Compact laboratory balance KERN PFB

02

Quick-displaying precision balance with user-friendly


operation modes and EC type approval
Features • Separate second display standard for • Overall dimensions (without draught shield)
models PFB 600-1M and PFB 6000-0M. WxDxH 200x190x87 mm
• Easy to use: All primary functions have their Suitable for direct sales to the public. The • Net weight approx. 2 kg
own key on the keypad verification value is the same as the readout. • Permissible ambient temperature 5 °C / 35 °C
• Compact size, practical for small spaces Large backlit LCD display, digit height 16 mm.
• Capacity display: A bar lights up to show Interface cable to the balance, cable length Accessories
how much of the weighing range is still approx. 1 m, standard.
available Dimensions WxDxH 250x180x105 mm • Separate second display, ideal for
• Level indicator and levelling feet for training and demonstration purposes in
precise levelling of the scale, fitted as Technical data laboratories or industry, not permitted for
standard, to give the most accurate weighing direct sales to the public,
results • Backlit LCD display, digit height 15 mm KERN PFB-A08
• Draught shield standard for models with • Weighing plate dimensions, stainless steel, • Bluetooth data interface for wireless data
weighing plate size and . Ø 80 mm, transfer to PC, must be ordered at purchase,
Weighing space WxDxH 158x143x64 mm Ø 120 mm, KERN PFB-A10
WxD 155x145 mm, see enlarged picture • Suitable printers see page 177 ff.

STANDARD OPTION FACTORY

MULTI
only PFB-M

Model Weighing Readout Verification Repro- Linearity Weighing Options


range value ducibility plate Verification DAkkS Calibr. Certificate
[Max] [d] [e]
KERN g g g g g KERN KERN
PFB 120-3 120 0,001 – 0,001 ± 0,003 – – 963-127
PFB 200-3 200 0,001 – 0,001 ± 0,003 – – 963-127
PFB 300-3 300 0,001 – 0,002 ± 0,003 – – 963-127
PFB 1200-2 1200 0,01 – 0,01 ± 0,03 – – 963-127
PFB 2000-2 2000 0,01 – 0,01 ± 0,03 – – 963-127
PFB 3000-2 3000 0,01 – 0,01 ± 0,03 – – 963-127
PFB 6K0.05 6000 0,05 – 0,05 ± 0,15 – – 963-128
PFB 6000-1 6000 0,1 – 0,1 ± 0,3 – – 963-128
Note: For applications that require verification, please order verification at the same time, initial verification at a later date is not possible.
Verification at the factory, we need to know the full address of the location of use.
PFB 600-2M 600 0,01 0,1 0,01 ± 0,02 965-216 963-127
PFB 600-1M 600 0,1 0,1 0,1 ± 0,1 965-216 963-127
PFB 6000-1M 6000 0,1 1 0,1 ± 0,3 965-217 963-128
PFB 6000-0M 6000 1 1 1 ±1 965-217 963-128

Order
For more
Hotline:
information,
Go to back
please
page
visit
of kern-sohn.com/en/PFB
catalogue · Order hotline +49 [0] 7433 9933 - 0 Precision balances 23
KERN & SOHN GmbH • Ziegelei 1 • 72336 Balingen • Deutschland • Tel. + 49-[0]7433-9933-0 • Fax + 49-[0]7433-9933-149 • www.kern-sohn.com• info@kern-sohn.com
KERN Pictograms:
Internal adjusting: Quick setting up of the Piece counting: Reference quantities selec- Suspended weighing: Load support with
balance‘s ­accuracy with internal adjusting table. Display can be switched from piece hook on the underside of the balance.
weight (motor­driven). to weight.

Adjusting program CAL: For quick setting up Recipe level A: Separate memory for the Battery operation: Ready for battery
of the balance‘s accuracy. External adjusting weight of the tare container and the recipe operation. The battery type is specified
weight required. ingredients (net total). for each device.

Memory: Balance memory capacity, e.g. for Recipe level B: Internal memory for complete Rechargeable battery pack:
article data, weighing data, tare weights, recipes with name and target value of the recipe Rechargeable set.
PLU etc. ingredients. User guidance through display.
Universal mains adapter: with universal input
Alibi memory: Electronic archiving of Recipe level C: Internal memory for complete and optional input socket adapters for
weighing results, complying with the recipes with name and target value of the MULTI A) EU, GB
ALIBI 2009/23/EC standard. recipe ingredients. User guidance through B) EU, GB, CH, USA
display, adjustment of recipe when dosages C) EU, GB, CH, USA, AUS
are exceeded, multiplier function, barcode.
Data interface RS-232: To connect the Mains adapter: 230V/50Hz in standard
balance to a printer, PC or network. version for EU. On request GB, USA or AUS
version available.

RS-485 data interface: To connect the balance Totalising level A: The weights of similar Power supply: Integrated in balance.
to a printer, PC or other peripherals. High toler­ items can ­be added together and the total 230V/50Hz standard EU. More standards
ance against electromagnetic disturbance. can be printed out. e.g. GB, USA or AUS on request.

USB data interface: To connect the balance Totalising level C: Internal memory for com- Weighing principle: Strain gauge
to a printer, PC or other peripherals. plete recipes with name and target value of Electrical resistor on an elastic
the recipe ingredients. User guidance through deforming body.
display, adjustment of recipe when dosages
Bluetooth* data interface: To transfer data are exceeded, multiplier function, barcode Weighing principle: Tuning fork
from the balance to a printer, PC or other recognition. A resonating body is electromagnetically
peripherals. excited, causing it to oscillate.

WLAN data interface: To transfer data Percentage determination: Determining Weighing principle: Electromagnetic force
from the balance to a printer, PC or other the deviation in % from the target value compensation Coil inside a permanent magnet.
peripherals. (100 %). For the most accurate weighings.

Control outputs (optocoupler, digital I/O): Weighing units: Can be switched to e.g. non- Weighing principle: Single cell technology
To connect relays, signal lamps, valves, etc. metric units at the touch of a key. See balance Advanced version of the force compensation
model. Please refer to KERN‘s website for principle with the highest level of precision.
more details.
Interface for second balance: For direct Weighing with tolerance range: Upper and Verification possible:
connection of a second balance. lower limiting values can be pro­grammed indivi- The time required for verification is specified
dually for e.g. dosing, sorting and portioning. in the pictogram.

Network interface: For connecting the scale Hold function: (Animal weighing program) DAkkS calibration possible (DKD): The time
to an Ethernet network. With KERN products When the weighing conditions are un­stable, required for DAkkS calibration is shown in days
you can use a universal RS-232/LAN converter. a stable weight is calculated as an average in the pictogram.
value.
Wireless data transfer: between the weighing Protection against dust and water splashes Package shipment: The time required for
unit and the evaluation unit using an integrated IPxx: The type of protection is shown in the internal shipping preparations is shown in days
radio module. pictogram. in the pictogram.

GLP/ISO log: The balance displays the ATEX explosion protection: Suitable for use Pallet shipment: The time required for inter-
weight, date and time, regardless of a printer in hazardous industrial environments, in which nal shipping preparations is shown in days in
connection. there is explosion danger. The ATEX marking is the pictogram.
specified for each device.
GLP/ISO log: With weight, date and time. Stainless steel: The balance is protected Warranty: The warranty period is shown in
Only with KERN printers. against corrosion. the pictogram.

KERN – Precision is our business


To ensure the high precision of your balance KERN offers you the the appropriate balances, test weights and force-measuring devices 24 hours a day, 7 days a week.
test weight in the international OIML error limit classes E1-M3 from 1 mg - 2000 kg.
In combination with a DAkkS calibration certificate the best pre-requisite for Range of services:
proper balance calibration. • DAkkS calibration of balances with a maximum load of up to 50 t
• DAkkS calibration of weights in the range of 1 mg – 2500 kg
The KERN DAkkS calibration laboratory today is one of the most modern and • Database supported management of checking equipment and reminder service
best-equipped DAkkS calibration laboratories for balances, test weights and force- • Calibration of force-measuring devices
measurement in Europe. • DAkkS calibration certificates in the following languages D, GB, F, I, E, NL, PL
Thanks to the high level of automation, we can carry out DAkkS calibration of

Your KERN specialist dealer:

*The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by KERN & SOHN GmbH is under license.
Other trademarks and trade names are those of their respective owners.

You might also like