You are on page 1of 3

DESIGNED BY : PMG TATA CONSULTING ENGINEERS LIMITED JOB NO.

XXXX

DATE : 3/4/2024 CLIENT : XXX DOC. NO. XXXX

CHECKED BY : XXX PROJECT : XXX SUBJECT : SLAB DESIGN

DATE : 3/4/2024 BU: IBU DC: PUN DISC: CV SHEET: 1 OF 2 REV. NO. 0

One Way Slab Design : -


ly = 4.50 m

1.50 m
One way slab

=
lx
Input Data :-
Grade of concrete (fck) = 25 N/mm2
Grade of steel (main and distributin) (fy) = 415 N/mm2
Diameter of main steel = 10 mm
Diameter of distribution steel = 8 mm
Clear cover to slab reinforcement = 20 mm
Thickness of the slab (D) = 150 mm
Assuming width of the slab = 1000 mm
Thickness of the floor finish = 50 mm
Effective depth for distribution = 116 mm
Effective depth for main steel = 125 mm
Clear longer span dimension of slab panel = 4.5 m
Clear shorter span dimension of slab panel = 1.5 m
Density of concrete = 25 kN/m3
Density of floor finish = 24 kN/m3
Characteristic compressive strength of concrete (fck) = 25 N/mm2
Characteristic yield strength of steel (fy) = 415 N/mm2
Supporting beam width of longer span slab panel = 300 mm
Supporting beam width of shorter span slab panel = 300 mm
Effective length of longer span of slab panel (ly) = 4.65 m
Effective length of shorter span of slab panel (lx) = 1.65 m
Ratio of longer to shorter span of slab (ly / lx) = 2.82
The slab is to be design as = One way slab

Load Calculations : -
Dead load of slab = 3.75 kN/m2
Partition wall load (if any) = 0.00 kN/m2
Floor finish load = 1.2 kN/m2
Live load = 3.00 kN/m2 IS 875 (Part-2):1987
4.95 kN/m Table No.1 and 2
2
Total dead load =
3.00 kN/m
2
Total live laod =
Load factor = 1.50
Factored total dead load (WDL) = 7.43 kN/m2
Factored total live laod (WLL) = 4.50 kN/m2
11.93 kN/m
2
Total factored laod =

Bending Moment and Shear Force Calculations :-


Span of the slab (L) = = 1.50
(WDL x L2) (WLL x L2) IS 456:2000 / Page No.36
Maximum bending moment = + = 2.80 kN.m
10 9 Table No.12 and 13
Maximum shear force = (WDL) x 0.6 + (WLL) x 0.6 = 7.15 kN

Main Steel Calculations :-


Area of main steel required (Ast)main = 62.49 mm2
Provided main steel diameter = 10.0 mm
DESIGNED BY : PMG TATA CONSULTING ENGINEERS LIMITED JOB NO. XXXX

DATE : 3/4/2024 CLIENT : XXX DOC. NO. XXXX

CHECKED BY : XXX PROJECT : XXX SUBJECT : SLAB DESIGN

DATE : 3/4/2024 BU: IBU DC: PUN DISC: CV SHEET: 1 OF 2 REV. NO. 0

Required spacing of main steel = 1256.8 mm


Provided spacing of main steel = 200.0 mm
Provide 10mm diameter steel at 200mm c/c as main reinforcement.
392.7 mm
2
Area of main steel provided (Ast)main =
Provided percentage of main steel (Pt)main = 0.31 %

Distribution Steel Calculations :-


180.0 mm
2
Distribution reinforcement = 0.12 % of cross sectional area =
180.0 mm
2
Distribution reinforcement (Ast)distri =
Provided distribution steel diameter = 8.0 mm
Required spacing of distribution steel = 279.3 mm
Provided spacing of distribution steel = 200.0 mm
Provide 8mm diameter steel at 200mm c/c as distribution reinforcement.

251.3 mm
2
Area of distribution steel provided (Ast)distri =
Provided percentage of distribution steel (Pt)distri = 0.22 %

Shear Force Calculation :-


Maximum shear force = 9.84 kN
Provided maximum percentage of steel = 0.31 %
Design shear strength of concrete (tc) = 0.39 N/mm2
Thickness of the slab = 150 mm
The value of k = 1.30
Design shear strength of concrete (t'c) = (tc x k) = 0.51 N/mm2
Nominal shear strength of concrete (tv) = 0.06 N/mm2
Design shear strength of con. is greater than nominal shear strength of con.

Hence safe in shear

Deflection Calculation :-
Actual ratio for span to eff. depth = 37.2 Clause No.23.2.1 a) / Page No.37
Area of steel required (Ast)req = 180.0 mm2
Area of steel provided (Ast)prov = 392.7 mm2
Stress in steel (fs) = (0.58 x fy x ((Ast)req / (Ast)prov))) = 110.4 N/mm2 IS 456:2000
Read the value of modification factor w.r.t the provided % of reinf. and fs. Page No.38 and 39
Modification factor (Tension reinf.) = 1.90 IS 456:2000 / Figure No.4
Modification factor (Compression reinf.) = 1.08 IS 456:2000 / Figure No.5
Modification factor (Flanged sections) = 0.95 IS 456:2000 / Figure No.6
Type of slab = Simply supported IS 456:2000 / Clause No.23.2.1
Basic ratio for span to eff. depth = 20.0 IS 456:2000 / Clause No.23.2.1
Max. ratio for span to eff.depth = (Basic ratio for span to eff. depth x Modification factor)
Max. ratio for span to eff. depth = 39.0
Max. ratio for span to eff. depth > Actual ratio for span to eff. depth

Hence safe in deflection


Table No. 26 of IS 456 : 2000
1.00 1.10 1.20 1.30 1.40 1.50 1.75 2.00
Interior Panels:
Negative moment at continuous edge 0.032 0.037 0.043 0.047 0.051 0.053 0.060 0.065
Positive moment at mid-span 0.024 0.028 0.032 0.036 0.039 0.041 0.045 0.049
One Short Edge Continuous:
Negative moment at continuous edge 0.037 0.043 0.048 0.051 0.055 0.057 0.064 0.068
Positive moment at mid-span 0.028 0.032 0.036 0.039 0.041 0.044 0.048 0.052
One Long Edge Discontinuous:
Negative moment at continuous edge 0.037 0.044 0.052 0.057 0.063 0.067 0.077 0.085
Positive moment at mid-span 0.028 0.033 0.039 0.044 0.047 0.051 0.059 0.065
Two Adjacent Edges Discontinuous:
Negative moment at continuous edge 0.047 0.053 0.060 0.065 0.071 0.075 0.084 0.091
Positive moment at mid-span 0.035 0.040 0.045 0.049 0.053 0.056 0.063 0.069
Two Short Edges Discontinuous:
Negative moment at continuous edge 0.045 0.049 0.052 0.056 0.059 0.060 0.065 0.069
Positive moment at mid-span 0.035 0.037 0.040 0.043 0.044 0.045 0.049 0.052
Two Long Edges Discontinuous:
Negative moment at continuous edge 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Positive moment at mid-span 0.035 0.043 0.051 0.057 0.063 0.068 0.080 0.088
Three Edges Discontinuous (One Long Edge Discontinuous)
Negative moment at continuous edge 0.057 0.064 0.071 0.076 0.080 0.084 0.091 0.097
Positive moment at mid-span 0.043 0.048 0.053 0.057 0.060 0.064 0.069 0.073
Three Edges Discontinuous (One Long Edge Discontinuous)
Negative moment at continuous edge 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Positive moment at mid-span 0.043 0.051 0.059 0.065 0.071 0.076 0.087 0.096
Four Edges Discontinuous:
Positive moment at mid-span 0.056 0.064 0.072 0.079 0.085 0.089 0.100 0.107

Negative
Positive
moment at
moment at
continuous
mid-span
edge
Interior Panels (Continuous All Four Sides): 0.032 0.024
One Short Edge Discontinuous: 0.037 0.028
One Long Edge Discontinuous: 0.037 0.028
Two Adjacent Edges Discontinuous: 0.047 0.035
Two Short Edges Discontinuous: 0.000 0.035
Two Long Edges Discontinuous: 0.045 0.035
Three Edges Discontinuous (One Long Edge Continuous) 0.000 0.043
Three Edges Discontinuous (One Short Edge Continuous) 0.057 0.043
Four Edges Discontinuous: 0.000 0.056