CONE PENETRATION TEST (2 TON)

Project : GOR Sukoharjo Weather : Mendung


Location : Sukaharjo - Jawa Tengah Date : 06/12/19

Test no. : S-1 Tested by : Ags


Elevation : +99,70 m, ( Selasar Gedung Pendopo dianggap +100,00 m)

Depth qc qc + qf fs ft Fr
2 2 2
(m) kg/cm kg/cm kg/cm kg/cm %
13,80 85,0 96,0 1,10 144,4 1,29
14,00 96,0 108,0 1,20 146,8 1,25
14,20 80,0 92,0 1,20 149,2 1,50
14,40 82,0 90,0 0,80 150,8 0,98
14,60 72,0 84,0 1,20 153,2 1,67
14,80 45,0 58,0 1,30 155,8 2,89
15,00 60,0 68,0 0,80 157,4 1,33
15,20 62,0 74,0 1,20 159,8 1,94
15,40 55,0 66,0 1,10 162,0 2,00
15,60 55,0 68,0 1,30 164,6 2,36
15,80 60,0 70,0 1,00 166,6 1,67
16,00 64,0 78,0 1,40 169,4 2,19
16,20 55,0 65,0 1,00 171,4 1,82
16,40 68,0 80,0 1,20 173,8 1,76
16,60 78,0 90,0 1,20 176,2 1,54
16,80 74,0 84,0 1,00 178,2 1,35
17,00 75,0 85,0 1,00 180,2 1,33
17,20 66,0 78,0 1,20 182,6 1,82
17,40 78,0 90,0 1,20 185,0 1,54
17,60 100,0 112,0 1,20 187,4 1,20
17,80 108,0 116,0 0,80 189,0 0,74
18,00 102,0 112,0 1,00 191,0 0,98
18,20 105,0 114,0 0,90 192,8 0,86
18,40 118,0 125,0 0,70 194,2 0,59
18,60 150,0 166,0 1,60 197,4 1,07
18,80 142,0 154,0 1,20 199,8 0,85
19,00 120,0 130,0 1,00 201,8 0,83
19,20 120,0 132,0 1,20 204,2 1,00
19,40 100,0 108,0 0,80 205,8 0,80
19,60 105,0 118,0 1,30 208,4 1,24
19,80 188,0 198,0 1,00 210,4 0,53
20,00 200,0 210,0 1,00 212,4 0,50
20,20 240,0 250,0 1,00 214,4 0,42