Professional Documents
Culture Documents
Catalogo Jard
Catalogo Jard
JARD by MARS
Table of Contents
JARD by MARS
Capacitors
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .J-7
Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . J-11
JARD by MARS
Single Section Run Capacitors
Features:
• JARD provides a low cost alternative to popular models and the
widest selection of ratings in the industry
• Non-PCB capacitors
• Physical interrupter makes our capacitors safe
• Perfect for general replacements
• Capacitor accessories – see page J-7
• UL and CSA listings available
Dual Section Motor Run Capacitors DUAL SECTION 370 VOLT ROUND
CASE HEIGHT DEPTH
JARD NO. MICROFARAD
Dual section run capacitors are INCHES INCHES
used primarily to serve two 12701 15/3 3.13 2.00
microfarad applications. They 12702 15/4 3.13 2.00
can, however, by making various 12703 15/5 3.13 2.00
combinations of parallel 12704 15/10 3.13 2.00
connections, be used to obtain 12705 17.5/4 3.13 2.00
many other microfarad ratings. 12706 17.5/5 3.13 2.00
12707 20/4 3.13 2.00
12760 20/5 3.13 2.00
Features: 12716 20/7.5 2.63 2.00
• Non-PCB capacitors 12708 20/10 3.13 2.00
Physical interrupter makes 12709 20/15 3.13 2.00
our capacitors safe 12711 25/3 3.13 2.00
12841 12875 25/4 3.13 2.00
• Perfect for general
12761 25/5 3.63 2.00
replacements
12762 25/7.5 3.13 2.00
• Capacitor accessories – see 12713 25/10 3.13 2.00
page J-7 12720 30/3 3.13 2.00
• UL and CSA listings available 12763 30/4 3.13 2.00
12764 30/5 3.13 2.00
12724 30/7.5 3.13 2.00
DUAL SECTION 370 VOLT OVAL 12728 30/10 3.13 2.00
CASE HEIGHT WIDTH DEPTH 12939 30/15 3.63 2.00
JARD NO. MICROFARAD
INCHES INCHES INCHES 12730 35/3 3.13 2.00
12841 15/3 2.63 2.81 1.81 12731 35/4 3.13 2.00
12956 15/4 2.63 2.81 1.81 12766 35/5 3.13 2.00
12957 15/5 2.63 2.81 1.81 12735 35/7.5 2.63 2.00
12958 15/10 2.38 2.81 1.81 12738 35/10 3.13 2.00
12959 17.5/4 2.63 2.81 1.81 12739 40/3 3.13 2.00
12960 17.5/5 2.63 2.81 1.81 12767 40/4 3.13 2.00
12961 20/3 2.63 2.81 1.81 12878 40/5 3.13 2.00
12962 20/4 3.13 2.81 1.81 12768 40/7.5 3.13 2.00
12963 20/5 2.63 2.81 1.81 12746 40/10 3.13 2.00
12864 20/10 2.63 2.81 1.81 12747 45/3 3.13 2.00
12964 20/15 2.63 2.81 1.81 12947 45/4 3.13 2.00
12842 25/3 2.63 2.81 1.81 12769 45/5 3.13 2.00
12965 25/4 2.63 2.81 1.81 12749 45/7.5 3.13 2.00
12966 25/5 2.63 2.81 1.81
12750 45/10 3.13 2.00
12843 25/7.5 2.63 2.81 1.81
12753 50/3 3.13 2.00
12832 25/8 2.63 2.81 1.81
12755 50/5 3.13 2.00
12867 25/10 2.63 2.81 1.81
12825 50/7.5 3.88 2.00
12833 25/15 2.63 2.81 1.81
12844 30/3 2.63 2.81 1.81 12757 50/10 3.88 2.00
12845 30/4 2.63 2.81 1.81 12893 55/5 3.88 2.00
12969 30/5 2.63 2.81 1.81 12894 55/7.5 3.88 2.00
12846 30/7.5 2.63 2.81 1.81 12967 55/10 3.88 2.00
12847 30/10 2.63 2.81 1.81 12976 60/3 3.88 2.00
12848 35/3 2.63 2.81 1.81 12895 60/5 3.88 2.00
12971 35/4 3.00 2.81 1.81 12896 60/7.5 3.88 2.00
12972 35/5 2.63 2.81 1.81 12865 60/10 3.88 2.00
12849 35/7.5 2.63 2.81 1.81 12742 65/5 3.88 2.00
12850 35/10 2.63 2.81 1.81 12953 70/5 4.75 2.00
12851 40/3 3.00 2.81 1.81 12954 70/7.5 4.75 2.00
12858 40/4 2.63 2.81 1.81 12955 70/10 4.75 2.00
12871 40/5 3.00 2.81 1.81 12744 75/5 4.75 2.00
12852 40/7.5 2.63 2.81 1.81 12946 75/7.5 4.75 2.00
12834 40/10 3.00 2.81 1.81
12984 75/10 4.75 2.00
12874 45/5 3.00 2.81 1.81
12897 80/5 4.75 2.00
12853 45/7.5 3.00 2.81 1.81
12819 80/7.5 4.75 2.00
12836 45/10 3.75 2.81 1.81
12824 80/10 4.75 2.00
12837 45/15 3.75 2.81 1.81
12838 50/5 3.75 2.81 1.81 12722 80/12.5 4.75 2.00
12854 55/5 3.75 2.81 1.81 12829 85/5 4.75 2.00
12855 55/7.5 3.75 2.81 1.81 12756 85/7.5 4.75 2.00
12839 60/5 4.75 2.81 1.81 12922 85/10 4.75 2.00
12856 60/7.5 3.75 2.81 1.81
*Capacitors may be put in different case sizes occasionally, but will not be larger than those stated.
12857 60/10 3.75 2.81 1.81
12859 65/5 4.75 2.81 1.81 Base Dimensions on page J-5
12863 80/5 4.75 3.56 1.88
12817 80/7.5 4.75 2.81 1.81
JARD by MARS
Capacitor Base Dimensions DUAL SECTION 440/370 VOLT ROUND
CASE HEIGHT DEPTH
JARD NO. MICROFARAD
Capacitor accessories – see INCHES INCHES
page J-7 12811 10/5 3.13 2.00
12818 15/5 3.13 2.00
12656 15/10 3.63 2.00
12650 17.5/5 3.63 2.00
12780 20/5 3.63 2.00
12654 20/7.5 3.63 2.00
12651 20/10 3.13 2.00
12812 20/15 3.13 2.00
DEPTH 12653 25/3 3.13 2.00
12655 25/4 3.13 2.00
12778 25/5 3.63 2.00
12779 25/7.5 3.13 2.00
12780
12813 25/10 3.13 2.00
12814 25/15 3.13 2.00
12826 30/3 3.13 2.00
DEPTH 12820 30/4 3.13 2.00
12781 30/5 3.13 2.00
12782 30/7.5 3.13 2.00
HEIGHT 12652 30/10 3.88 2.00
12977 35/3 3.88 2.00
12870 35/4 3.88 2.00
12783 35/5 3.13 2.00
WIDTH 12719 35/6 3.88 2.00
12784 35/7.5 3.88 2.00
12797 35/10 3.88 2.00
DUAL SECTION 440/370 VOLT OVAL
12978 40/3 3.88 2.00
CASE HEIGHT WIDTH DEPTH 12785 40/4 3.88 2.00
JARD NO. MICROFARAD
INCHES INCHES INCHES
12786 40/5 3.88 2.00
12660 5/5 2.63 2.81 1.81 12920 40/6 3.88 0.00
12765 10/5 2.63 2.81 1.81 12787 40/7.5 3.88 2.00
12970 10/10 2.63 2.81 1.81 12798 40/10 3.88 2.00
12770 15/4 2.63 2.81 1.81 12979 45/3 3.88 2.00
12771 15/5 2.63 2.81 1.81 12891 45/4 3.88 2.00
12777 15/10 2.63 2.81 1.81
12788 45/5 3.88 2.00
12880 20/5 2.63 2.81 1.81
12827 45/6 3.88 2.00
12983 20/15 3.00 3.56 1.88
12789 45/7.5 3.88 2.00
12884 25/5 2.63 2.81 1.81
12872 45/10 3.88 2.00
12882 25/7.5 3.00 2.81 1.81
12790 50/5 3.88 2.00
12883 25/10 3.00 2.81 1.81
12791 50/7.5 4.75 2.00
12886 25/15 3.75 2.81 1.81
12892 50/10 4.75 2.00
12881 30/4 3.75 2.81 1.81
12792 55/5 4.75 2.00
12887 30/5 3.00 2.81 1.81
12793 55/7.5 4.75 2.00
12982 30/7.5 3.75 2.81 1.81
12799 55/10 4.75 2.00
12835 30/10 3.75 2.81 1.81
12985 35/3 3.00 2.81 1.81 12860 60/3 4.75 2.00
12879 35/4 3.75 2.81 1.81 12794 60/5 4.75 2.00
12885 35/5 3.75 2.81 1.81 12795 60/7.5 4.75 2.00
12888 35/7.5 3.00 2.81 1.81 12796 60/10 4.75 2.00
12876 35/8.5 3.00 2.81 1.81 12861 60/12.5 4.75 2.00
12772 35/10 3.75 2.81 1.81 12642 65/5 4.75 2.00
12877 40/3 3.75 2.81 1.81 12659 65/7.5 4.75 2.00
12986 40/5 3.75 2.81 1.81 12862 65/10 3.88 2.50
12889 40/7.5 3.75 2.81 1.81 12823 70/5 3.88 2.50
12773 40/10 3.75 2.81 1.81 12866 70/7.5 3.88 2.50
12890 45/5 4.75 2.81 1.81 12869 70/10 3.88 2.50
12774 45/7.5 4.75 2.81 1.81 12968 75/5 3.88 2.50
12808 50/5 4.75 2.81 1.81 12901 75/7.5 3.88 2.50
12913 50/7.5 4.75 2.81 1.81 12935 75/10 3.88 2.50
12775 55/5 4.75 2.81 1.81 12801 80/5 3.88 2.50
12822 55/10 4.75 2.81 1.81 12816 80/7.5 3.88 2.50
12809 60/5 4.75 2.81 1.81 12821 80/10 3.88 2.50
12776 60/7.5 4.75 2.81 1.81 12938 85/5 4.75 2.50
12810 65/10 4.75 3.56 1.88 12942 85/7.5 4.75 2.50
12815 80/5 4.75 3.56 1.88 12944 85/10 4.75 2.50
12898 80/7.5 4.75 3.56 1.88
*Capacitors may be put in different case sizes occasionally, but will not be larger than those stated.
JARD by MARS
QC-6 Kit Protector (boots) for
Motor Run Capacitors
93001
For conversion of screw-type 93011 1 Hole Boot
connections on relays 93012 2 Hole Boot
Features:
• 2 styles: screw terminals with quick connects or lug terminals with quick
connects
17999
• UL (both styles)
• CSA (screw terminal style) 17125
• CUL (lug terminal style)
JARD JARD FULL LOAD RESISTIVE JARD JARD FULL LOAD RESISTIVE
COIL VOLTAGE POLES COIL VOLTAGE POLES
W/LUGS W/SCREWS AMPS AMPS W/LUGS W/SCREWS AMPS AMPS
17416 – 40 50 120 1-1/2 17998 Auxiliary Contact- Fits 50 & 60A 3P models
JARD by MARS
General Purpose Switching Relays
SPDT 92293
92294
92293 24 8 amps 16 amps 90-293, 90-293Q 92295
92294 110-120 continuous 16 amps 90-294, 90-294Q 92293
92295 208/240 25 amps inrush 16 amps 90-295, 90-295Q
JARD Heavy Duty Fan Relays JARD Heavy Duty Fan Relays
are used on heating and air are used on heating and air
conditioning equipment to conditioning equipment to
provide switching of heavier provide switching of heavier
loads with a compact size relay. loads with a compact size relay.
Features: Features:
• 25 Amp switching • 25 Amp switching
• Compact and totally enclosed • Universal mounting bracket
• Quick-connect terminals • Quick-connect terminals
• Tab bracket, Non-positional • UL and CUR
92370 92340
• UL and CUR
Terminal Identification
1 3
4 6
COIL
5 Terminals 1& 2, 4 & 5 are normally closed
Terminals 1& 3, 4 & 6 are normally open
Contact Rating
POWER PILOT
208/240V 208/240V
Specifications:
Features:
• Contacts rated at 6 amps,
• Tamper proof construction 24-240 volts
• Direct mounting on tubing • 1/4" female flare S.A.E.
mounting
Specifications: • 18" leads
• Contacts rated at 6 amps, • UL & CSA recognized
24-240 volts
• 1/4" female flare S.A.E.
mounting
• 18" leads Low Pressure Controls, Open on Pressure Fall,
• UL & CSA recognized
Automatic Reset, Normally Open
OPENING RESET
JARD NO. DESCRIPTION MOUNTING
PRESSURE PRESSURE
High Pressure Cut-Outs, Open on Pressure Rise,
5/20 LP 1/4" Female Flare Fitting S.A.E.
Automatic Reset, Normally Closed 43941 5 20
Open on fall Mounting
400/200 HP 1/4" Female Flare Fitting S.A.E. 40/80 LP 1/4" Female Flare Fitting S.A.E.
43929 400 200 43950 40 80
Open on rise Mounting Open on fall Mounting
400/280 HP 1/4" Female Flare Fitting S.A.E. 45/60 LP 1/4" Female Flare Fitting S.A.E.
43930 400 280 43951 45 60
Open on rise Mounting Open on fall Mounting
400/300 HP 1/4" Female Flare Fitting S.A.E. 50/90 LP 1/4" Female Flare Fitting S.A.E.
43931 400 300 43952 50 90
Open on rise Mounting Open on fall Mounting
410/290 HP 1/4" Female Flare Fitting S.A.E. 75/100 LP 1/4" Female Flare Fitting S.A.E.
43911 410 290 43953 75 100
Open on rise Mounting Open on fall Mounting
425/300 HP 1/4" Female Flare Fitting S.A.E. 90/120 LP 1/4" Female Flare Fitting S.A.E.
43932 425 300 43975 90 120
Open on rise Mounting Open on fall Mounting
425/325 HP 1/4" Female Flare Fitting S.A.E. 150/225 LP 1/4" Female Flare Fitting S.A.E.
43933 425 325 43954 150 225
Open on rise Mounting Open on fall Mounting
450/250 HP 1/4" Female Flare Fitting S.A.E. 170/225 LP 1/4" Female Flare Fitting S.A.E.
43934 450 250 43955 170 225
Open on rise Mounting Open on fall Mounting
590/418 HP 1/4" Female Flare Fitting S.A.E.
43965 590 418
Open on rise Mounting
600/475 HP 1/4" Female Flare Fitting S.A.E.
43935 600 475
Open on rise Mounting
630/480 HP 1/4" Female Flare Fitting S.A.E.
43939 630 480
Open on rise Mounting
JARD by MARS
Condenser Fan Cycling Switch JARD Fuses
Applications:
Manual Reset high pressure • Recommended for AC power distribution system mains,
controls feeders, and branch circuits.
• Protection of motors and motor
branch circuits.
Specifications: • Protection of transformers and
• UL & CSA recognized other inductive loads.
• All general-purpose applications
including lighting, heating and
other non-inductive loads.
Benefits:
• Superior overload and
cycling capabilities.
• Current limiting provides
43903 component short-
circuit protection.
Specifications:
Dual-Element Time-Delay
SWITCH Voltage Rating: RK5 - 250Vac,
JARD OPENING RESET ACTION RK5 - 600Vac
DESCR. MOUNTING
NO. PRESSURE PRESSURE (OPEN ON Amp Rating: 1/10 - 600A
PRESSURE) Interrupting Rating: 200,000 RMS Symmetrical Amps
Current Limiting: RK5 Fuse
75/100 FC 1/4" Female Flare Fitting
43901 75 100 Fall Agency Approvals:
Close on rise S.A.E. Mounting
UL Listed, Class RK5, CSA Certified, DC listed to UL standard
248 TRS only
110/170 FC 1/4" Female Flare Fitting Voltage Rating: RK5 250V
43902 110 170 Fall
Close on rise S.A.E. Mounting
Volts: 250VAC
: 250VDC (.1-2.8A; 35-400A)
125/265 FC 1/4" Female Flare Fitting : 160VDC (3-30A; 450-600A)
43903 125 265 Fall
Close on rise S.A.E. Mounting RK5 600V
Volts: 600VAC
150/225 FC 1/4" Female Flare Fitting : 600VDC (.1-12A; 70-600A)
43904 150 225 Fall
Close on rise S.A.E. Mounting : 160VDC (15-60A)
180/240 FC 1/4" Female Flare Fitting RK5 Time Delay Fuse 250V RK5 Time Delay Fuse 600V
43970 180 240 Fall
Close on rise S.A.E. Mounting Replaces: TR, ECNR, Replaces: TRS, ECSR,
FRNR, FLNR FRSR, FLSR
19/275 FC 1/4" Female Flare Fitting
43905 190 275 Fall MARS MARS MARS MARS
Close on rise S.A.E. Mounting DESCRIPTION DESCRIPTION
NO. PACK NO. PACK
81006 .5A - 250V 10 81103 .2A - 600V 10
210/275 FC 1/4" Female Flare Fitting 81009 1A - 250V 10 81106 .5A - 600V 10
43906 210 275 Fall 81016 2A - 250V 10
Close on rise S.A.E. Mounting 81109 1A - 600V 10
81017 2.5A - 250V 10 81110 1.6A - 600V 10
81019 3A - 250V 10 81111 2A - 600V 10
300/400 FC 1/4" Female Flare Fitting 81020 3.2A - 250V 10
43907 300 400 Fall 81112 2.25A - 600V 10
Close on rise S.A.E. Mounting 81021 4A - 250V 10
81024 5A - 250V 10 81124 5A - 600V 10
81025 5.6A - 250V 10 81125 6A - 600V 10
375/Man. Open 1/4" Female Flare Fitting 81026 6A - 250V 10 81132 10A - 600V 10
43912 375 Manual Rise
on rise S.A.E. Mounting 81027 6.25A - 250V 10 81133 12A - 600V 10
81029 7A - 250V 10 81134 15A - 600V 10
410/Man. Open 1/4" Female Flare Fitting 81030 8A - 250V 10 81136 20A - 600V 10
43913 410 Manual Rise 81032 10A - 250V 10 81137 25A - 600V 10
on rise S.A.E. Mounting
81033 12A - 250V 10 81138 30A - 600V 10
81034 15A - 250V 10 81139 35A - 600V 10
475/Man. Open 1/4" Female Flare Fitting 81035 17.5A - 250V 10 81140 40A - 600V 10
43916 475 Manual Rise 81036 20A - 250V 10
on rise S.A.E. Mounting 81147 45A - 600V 10
81037 25A - 250V 10
81038 30A - 250V 10 81141 50A - 600V 10
81039 35A - 250V 10 81142 60A - 600V 10
81040 40A - 250V 10 81143 70A - 600V 5
81041 45A - 250V 10 81144 80A - 600V 5
81042 50A - 250V 10 81145 90A - 600V 5
81043 60A - 250V 10 81146 100A - 600V 5
81044 70A - 250V 5 81154 110A - 600V 1
81045 80A - 250V 5 81148 125A - 600V 1
81046 90A - 250V 5 81149 150A - 600V 1
81047 100A - 250V 5
81150 175A - 600V 1
81048 110A - 250V 1
81049 125A - 250V 1 81151 200A - 600V 1
81050 150A - 250V 1 81152 250A - 600V 1
81051 175A - 250V 1 81153 300A - 600V 1
81052 200A - 250V 1
81053 225A - 250V 1
81054 350A - 250V 1
81056 400A - 250V 1
81055 600A - 250V 1
15119* 9 115 CW 0.62 13" 22404 EM3404 SE3338 WG840204 40825 1874
22405 EM3405 SE3339 WG840205 30825 1875
15411 9 115 CW 0.62 24" 22746 EM3746 - - - 1870
22727 EM3727 SE3727 WG840727 43727 1859
15412 9 115 CCW 0.62 24" 22728 EM3728 SE3728 WG840728 43728 1860
22729 EM3729 SE3729 WG840729 43729 1861
15421 9 230 CW 0.33 24"
22730 EM3730 SE3730 WG840730 43730 1862
22731 EM3731 SE3731 WG840731 43731 1868
15422 9 230 CCW 0.33 24"
Reversible Rotation – Single Speed
15811 16 115 CW 0.95 24"
MARS CAP DIMENSIONS LEAD
HP VOLTS AMPS ENCL. BRG.
15812 16 115 CCW 0.95 24" NO. REQ. A B C LENGTHS
1075 RPM
15821 16 230 CW 0.48 24"
22727 1/6 208-230 0.90 5/370 TEAO Ball 6.50 4.23 1/2 26"
15822 16 230 CCW 0.48 24"
22728 1/4 208-230 1.8 5/370 TEAO Ball 6.50 4.23 1/2 26"
* Note: 13" lead with lyall plug 22729 1/3 208-230 2.4 7.5/370 TEAO Ball 6.50 5.23 1/2 26"
22730 1/2 208-230 3.5 10/370 TEAO Ball 6.50 5.73 1/2 26"
22731 3/4 208-230 5.2 10/370 TEAO Ball 6.50 6.23 1/2 30.5"
825 RPM
22403 1/6 208-230 1.0 5/370 TEAO Ball 6.50 4.23 1/2 36"
22404 1/4 208-230 1.6 5/370 TEAO Ball 6.50 4.48 1/2 36"
22405 1/3 208-230 1.9 7.5/370 TEAO Ball 6.50 5.23 1/2 36"
22746 1/2 208-230 2.8 12.5/370 TEAO Ball 6.50 5.70 1/2 36"
JARD by MARS
Direct Drive Blower Motors Multi-Horsepower
Direct Drive Motors
JARD direct drive blower motors
are Ideal for use in commercial JARD multi-horsepower direct
and residential furnaces and drive blower motors are used in
air-conditioners. All models are residential and commercial
three speed standard efficiency furnaces, air conditioners,
and are electrically reversible. exhaust fans, and other air
handling equipment installed in
Features:
clean and dry environments. Four
• All angle sleeve bearing models cover both 115 and
• Rheem mounting holes 208-230 volt applications from 1/6
• 3 speeds through 3/4 HP. All models feature
• 1/2 inch extended thru bolts Rheem shell mounting holes.
• 2-1/4 inch resilient rings Features:
• 4 inch long, 1/2 inch • Rheem mounting holes
diameter shaft • Reversible rotation
Specifications: • 2-1/4 inch resilient rings
• Class “B” insulation Specifications:
• Single phase, 60 Hertz • Class “B” insulation
• Thermal overload protected • Single phase, 60 Hz
• Fan duty, continuous, air over • Thermal overload protected
• Open construction • 41 inch leads
• 26 & 30 inch leads • UL Recognized
• UL Recognized
Cross Reference:
Cross Reference:
JARD SMART WAGNER/ US MOTORS/
JARD SMART WAGNER/ US MOTORS/ ECONOMASTER PACKARD
ECONOMASTER PACKARD NO. ELECTRIC DIVERSITECH EMERSON
NO. ELECTRIC DIVERSITECH EMERSON
22463 EM3463 SE3463 WG840463 45460 5460
22583 EM3583 SE3583 WG840583 43583 1863 22464 EM3464 SE3464 WG840464 45461 5461
22584 EM3584 SE3584 WG840584 43584 1971 22466 EM3466 SE3466 WG840466 45470 5470
22585 EM3585 SE3585 WG840585 43585 1864 22467 EM3467 SE3467 WG840467 45471 5471
22586 EM3586 SE3586 WG840586 43586 1972
22587 EM3587 SE3587 WG840587 43587 1865
22588 EM3588 SE3588 WG840588 43588 1973
1075 RPM - Four Speed - Reversible Rotation
22589 EM3589 SE3589 WG840589 43589 8904 MARS DIMENSIONS LEAD
HP ROT VOLTS ENCL. BRG.
22590 EM3590 SE3590 WG840590 43590 8905 NO. A B C LENGTHS
22463 1/6 - 1/2 Rev 115 OAO Sleeve 5.50 4.73 1/2 42"
1075 RPM – Three Speed – Reversible Rotation 22464 1/6 - 1/2 Rev 230 OAO Sleeve 5.50 4.73 1/2 41"
MARS CAP DIMENSIONS LEAD 22466 1/5 - 3/4 Rev 115 OAO Ball 5.80 5.73 1/2 41"
HP ROT VOLTS AMPS ENCL. BRG.
NO. REQ. A B C LENGTHS
22467 1/5 - 3/4 Rev 230 OAO Ball 4.60 5.23 1/2 41"
22583 1/4 Rev 115 4.2 5/370 OAO Sleeve 4.50 4.89 1/2 26"
22584 1/4 Rev 208-230 1.8 5/370 OAO Sleeve 4.50 4.89 1/2 26"
22585 1/3 Rev 115 6.1 5/370 OAO Sleeve 4.50 5.14 1/2 30"
22586 1/3 Rev 208-230 2.7 5/370 OAO Sleeve 4.50 5.14 1/2 26"
22587 1/2 Rev 115 7.5 10/370 OAO Sleeve 4.50 5.89 1/2 30"
22588 1/2 Rev 208-230 3.2 7.5/370 OAO Sleeve 4.50 5.64 1/2 30"
22589 3/4 Rev 115 11.2 15/370 OAO Sleeve 4.50 6.14 1/2 30"
22590 3/4 Rev 208-230 4.5 10/370 OAO Sleeve 4.50 6.14 1/2 30"
JARD by MARS
Multi-Horsepower JARD Cross Reference:
Condenser Fan Motors
Ball Bearing JARD
ECONOMASTER
SMART WAGNER/
PACKARD
US MOTORS/
NO. ELECTRIC DIVERSITECH EMERSON
JARD multi-horsepower
condenser fan motors are 70˚C 22403 EM3403 - - 60825 1873
designed for either shaft up or 22404 EM3404 SE3338 WG840204 40825 1874
shaft down applications. All
22405 EM3405 SE3339 WG840205 30825 1875
motors are suitable for air
conditioning or heat pump 22746 EM3746 - - - 1870
applications. These motors need 22727 EM3727 SE3727 WG840727 43727 1859
to be mounted within the airflow
of the fan for proper cooling. 22728 EM3728 SE3728 WG840728 43728 1860
26726 - - - - -