You are on page 1of 15

EDULABS DIDACTIC

UNIVERSAL LAB STATION


ULS-2000

INSTRUCTION MANUAL
ULS-2000 Instruction Manual

Table Of Contents

SECTION TITLE PAGE


1 Introduction 2
2 Features 2
3 Preparation for Use 2
3-1 Unpacking and Contents Check 2
3-2 Pre-Operation Procedure 2
3-3 First Operation 3
4 Controls and Indicators 4
5 Specifications, Operation, Pre-Operation, Applications 6
5-1 Power Switch 6
5-2 DC Power Supplies 6
5-3 Function Generator 8
5-5 5 Bits Data Switches 9
5-11 AC Power Supplies 10
5-13 Multi Interface Adaptors 10
6 Maintenance 11
6-1 Fuse Replacement 11
6-2 Cleaning 11
7 Technical Documentation 12
7-1 Circuit Diagrams 12
8 Warranty and Standard Conditions of Sale 15

EDULABS DIDACTIC 1 www.scienscope.com.my


ULS-2000 Instruction Manual
SECTION 1: INTRODUCTION

The ULS-2000 UNIVERSAL LAB STATION is an ideal teaching aid for all types of electronic circuits. There are
variety of functional input and output circuits (see Features) which can be used to stimulate or measure electrical signals
from the circuit under test or development. These circuit functions allow for the testing of circuits without the need for
many expensive individual pieces of equipment.

SECTION 2: FEATURES

 Completely Self-Contained Unit


 AC Power Supplies: 19V – 15V – 9V – 0V – 9V – 15V – 19V
 DC Power Supplies: Fixed : +5V/0.5A, -5V/0.5A, +12V/0.5A, -12V/0.5A, Variable : +/-0V to +/-25V, 0.5A
 1 Channels Function Generator with frequency adjust, amplitude and DC offset control Sine, Triangle and
Square Wave Outputs with selection frequency from 10 Hz to 1MHz in 6 decades.
 1 Channels TTL Model with frequency adjust with clock output 1 Hz to 1MHz in 6 decades.
 5 HI/LO Data Output Switches (+5, 0V)
 5 Numbers 4mm, 2mm Sockets to Turn Pin Header Adaptors

SECTION 3: PREPARATION FOR USE

3-1 : Unpacking and Contents Check


The ULS-2000 comes complete and ready to use. Check the following components list when unpacking. If
any pieces are missing, immediately notify the distributor you purchased the instrument from.

 ULS-2000 Universal Lab Station


 AC Power Cable
 Instructions Manual

3-2 : Pre-Operation Procedure

Inspect the ULS-2000 for any signs of damage. Make sure that the power cord is for your voltage 240 VAC.
Allowable input voltages are as follows:

240VAC : 240 VAC @ 50Hz, ±10%

CAUTION
Should the ULS-2000 UNIVERSAL LAB STATION fail to operate after applying AC power check the fuse
located on the back panel. Replace with the same type and style fuse of 3A, 240V or equal specifications.

EDULABS DIDACTIC 2 www.scienscope.com.my


ULS-2000 Instruction Manual

WARNING
READ AND UNDERSTAND THIS MANUAL BEFORE
USING THE INSTRUMENT.
Failure to understand and comply with the WARNINGS
and operating instructions can result in serious or fatal
injuries and/or property damage

3-3 : First Operation

It is recommended that during the first operation of the ULS-2000 the Pre-Operation checks are performed as per
section 3. These checks will help to verify the proper operation of the ULS-2000 UNIVERSAL LAB STATION. These
checks can also be made at any time in the future as a partial performance test.

SECTION 4: CONTROLS AND INDICATORS


2 1 10

7 8 9

EDULABS DIDACTIC 3 www.scienscope.com.my


ULS-2000 Instruction Manual

Index
Control or Indicator Function
No.

1 Power Switch Provide the On/Off switching of incoming power.

2 AC Power Supplies Provides two 19VAC, two 15VAC and outputs

Supplies Six DC power supplies as follows


+5V & -5V @ 0.5A max
3 DC Power Supply +12V & -12V @ 0.5A max
+V (+0V ~ +23Vdc) @ 0.5A max
-V (-0V ~ -23Vdc) @ 0.5A max

Selects the range of the frequency in times 10 increments for


Function Generator & Clock Generator. Switch Position Range
x 10 1 Hz - l0 Hz
x 100 10 Hz - 100 Hz
4 Frequency Range Switch
x 1K l00 Hz - 1 KHz
x 10K 1 KHz - l0 KHz
x l00K 10 KHz - l00 KHz
x 1M 100 KHz – 500KHz

5 Waveform Selection Select Waveform for Square, Triangle and Sine wave

Adjusts the variable frequency of the function generator & Clock


6 Frequency Control
based upon the Frequency Range Switch setting

Provide frequency adjustable output Square waveform, Frequency


7 DC offset Control
range from 1Hz to 500kHz in 6 decades with fine Adjust

8 Amplitude Control Adjusts the amplitude of the Function Generator Waveform

9 4mm Adaptor Provides 5 numbers 4mm socket to turn pin headers

10 Data Switches Provides 16 sets of data switching of "+5V" and "0V" outputs

EDULABS DIDACTIC 4 www.scienscope.com.my


ULS-2000 Instruction Manual
SECTION 5: SPECIFICATIONS, OPERATION, PRE-OPERATION AND APPLICATIONS

The following section covers the above four topics grouped for each function. The pre-operation procedures,
when provided are to verify that functional circuits are operating and to help gain familiarity with the equipment features.
Refer to section 4 for all ULS-2000 controls, indicators and functions when performing the pre-operation checks.

5-1 : Power Switch

Figure 1

The main power switch controls the power source for the whole trainer. The trainer will only get the power source
when the power switch has been turned on, and the light on the switch is on.

5-2: DC Power Supplies

Figure 2

5-2.1 : Variable Supplies

Specifications:
Output Voltage: +0V to +25V, -0V to -25V
Output Current: 0.5A max

Operation:
The two independent variable power supply outputs are connected between the "+V and GND" and also
the "-V and GND". Each output is controlled individually by the "+V" and "-V" controls.

EDULABS DIDACTIC 5 www.scienscope.com.my


ULS-2000 Instruction Manual
Application:
The variable power supply outputs can be used to power different linear devices such as operational
amplifiers and TTL, CMOS, and compatible logic devices.

5-2.2 : +5 Vdc Supply

Specifications:
Output Voltage: +5 ± 0.25 Vdc
Output Current: 0.5A max

5-2.3 : -5Vdc Supply

Specifications:
Output Voltage: -5 ± 0.25 Vdc
Output Current: 0.5A max

Application:
The +5 and -5 power supplies can be used as the source power of logic circuits such as TTL or CMOS.

5-2.4 : +12 Vdc Supply

Specifications:
Output Voltage: +12 ± 0.25 Vdc
Output Current: 0.5A max

5-2.5 : -12Vdc Supply

Specifications:
Output Voltage: -12 ± 0.25 Vdc
Output Current: 0.5A max

Application:
The +12 and -12 power supplies can be used as the source power of logic circuits such as TTL or CMOS.

EDULABS DIDACTIC 6 www.scienscope.com.my


ULS-2000 Instruction Manual
5-3 : Function Generator

Figure 3
Specifications:
Frequency Ranges: 1 Hz to 10 Hz
10 Hz to 100 Hz
100 Hz to 1 kHz
1 kHz to 10 kHz
10 kHz to 100 kHz
100 kHz to 500 kHz

The output frequency is continuously variable between these ranges by adjusting the variable frequency control
knob.
The amplitude is variable for the sine wave, triangle and square wave by adjusting the amplitude control knob.

Sine Wave : 0 to 20Vp-p


20Vp-p
Variable

Triangle wave : 0 to 9Vp-p


9Vp-p
Variable

Square wave : 0 to 24Vp-p


22Vp-p
Variable

Figure 4

EDULABS DIDACTIC 7 www.scienscope.com.my


ULS-2000 Instruction Manual
Operation:
The output of each function is made at the terminals as shown in Fig 4. All outputs are available simultaneously at
the same frequency. Select the frequency range and then fine tune the frequency using the Variable Frequency
Control Knob. Adjust the amplitude of the sine, triangle and Square wave using the Amplitude control.

Pre-Operation Check:
The output of the function generator can be observed by using an oscilloscope. Connect the outputs to the
oscilloscope being certain to connect GND to GND between the Oscilloscope and ULS-2000. The GND on the
ULS-2000 is common with the AC Power ground connection. Most oscilloscopes also have their input ground pin
common with the AC power ground of the oscilloscope. Please make sure that the grounds are connected properly.

Application:
The function generator can be used to generate input stimuli waveforms for all types of digital and analog circuits.
It should be noted however that for triggering TTL and compatible gates the negative portion of the square wave
should be removed. This can be accomplished by using a comparator or clipping circuit.

5-4: Data Switch (16 Channels)

Figure 5

Specifications:
Outputs: 0 or +5V (TTL) / +12V (CMOS) Break before make switches

Pre-Operation Check:
1. Connect the "0" Data switch to the DMM input.
2. Connect the GND to the DMM input.
3. Turn the selector switch to TTL output (+5V)
4. Set the "0" Data Switch to the "0" position and verify that the DMM reads approximately 0 volts.
5. Set the "0" Data Switch to the "1” position and verify that the DMM reads approximately +5 volts.
6. Repeat steps 1 - 4 for "1 “through "15" Data Switches.
7. Turn the selector switch to CMOS output (+12V)
8. Set the "0" Data Switch to the "0" position and verify that the DMM reads approximately 0 volts.
9. Set the "0" Data Switch to the "1” position and verify that the DMM reads approximately +12
volts.
10. Repeat steps 1 - 4 for "1 “through "15" Data Switches.

Applications:
The Data Switches "0" - "15" provide a logic high (+5V) / CMOS (+12V) or low (0 V) output which are
short circuit current limit protected. These switches are placed in an open circuit state condition when the
switch is activated. These switches can be used independently to provide a 1 or 0 logic state, or they can
be used together to represent an 8 bit byte, BCD or other coded input. And it’s also can be use to provide
CMOS outputs.

EDULABS DIDACTIC 8 www.scienscope.com.my


ULS-2000 Instruction Manual
5-5: AC Power Supplies

Figure 16

Specification:
1. Consist of two 19VAC, two 15VAC outputs.
Operation:
Connect one of the outputs to one of the 19V/15V point and another output to one of the point 0.

5-13 : 4mm Adaptor Interface

Figure 18

The 4mm adaptor consists of five sockets (4mm size) where the outputs for each sockets connected directly to
2mm brass pin to 4 numbers of turn pin.

EDULABS DIDACTIC 9 www.scienscope.com.my


ULS-2000 Instruction Manual
SECTION 6: MAINTANANCE
WARNING
Remove power prior for performing maintenance on equipment. Failure to do so can cause serious
injury to personnel.

Maintenance consists of fuse replacement, calibration adjustment procedures, and periodic cleaning. Performing the
calibration and adjustment procedures only by Authorized Service Engineer, otherwise the warranty will void.

CAUTION
The following procedures should only be performed by persons trained and qualified in electronics and
electronic equipment service. Do not attempt these procedures if not qualified.

6-1 : Fuse Replacement

1) Ensure AC power is disconnected from equipment.

2) Turn to back of ULS-2000 and locate the fuse package.

3) Open the fuse cover and remove the dysfunction fuse.

4) Replace with the same type and style fuse of 3A, 250V or equal specifications.

6-2 : Cleaning

The ULS-2000 can be cleaned with a dry, soft cloth to remove any oil, grease, or grime from the equipment.
Never use liquid solvents or detergents. If the equipment got wet for any reason, dry using low pressure air (less
than 25 PSI). Use care and caution around areas where water or air could enter the interior of the equipment while
drying.

EDULABS DIDACTIC 10 www.scienscope.com.my


ULS-2000 Instruction Manual
SECTION 7: TECHNICAL DOCUMENTATION

7-1: Circuit Diagrams

7-1-1: Power Supplies (+5VDC & -5VDC)

7-1-2 : Power Supplies (+12VDC & -12VDC)

EDULABS DIDACTIC 11 www.scienscope.com.my


ULS-2000 Instruction Manual
7-1-3: Power Supplies (0 ~ +24VDC & 0 ~ -24VDC)

EDULABS DIDACTIC 12 www.scienscope.com.my


ULS-2000 Instruction Manual
7-1-4: Function Generator

EDULABS DIDACTIC 13 www.scienscope.com.my


ULS-2000 Instruction Manual
SECTION 8: WARRANTY AND STANDARD CONDITIONS OF SALE

The Seller warrants to the Purchaser that any equipment manufactured by it and bearing its name plate to be free from
defects in material or workmanship, under proper and normal use and service, as follows: If, at any time within one (1)
year from the date of shipment, the Purchaser notifies the Seller that in his opinion, the equipment is defective, and returns
the equipment to the Seller’s originating factory prepaid, and the Sellers inspection finds the equipment to be defective in
material or workmanship except part like switches, knob, push button, lighting, etc. the Seller will promptly correct it
by either, at its option, repairing any defective part or material or replacing it free of charge and return shipping lowest
cost transportation prepaid by purchaser (if Purchaser requests premium transportation, Purchaser will be billed for
difference in transportation costs). If inspection by the Seller does not disclose any defect in material or workmanship, the
Seller’s regular charges will apply. This warranty shall be effective only if use and maintenance is in accordance with
Seller's instructions and written notice of a defect is given to the Seller within such period. THIS WARRANTY IS
EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES, WRITTEN, ORAL OR IMPLIED.
SPECIFICALLY, WITHOUT LIMITATION, THERE IS NO WARRANTY OF MERCHANTABILITY OR
FITNESS FOR ANY PURPOSE. The liability of the Seller shall be limited to the repair or replacement of materials or
parts as above set forth.

LIMITATION OF LIABILITY

The Seller shall not be liable for any claim or consequential or special loss or damage arising or alleged to have arisen
from any delay in delivery or malfunction or failure of the equipment. The Seller’s liability for any other loss or damage
arising out of or connected with the manufacture or use of the equipment sold, including damage due to negligence, shall
not in any event exceed the price of the equipment supplied by Seller.

GENERAL CONDITIONS

All orders are subject to acceptance by Seller at its Main Office. Stenographic and clerical errors are subject to correction.
No oral or subsequent modification or any other foregoing general provisions or of any term or condition of any order
shall be binding unless agreed to in writing by the Seller and Purchaser.

SCIENSCOPE SDN BHD reserves the right to make changes at any time, without notice, in prices, colors, materials,
specifications and models, and also to discontinue models.

SCIENSCOPE SDN BHD


(Company No: 520887-D)
20, Jalan BP 5/10, Bandar Bukit Puchong,
47100 Puchong, Selangor Darul Ehsan.
Tel: 6012-4080443
E-mail: sales@scienscope.com.my
Website: http://www.scienscope.com.my

Solution provider for scientific and technical education training system since 2000

EDULABS DIDACTIC 14 www.scienscope.com.my