Professional Documents
Culture Documents
495 2801 Datasheetz
495 2801 Datasheetz
EPCOS AG 2007. Reproduction, publication and dissemination of this data sheet, enclosures hereto and the
information contained therein without EPCOS’ prior express consent is prohibited.
2−line filters B84112G0000*
SIFI−G for enhanced insertion loss
Construction
S 2−line filter
S Metal case
S Polyurethane potting (UL 94 V−0)
Features
S Easy to install
S Compact design
S Cost optimized construction
S Medical version with low leakage current
S ENEC10, UL and cUL approval
c us
Applications
S Switched−mode power supplies for
− industrial electronics
− telecom systems
− data systems
S DC applications
S Medical engineering Type M
Terminals
S Case style B: tab connectors 6.3 x 0.8 mm for filters up to 16A
mounting tabs on face ends
S Case style G: threaded studs M5 for filters from 20A to 36A
Marking
S Marking on component:
manufacturer’s logo, ordering code, rated voltage, rated current,
rated temperature, climatic category, date code
S Minimum marking on packaging: maufacturer’s logo, ordering code,
date code, quantity
L L’
PE
N N’
L L’
PE
N N’
A mH mA g
3 2 x 0,22 µF (X2) 2 x 10 < 0,5 1 200 B84112G0000B030
X X X
2 x 4700 pF (Y2)
6 2 x 0,47 µF (X2) 2 x 3,3 < 0,5 1 200 B84112G0000B060
X X X
2 x 4700 pF (Y2)
10 2 x 0,68 µF (X2) 2 x 1,8 < 0,5 1 200 B84112G0000B110
X X X
2 x 4700 pF (Y2)
16 2 x 0,47 µF (X2) 2 x 1,8 < 0,5 1 210 B84112G0000B116
X X X
2 x 4700 pF (Y2)
20 2 x 1,0 µF (X2) 2 x 1,8 < 0,5 2 440 B84112G0000G120
X X X
2 x 4700 pF (Y2)
25 2 x 1,0 µF (X2) 2 x 1,6 < 0,5 2 440 B84112G0000G125
X X X
2 x 4700 pF (Y2)
36 2 x 1,5 µF (X2) 2 x 0,8 < 0,5 2 470 B84112G0000G136
X X X
2 x 4700 pF (Y2)
A mH µA g
3 2 x 0,22 µF (X2) 2 x 10 <2 1 200 B84112G0000M030 X X X
6 2 x 0,47 µF (X2) 2 x 3,3 <2 1 200 B84112G0000M060 X X X
10 2 x 0,68 µF (X2) 2 x 1,8 <2 1 200 B84112G0000M110 X X X
16 2 x 0,47 µF (X2) 2 x 1,8 <2 1 210 B84112G0000M116 X X X
20 2 x 1,0 µF (X2) 2 x 1,8 <2 2 440 B84112G0000M120 X X X
25 2 x 1,0 µF (X2) 2 x 1,6 <2 2 440 B84112G0000M125 X X X
36 2 x 1,5 µF (X2) 2 x 0,8 <2 2 470 B84112G0000M136 X X X
X = approval granted
2) maximum voltage = UR; frequency = 50 Hz without harmonics; tolerance of capacitors −20%/ 0%; worst case positioning of the compo-
nents
B84112G0000B030 B84112G0000B060
100 100
dB dB
a a
80 80
60 60
40 40
20 20
0 0
104 105 106 107 Hz 108 104 105 106 107 Hz 108
f f
B84112G0000B110 B84112G0000B116
100 100
dB dB
a a
80 80
60 60
40 40
20 20
0 0
104 105 106 107 Hz 108 104 105 106 107 Hz 108
f f
B84112G0000G120 B84112G0000G125
100 100
dB dB
a a
80 80
60 60
40 40
20 20
0 0
104 105 106 107 Hz 108 104 105 106 107 Hz 108
f f
B84112G0000G136
100
dB
a
80
60
40
20
0
104 105 106 107 Hz 108
f
B84112G0000M030 B84112G0000M060
100 100
dB dB
a a
80 80
60 60
40 40
20 20
0 0
104 105 106 107 Hz 108 104 105 106 107 Hz 108
f f
B84112G0000M110 B84112G0000M116
100 100
dB dB
a a
80 80
60 60
40 40
20 20
0 0
104 105 106 107 Hz 108 104 105 106 107 Hz 108
f f
B84112G0000M120 B84112G0000M125
100 100
dB dB
a a
80 80
60 60
40 40
20 20
0 0
104 105 106 107 Hz 108 104 105 106 107 Hz 108
f f
B84112G0000M136
100
dB
a
80
60
40
20
0
104 105 106 107 Hz 108
f
3) The KU value (symbol KU) is a classification parameter of safety−referred failure types designed to ensure protection against hazardous
body currents and excessive heating.
A value of KU = 4.5 with respect to interruptions is attained:
− with a permanently connected protective earth circuit 1.5 mm2
− with a protective earth circuit 2.5 mm2 connected via shroud connectors (IEC 60309−2).
KU = 6 with respect to interruptions is achieved for fixed−connection lines 10 mm2 where the type of connection and line layout corre-
spond to the requirements for PEN conductors as specified in relevant standards.
Important notes