared by: Submitted by: Recommending Approval : APPROVED: SET NO.:
SHEET
Electrical Engineer (PEE) NO.:
Republic of the Philippines CONTENTS:
Pipe lay-out for
DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS Lighting & Power Construction of One (1) Storey, Two(2) Classrooms
Misamis Oriental First District Engineering Office Loads E 32
School Bldg. with TOILETS ERIEL F. SISON HAROLD C. CAERMARE MARCELINO O. CABEGUIN,JR.,A.E.R. MARIVEL FRANCES L. ONG, A.E.R.
OFFICE OF THE DISTRICT ENGINEER Riser Diagram
2 of 3 36
Purok 5, Brgy. 26, Gingoog City Single Line Diagram PTR #.: PRC Reg. #: Electrical Engineer II Chief of Planning & Design Section OIC Assistant District Engineer District Engineer
Details of Pipe & Date Issued: Valid Until:
Boxes Place Issued: TIN:
LOCATION: Brgy. Murallon, Gingoog City, Misamis Oriental DATE : DATE : DATE : DATE :
One Line Diagram
COMPUTATION OF VOLTAGE DROP
Project Title : Construction of One (1) Storey, Two(2) Classrooms School Bldg. with TOILETS

Location : Brgy. Murallon, Gingoog City, Mis. Or.

REMARKS ( 5 % ) Subject : Short Circuit (POINT TO POINT CALCULATION PROCEDURE)


DISTANCE UNITY POWER FACTOR 85% POWER FACTOR
LOAD CONDUCTOR LOAD Allowable VD from Line-to-Line (L-L) Fault
AREA IN TYPE OF NO. OF ONE(1) TRANSFORMER REQUIREMENTS:
COMPUTATION OF VOLTAGE DROP VOLTAGE SIZE USED (CM) CONDUCTOR SETS WAY
CURRENT
Voltage Voltage Voltage Voltage
FEEDER/SE to Available Utility
(V) (AWG) (AMPERES) % VD % VD Farthest PANEL PT = 21.478 A X 230V/1000 = 4.94 KVA Infinite Assumption
(Feet) Drop @ Load Drop Load
BOARD TRANSFORMER RATING: 10.00 KVA
SERVICE ENTRANCE TO Copper,
1 230 #8.0 16,510 1.0 6.56 21.48 0.22 0.10 229.8 0.19 0.1 229.8 Fault X1 Line-to-Line (L-L) Fault
PANELBOARD "LPA" Stranded
POLE MOUNTED TRANSFORMER 10-KVA USING COPPER WINDING
LPA to Farthest Convenience Copper, USE PERCENT IMPEDANCE %Z=1.20%
2 230 #12 6,530 1.0 78.72 6.26 1.95 0.85 228.1 1.66 0.7 228.3
Outlet Stranded TRANSFORMER IMPEDANCE:
TRANSFORMER FULL LOAD AMPERES (F.L.A.)
TOTAL 2.17 0.94 227.83 1.84 0.80 228.2 PASSED Step 1 10KVA,
IFLA = KVA x 1000 / ELL = Transformer Full Load amperes 1-Phase Distribution
Transformer
IFLA = 10000.00 / 230 = 43.48 A
1.20% Z, 230V
DETAILED COMPUTATION OF VOLTAGE DROP: PERCENT of VOLTAGE DROP: Step 2 SYMMETRICAL SHORT
MULTIPLIER (M)= 100 / (PERCENT IMPEDANCE %Z of the Transformer) x (Impedance Tolerance)
X1 CIRCUIT CURRENT=
SINGLE PHASE: 4,025.76 Amps
M = 100 / 1.080 = 92.59 2.0 meters, # 8.0mm2 Cu
Step 3 Magnetic Conduit
VD= (2) x (K) x (I) x (L) / CM %VD= (VD ) / (V) x 100 TRANSFORMER SHORT CIRCUIT CURRENT:
ISC(XFORMER) = Transformer FLA x Multiplier
WHERE: WHERE: ISC(XFORMER) = 43.48 x 92.59 4,025.76 A
VD= Voltage Drop V= Source Voltage VD= Voltage Drop Note: With motor contribution/ If there is, multiply I FLA BY 4 TO 6 40AT,2Pole, Bolt-on or X2
MCB type of Circuit Breaker
ISC(MOTOR CONTRIBUTION) = 0.00 x 43.48 -A
K= Constant value of Copper, 12.90 SYMMETRICAL SHORT
Constant value of Aluminum, 21.20 NOTES: ISC(TOTAL) = 4,025.76 + 0.00 4,025.76 A CIRCUIT CURRENT=
I= Load current in Amperes Fault X2 SERVICE ENTRANCE 3,508.32 Amps
FPN No. 4: Conductors for branch circuits as defined in Article 1.0, sized to prevent Use: 6 to 10 kaic rating
L= Distance from the source to the load in feet a voltage drop exceeding 3 percent at the farthest outlet of power, heating, and
SIZE OF CONDUCTOR:
LPA
AREA IN Circular Mils of Wire use (datas shall be referred 2-#8.0mm2 THW STRANDED COPPER WIRE
lighting loads, or combinations of such loads, and where the maximum total
CM= to Table # 8 of NEC) LENGTH OF CABLE: = 2 meters
voltage drop on both feeders and branch circuits to the farthest outlet does not
exceed 5 percent, provide reasonable efficiency of operation. See FPN No. 2 of L = 2 m x 3.28 = 6.56 feet 0.5 meter, # 3.5mm2 Cu X3
2.15.1.2(a)(3) for voltage drop on feeder conductors OF PEC. Calculation of the " f" factor: Non-Magnetic Conduit
Step 4 SYMMETRICAL SHORT CIRCUIT
CURRENT= 3,245.17
Voltage Drop Diagram: f = 2 x L x ILL / C x n x ELL = Line to Line (L-L) Faults Amps
Use: 6 to 10 kaic rating
f = 52,818.04 / 358,110.00 = 0.14749
2.17 Volts, 0.94% LESS THAN 5% Step 5
M = 1 / 1+f
M = 1 / 1.15 = 0.87
VD SE=0.22 volts, 0.10% PANEL VD=1.95 volts, 0.85% FARTHEST Step 6
BOARD CONV. ISC(PB) = 4,025.76 x 0.87 = 3,508.32 A 15AT,2Pole, Bolt-on or
SERVICE ENTRANCE (LPA) OUTLET MCB,Miniature type of CB
2-#8.0mm2,THHN/THWN IN BRANCH CIRCUIT CONDUCTOR Fault X3 LPA TO CO-OCP Circuit #2
2-#3.5mm2,THHN/THWN 6 to 10 kaic rating
3/4-INCH EMT PIPE SIZE OF CONDUCTOR:
2-#3.5mm2 THHN/THWN STRANDED COPPER WIRE
LENGTH OF CABLE:
DETAILED COMPUTATION BASED ON THE SCHEDULE OF LOADS: *The minimum ampacity and size of branch circuit conductors shall be based on Article
2.10.2.1 page # 39 of the Philippine Electrical Code LT = 0.50 m x 3.28 = 1.64 feet
2.96 meters, # 3.5mm2 Cu X4
Non-Magnetic Conduit
ASSUMED DATAS OF LOADS: Step 7
100 VOLT-AMPERE PER LIGHTING OUTLET
SYMMETRICAL SHORT CIRCUIT
f = 11,507.29 / 141,910.00 = 0.08109 CURRENT= 2,192.62
360 VOLT-AMPERE PER CONVENIENCE OUTLET *AMPERE TRIP RATING OF THE OVER-CURRENT PROTECTION SHALL BE BASED ON:
Step 8 Amps
USING FORMULA OF APPARENT POWER(P) IN VOLT-AMPERE: PEC 2.10.2.2 Overcurrent Protection. Branch-circuit conductors and equipment shall be M = 1 / 1.08 = 0.92
protected by overcurrent protective devices that have a rating or setting that complies Step 9
with 2.10.2.2(a) through (d). DUPLEX
P = (I) x (V) ISC = 3,508.32 x 0.92 = 3,245.17 A CONVENIENCE
WHERE: Fault X4 CO-OCP TO Nearest Convenience Outlet OUTLET
Apparent Power in Volt-Ampere
P= *KAIC RATING OF CIRCUIT BREAKERS SHALL BE BASED ON THE RESULT OF THE
SIZE OF CONDUCTOR:
AC Source voltage in Volts
V= SHORT CIRCUIT ANALYSIS/COMPUTATION AS REQUIRED PER 1.3.2f, Page #16 of PEC
2-#3.5mm2 THHN/THWN STRANDED COPPER WIRE
Load Current in Amperes
I=
COMPUTATION OF INDIVIDUAL BRANCH CIRCUIT LOAD CURRENT IN LENGTH OF CABLE:
COMPUTATION OF TOTAL LOAD CURRENT WITH DEMAND FACTOR:
AMPERES:

I = (P) / (V) = _____ Amperes I T= (PT) / (V) = (PT) volt-ampere / 230volts(Demand Factor)= 21.48A
LT = 2.96 m x 3.28 = 9.71 feet NOTE: THE ELECTRICAL DESIGN ANALYSIS PER PHILIPPINE
Step10
CORRECT SIZING OF INDIVIDUAL BRANCH CIRCUIT CONDUCTOR SHALL BE
Refer to Table #3.10.1.16 & 2.10.2.2 the size of service entrance and main over-
current protection shall be as follows:
f = 68,123.14 / 141,910.00 = 0.48 ELECTRICAL CODE REQUIREMENT ON ARTICLE 1.3.2.1f Page
BASED ON Table # 3.10.1.16 Allowable Ampacities of Insulated Conductors Rated 0 Step 11
Through 2000 Volts, 60°C Through 90°C (140°F Through 194°F), Not More Than
Three Current-Carrying Conductors in Raceway, Cable, or Earth (Directly Buried),
SERVICE ENTRANCE: 2-#8.0mm2, THHN/THWNStranded Wire and 1-#5.5mm2,
TW Stranded wire(GROUND) in 3/4" dia. EMT Pipe
Step 12
M = 1 / 1.48 = 0.68 # 15 shall be included on the drawings or shall be submitted on
Based on Ambient Temperature of 30°C (86°F) , PAGE # 177 OF THE PHILIPPINE MAIN PROTECTION: 60AF, 40AT, 2-Pole, 10KAIC @ 240 Volts,Bolt-on or MCB
ELECTRICAL CODE PER RESULT OF THE INDIVIDUAL CURRENT FORMULA AS
STATED.
type of Circuit Breaker ISC = 3,245.17 x 0.68 = 2,192.62 A separate sheets of standard size.
SHEET Designed & Sealed by a Professional
Name of Project : Prepared by: Submitted by: Recommending Approval : APPROVED: SET NO.:
SHEET
Electrical Engineer (PEE) NO.:
Republic of the Philippines CONTENTS:
DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS DESIGN ANALYSIS Construction of One (1) Storey, Two(2) Classrooms
Misamis Oriental First District Engineering Office -SHORT CIRCUIT &
School Bldg. with TOILETS E 32
ERIEL F. SISON HAROLD C. CAERMARE MARCELINO O. CABEGUIN,JR.,A.E.R. MARIVEL FRANCES L. ONG, A.E.R.
OFFICE OF THE DISTRICT ENGINEER VOLTAGE DROP
3 of 3 36
Purok 5, Brgy. 26, Gingoog City CALCULATION PTR #.: PRC Reg. #: Electrical Engineer II Chief of Planning & Design Section OIC Assistant District Engineer District Engineer
Date Issued: Valid Until:
LOCATION: Brgy. Murallon, Gingoog City, Misamis Oriental DATE : DATE : DATE : DATE :
Place Issued: TIN: