Professional Documents
Culture Documents
X-Rail Roof Mounted - Plan Layout - Roof Top
X-Rail Roof Mounted - Plan Layout - Roof Top
10800 10800 10800 10800 10800 10800 10800 10800 10800 10800 (As per client markup)
Client: Rigcom
Ref #: ARCHITECTS REGISTRATION BOARD /
SafetyLink
Innovative Rev: 0 NOMINATED ARCHITECTS
Fall Protection
Prepared by: RS/NV NSW
9356 NINOTSCHKA TITCHKOSKY
QLD
5527 NEIL LOGAN
X-Rail System BQ 1 1
4937 JAMES GROSE
7115 JULIAN ASHTON
2709 BRIAN DONOVAN
1595 MARK GRIMMER
AR-10C XX-03
AR-10D XX-05
This plan and subsequent quote is a GUIDE 7053 MATTHEW BLAIR 5528 DAVID KELLY
(RL1) X-Rail - Surface Mounted(Klip-Lok 700 TBC) 144,982 mm measurements, systems, system locations 10705 CATHERINE SKINNER
Telephone +61 7 3852 2525
and structures be CHECKED ON-SITE prior Facsimile +61 7 3852 2544
(RL2) X-Rail - Surface Mounted(Klip-Lok 700 TBC) 47,374 mm www.bvn.com.au
to presenting to the client.
(RL3) X-Rail - Surface Mounted(Klip-Lok 700 TBC) 9,305 mm
(RL4) X-Rail - Surface Mounted(Klip-Lok 700 TBC) 195,164 mm INTELLECTUAL PROPERTY
01 01 COPYRIGHT BVN ARCHITECTURE PTY LIMITED. UNLESS OTHERWISE
AGREED IN WRITING;ALL RIGHTS TO THIS DOCUMENT ARE SUBJECT TO
PAYMENT IN FULL OF ALL BVN CHARGES;THIS DOCUMENT MAY ONLY
BE USED FOR THE EXPRESS PURPOSE AND PROJECT FOR WHICH IT
HAS BEEN CREATED AND DELIVERED, AS NOTIFIED IN WRITING BY
BVN;AND THIS DOCUMENT MAY NOT BE OTHERWISE USED, OR COPIED.
Note: Normal 90 ANY UNAUTHORISED USE OF THIS DOCUMENT IS AT THE USER'S SOLE
RISK AND WITHOUT LIMITING BVN'S RIGHTS THE USER RELEASES AND
8400
FL-001
RL1 FL-001 RL2 FL-001
TBC M 10/03/2023 For information - Building Shift
144,982 mm 9,305 mm 6,077 mm N 21/04/2023 For Coordination
RF-001 47,374 mm RF-001 O 05/05/2023 Package 2 Issue to DOMA for review
16,285 mm
03 RFG-001
03 P
Q
17/05/2023
02/06/2023
Final Base Building Design - Package 2
Package 3 Issue To Doma For Review
FL-001 FL-001 R 16/06/2023 Final Base Building Design - Package 3
S 01/08/2023 Final Base Building Design
RFG-001
T 01/09/2023 BA03 Submission
U 18/10/2023 For information
8400
WCT-002
RA PLENUM BUILDER
WCT-002
L6.07 COOLING TOWERS RA PLENUM 7,950 mm BLOC CONSTRUCTIONS (ACT)
L6.08 L6.09 CONTRACTOR
04 WCT-002 04 CONSULTANT
S4B STUDIO
SERVICES CONSULTANT
CONSULTANT
8400
INDESCO
05 BASE BUILDING
05 STRUCTURAL CONSULTANT
CONSULTANT
FLOATING
GENERATOR ROOM
OVERRUN
OVERRUN
SLAB TO REDBOX DESIGN GROUP
22,868 mm
GENERATOR L6.15
LANDSCAPE DESIGN
ROOMS ATRIUM
8400
DEVELOPMENT MANAGER
1
SKYLIGHT AR-10C XX-04
RFG-001
RFG-001
1
AR-10C XX-02
CHILLER ROOM
L6.18
06 1 GL 1 06
AR-10D XX-02 AR-10D XX-02
TENANCY GENERATOR
60,647 mm PROVISION RA PLENUM COM BMS H ELC TENANCY ELEC CUPD TENANCY ELEC CUPD H ELC
Roof flashing shown
L6.16
U
L6.14
DOMA
07 PLANT ROOM
07 CLIENT NUMBER
L6.01
RA PLENUM 1909010
7,950 mm
L6.10
FL-001
PROJECT
8400
RFG-001
RF-001 15 SYDNEY AVENUE
18,271 mm
WCT-002 BARTON
CANBERRA
08 08
WCT-002
WCT-002
4,250 mm L6.11
HEAT PUMPS 6,046 mm 1909010
L6.19
8400
10 RF-001 RF-001 10
RFG-003 GRAPHIC SCALE
DETAIL DESIGN
Note: Custom Corner
DRAWING
placed over ridge
1 1
AR-10D XX-05 AR-10C XX-01
A B C D E F G H I J K 1 : 200
AR-10B 06-01 U
C:\Users\bwong\REVIT_LOCAL\2022\AR_1909010_DOMA_ATO BUILDING_2022_brian-wong.rvt 18/10/2023 4:20:15 PM