SR Vivodent®
SR Orthotyp®
SR Ortholingual®
S PE / S DCL
Exceptional prefabricated teeth
in DCL quality
✓ Square tooth moulds Posterior teeth relation in accordance with a normal bite situation.
With this angular shape, the central incisor is dominant. The vertical labial curvature is
This tooth mould chart facilitates the selection of posterior tooth sizes to match the Minimum layer thickness
moderate.
selected anterior teeth. Ivoclar Vivadent offers a variety of posterior teeth, which give the It must be ensured that the stability of the teeth and the correct shade effect are
clinician the opportunity to select a tooth shape that will best meet the functional and maintained. It is therefore recommended to observe the minimum layer thickness.
Chairside
esthetic needs of the patient. – Anterior teeth: min. 2.5 mm
The facial meter allows fast and targeted selection of the appropriate anterior tooth size.
– Posterior teeth: Central fossa min. 2.0 mm, cusp tips min. 2.5 mm,
Step 1: Measure the interalar width of the nose with the facial meter and select the cervical area min. 2.5 mm
The sample teeth of the SR Vivodent S PE and SR Vivodent S DCL shade guide feature appropriate tooth size S/M/L.
the same layering structure and material as the marketed original teeth. Shade deviations Step 2: Select between triangular, oval and square tooth shapes within this size range.
will be consequently reduced to a minimum. The shade selection with the patient should The papillameter is the ideal device for the definition of the length of the upper lip and
be carried out under defined light conditions (5,500 K colour temperature) or during the lip closure line. Especially for the length of the anterior teeth, the lip closure line
daylight (preferably light from the north). provides one of the most important pieces of information.
Occlusal concepts
Classic occlusion Lingualized occlusion
A24B
A44
A22
A14
A54
A26
A27
12.7
A17
A11
11.8
10.8
11.0
11.5
11.4
9.6
9.7
9.3
7.9 7.7 7.9 8.8 8.4 9.0 9.7
41.6 41.3 41.8 47.0 8.8 47.0 43.9 48.7 45.9 8.9 51.0
A15
A12
A13
10.6
A42
A68
A25
10.2
11.7
10.5
11.5
10.1
42.6 8.0 42.8 8.4 46.0 8.9 44.1 8.6 48.8 9.0 48.8 9.1
A66
10.7
45.6 8.7
10.2
10.5
11.8
12.5
10.5
10.6
9.6
9.7
A10
A8
A6
A7
A4
A3
A5
A9
31.7 4.7 32.0 4.7 34.4 5.2 5.2 5.4 5.6 5.6 5.7
35.0 35.9 38.4 36.8 38.6
SR Orthotyp S PE / S DCL SR Ortholingual S DCL Processing Instructions Combination Table
Posteriors
Important SR Vivodent S PE | S DCL SR Orthotyp S PE | S DCL SR Ortholingual S DCL
29.5 31.1 (22°) (15°)
9.3 To ensure that removable dentures remain functional in the oral cavity over longer periods of time, the following
9.9
N3U
LU3
Anteriors Posteriors
– Dental materials may only be processed by dental professionals.
– Fabrication in the dental laboratory according to the principles of best practice. Upper Lower Upper/Lower Upper/Lower
– To ensure a reliable material bond between PMMA/composite teeth and the denture base material, clean the teeth
N3L
LL3
with steam, roughen them and apply monomer. When using an auto-curing polymer for finishing, it is recommended A22 A3, A4, A5 N3U/N3L, N4U/N4L LU3/LL3
31.9
9.0 8.5
to create additional mechanical retentions. A42 A3, A4, A5 N3U/N3L, N4U/N4L LU3/LL3
32.5
– The teeth should not come into contact with a flame or direct heat (e.g. alcohol torch).
30.6 32.6
– Heat development as a result of too much pressure during grinding must be prevented. Small A44 A3, A4, A5 N3U/N3L, N4U/N4L LU3/LL3
10.3 9.9 – Contact with solvents must be prevented.
N4U
LU5
A13 A3, A4, A5, A6 N3U/N3L, N4U/N4L LU3/LL3
N4L
LL5
9.3 9.0 A26 A7, A8 N4U/N4L, N5U/N5L LU5/LL5
33.3 34.3
LU6
A24B A6, A7, A8 N4U/N4L, N5U/N5L LU5/LL5
A66 A6, A7, A8 N4U/N4L, N5U/N5L
N5L
LL6
A27 A9, A10 N5U/N5L, N6U/N6L LU6/LL6
9.7 9.3
34.7 36.0 A68 A9, A10 N5U/N5L, N6U/N6L LU6/LL6
10.2
36.3
EN ISO 22112:2017 (D)
Descriptions and data constitute
no warranty of attributes.
Date information prepared: 2022-05/Rev. 1
688409/EN