You are on page 1of 1

I bought a machine that originally had a toolchanger on it. I am now having two issues.

First, when I call an m6 t... D... command it goes to the locationwhere it changed tools for the ATC. I would
like it to just raise up in z axis to a set Z height location. Where are those parameters located to make the
necessar changes?

Second issue might be related to the problem above. The push button for the power drawbar on the front of
the machine isn't active. Where are the parameters for that located.

I appreciate any help you can provide. Thanks

Suggestion
To thank

Quote
Answer

8/4/2014 11:19 AM
Rate (0)
pierre_g Hello,

Do you check these parameters :

MD10715 $MN_M_NO_FCT_CYCLE[X]=6
MD10716 $MN_M_NO_FCT_CYCLE_NAME[X]=

This define the SPF call with M6 store in CMA_DIR.

Pierre