You are on page 1of 1

Component - Plastics

File Number: E162823

FORMOSA CHEMICALS & FIBRE CORP PLASTICS DIV


201 TUNG HWA N RD
TAIPEI, 105 Taiwan

TAIRILAC: AF3500
Acrylonitrile Butadiene Styrene (ABS), pellets

Flammability Value Test Method


Flame Rating
1.5 mm, ALL HB UL 94
3.0 mm, ALL HB UL 94
3.0 mm, ALL HB40 IEC 60695-11-10, -20
1.5 mm, ALL HB75 IEC 60695-11-10, -20
Electrical Value Test Method
Hot-wire Ignition (HWI) UL 746
1.5 mm PLC 5
3.0 mm PLC 4
High Amp Arc Ignition (HAI) UL 746
1.5 mm PLC 0
3.0 mm PLC 0
Comparative Tracking Index (CTI) PLC 0 UL 746
High Voltage Arc Tracking Rate (HVTR) PLC 1 UL 746
Arc Resistance PLC 6 ASTM D495
Thermal Value Test Method
RTI Elec UL 746
1.5 mm 60.0 °C
3.0 mm 60.0 °C
RTI Imp UL 746
1.5 mm 60.0 °C
3.0 mm 60.0 °C
RTI Str UL 746
1.5 mm 60.0 °C
3.0 mm 60.0 °C

Page 1 of 1 Form Number: E162823-224706


UL and the UL logo are trademarks of UL LLC Copyright © 2020 All Rights Reserved. | www.ul.com Report Date: 1995-11-01
Last Revised: 1/17/2013
ANSI/UL 94 small-scale test data does not pertain to building materials, furnishings and related contents. ANSI/UL 94 small-
scale test data is intended solely for determining the flammability of plastic materials used in the components and parts of end-
product devices and appliances, where the acceptability of the combination is determined by UL.