Test Load calculation for Load - Deflection test on 30.

5 m Non standard (5 leaf) Composite Girder Bridge

SN Description Qty. Unit Reference


1
Dead Load of one Span:

from respective DODL (Calculation


Dead Load of Steel Girder: 236.72664 MT
Attached )

Dead Load Concrete Deck Slab: 351.636 MT From Site Quantity (Calculation attached )

Total Dead Load: 588.36264 MT


2 Super Imposed Dead Load of Ballast and Track:
Volume of Ballast per metre of span:
2.7 CUM As per Annexture -2/2(A) (Para 212) of IRPWM

Effective Span (Centre to centre of Bearings):


31.9 MTR 2017-18/J-790/ST-301 Series
Overall span
32.45 MTR 2017-18/J-790/ST-301 Series
Unit weight of Ballast: 1.6 MT/cum
Total weight of Ballast: 280.368 MT
Self weight of 60 Kg wider sleeper: 0.347 MT as per DWG
No. of sleeper: 110 Nos 1660/km
Total weight of sleeper: 38.077698 MT
Self weight of 60 Kg Rail: 60.34 Kg/Mtr As per DWG
Length of Rail: 129.8 MTR overall length*2 *2
Total weight of Rail: 7.832132 MT
Self weight of 60 Kg Guard Rail: 60.34 Kg/Mtr As per DWG
Length of Guard Rail: 129.8 MTR overall length*2 *2
Total weight of Guard Rail: 7.832132 MT
Lumpsum weight for fittings and Guard Rail screws: Assuming 6% weight of Guard Rail& main
0.940 MT
rail
Total SIDL of Ballast and Track: 335.050 MT

3 LIVE LOAD WITH IMPACT


EUDL for Bending Moment: As per page No. 84, Appendix - XXIII of
3050.596
Bridge Rule

6101.192

Impact factor or CDA 0.187


Total live load with impact load(IN Kn) 7244.72 (1+CDA)*Live Load
Total live load with impact load(IN MT) 738.76
Total Load 1662.17

Test Load(In MT) 1846.857679 MT Dead Load + 1.25* Live load with Impact