You are on page 1of 1

1 2 3 4 5 6

1 2 1 1

PROPOSED HEALTH
UNIT BUILDING

KEY PLAN

16
5 6 7 8 7 8
3 4

7 8 9 15
3 6 7 8

Rev Description DRN CHD. VER. DATE


DESIGN CONSULTANTS
RSB ARCH PROJECT CONSULTANTS PVT. LT.
3
7 8 6 9 7 8
15 No:1,First Floor ,Maskur Building,
Krishnamma Road,Nungambakkam,
Chennai - 600034

EPC AGENCY
RPDPL - YFC (JV)
No : 33/2B1 Rank paradise,
Mullai Nagar ,Suramangalam,
Salem - 636005,
Tamilnadu.

AUTHORITY ENGINEER

AUTHORITY
Southern Railway,
3 1 4 5 6 5 7 CL CL Kozhikode (Calicut) Railway Station,
X
Kozhikode - 673001, Kerala.

DOCUMENT REVIEW
This document has been reviewed for compiance with
the intent of design documentation and is
A No Objection. Proceed with the Works

Objection. Proceed with the Works Subjected


B to incorporation of Comments as Noted

C Rejected.Resubmit.

Received for Information/More Information


D required.Not Reviewed
NOTES:
1. ALL DIMENSIONS ARE IN MILLIMETER, UNLESS OTHERWISE SPECIFIED. THIS REVIEW DOES NOT RELIEVE OR DIMINISH THE CONTRACTOR'S RESPONSIBILITY TO
2. DRAWING SHOULD NOT BE SCALED, FOLLOW FIGURED DIMENSIONS. COMPLETE THE WORKS IN FULL ACCORDANCE WITH THE CONTRACT
3. ANY DISCREPANCY IN DRAWING SHALL BE BRING TO NOTICE OF STRUCTURAL
CONSULTANT BEFORE EXECUTION OF WORK. AUTHORITY
4. THIS DRAWING SHOULD BE READ ALONG WITH THE RELEVANT CHIEF ENGINEER DEPUTY CHIEF ENGINEER AXEN
ARCHITECTURAL DRAWING.
5. IF THERE IS ANY REVISION IN DRAWING, FURTHER CONSTRUCTION SHALL BE
EXECUTED AS PER THE LATEST REVISED DRAWING, ON THE ISSUE OF LATEST
REVISION.
6. GRADE OF CONCRETE SHALL BE M30.GRADE OF STEEL SHALL BE Fe500D
7. CHAIR SHALL BE PROVIDED TO SUPPORT TOP BAR
SSE
8. FIXING AND BENDING OF REINFORCEMENT SHALL BE AS PER IS 2502
9. USE CONCRETE VIBRATOR FOR ALL RCC WORKS
10. USE COVER BLOCK IF CM 1:1
11. CUBE TEST ARE TO BE DONE.THERE SHALL BE ONE SET OF THREE CUBES PER
EVERY 20m3 CEMENT CONCRETE OR PART THERE OF USED AT SITE AND SHALL
1 1 3 2 6 3 BE TESTED ON 7TH/28TH DAYS
2 12. CLEAR COVER FOR EPC
2 3 PILE CAP : 75mm
PILE : 50mm PROJECT ARCHITECT PROJECT DESIGN DIRECTOR LEAD DESIGNER EPC AGENCY:

SUGAVAN
COLUMN : 40mm
BEAM : 30mm
RADHAKRISH VINOTHKUMAR
SLAB : 25mm
NEELIAT Digitally signed
13. DEVELOPMENT FOR ALL THE ZONES
FOR 500D GRADE OF STEEL Ld : 46 Ø (COMPRESSION) NAN SURESH H
by NEELIATH
KANNOTH AN R SHANMUGAVEL
Ld : 46 Ø + 10 db (TENSION)
KANNO MANEE
Date: Digitally signed by Digitally signed by
14. DESIGNED FOR SEISMIC LOAD AS PER IS 1893(part I) 2016 Digitally signed by VINOTHKUMAR
15. CONSIDERED DEAD & LIVE AS PER IS 875-1987(part II) RADHAKRISHNAN SURESH TH 2024.02.17
19:12:41 SUGAVANAN R SHANMUGAVEL
WIND LOAD AS PER IS 875-2015(part III) Date: 2024.02.17 11:06:43 MANEE +05'30' Date: 2024.02.17 Date: 2024.02.27 12:10:47
16. THE BUILDING IS DESIGNED FOR GROUND+1 ONLY +05'30' +05'30'
10:02:58 +05'30'
LEGENDS:
Ld
TYP
- DEVELOPMENT LENGTH
- TYPICAL
PROPOSED HEALTH UNIT BUILDING
C/C - CENTER TO CENTER
C/S
FFL
- CROSS SECTION
- FINISHED FLOOR LEVEL
GRADE BEAM LONGITUDINAL SECTION
LVL
CL
- LEVEL
- CENTRE LINE DETAILS
PROOF CONSULTANTS:
DATE 16/02/24 SCALE DWG NO:
Digitally signed by PROJ. NO. 000 EPC-CLT-RHU-W-STR-03-SH-02
RAJARAM
DRAWN DMN
RAJARAM SATISH KUMAR THESE DRAWINGS ARE UNDER COPYRIGHT AND ARE THE PROPERTY OF RSB ARCH PROJECT CONSULTANTS.NONE OF THE DRAWING

SATISH KUMAR Date: 2024.02.16 19:30:06 AND RELATED DOCUMENTS CAN BE REPRODUCED,COPIED IN WHOLE OR IN PART WITHOUT PRIOR EXPRESSED WRITTEN CONSENT OF
RSB ARCH PROJECT CONSULTANTS. THESE DRAWINGS CANNOT BE HANDED OVER TO A THIRD PARTY OR USED FOR ANY
+05'30' PURPOSE,OTHER THAN FOR WHICH IT HAS BEEN LOANED.AFTER FULFILLED THE PURPOSE OF ISSUE THE DRAWINGS SHALL BE
RETURNED TO RSB ARCH PROJECT CONSULTANTS.