DATE : 3/4/2024 BU: IBU DC: PUN DISC: CV SHEET: 1 OF 2 REV. NO. 0
1.50 m
One way slab
=
lx
Input Data :-
Grade of concrete (fck) = 25 N/mm2
Grade of steel (main and distributin) (fy) = 415 N/mm2
Diameter of main steel = 10 mm
Diameter of distribution steel = 8 mm
Clear cover to slab reinforcement = 20 mm
Thickness of the slab (D) = 150 mm
Assuming width of the slab = 1000 mm
Thickness of the floor finish = 50 mm
Effective depth for distribution = 116 mm
Effective depth for main steel = 125 mm
Clear longer span dimension of slab panel = 4.5 m
Clear shorter span dimension of slab panel = 1.5 m
Density of concrete = 25 kN/m3
Density of floor finish = 24 kN/m3
Characteristic compressive strength of concrete (fck) = 25 N/mm2
Characteristic yield strength of steel (fy) = 415 N/mm2
Supporting beam width of longer span slab panel = 300 mm
Supporting beam width of shorter span slab panel = 300 mm
Effective length of longer span of slab panel (ly) = 4.65 m
Effective length of shorter span of slab panel (lx) = 1.65 m
Ratio of longer to shorter span of slab (ly / lx) = 2.82
The slab is to be design as = One way slab
Load Calculations : -
Dead load of slab = 3.75 kN/m2
Partition wall load (if any) = 0.00 kN/m2
Floor finish load = 1.2 kN/m2
Live load = 3.00 kN/m2 IS 875 (Part-2):1987
4.95 kN/m Table No.1 and 2
2
Total dead load =
3.00 kN/m
2
Total live laod =
Load factor = 1.50
Factored total dead load (WDL) = 7.43 kN/m2
Factored total live laod (WLL) = 4.50 kN/m2
11.93 kN/m
2
Total factored laod =
DATE : 3/4/2024 BU: IBU DC: PUN DISC: CV SHEET: 1 OF 2 REV. NO. 0
251.3 mm
2
Area of distribution steel provided (Ast)distri =
Provided percentage of distribution steel (Pt)distri = 0.22 %
Deflection Calculation :-
Actual ratio for span to eff. depth = 37.2 Clause No.23.2.1 a) / Page No.37
Area of steel required (Ast)req = 180.0 mm2
Area of steel provided (Ast)prov = 392.7 mm2
Stress in steel (fs) = (0.58 x fy x ((Ast)req / (Ast)prov))) = 110.4 N/mm2 IS 456:2000
Read the value of modification factor w.r.t the provided % of reinf. and fs. Page No.38 and 39
Modification factor (Tension reinf.) = 1.90 IS 456:2000 / Figure No.4
Modification factor (Compression reinf.) = 1.08 IS 456:2000 / Figure No.5
Modification factor (Flanged sections) = 0.95 IS 456:2000 / Figure No.6
Type of slab = Simply supported IS 456:2000 / Clause No.23.2.1
Basic ratio for span to eff. depth = 20.0 IS 456:2000 / Clause No.23.2.1
Max. ratio for span to eff.depth = (Basic ratio for span to eff. depth x Modification factor)
Max. ratio for span to eff. depth = 39.0
Max. ratio for span to eff. depth > Actual ratio for span to eff. depth
Negative
Positive
moment at
moment at
continuous
mid-span
edge
Interior Panels (Continuous All Four Sides): 0.032 0.024
One Short Edge Discontinuous: 0.037 0.028
One Long Edge Discontinuous: 0.037 0.028
Two Adjacent Edges Discontinuous: 0.047 0.035
Two Short Edges Discontinuous: 0.000 0.035
Two Long Edges Discontinuous: 0.045 0.035
Three Edges Discontinuous (One Long Edge Continuous) 0.000 0.043
Three Edges Discontinuous (One Short Edge Continuous) 0.057 0.043
Four Edges Discontinuous: 0.000 0.056