You are on page 1of 1

A B C D E F G H I J K Job: X-Rail System - 15 Sydney Ave.

10800 10800 10800 10800 10800 10800 10800 10800 10800 10800 (As per client markup)
Client: Rigcom
Ref #: ARCHITECTS REGISTRATION BOARD /
SafetyLink
Innovative Rev: 0 NOMINATED ARCHITECTS
Fall Protection
Prepared by: RS/NV NSW
9356 NINOTSCHKA TITCHKOSKY
QLD
5527 NEIL LOGAN
X-Rail System BQ 1 1
4937 JAMES GROSE
7115 JULIAN ASHTON
2709 BRIAN DONOVAN
1595 MARK GRIMMER
AR-10C XX-03
AR-10D XX-05
This plan and subsequent quote is a GUIDE 7053 MATTHEW BLAIR 5528 DAVID KELLY

Description Quantity Unit ONLY. It is recommended that ALL


7151 PHILLIP ROSSINGTON
7439 PETER TITMUSS
3866 KEVIN O'BRIEN

10447 ALISON BOUNDS

(RL1) X-Rail - Surface Mounted(Klip-Lok 700 TBC) 143,530 mm measurements, systems, system locations 10705 CATHERINE SKINNER
Telephone +61 7 3852 2525
and structures be CHECKED ON-SITE prior Facsimile +61 7 3852 2544
(RL2) X-Rail - Surface Mounted(Klip-Lok 700 TBC) 46,398 mm to presenting to the client. www.bvn.com.au

(RL3) X-Rail - Surface Mounted(Klip-Lok 700 TBC) 9,305 mm


(RL4) X-Rail - Surface Mounted(Klip-Lok 700 TBC) 191,910 mm INTELLECTUAL PROPERTY
01 01 COPYRIGHT BVN ARCHITECTURE PTY LIMITED. UNLESS OTHERWISE
AGREED IN WRITING;ALL RIGHTS TO THIS DOCUMENT ARE SUBJECT TO
PAYMENT IN FULL OF ALL BVN CHARGES;THIS DOCUMENT MAY ONLY
BE USED FOR THE EXPRESS PURPOSE AND PROJECT FOR WHICH IT
HAS BEEN CREATED AND DELIVERED, AS NOTIFIED IN WRITING BY
plant facade BVN;AND THIS DOCUMENT MAY NOT BE OTHERWISE USED, OR COPIED.
Note: Normal 90 3,802 mm ANY UNAUTHORISED USE OF THIS DOCUMENT IS AT THE USER'S SOLE
RISK AND WITHOUT LIMITING BVN'S RIGHTS THE USER RELEASES AND
8400

Note: Custom Corner 33,961 mm


Degree Corners placed over ridge
INDEMNIFIES BVN FROM AND AGAINST ALL LOSS SO ARISING.
Note: Custom Corner
(Unless specified) placed over ridge 33,986 mm NOTE
Note: Custom Corner CONTRACTOR TO CHECK AND VERIFY ALL DIMENSIONS ON SITE PRIOR
placed over ridge TO COMMENCEMENT OF WORK OR PREPARATION OF SHOP DRAWINGS.
DO NOT SCALE THIS DRAWING

RF-001 RF-001 RF-001 RF-001


02 02

3310

3310
ISSUE DATE FOR

2000

2000
RFG-001 RFG-001 G 13/09/2022 Works Approval
H 19/09/2022 30% Submission
RF-001 I 12/10/2022 For Coordination
6,213 mm Note: Custom Corner
6,223 mm RF-001 placed over ridge ROOF J 14/10/2022 NCA RFI
8400

13,831 mm RL3 2000 MAINTENANCE/ K 24/10/2022 For information


2000 2000
2000 ACCESS ZONE L 28/11/2022 For information
9,305 mm

FL-001
RL1 FL-001 RL2 FL-001
TBC M 10/03/2023 For information - Building Shift
2000

143,531 mm 9,305 mm 5,900 mm N 21/04/2023 For Coordination


RF-001 46,398 mm RF-001

2000
O 05/05/2023 Package 2 Issue to DOMA for review
2800

15,819 mm
03 03 P 17/05/2023 Final Base Building Design - Package 2

2000
Q 02/06/2023 Package 3 Issue To Doma For Review
RFG-001
FL-001 FL-001 R 16/06/2023 Final Base Building Design - Package 3
S 01/08/2023 Final Base Building Design

RFG-001
2050

2050
RFG-001 T 01/09/2023 BA03 Submission
RFG-001 RF-001 U 18/10/2023 For information
8400

WCT-002 FL-001
FL-001
WCT-002
G
N IN
F OP E
RA PLENUM 1925 ROO 1925
BUILDER
COOLING TOWERS RA PLENUM 7,903 mm
L6.07 BLOC CONSTRUCTIONS (ACT)
L6.08 L6.09 CONTRACTOR
04 RFG-003 WCT-002 04 CONSULTANT

S4B STUDIO

2000
1550
SERVICES CONSULTANT
CONSULTANT
8400

Note: Custom Corner


placed over ridge TENNANT HYDRAULIC CONSULTING SERVICES
HYDRAULIC CONSULTANT
CONSULTANT

INDESCO
05 BASE BUILDING PV SOLAR PANELS 2000 05 STRUCTURAL CONSULTANT
CONSULTANT
FLOATING
GENERATOR ROOM
OVERRUN

OVERRUN
SLAB TO REDBOX DESIGN GROUP

23,361 mm
GENERATOR L6.15
LANDSCAPE DESIGN
ROOMS ATRIUM
8400

2050 1 DEVELOPMENT MANAGER


RF-001 RF-001 RF-001 SKYLIGHT
RF-001 RF-001 AR-10C XX-04
RFG-001

RFG-001
1
AR-10C XX-02
CHILLER ROOM

FT-07

FT-07

FT-07

FT-07

FT-07
L6.18
FL-001

06 1 GL 1 06
RFG-001

FL-001 MATV & DAS 2050


AR-10D XX-02 ANTENNAE LOCATION RF-001 AR-10D XX-02

RAKING SKYLIGHT Note: Custom Corner


GLAZING placed over ridge
8400

WALL CLADDING TO
TENANCY GENERATOR
60,647 mm LIFT SHAFT OVERRUN

RFG-001
PROVISION RA PLENUM COM BMS H ELC TENANCY ELEC CUPD TENANCY ELEC CUPD H ELC
U Roof flashing shown

2000
L6.16 L6.14 RF-001
DOMA
07 PLANT ROOM
07 CLIENT NUMBER
HYDRAULIC
2000 L6.01 FL-001
VENT PIPES RA PLENUM
7,927 mm
1909010
L6.10

FL-001
PROJECT
8400

1550
MECHANICAL
15 Sydney Ave - Commercial

RFG-001
PENETRATIONS RF-001 15 SYDNEY AVENUE

17,761 mm
WCT-002 BARTON
RFG-003 RFA-005
CANBERRA
08 08
WCT-002

2000
1925 1925 BVN PROJECT NUMBER

FL-001
FL-001

DHW PLANT
6,595 mm BOX GUTTER TO

WCT-002
4,756 mm L6.11
HEAT PUMPS F O P E N IN G RFA-002 TO ROOF PERIMTER 6,553 mm 1909010
ROO
L6.19 MAIN ROOF
8400

RA PLENUM RA PLENUM
RFG-001 DRAWING KEY
RFG-001
2050

2050
L6.13 L6.12 WCT-002 UP
STAIR 07

FL-001 2,545 mm 2,553 mm UP FL-001


2000

2000

2000
RFG-001
09 RF-001 RF-001 LOUVRED ACCESS GATE RF-001 09

2000
2000

SEAMLESSLY INTEGRATED 10,948 mm


RF-001
2000 WITH LOUVRED FACADE 2000 12,398 mm
15,038 mm 9,171 mm 2,227 mm
8400

RF-001 2000 2,546 mm 4,770 mm


RL4 FL-001
9,837 mm 191,910 mm
FL-001
2,563 mm
8,460 mm TRUE NORTH PROJECT NORTH
RFG-001 ROO
10 10 RF-001 RF-001 10
2000

NOT
2000

RFG-003 GRAPHIC SCALE

16,859 mm ROO
11,894 mm 2,581 mm U Updated structure (columns and
2,048 mm 1,859 mm frames) 0 2000 5000
RFA-003 TO REF
99° 81° SCALE
mm LOWER ROOF MAIN
11,733
Concept KEY 1 : 200@A1
Note: Custom Corner STATUS
placed over ridge

DETAIL DESIGN
Note: Custom Corner
DRAWING
placed over ridge

1 1
AR-10D XX-05 AR-10C XX-01

- FLOOR PLAN - PLANT


1 GA PLAN - LEVEL 06 - PLANT ISSUE

A B C D E F G H I J K 1 : 200
AR-10B 06-01 U
C:\Users\bwong\REVIT_LOCAL\2022\AR_1909010_DOMA_ATO BUILDING_2022_brian-wong.rvt 18/10/2023 4:20:15 PM

You might also like