8 How to install the desktop kit for NKG901

Install it according to the instructions included in the NKG901 desktop kit MPBX52280. The main
points of the work are as follows.
a) For new installation, use unprocessed wire for the power cable. The installer should prepare the wire .
b) When replacing 5HPCC00013, isolate the power, remove the plug of the DPU-414 power cable
(7ZCJD0257C), trim the ends of the power cable back, and connect them to the terminal block of
NKG901
printer Paying particular attention to the polarity of the connections
c) When replacing 5HPCC00013, the data cable can be used as it is.
d) The Installation screws must be prepared by the installer according to the mounting method.

9 NKG901 Desktop Kit Shipment Start Time


Scheduled for August 2021.

10 Attachment
a) Outline drawing
b) Assembly instructions

Appendix: Main specifications of NKG901 desktop kit with NKG901 and comparison with 5HPCC00013
Model name DPU-414 NKG901 Desktop Kit with NKG901
Power supply 6.5~7.0V 5.0~9.0V
Current
2.0A 2.0A
consumption
Baud rate 4800bps 4800bps
112mm
Paper width 58mm
(part number: 6ZCAF00252A)
Connect with unprocessed wire
Power cable Dedicated cable(7ZCJD0257C)
For replacement, process 7ZCJD0257C
Communication
cable
D-sub cable(7ZCJD0254A or 7ZCJD0270B) D-sub cable(7ZCJD0254A or 7ZCJD0270B)

Interface Serial communication Serial communication


NKG-901 priinter

Appearance
Velcro or screw

Dimensions Width 170mm x Height 66.5mm x Depth 160mm Width 220 mm x Height 155 mm x Depth 123 mm
Installation Velcro or screw
Velcro
method (Screws are prepared by the installer)