Professional Documents
Culture Documents
B
2
ARCHITECTURAL
A03
REY
SINGLE-STO
4 L BUILDING
RESIDENTIA
A03
A
A04
C
A
A04
D
STRUCTURAL
1 EXTERIOR PERSPECTIVE
A01
E
F
SANITARY
G
J
ELECTRICAL
ANAY
1
SITE
TAMO
BANAYB SCHOOL
TARY
ELEMEN
BANAYBANAY 1ST,
SAN JOSE BATANGAS
LAUREL HIGHWAY
S LOMI
PINKY' E
HOUS
NAPA DESIGN
RICHMOND'S
PRESIDENT JOSE P.
& BUILD
LPG TRADING
TAMO
INGASO
K MECHANICAL
L
1
A03
B
A04
FIRE PROTECTION
REPUBLIC ACT 9266 ARCHITECTURAL LAW 2004 SUBMITTED BY: PROJECT TITLE OWNER SHEET CONTENTS DESIGNED BY : PUNTO, J.P.A. SHEET NO.
ARTICLE III SECTION 20 (5):
ALL ARCHITECTURAL DRAWINGS, PLANS, DESIGNS, SPECIFICATIONS AND ARCHITECTURAL DOCUMENTS RELATIVE TO THE
EXTERIOR PERSPECTIVE PUNTO, J.P.A.
BATANGAS STATE UNIVERSITY CONSTRUCTION OF A BUILDING SHALL BEAR THE SEAL AND SIGNATURE ONLY OF AN ARCHITECT REGISTERED AND LICENSED
UNDER THE ACT.
DRAWN BY :
3 7190
A03
2017
5220
1 2 3 4 5 6 7
2060
1 2 3 4 5 6 7
B
A04 B
A04
3
RD RD
A03 3
A03
RD
5190
A
1800 1465 1925
W
1400
LAUNDRY
A AREA
+700
A
W
1400
800 MASTER'S
B
W W
LAUNDRY T&B
w
4 1 MASTER
900
W C3-F3
w
4 AREA 3000
BEDROOM
MASTER'S MASTER C3-F3
581 C1-F1
2925
3050 2950
W
T&B BEDROOM
1
2050
+750 +800
D
900
850
16740
2
1213
1367
D
WIC 4
+800
D WIC
12800
C1-F1
3 2950 1020 4 2
B B
665 593 A03 A03
675
W
375
W
4173
KITCHEN
DINING
AREA
1 1290 1050 300
C
663
+750
+750
85
2675
0
A A
DINING 1350
KITCHEN
AREA
85
0
A03 A03
12800
C3-F3
10000
1450
3000 C3-F3
4 W 2 3000
1
A03 A03 4 2
A03 1290 1050 300 A03
300
300
C D
3
C
E
D
W
LIVING 1 300 300
COMMON LIVING
A AREA A BEDROOM
+750
A AREA A
A04 COMMON A04 C1-F1
2950 85
C1-F1
2827
3000
2825
BEDROOM
+800
A04 0 A04
300 300
85
0
28240
W
1 E
27410
W W
RD
2 2
D D
300
FOYER
300
RD RD
300
D W
W D
FOYER 4 W E PORCH C1-F1
650
+750 3000
PWR 5
1600
1575
3 1 +700
C3-F3
3050 PWR
661 C3-F3
PORCH 3050
650
+700 899
812
E F
747
250
E
E
W
OUTDOOR
1400
C2-F2
3050
1000
W
250
2000 1640 1550
5190
1000
250
1
A03 1
A03
1000
250
B
A04 B
A04
1000
12550
1 GROUND FLOOR PLAN 2 REFLECTED CEILING PLAN
A02
A02
6500
LIGHTING LEGENDS
PENDANT LIGHT
CEILING LEGENDS
RECESSED DOWN LIGHT
C1-F1 ENGINEERED WOOD PANEL
WATER-BASED K
POLYURETHANE FINISH
VANITY LIGHT
B
A04
3 ROOF PLAN
A02
REPUBLIC ACT 9266 ARCHITECTURAL LAW 2004 SUBMITTED BY: PROJECT TITLE OWNER SHEET CONTENTS DESIGNED BY : PUNTO, J.P.A. SHEET NO.
ARTICLE III SECTION 20 (5):
ALL ARCHITECTURAL DRAWINGS, PLANS, DESIGNS, SPECIFICATIONS AND ARCHITECTURAL DOCUMENTS RELATIVE TO THE
PUNTO, J.P.A.
BATANGAS STATE UNIVERSITY CONSTRUCTION OF A BUILDING SHALL BEAR THE SEAL AND SIGNATURE ONLY OF AN ARCHITECT REGISTERED AND LICENSED
UNDER THE ACT.
GROUND FLOOR PLAN DRAWN BY :
1 2 3 4 5 6 7 L K J I H G F E D C B A
STANDING SEAM METAL ROOF
TPO MEMBRANE ROOFING
400
400
ROOF APEX
ROOF APEX LITEBLOCK WALL ( CONCRETE BLOCK)
+4700
300
650
+4700 TOP OF BEAM
300
650
TOP OF BEAM ALUMINUM SEAMLESS GUTTER
+4050
+4050
STANDING SEAM METAL ROOF
TPO MEMBRANE ROOFING
AWNING WINDOW with FINISHED CEILING LINE LITEBLOCK WALL ( CONCRETE BLOCK)
3000
FINISHED CEILING LINE
3000
5100
CONCEALING CLADDING FIBER GLASS SEAMLESS AWNING WINDOW +3750
5100
+3750
750
+750
NATURAL GRADE LINE
750
A A
A03 A2
A A
A03 A2
7 6 5 4 3 2 1 A B C D E F G H I J K L
LITEBLOCK WALL ( CONCRETE BLOCK) STANDING SEAM METAL ROOF
TPO MEMBRANE ROOFING
ROOF APEX ROOF APEX
+5100 +5100
ACCOYA WOOD CLADDING
400
400
ROOF APEX LITEBLOCK WALL ( CONCRETE BLOCK) ROOF APEX
+4700 +4700
300
300
650
650
TOP OF BEAM TOP OF BEAM
+4050 +4050
FINISHED CEILING LINE FIBER GLASS SEAMLESS AWNING WINDOW FINISHED CEILING LINE
3000
3000
5100
5100
+3750 +3750
750
A A
LITEBLOCK WALL ( CONCRETE BLOCK)
A03 A2
REPUBLIC ACT 9266 ARCHITECTURAL LAW 2004 SUBMITTED BY: PROJECT TITLE OWNER SHEET CONTENTS DESIGNED BY : PUNTO, J.P.A. SHEET NO.
ARTICLE III SECTION 20 (5):
ALL ARCHITECTURAL DRAWINGS, PLANS, DESIGNS, SPECIFICATIONS AND ARCHITECTURAL DOCUMENTS RELATIVE TO THE
PUNTO, J.P.A.
BATANGAS STATE UNIVERSITY CONSTRUCTION OF A BUILDING SHALL BEAR THE SEAL AND SIGNATURE ONLY OF AN ARCHITECT REGISTERED AND LICENSED
UNDER THE ACT.
FRONT ELEVATION DRAWN BY :
1 2 3 4 5 6 7 A B C D E F G H I J K L
LITEBLOCK WALL ( CONCRETE BLOCK)
400
400
ROOF APEX ROOF APEX
+4700 +4700
300
300
650
650
TOP OF BEAM TOP OF BEAM
+4050 +4050
3000
3000
5100
5100
+3750 +3750 CALIBRATED SLATE TILE
750
750
NATURAL GRADE LINE NATURAL GRADE LINE
+000 +000
LIGHT VINYL PLANK FLOORING FIBER GLASS SEAMLESS AWNING WINDOW
LIGHT VINYL PLANK FLOORING
WAVY GLASS BLOCKS WITH METALLIZED EDGE WAVY GLASS BLOCKS WITH METALLIZED EDGE
500
500
500
500
500
ELEVATION
2950
2950
2950
2950
2950
2450
2450
2450
2450
2100
2100
2100
2100
2100
700
450
970
970
970
970
700
F.F.L.
PLAN
QUANTITY ONE (1) SET ONE (1) SET TWO (2) SETS ONE (1) SET ONE (1) SET SIX (6) SETS TWO (2) SETS ONE (1) SET TWO (2) SETS ONE (1) SET
REPUBLIC ACT 9266 ARCHITECTURAL LAW 2004 SUBMITTED BY: PROJECT TITLE OWNER SHEET CONTENTS DESIGNED BY : PUNTO, J.P.A. SHEET NO.
ARTICLE III SECTION 20 (5):
ALL ARCHITECTURAL DRAWINGS, PLANS, DESIGNS, SPECIFICATIONS AND ARCHITECTURAL DOCUMENTS RELATIVE TO THE
PUNTO, J.P.A.
BATANGAS STATE UNIVERSITY CONSTRUCTION OF A BUILDING SHALL BEAR THE SEAL AND SIGNATURE ONLY OF AN ARCHITECT REGISTERED AND LICENSED CROSS SECTION DRAWN BY :